• Title/Summary/Keyword: 비예

Search Result 133, Processing Time 0.026 seconds

Basic Study on Lift-off Characteristics of Non-Premixed Flames of Methane-Air Jet in a Tube (관 내부 메탄-공기 분류 비예혼합 화염의 부상 특성 기초 연구)

  • Kim, Go-Tae;Kim, Nam-Il
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.4
    • /
    • pp.431-438
    • /
    • 2011
  • Flame lift-off conditions determine the operating conditions of burners. It is known that a flame can be lifted when the Schmidt number (Sc), which is the ratio of the dynamic viscosity to the mass diffusivity, is greater than unity. In this study, the flame lift-off characteristics of non-premixed flames of propane (Sc > 1) and methane (Sc < 1) in a coaxial outer air tube were experimentally compared. The experimental results indicated that stable lifted flames could be obtained even when Sc < 1 in a confined air tube. On the basis of the results of a simple numerical analysis, it was confirmed that a new flame stabilization mechanism exists in the tube. A velocity field is preferentially developed upstream of the flame, and it results in a new stabilization condition. This result can be very useful in explaining the stabilization of the flames of ordinary burners in which a flame is produced in a confined space.

Stability Enhancement by the Interaction of Diffusion Flames (다수 비예혼합 화염의 안정화 특성)

  • Kim, Jin-Sun;Lee, Byeong-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1420-1426
    • /
    • 2003
  • The stability of turbulent nonpremixed interacting flames is investigated in terms of nozzle configuration shapes and kind of fuels. Four nozzle arrangements - cross 5, matrix 8, matrix 9 and circle 8 nozzles - are used in the experiment. There are many parameters affecting flame stability in multi-nozzle flames such as nozzle separation distance, fuel flowrates and nozzle configuration etc. Key factors to enhance blowout limit are the nozzle configuration and the existence of center nozzle. Even nozzle exit velocity equal 204 m/s, flame is not extinguished when there is not a center nozzle and s/d=15.3∼27.6 in matrix-8 and circular-8 configurations. At these conditions, recirculation of burnt gas is related with stability augmentation. Fuel mole fraction measurements using laser induced fluorescence reveal lifted flame base is not located at the stoichiometric contour.

A Study on Measurement of NO Concentrations in Laminar Nonpremixed $H_2/N_2$ Flame by LIF (레이저 유도 형광법(LIF)을 이용한 층류 비예혼합 $H_2/N_2$화염에서의 NO 농도측정에 관한 연구)

  • Kim, Sun-Wook;Jin, Seong-Ho;Kim, Gyung-Soo;Park, Kyoung-Suk
    • 한국연소학회:학술대회논문집
    • /
    • 2001.06a
    • /
    • pp.133-138
    • /
    • 2001
  • In this study, quantitative nitric oxide concentration distributions are investigated in the laminar nonpremixed $H_2/N_2$ flames by laser-induced fluorescence (LIF). The measurements are taken in flames for different $N_2$ dilution ratios varying from 20${\sim}$80%, and fuel now rate is fixed as lslpm. The NO A-X (0,0) vibrational band around 226 nm is excited using a XeCl excimer-pumped dye laser. We applied same excitation line used in $CH_4$ premixed flame. Overall, NO concentration was rapidly decreased with $N_2$ addition and we could not measure the concentration any longer for $N_2$ dilution above 80%.

  • PDF

Reactants Transport Mechanism in Counterflow Nonpremixed Flame Perturbed by a Vortex (와동에 의해 교란된 대향류 비예혼합화염의 반응물 전달기구)

  • Oh, Chang-Bo;Lee, Chang-Eon
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1690-1696
    • /
    • 2003
  • A two-dimensional direct numerical simulation is performed to investigate the flame structure of $CH_4/N_2$-Air counterflow nonpremixed flame interacting with a single vortex. The detailed transport properties and a modified 16-step augmented reduced mechanism based on Miller and Bowman's detailed chemistry are adopted in this calculation. The results show that an initially flat stagnation plane, where an axial velocity is zero, is deformed into a complex-shaped plane, and an initial stagnation point is moved far away from vortex head when the counterflow field is perturbed by the vortex. It is noted that the movement of stagnation point can alter the mechanism of reactants (fuel and oxidizer) fluxes into the flame surface, and then can alter the flame structure.

  • PDF

Effect of Oxygen Enriched Air on the Combustion Characteristics in a Coaxial Non-Premixed Jet ( I ) - Lift-off and Flame Stability - (산소부화공기가 동축 비예혼합 제트의 연소특성에 미치는 영향 (I) - 화염의 부상과 안정성)

  • Kwark, Ji-Hyun;Jeon, Chung-Hwan;Chang, Young-June
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.2
    • /
    • pp.160-166
    • /
    • 2004
  • Combustion using oxygen enriched air is known as a technology which can increase flame stability as well as thermal efficiency due to improving the burning rate. Lift-off, blowout limit and flame length were examined as a function of jet velocity, coflow velocity and OEC(Oxygen Enriched Concentration). Blowout limit of the flame below OEC 25% decreased with increase of coflow velocity, but the limit above OEC 25% increased inversely. Lift-off height decreased with increase of OEC. In particular, lift-off hardly occurred in the condition above OEC 40%. Flame length of the flames above OEC 40% was increased until the blowout occurred. Great flame stability was obtained since lift-off and blowout limit significantly increased with increase of OEC.

