• Title/Summary/Keyword: 비접촉식 검사

Search Result 62, Processing Time 0.024 seconds

Assessment of Plastic Deformation in Al6061 Alloy using Acoustic Nonlinearity of Laser-Generated Surface Wave (레이저 여기 표면파의 음향비선형성을 이용한 Al6061 합금의 소성변형 평가)

  • Kim, Chung-Seok;Nam, Tae-Hyung;Choi, Sung-Ho;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.1
    • /
    • pp.20-26
    • /
    • 2012
  • The objective of this study is to assess plastic deformation in aluminium alloy by acoustic nonlinearity of laser-generated surface waves. A line-arrayed laser beam made by high-power pulsed laser and mask slits is utilized to generate the narrowband surface wave and the frequency characteristics of laser-generated surface waves are controlled by varying the slit opening width and slit interval of mask slits. Various degrees of tensile deformation were induced by interrupting the tensile tests so as to obtain aluminum specimens with different degrees of plastic deformation. The experimental results show that the acoustic nonlinear parameter of a laser-generated surface wave increased with the level of tensile deformation and it has a good correlation with the results of micro-Vickers hardness test and electron backscatter diffraction (EBSD) test. Consequently, acoustic nonlinearity of laser-generated surface wave could be potential to characterize plastic deformation of aluminum alloy.

Arrayed-Arc Slit Design to Improve the focusing Effect of the focused Lamb Wave by Laser (레이저에 의한 집속형 램파의 집속도 향상을 위한 원호형 슬릿 설계)

  • Jhang, Kyung-Young;Kim, Hong-Joon;Sin, Min-Jea;Kim, Jae-Yeol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.2
    • /
    • pp.87-94
    • /
    • 2005
  • In recent, Lamb wave has been actively studied for non-destructive testing of plate. Among those studios, laser generation method of focused Lamb wave is expected to have high spatial resolution with advantages of non-contact testing. In this method, the laser beam is illuminated on the surface of object by through an arrayed-arc slit, and then the energy of the generated Lamb wave is concentrated at a focus of arc. This focusing effect improves the spatial resolution, which is dependant on the geometries of arrayed-arc slit. In this paper, the relationships between the parameters of arc-shaped slit and the focusing ability of the generated Lamb wave was investigated by the simulation based parametric study The results show that to improve the focusing effect, radius of illuminated laser, angle of arc and number of arcs must be increased, which minimum radius of arc and distance between arcs(=wavelength) must be decreased. These results are expected to be used as a guide to design the proper shape of slit.

Measurement of Longitudinal and Transverse Wave Speed in Solid Materials Using Immersion Ultrasonic Testing (수침 초음파 시험법을 이용한 고체의 종파와 횡파 속도의 측정)

  • Shin, Yo-Sub;Yoon, Yeo-Ho;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.1
    • /
    • pp.40-45
    • /
    • 2008
  • Immersion ultrasonic testing (UT) was used to determine elastic moduli of solid materials instead of the widely-used contact UT method. Conventionally, immersion UT is only used for determining the longitudinal wave speed. However, in this research, transverse wave speed was measured through finding transverse wave echoes caused by mode-conversion at material's boundary. Also, even in the cases when wave speeds could not be determined due to unknown thickness, Poisson's ratio was able to be calculated from the ratio of longitudinal and transverse wave speeds. This technique was verified for several materials, and it was found that higher accuracy was obtained by immersion UT method for materials either with relatively high wave speed or with relatively small Poisson's ratio. This technique thus will be suitable fur ceramics or high strength materials.

Optical technique of precision measurement using Electronic Speckle Pattern Interferometry (ESPI를 이용한 광학식 정밀 계측 기술)

  • 은재정;정영환;최평석;박해수
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.4 no.4
    • /
    • pp.40-46
    • /
    • 2003
  • In this research, we accomplished the interpreting about the vibration of the object, which is the out of plane displacement in the Electronic Speckle Pattern Interferometry(ESPI), one of the optical measuring technique. The vibrating object has a inherent nodal line, therefore we can get the information about the vibration of the object by interpreting it. we used a speaker and a cantilever plate for a measurement object, and interpreted it qualitatively by using the Time-Average ESPI. In this experimental result, the speaker has the lower mode of fringe at 550Hz, 570mV, and the higher mode of fringe at 950Hz, 570mV This ESPI is a non-destructive test, and because of using the laser at measuring, it has a high resolution. The ESPI can test vibration mode regardless of the test object size, because the area which illuminated laser is the test area.

