• Title/Summary/Keyword: 비탄성변형

Search Result 123, Processing Time 0.02 seconds

Experimental Study on Failure Behavior of Steel Members and Elements under Very Low Load-Cycles (극저하중(極低荷重)사이클을 받는 강부재(鋼部材) 및 요소(要素)의 파괴거동(破壞擧動)에 관한 실험적(實驗的) 연구(硏究))

  • Park, Yeon Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.2
    • /
    • pp.257-268
    • /
    • 1994
  • An experimental study was carried out to elicit important factors causing cracks and rupture of steel members and their elements under imposed large repeated deformations, and of the quantitative relationships among the important physical factors leading to failure. Each of twenty-eight angles and nine thin-plates served as the specimen and was subjected to repeated axial load after undergoing inelastic buckling. Particular attention was paid to the effects of loading pattern, failure mode and cross-sectional shape on the very-low-cycle failure behavior under loading repetitions of the order of a few to twenty. The experimental results show that energy dissipation capacity depends heavily on the entire history of loading, the failure mode, the slenderness ratio and the width-to-thickness ratio. No simple quantitative relations were observed between the initiation of the visible cracks or rupture and the energy dissipation capacity. The maximum values of residual "net" strains are found to range from 25% to 40%, independent of the test parameters.

  • PDF

Analytical Investigation for Improved Design Models of Chevron Braced Frames (역V형 가새 골조의 개선된 디자인 모델을 위한 해석적 연구)

  • Yoo, Jung-Han
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.73-78
    • /
    • 2009
  • Steel Braced frames are a commonly-used seismic resisting system, and chevron steel braced frames are a frequently used type of steel braced frame. Recent research has indicated that the seismic performance of braced frames can be improved by designing the braced frame gusset plate connections in a manner that direct reflects seismic deformation demands, and by permitting yielding in the gusset plate at select performance levels. A parametric study using Finite Element (FE) models was conducted to examine the influence of the gusset plate and framing elements on the seismic performance of chevron braced frames, and to calibrate and develop improved design models. The impact of the frame details, including frame sizes, clearance requirements, gusset plate thickness and tapered plate, was explored. The results suggested that proper detailing of the connection can result in a significant improvement in the frame performance. The results also show that the gusset plate thickness has a significant impact on frame performance.

Correlation of Experimental and Analytical Inelastic Responses of A 1:12 Scale 10-Story Reinforced Concrete Frame with Non-seismic Details (비내진 상세를 가진 1:12축소 10층 R.C.골조의 비선형 거동에 대한 실험과 해석의 상관성)

  • Lee, Han-Seon;Kang, Kyi-Yong
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.1
    • /
    • pp.267-277
    • /
    • 1999
  • The pushover analysis technique is now attracting the world-wide interest for the prediction of elastic and inelastic behavior of structures in the seismic evaluation of existing buildings. However, the reliability of this analysis technique has not been fully checked by the test results in the case of structures with nonseismic details. The objective of this study is to verify the correlation between the experimental and analytical responses of a 1:12 scale 10-story reinforced concrete frame with non-seismic details by using DRAIN-2DX program and the test results performed previously. It is concluded from this comparison that the overall responses such as the relations between story shear versus interstory drift and the local deformations such as plastic rotations can be predicted with quite high reliability.

Reversed Cyclic Latcral Load Test of A 2-Bay 2-Story Reinforced Concrete Frame With Seismic Detail (내진상세를 가진 2경간 2층 철근콘크리트 골조의 반복횡하중 실험)

  • Lee, Han-Seon;Woo, Sung-Woo
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.6
    • /
    • pp.183-193
    • /
    • 1996
  • The objective of this study is to investigate the characteristics of elastic and inelastic bekavior of ductile momenting-resisting reinforced concrete frame subjected to reversed lateral loading such as earthquake excitations. For this purpose, a 2-bay 2-story reinforced concrete plane frame with seismic detail was designed and one 1/2.5-scale subassemblage was manufactured according to the required similitude law. Then, the reversed load test under the displacement control was performed statically to this subassemblage. Finally, the results of this test were analysed regarding to (1) the design load vs actual strength, (2) degradation in stiffness and strength. (3) failure mode or energy dissipation. (4) local deformations.

Seismic Behavior of A 2/5-Scale Steel Structure with Added Viscoelastic Dampers (점탄성 감쇠기를 설치한 2/5 축척 강구조물의 지진하중에 의한 거동연구)

  • Oh, Soon-Taek
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.1
    • /
    • pp.80-87
    • /
    • 1993
  • This paper summarizes an experimental and analytical study on the application of viscoelastic dampers as energy dissipation devices in structural applications. Shaking table tests are carried out on the viscoelastically damped structure and the obtained structural responses are compared to those of the inelastic analysis results for the same test structure with no dampers added. It can be concluded the viscoelastic dampers are effective in reducing excessive vibrations of structures under strong earthquake ground motions. It is also observed that the increase in structure's stiffness by the addition of dampers can not contribute to improving the seismic response of a structure. In general. the reduction of the seismic response by adding the dampers to the structure is mostly resulted from the increased damping effect. It is found that the modal strain energy method can be used to reliably predict the equivalent structural damping. and the seismic response of a viscoelastically damped structure can be accurately estimated by conventional modal analysis techniques.

