• Title/Summary/Keyword: 비정상적 운전

Search Result 118, Processing Time 0.029 seconds

Study on the Improvement Process for the Food Waste Resource Facility (I) - Focus on Composting Facility of DDM Environmental Resource center - (음식물류 폐기물 자원화시설의 공정개선에 관한 연구(I) - DDM환경자원센터의 퇴비화시설 사례를 중심으로 -)

  • SHIN, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.3
    • /
    • pp.15-22
    • /
    • 2018
  • This study refers to the composting of DDM Environmental Resource Center, which is operating abnormally in the food waste public-resource facilities that are operating nationwide, in accordance with the initial operating conditions. Similar process cases were investigated to examine issues concerning unusual composting facilities in DDM environmental resource centers and to analyse the causes of the issues. In addition, several improvement measures and alternatives for converting abnormal driving facilities into normal driving facilities may be proposed, and major abnormal driver provisions that are highlighted as issues during field application may be resolved.

Study on the Improvement Process for the Food Waste Resource Facility (II) - Focus on Deodorization Facility of DDM Environment Resource Center - (음식물류 폐기물 자원화시설의 공정개선에 관한 연구(II) - DDM환경자원센터의 탈취시설 사례를 중심으로 -)

  • Kim, Choong-Gon;Bae, Yoonhwan;SHIN, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.1
    • /
    • pp.33-38
    • /
    • 2019
  • This study refers to the deodorization of DDM Environmental Resource Center, which is operating abnormally in the food waste public-resource facilities that are operating nationwide, in accordance with the initial operating conditions. Issues concerning the abnormal deodorization facilities of DDM Environment Resource Center were the deodorization of composting facilities, indoor air quality problems, and overall deodorization of facilities, especially the phenomenon of stopping while operating the RTO and the phenomenon of poor spray in the wet scrubber etc. As an alternative and improvement method for converting such abnormal operation facilities into normal operation facilities, It is proposed to remove the front filter of the upper part of the fermentation tank, and to install scrubbers, air and water separator, and roll filters for dust removal etc.

Steady-State Analysis of Single Phase LSPM Motor using the Laplace's Transform (Laplace 변환을 이용한 단상 LSPM전동기의 정상상태 기동특성 해석)

  • Choi, Myoung-Hyun;Kim, Byung-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.820-821
    • /
    • 2011
  • 본 논문은 단상 line-start permanent- magnet (LSPM) 전동기가 가지는 비동기 운전영역에서 나타나는 다양한 토크성분을 해석적 방법으로 분석한다. 비 동기속도에서의 정상상태 전류를 DQ 등가회로를 이용하여 유도하였으며, 이를 이용하여 유도전류와 제동전류의 주파수를 확인하였다. 마지막으로 시간차분 해석을 이용하여 비동기 운전영역의 특정 속도에 대한 토크와 전류를 분석하였으며, 주파수 변환을 이용하여 각 전류의 주파수 성분을 확인하였다.

  • PDF

원전 비상직무에서의 주제어실 운전원의 의사소통 수행도 분석

  • 정광섭;박진균;정원대
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2003.10a
    • /
    • pp.86-91
    • /
    • 2003
  • 원자력발전소의 설계는 다중방호의 개념에 의해 이루어져, 그 구조가 복잡하고 운전 형태도 다양하며, 이에 따라 사고의 전개 과정도 다양하게 나타난다. 이로 인해 원자력발전소의 운전원들은 발전소의 유동적인 상황에 대처할 수 있는 고도의 능력이 요구된다. 특히 주제어실 운전원들은 발전소의 기동 및 전출력 운전, 정지, 그리고 비정상 및 비상 상황 시의 적절한 대처에 대한 책임을 지고 있다. 발전소의 사고 분석 결과에 의하면, 사고에 대한 운전원의 대응이 사고의 전개에 직접적인 영향을 미치게 되며, 결과 적으로 사고에 대한 운전원들의 적절한 대응 능력은 발전소의 안전성에 중요한 부분임이 밝혀졌다.(중략)

  • PDF

Irregular Sound Detection using the K-means Algorithm (K-means 알고리듬을 이용한 비정상 사운드 검출)

  • Chong Ui-pil;Lee Jae-yeal;Cho Sang-jin
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.6 no.1
    • /
    • pp.23-26
    • /
    • 2005
  • This paper describes the algorithm for deciding the status of the operating machines in the power plants. It is very important to decide whether the status of the operating machines is good or not in the industry to protect the accidents of machines and improve the operation efficiency of the plants. There are two steps to analyze the status of the running machines. First, we extract the features from the input original data. Second, we classify those features into normal/abnormal condition of the machines using the wavelet transform and the input RMS vector through the K-means algorithm. In this paper we developed the algorithm to detect the fault operation using the K-means method from the sound of the operating machines.