  • PDF

A Study on Wearable Emotion Monitoring System Under Natural Conditions Applying Noncontact Type Inductive Sensor (자연 상태에서의 인간감성 평가를 위한 비접촉식 인덕티브 센싱 기반의 착용형 센서 연구)

  • Hyun-Seung Cho;Jin-Hee Yang;Sang-Yeob Lee;Jeong-Whan Lee;Joo-Hyeon Lee;Hoon Kim
    • Science of Emotion and Sensibility
    • /
    • v.26 no.3
    • /
    • pp.149-160
    • /
    • 2023
  • This study develops a time-varying system-based noncontact fabric sensor that can measure cerebral blood-flow signals to explore the possibility of brain blood-signal detection and emotional evaluation. The textile sensor was implemented as a coil-type sensor by combining 30 silver threads of 40 deniers and then embroidering it with the computer machine. For the cerebral blood-flow measurement experiment, subjects were asked to attach a coil-type sensor to the carotid artery area, wear an electrocardiogram (ECG) electrode and a respiration (RSP) measurement belt. In addition, Doppler ultrasonography was performed using an ultrasonic diagnostic device to measure the speed of blood flow. The subject was asked to wear Meta Quest 2, measure the blood-flow change signal when viewing the manipulated image visual stimulus, and fill out an emotional-evaluation questionnaire. The measurement results show that the textile-sensor-measured signal also changes with a change in the blood-flow rate signal measured using the Doppler ultrasonography. These findings verify that the cerebral blood-flow signal can be measured using a coil-type textile sensor. In addition, the HRV extracted from ECG and PLL signals (textile sensor signals) are calculated and compared for emotional evaluation. The comparison results show that for the change in the ratio because of the activation of the sympathetic and parasympathetic nervous systems due to visual stimulation, the values calculated using the textile sensor and ECG signals tend to be similar. In conclusion, a the proposed time-varying system-based coil-type textile sensor can be used to study changes in the cerebral blood flow and monitor emotions.

Application of Laser Ultrasonic Technique for Nondestructive Evaluation of Wall Thinning in Pipe (배관부 감육 손상의 비파괴 평가를 위한 레이저 초음파 기술 적용)

  • Hong, Kyung-Min;Kang, Young-June;Park, Nak-Kyu;Yoon, Suk-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.361-367
    • /
    • 2013
  • Many of the nuclear power plant pipe is used in high temperature and high pressure environment. Wall thinning frequently caused by the corrosion. These wall thinning in pipe is expected gradually increase as nuclear power become superannuated. Therefore there is need to evaluate wall thinning in pipe and corrosion defect by non-destructive method to prevent the accident of the nuclear power facility due to pipe corrosion. Especially for real-time assessment of the wall thinning that occurs in nuclear power plant pipe, the laser ultrasonic technology can be measured even in hard-to-reach areas, beyond the limits of earlier existing contact methods. In this study, the optical method using laser was applied for non-destructive and non-contact evaluation. Ultrasonic signals was acquired through generating ultrasonic by pulse laser and using laser interferometer. First the ultrasonic signal was detected in no wall thinning in pipe, then a longitudinal wave velocity was measured inside of pipe. Artificial wall thinning specimen compared to 20, 30, 40 and 50% of thickness of the pipe was produced and the longitudinal wave velocity was measured. It was possible to evaluate quantitatively the wall thinning area(internal defect depth) cause it was able to calculate the thickness of each specimen using measured longitudinal wave velocity.