  • PDF

Improved Stability Design of Plane Frame Members (평면프레임 구조의 개선된 좌굴설계)

  • Kim, Moon Young;Song, Ju Young;Kyung, Yong Soo
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.2
    • /
    • pp.225-237
    • /
    • 2006
  • Based on the study conducted by Kim et al. (205a, b), an improved stability design method for evaluating the effective buckling lengths of beam-column members is proposed herein, using system elastic/inelastic buckling analysis and second-order elastic analysis. For this purpose, the stress-strain relationship of a column is inversely formulated from the reference load-carrying capacity proposed in design codes, so as to derive the tangent modulus of a column as a function of the slenderness ratio. The tangent stiffness matrix of a beam-column element is formulated using the so-called "stability functions," and elastic/inelastic buckling analysis Effective buckling lengths are then evaluated by extending the basic concept of a single simply-supported column to the individual members as one component of a whole frame structure. Through numerical examples of several structural systems and loading conditions, the possibilities of enhancement in stability design for frame structures are addressed by comparing their numerical results obtained when the present design method is used with those obtained when conventional stability design methods are used.

Material Properties of 400MPa Grade Hot Rolled H-beam(SHN400) for Building Structure (400MPa급 건축구조용 열간압연 H형강(SHN400)의 소재 특성)

  • Kim, Hee-Dong;Choi, Byoung-Jeong;Kim, Sang-Sub;Kim, Chul-Hwan;Oh, Young-Suk
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.4
    • /
    • pp.515-522
    • /
    • 2011
  • The purpose of this study was to evaluate the material characteristics of SHN400 steel, which is suitable as a steel material for building structures, using the experimental approach. For this purpose, the chemical composition test, tensile test, macro test, micro test, and charpy notch impact test were conducted with specimens taken from the highest, thickest, and commonly used H-beams for girder or beam members. Each test was conducted under the Korean Standard(KS) test conditions. All the test results satisfied the requirements of KS (KS D 3866) and the steel material for seismic design. The carbon equivalent value (Ceq), which is related to weldability, and the yield ratio, which is related to inelastic behavior, showed especially good results. Thus, SHN400 is definitely suitable as the steel material for building structures.

Seismic Damage Analysis for Element-Level and System-Level of Steel Structures (강구조물의 구조요소 및 구조계에 대한 지진손상도 해석)

  • 송종걸;윤정방;이동근
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.1
    • /
    • pp.95-111
    • /
    • 1998
  • In this study, the concepts and procedures of the seismic damage analysis methods are examined for both the element-level and the system-level. The seismic damage analysis at the element-level is performed for several example structures using existing method for structural elements or single-degree-of-freedom (SDOF) systems such as the Park and Ang method. In order to analyze seismic damage at the system-level, two types of procedures are used. In the first type of procedure, the system-level seismic responses can be estimated by using the system representative response method(SRRM), or the equivalent SDOF system response method (ESDOF-SRM). Then, the system-level seismic damage is analyzed from the system-level seismic responses using existing method for structural elements or SDOF systems. IN the second type of procedure, the system-level seismic damages are analyzed using the element damage combination method (EDCM) combing the element-level damage indices determined by existing method. To compare tendency of the seismic damage analysis using each methods, example analysis is accomplished for several cases of different structures and different earthquake excitation.

  • PDF

Layered Section Analysis for PSC Girder with Variable Cross Section Using SI Technique (SI기법을 이용한 변단면 PSC 거더의 층상화 단면해석)

  • Kim, Byeong Hwa;Park, Taehyo;Jeon, Hye-Kwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.6A
    • /
    • pp.581-590
    • /
    • 2010
  • This study introduces a layered sectional analysis for a PSC girder with a vaiable cross section and curved tendons. To consider the shear equilibrium at a concrete layer with curved tendons, the shear stress distribution has been computed at each section. In addition, to improve the convergence to the solution, a system identification technique is newly adopted in the solution process for strain computation. To examine the feasibility of the proposed approach, a static load test has been conducted for a full scale PSC girder with variable cross section. The prediction shows a good agreement with experiment. It is seen that a uniform cross section has the same moment capacity with a variable cross section while the variable cross section has more shear capacity than the uniform cross section. It is also noted that the maximum displacement of a variable cross section is a little smaller than a uniform cross section.

Flexural Test of H-Shape Members Fabricated of High-Strength Steel with Considering Local Buckling (국부좌굴을 고려한 고강도 조립 H형강 부재의 휨성능 실험)

  • Lee, Cheol-Ho;Han, Kyu-Hong;Park, Chang-Hee;Kim, Jin-Ho;Lee, Seung-Eun;Ha, Tae-Hyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.4
    • /
    • pp.417-428
    • /
    • 2011
  • Depending on the plastic deformation capacity required, structural steel design under the current codes can be classified into three categories: elastic, plastic, and seismic design. Most of the current steel codes explicitly forbid the use of a steel material with a yield strength higher than 450 MPa in the plastic design because of the concerns about its low plastic deformation capacity as well as the lack of test data on local and lateral torsional buckling behavior. In this study, flexural tests on full-scale H-shape members built with SM490A (ordinary steel or benchmark material) and HSB800 (high-strength steel) were carried out. The primary objective was to investigate the appropriateness of extrapolating the local buckling criterion of the current codes, which was originally developed for normal-strength steel, to the case of high-strength steel. All the SM490A specimens performed consistently with the current code criteria and exhibited sufficient strength and ductility. The performance of the HSB800 specimens was also very satisfactory from the strength perspective; even the specimens with a noncompact and slender flange developed the plastic moment capacity. The HSB800 specimens, however, showed an inferior plastic rotation capacity due to the premature tensile fracture of the beam bottom flange beneath the vertical stiffener at the loading point. The plastic rotation capacity that was achieved was less than 3 (or the minimum level required for a plastic design). Although the test results in this study indicate that the extrapolation of the current flange local-buckling criterion to the case of high-strength steel is conservative from the elastic design perspective, further testing together with an associated analytical study is required to identify the causes of the tensile fracture and to establish a flange slenderness criterion that is more appropriate for high-strength steel.