An Effective Wireless Power Transfer Technique using Permalloy (Permalloy를 이용한 효율적 인 무선 전력송신 기술)

  • Hwang, Jae-Young;Chung, Yeon-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.3
    • /
    • pp.678-683
    • /
    • 2010
  • This paper presents a wireless (contactless) charging technique with a new core material called permalloy. For charging portable devices wirelessly, ferrosilicon or ferrite has been conventionally used. Due to high permeability of permalloy, charging efficiency can be significantly improved and subsequently this high efficiency increases charging distance between charger and portable devices. Comparative experimental studies demonstrate that the charging performance and efficiency with permalloy employed are significantly improved. The proposed wireless charging techniques can be used to charge portable devices efficiently.

Wireless Power Transmission System that Charges Multiple Devices Simultaneously (다수의 기기를 동시에 충전하는 무선전력전송 시스템)

  • Kim, Ki-Taek;Lee, Woo-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.205-206
    • /
    • 2017
  • 현재 무선전력전송 기술의 발전으로 무선충전에 대한 다양한 제품이 빠르게 출시되고 있다. 현재 출시된 제품의 무선충전패드는 자기유도방식을 이용한 접촉식 충전으로 거리의 제한이 있으며, 한 대의 기기밖에 충전할 수 없다. 본 논문에서는 자기공진방식을 이용하여 기기를 비접촉식으로 충전하며, 다수의 기기를 동시에 충전하는 시스템을 소개하고 간단한 결과를 제시한다.

  • PDF

The Study on Forward ZVS MRC for Non-contact Charging Energy Transmission (비접촉 충전 에너지 전달을 위한 포워드형 ZVS MRC에 관한 연구)

  • 김영길;김진우;김태웅;원영진;이성백
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.2
    • /
    • pp.64-72
    • /
    • 2001
  • In this paper, forward Zero Voltage Switching Multi Resonant Converter(ZVS MRC) for non-contact charging energy transmission is reposed. The forward ZVS MRC is effective in adsorbing parasitic element as well as minimizing the switching loss. That can accommodate very high frequency. So forward ZVC MRC is applied to non-contact charging energy transmission. Used converter has saperatable transformer and synchronous rectifiers. Coupling coefficient(k), leakage inductance, coupling inductance and resonant frequency are observed for the air gap. By using the observed value, this circuit is designed and implemented. This proposed circuit is simulated by the PSPICE and experimented. The voltage stress of a main switch and the output power of the converter are measured. This paper show that is compatible for non-contact charging energy transmission.

  • PDF

Characteristics of the ㄷ ㅓ Type Core for Contactless Battery Charger (비접촉식 충전 장치를 위한 ㄷㅓ 형 코어에 관한 연구)

  • Jeon, Sung-Jeup;Heo, Jun;Lee, Kwang-Woon;Cho, Kyu-Hyung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.5
    • /
    • pp.407-417
    • /
    • 2003
  • Detachable transformers used in contactless battery chargers have poor power transfer characteristics because they have low coupling coefficients due to their gaps. The ㄷㅓ type core gives a high coupling coefficient in a contactless battery charger compared with standard cores such as EE, EC and UU. In this paper, characteristics of the ㄷㅓ type core is studied. Detailed analyses and comparisons are given based on the sinusoidal operation and square-wave operation. Reductions in output current, voltage and power are stated analytically and numerically. The analyses are verified by experiments conducted on a ZVS converter including a detachable transformer. The analyses and comparison method can be applied to other gaped transformer such as a PCB transformer.

Magnetic Induction Communication System for Electric Vehicle on Smart Grid (스마트 그리드 전기자동차를 위한 자기장 통신 시스템 구현 연구)

  • Lee, Jong-Min;Chang, Woo-Hyuk;Jung, Bang-Chul
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.9B
    • /
    • pp.1381-1389
    • /
    • 2010
  • The smart grid technology is expected to significantly improve energy efficiency by dynamic power supply. One of its application is the Vehicle-to-Grid(V2G) that utilizes an electric vehicle's battery as a household storage battery. Meanwhile, a lot of researches are recently investigated in the area of wireless energy transfer technology because of its convenience and safety in charging a battery. With the wireless energy transfer infrastructure a wireless magnetic induction communication technique can help the dynamic power supply of the smart grid more efficient. In this paper, we propose a wireless magnetic induction communication sion cowhich includes data transmission and location-aware functions. We expect the sion cohelp the smart grid to control power supply more efficiently. We also developed its test-bed and evaluated the performance.