The Influence of $C_2HCl_3$ on the $CH_4/Air$ Counterflow Nonpremixed Flames (메탄/공기 대향류 비예혼합화염에서 $C_2HCl_3$의 영향)

  • Lee, Ki-Yong
    • Journal of the Korean Society of Combustion
    • /
    • v.3 no.2
    • /
    • pp.41-50
    • /
    • 1998
  • Numerical simulations of nonpremixed $CH_4/C_2HCl_3$(Trichloroethylene, TCE)/Air flames are conducted at atmospheric pressure in order to understand the effect of hydrocabon bound chlorine on methane/air flames. A chemical kinetic mechanism is employed, the adopted scheme involving 48 gas-phase species and 445 elementray reaction steps containing 223 backward reactions. The calculated temperature, velocity, and critical strain rate are compared with the experiments for the flame (16.1% TCE by Vol.) estabilished at a strain rate of $175s^{-1}$. Whereas there is overall good agreement between predictions and the measurements, it appears that the critical strain rate is higher than measured, and some areas of further refinement in the kinetic mechanism are required.

  • PDF

Fully coulpled CMC modeling for three-dimensional turbulent nonpremixed syngas flame (CMC 모델을 이용한 난류 비예혼합 Syngas 화염장 해석)

  • Kim, Gun-Hong;Lee, Jung-Won;Kim, Yong-Mo;Ahn, Kook-Young
    • 한국연소학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.111-120
    • /
    • 2006
  • The fully coupled conditional moment closure(CMC) model has been developed to realistically simulate the structure of complex turbulent nonpremixed syngas flame, in which the flame structure could be considerablyl influenced by the turbulence, transport history, and heat transfer as well. In order to correctly account for the transport effect, the CMC transport equations fully coupled with the flow and mixing fields are numerically solved. The present CMC approach has successfully demonstrated the capability to realistically predict the detailed structure and the overall combustion characteristics. The numerical results obtained in this study clearly reveal the importance of the convective and radiative heat transfer in the precise structure and NOx emission of the present confined combustor with a cooling wall.

  • PDF

Numerical Analysis for the Detailed Structure and the Soot Formation Mechanism in Counterflow Ethylene-Air Nonpremixed Flame (대향류 에틸렌/공기 비예혼합 화염의 구조 및 Soot 생성 메커니즘 해석)

  • 임효준;김후중;김용모
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.5
    • /
    • pp.40-54
    • /
    • 1999
  • The flame structure and soot formation in the counterflow Ethylene-Air nonpremixed flame are numerically analyzed. The present soot reaction mechanism involves nucleation, surface growth, particle coagulation, and oxidation steps. The gas phase chemistry and the soot nucleation, surface growth reactions are coupled by assuming that the nucleation and soot mass growth has the certain relationship with the concentration of benzene and acetylene. In terms of the centerline velocity and the soot volume fraction, the predicted results are compared with the experimental data. The detailed discussion has been made for the sensitivity of model constants and the deficiencies of the present model. Numerical results indicated that the acetylene addition to the soot surface plays the dominant role in the soot mass growth for the counterflow nonpremixed flame.

  • PDF

Numerical Analysis for the Soot Formation Processes in Acetylene-Air Nonpremixed Turbulent Jet Flame (아세틸렌/공기 비예혼합 난류 제트화염의 Soot 생성에 대한 수치해석)

  • 김후중;김용모;윤명원
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.6
    • /
    • pp.80-89
    • /
    • 2002
  • The flame structure and soot formation in Acetylene-Air nonpremixed jet flame are numerically analyzed. We employed two variable approach to investigate the soot formation and oxidation processes. The present soot reaction mechanism involves nucleation, surface growth, particle coagulation, and oxidation steps. The gas phase chemistry and the soot nucleation, surface growth reactions are coupled by assuming that the nucleation and soot mass growth has the certain relationship with the concentration of pyrene and acetylene. We also employed laminar flamelet model to calculate the thermo-chemical properties and the proper soot source terms from the information of detailed chemical kinetic model. The numerical and physical model used in this study successfully predict the essential features of the combustion processes and soot formation characteristics in the reaction flow field.

Combustion Characteristics of Non-premixed VIStA Burner in Once-Through-Type Boiler (관류보일러 연소실에서 비예혼합 VIStA 버너의 연소 특성)

  • Ahn, Joon;Kim, Hyouck-Ju;Choi, Kyu-Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.5
    • /
    • pp.547-552
    • /
    • 2010
  • A modified VIStA (vortex inertial staged air) burner was developed and used in a once-through-type boiler. For safety, the combustion in this burner is of the non-premixed type. An air damper is installed to control the distribution of air to each combustion chamber. The effects of the air-fuel ratio and air distribution on NOx formation were investigated. The newly modified VIStA burner gives NOx reduction effect by maximum 20% in the combustion chamber of a boiler, while it yields more uniform flame than the conventional burner.