Fabrication of Phased Array EMAT and Its Characteristics (위상배열 EMAT의 제작 및 특성 평가)

  • Ahn, Bong-Young;Cho, Seung-Hyun;Kim, Young-Joo;Kim, Ki-Bok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.373-379
    • /
    • 2010
  • EMAT has been applied in various fields for flaw detection and material characterization because it has noncontact property in wave generation and a good mode selectivity. Unfortunately, however, EMAT shows low signal to noise ratio relative to commercial contact transducer because of low energy conversion efficiency. If the phase matching through the control of time delay between each coil consisting of the array EMAT is accomplished, it is expected that it will be a solution for the improvement of low signal to noise ratio. In this experiment, the phased array EMATs which consists of 3 or 4 meander coils and one big magnet were fabricated for surface and vertical shear wave generation. Effect of phased delay control on signal directivity and amplitude enhancement was verified. A slit with the depth of 0.5 mm and a side-drill hole of 0.5 mm diameter were clearly detected by fabricated phased array EMATs, respectively.

A Study on the Shape Evaluation using Non-contact Electromagnetic Measurement System (비접촉식 전자기 측정 시스템에서 자성물체의 형상판정에 관한 연구)

  • Kim, Jae-Min;Yun, Seung-Ho;Won, Hyuk;Park, Gwan-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.2
    • /
    • pp.45-51
    • /
    • 2010
  • We suggest the algorithm that it detects volume and shape according with a variation of magnetic field in non-contact electromagnetic measurement system. It is possible to assess an object shape through a variation of magnetic field. The basic idea is compared a length difference with a variation of magnetic field in a detected object and a circle which modeled equivalent area. And the shape is detected to many calibration process that it is similar to signal pattern between a length difference and a variation of magnetic field in object and equivalent circle. This is the shape detection algorithm that use only the variation of magnetic field. In this paper, it has application to the shape detection algorithm about the object as hexagon, pentagon, rectangle, trigon. we can detect the object shape easily because the shape detection algorithm is only used to the variation of magnetic field.

Application and Characteristics of Ozonated Water by Injector Typed Generator (인젝터 방식 오존 제조장치의 오존수 용해특성 및 적용성 검토)

  • An, Dae-Myung;Jeong, Jae-Hoon;Kim, Jong-Chul;Jeong, Kap-Seop
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05a
    • /
    • pp.436-439
    • /
    • 2012
  • 본 연구는 오존수 제조장치에 인젝터를 이용한 오존 주입방식을 도입하여 소형화, 저전력화를 실현하고자 하였다. 오존발생기, 물-오존 혼합기(인젝터), 오존용해조, 배오존 처리기로 구성된 시스템을 제작하여 인젝터 주입방식에 의한 오존수 제조장치의 오존 용해특성과 그 적용성을 검토하였다. 오존 용해 특성으로 물-공기량에 따른 인젝터 성능, 용해조에서의 오존 용해능 등을 검토하였다. 인젝터 방식은 기존의 가압용해방식에 비하여 저농도 용해능을 보였으나, 인젝터 내부의 물-오존 접촉효율이 높아 평형농도에 도달되는 시간이 단축됨을 확인하였다. 제조된 오존수의 적용 효용성은 용존오존의 잔류시간과 미생물 살균능 검사를 통하여 실시하였다. 횡형식 인젝터 시스템에 의해 용해된 용존오존의 잔류시간이 기존의 가압용해방식에 비하여 다소 짧았으나 미생물의 살균능에는 크게 차이가 나지 않았다.

  • PDF

Development of Non-contact Detector for Broken Cords of Steel-Cord Conveyor Belt (컨베이어벨트의 비접촉식 스틸코드파선 검사장치 개발)

  • Yoo, Jae-Sang;Son, Boong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2535-2537
    • /
    • 2000
  • In order to detect and monitor the broken cords of steel-cord belt from being damaged by impact of large lump of materials and the corrosion of steel cord, we developed a non-contact magnetic coil detection system. This measures the deterioration of reinforcing cables in steel cord conveyor belt which transport the ores in raw material plant. In this research, magnetic coil sensor of broken-cord detection system has exciting part and sensing part. The broken-cord detection system is operated by supplying a transmitter coil with electric power to generate magnetic field, and then the change of induced voltage is detected in each receiver coils due to resultant magnetic flux effected by the broken steel cords at the inside of the conveyor belt. By the informations such as the position and size of the broken steel cords obtained by SCBMS(Steel Cord Belt Monitoring System), it is expected that not only the span of belt life will be lengthened, but also this system can enable operators to plan scheduled maintenance and prevent the enlargement of damaged parts in steel cord belt at an early stage

  • PDF