Analysis and Design of Half-Bridge Resonant Converter for Non-Contact Battery Charger (비접촉식 배터리 충전 장치용 Half-Bridge 직렬 공진 컨버터 분석 및 설계)

  • Kim, Chang-Gyun;Seo, Dong-Hyeon;Yu, Jeong-Sik;Park, Jong-Hu;Jo, Bo-Hyeong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.4
    • /
    • pp.265-271
    • /
    • 2000
  • A non-contact battery charger for cellular phone is designed using half-bridge series resonant converter. This converter utilizes series resonance to reduce the undesirable effect of large leakage inductance of the detachable transformer and ZVS operation can reduce switching loss and switching noise. In this paper, analysis and design procedure of half-bridge series resonant converter with detachable transformer is presented. The input voltage is 85VAC∼270VAC, and the output voltage and current is 4.1V and 800mA, respectively. Furthermore, a method of calculating the secondary current of the transformer to control the battery charging current in the constant current charging mode is proposed. The performance of the charger is verified through experiments.

  • PDF

Analysis on Flexural Behavior of Hollow Prestressed Concrete Filled Steel Tube Piles (프리스트레스를 받는 중공형 콘크리트 충전 강관말뚝의 휨거동 해석)

  • Chung, Heung-Jin;Paik, Kyu-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.2
    • /
    • pp.133-140
    • /
    • 2018
  • A nonlinear finite element analysis was conducted in order to examine the moment capacity and flexural behaviour of hollow prestressed concrete filled steel tube(HCFT) piles which compose hollow PHC piles inside thin wall steel tubes. The parameters investigated in this study were various contact conditions between concrete and steel tube, thickness of concrete tube and various PC strands. A simple method is proposed to determine the ultimate flexural strength based on plastic stress distribution method. In order to verify the proposed method, calculated moment capacity of various HCFT piles are compared with the experiment and numerical analysis results.

A 20kHz Inverter for Inductive Charging System of Electric Vehicle (전기자동차 비접촉식 충전시스템을 위한 20kHz 인버터 설계)

  • Kim, Chul-Woo;Kim, Sang-Beom;Soh, Joon-Young;Lim, You-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1175-1176
    • /
    • 2011
  • Electric Vehicle Supply Equipment(EVSE) is a system or an equipment to supply electric power for charging the traction batteries on the electric vehicle. EVSEs are classified with a conductive charging system and an inductive charging system by the power transfer method. Inductive charging systems are necessary to use high frequency converters to increase the output power and to reduce the size of the charging systems. In this paper, a 20kHz inverter for inductive charging system has been designed and PSCAD/EMTDC have been used to simulate the output characteristics of the 20kHz inverter.

  • PDF

Compressive Behavior of Precast Concrete Column with Hollow Corresponding to Hollow Ratio (중공비율에 따른 중공 프리캐스트 철근콘크리트 기둥의 압축거동)

  • Lee, Seung-Jun;Seo, Soo-Yeon;Pei, Wenlong;Kim, Kang-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.441-448
    • /
    • 2014
  • From several researches, recently, it was found that using hollowed precast concrete (HPC) column made more compact concrete casting in joint region possible than using normal solid PC (Precast concrete) column. Therefore, the rigidity of joints can be improved like those of monolithic reinforced concrete (RC). After filling the hollow with grout concrete, however, it is expected that the HPC column behaviors like composite structure since PC element and grout concrete have different materials as well as there is a contact surface between two elements. These may affect the structural behavior and strength of the composite column. A compressive strength test was performed for the HPC column with parameter of hollow ratio for the case with and without grout in the hollow and the result is presented in this paper. The hollow ratios in the test are 35, 50 and 59% of whole section of column. Concentrated axial force was applied to top of the specimens supported as pin connection for both ends. In addition, finite element (FE) analysis was performed to simulate the failure behavior of HPC column for axial compression. As a result, it was found that the hollow ratio did not affect the initial stiffness of HPC filled with grout regardless of the strength difference of HPC and grout. However the strength was increased inversely corresponding to the hollow ratio. The structural capacity of HPC without grout closely related to the hollow size. Especially, the local collapse governs the overall failure when the thickness of HPC is too thin. Based on these effect, a suitable equation was suggested for calculation of the compressive strength of HPC column with or without grout. FE analysis considering the contact surface between HPC and grout produced a good result matched to the test result.