  • PDF

Development of Control Logic for Operation of Fan Stall Warning Equipment Used in Coal-Thermal Power Plant (석탄 화력발전소 송풍기 맥동감시장치 운전을 위한 제어로직 개발)

  • Roh, Yong-Gi;Cho, Hyun-Seob;Jang, Seong-Whan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.5
    • /
    • pp.837-846
    • /
    • 2006
  • In this paper, axial flow fans which applied at coal-thermal power plant(500[MW]) cause a unique phenomenon called 'Stall' under normal operation and this causes abnormal operation and damages the blades. In order to prevent these abnormal operation, this study estimates the reliability of new system which is applying control logic on each parameter with existing black-box-type by field test.

  • PDF

확률논적 안전성분석(PSA)의 최근동향

  • Rasmussen Norman C.
    • Nuclear industry
    • /
    • v.7 no.8 s.54
    • /
    • pp.13-14
    • /
    • 1987
  • 원자력플랜트에 대한 신중한 PSA분석은 많은 이득을 가져왔다. 이러한 것으로는 예기치 못했던 고장모드의 확인, 특히 비정상적인 상황하에서의 플랜트 운전상태의 충분한 파악, 플랜트설비나 운전절차의 변경이 가져오는 영향의 분석 등을 들 수 있다. 이 외에 PSA분석은 특정한 플랜트 문제를 논의하는데 있어 논리적인 기틀을 마련하는 것이다.

  • PDF

Fouling Mitigation for Pressurized Membrane of Side-Stream MBR Process at Abnormal Operation Condition (가압식 분리막을 이용한 Side-Stream MBR 공정의 비정상 운전조건에서 막 오염 저감)

  • Ko, Byeong-Gon;Na, Ji-Hun;Nam, Duck-Hyun;Kang, Ki-Hoon;Lee, Chae-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.6
    • /
    • pp.323-328
    • /
    • 2016
  • Pressurized membrane used for side-stream MBR process requires fouling control strategy both for normal and abnormal operation conditions for stable operation of the facilities. In this study, $85m^3/day$ of pilot-scale side-stream MBR process was constructed for the evaluation of fouling mitigation by air bubble injection into the membrane module. In addition, fouling phenomena at abnormal operation conditions of low influent and/or loading rate were also investigated. Injection of air bubble was found to be effective in delaying transmembrane pressure (TMP) increase mainly due to scouring effect on the membrane surface, resulting in expanded filtration cycle at a high flux of $40L/m^2{\cdot}h$ (LMH). At abnormal operation condition, injection of PACl (53 mg/L as Al) into the bioreactor showed 19% reduction of TMP increase. However, inhibition of nitrifying bacteria by continuous PACl injection was observed from batch experiments. In contrast, injection of powdered activated carbon (PAC, 0.6 g/L) was able to maintain the initial TMP of $0.2kg/cm^2$ for 5 days at the abnormal conditions. It may have been caused from the adsorption of extracellular polymeric substances (EPS), which was known to be excessively released during growth inhibition condition and act as the major foulants in MBR operations.

A Study on the Simulation of Chemical Heat Pump System Based on 2-Propanol /Acetone/Hydrogen System (2-Propanol/Acetone/Hydrogen 반응계로 구성된 화학적 열펌프 시스템의 모사 연구)

  • 김범재;여영구;정연수;송형근
    • Journal of the Korea Society for Simulation
    • /
    • v.5 no.1
    • /
    • pp.43-50
    • /
    • 1996
  • 2-propanol/acetone/hydrogen 반응계로 구성된 화학적 열펌프 시스템은 낮은 온도(82.5~$90^{\circ}C$)에서의 2-propanol의 탈수소화 반응과 높은 온도(약 $200^{\circ}C$ 부근)에서의 acetone의 수소화반응을 이용하여 열을 고품위화 시키는 장치이다. 본 연구에서는 이 시스템의 해석 및 설계를 목적으로 이 시스템에 대한 수치적인 모델들을 세우고 Sequential modular approach를 이용하여 시스템의 모사를 수행하였다. 또한 에너지 효율을 최대화하기 위하여 열펌프 시스템에서의 환류비의 영향을 규명하였다. 모사결과 이 시스템의 scale up을 위한 정량적인 정상상태 운전조건들을 구할수 있었으며 두 반응의 반응 전화율이 다르더라도 반응물의 유량의 차이를 통하여 두 반응열이 거의 같아지는 것을 알수 있었다. 아울러 주어진 운전조건에서 증류의 환류비는 최소환류비 근처의 최적값이 존재함을 알수 있었다.

  • PDF

A Study of Early Warning System for Gas Facilities (가스 시설의 조기 경보 시스템에 대한 연구)

  • Lee Jeong Woo;Yoo Jin Hwan;Ko Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.3 s.28
    • /
    • pp.38-43
    • /
    • 2005
  • There is monitored amount operation variables and controlled by operating conditions and loads at many facilities using gas also chemical plants. The process fault which can be indicated by operators, is occurred when the abnormal state was accumulated continuously owing to physical failure, external disturbance or human error. This is studied a Early Warning System which is to estimate process status by real-time monitoring operation variables and to early warning before it will be occurred process fault.

  • PDF