• Title/Summary/Keyword: 비상 탐지

Search Result 27, Processing Time 0.022 seconds

Implementation of Emergency Evacuation Support System in Panic-type Disaster (돌발성 재해에 대비한 긴급 피난 지원 시스템의 구현)

  • Hwang, Jun-Su;Choi, Young-Bok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.7
    • /
    • pp.1269-1276
    • /
    • 2016
  • Recently, natural disasters including earthquakes, tsunamis, floods, and snowstorms, in addition to disasters of human origin such as arson, and acts of terror, have caused numerous injuries and fatalities around the world. During such disasters, victims need to obtain information such as the exact location of the disaster and appropriate evacuation routes in order to relocate to safe areas. In this study, We propose the algorithm for Emergency Rescue Evacuation Support System(ERESS). In case a emergency disaster occurs, ERESS is possible to detect it quickly using through the movement of people. The mobile terminal analyzes behavior and location of indoor pedestrian. And it sends the result to the server. The server determines whether an emergency situation occurred or not based on the received transmission information. When an emergency situation occurs, the server will notify it to the mobile terminal. Then, indoor pedestrian conduct emergency evacuation using mobile terminal.

Introduction of Fire Protection Technology and Its Design Method of Offshore Facilities (해양플랜트의 방화대책 및 설계기술 소개)

  • Koo, Myeong Jun;Choi, Jae Woong;Yoon, Ho Byung
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.1
    • /
    • pp.49-57
    • /
    • 2013
  • The dimensioning accidental loads have been selected through suitable quantitative risk assessment and generally utilized important factors for offshore facility design. The fire hazard can be quantified with dimensioning fire loads. The main purposes of fire protection are to maintain the functionality of safety systems within evacuation period and to prevent the escalation from initial fire to uncontrolled catastrophic fire. This paper introduces the applications and the design methods of active and passive fire protections as representative measures of fire protection of offshore facilities. The passive fire protection requires the high initial installation cost and much difficulty on the operation of facilities and their maintenance. The oil major clients have asked the design contractors of offshore facilities to optimize the amount of passive fire protection with relevant engineering technology recently.

Analysis of Building Characteristics and Temporal Changes of Fire Alarms (건물 특성과 시간적 변화가 소방시설관리시스템의 화재알람에 미치는 영향 분석 연구)

  • Lim, Gwanmuk;Ko, Seoltae;Kim, Yoosin;Park, Keon Chul
    • Journal of Internet Computing and Services
    • /
    • v.22 no.4
    • /
    • pp.83-98
    • /
    • 2021
  • The purpose of this study to find the factors influencing the fire alarms using IoT firefighting facility management system data of Seoul Fire & Disaster Headquarters, and to present academic implications for establishing an effective prevention system of fire situation. As the number of high and complex buildings increases and former bulidings are advanced, the fire detection facilities that can quickly respond to emergency situations are also increasing. However, if the accuracy of the fire situation is incorrectly detected and the accuracy is lowered, the inconvenience of the residents increases and the reliability decreases. Therefore, it is necessary to improve accuracy of the system through efficient inspection and the internal environment investigation of buildings. The purpose of this study is to find out that false detection may occur due to building characteristics such as usage or time, and to aim of emphasizing the need for efficient system inspection and controlling the internal environment. As a result, it is found that the size(total area) of the building had the greatest effect on the fire alarms, and the fire alarms increased as private buildings, R-type receivers, and a large number of failure or shutoff days. In addition, factors that influencing fire alarms were different depending on the main usage of the building. In terms of time, it was found to follow people's daily patterns during weekdays(9 am to 6 pm), and each peaked around 10 am and 2 pm. This study was claimed that it is necessary to investigate the building environment that caused the fire alarms, along with the system internal inspection. Also, it propose additional recording of building environment data in real-time for follow-up research and system enhancement.

Security Measures against Assembly and Demonstration during International Conference - the Case of the Nuclear Security Summit - (국제회의 시 집회시위에 관한 안전관리 방안 - 핵 안보정상회의 개최를 중심으로 -)

  • Lee, Sun-Ki
    • Korean Security Journal
    • /
    • no.29
    • /
    • pp.193-222
    • /
    • 2011
  • Our country successfully hosted the G20 summit in Seoul in November, 2010. Afterwards, however, the Yeonpyungdo shelling incident took place by the North, and the North Korean nuclear issue have strained interKorean relations. Our country is going to host the nuclear security summit, which is of great significance at this point of time. The nuclear security summit is to be attended by 47 countries. The participant countries of this summit is larger in number than those of the ASEM, APEC and the G20 summit that our country has ever hosted. That is a large-scale international conference that invites the UN, the IAEA and the EU, which are three major nuclear-related international organizations. A successful hosting of the nuclear security summit will serve as an opportunity to boost our country's national prestige, and is likely be beneficial to the settlement of the North Korean nuclear issue. Like other international submits in foreign countries, however, violent anti-globalization demonstrations are expected to occur when the nuclear security summit is held in April next year. The purpose of this study was to make a case analysis of demonstrations during multilateral international conferences hosted by foreign countries over ten years between 1999 and 2009, to examine the controversial points over the demonstrations, and ultimately to seek ways of ensuring safety against possible assemblies and demonstrations during the forthcoming nuclear security summit, which is scheduled to be held in April next year. The findings of the study on feasible security measures are as follows: First, information and intelligence gathering should be reinforced, and the inspection should be stepped up. Second, pacification among domestic NGOs and the supplementation of the existing legal devices are required. Third, publicity should be strengthened. Fourth, riot police officers should be selected as early as possible to bolster their education and training, and more reinforced emergency measures should be taken. It's needed to seek assistance from the military as one of emergency measures, and national defense readiness should be bolstered across the nation in collaboration with the Ministry of National Defense when the summit is near at hand. Finally, CBR countermeasures should be taken in preparation for CBR terrorism.

  • PDF

A Study on Optimal Operation for Flare systems (플레어 시스템의 최적 운영방안에 대한 연구)

  • Song, Bang-Un;Bok, Hyeong-Jun;Woo, In-Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.1-7
    • /
    • 2019
  • Most oil refineries and chemical plants have flare systems designed to mitigate pressure rises in process facilities in case of emergencies that require the release of large amounts of gas due to sudden process shutdowns such as power outages. However, the rise of the flame of the flare system causes civil complaints from residents around the factory due to visible pollution, and economic loss occurs in the company, which requires constant management. In this study, two items were diagnosed and analyzed in order to derive the optimal operation method of flare system. First, to detect the cause of the rise in flame height, the acoustic leak detector was used to check gas leaks in safety valves and pressure control valves. Second, to identify the cause of flame instability, the pulsation phenomenon was diagnosed through the CFD simulation and modeling experiments of the sealing drum. By confirming the leak at 4.3% of the safety valve and 10% of the pressure control valve, the cause of abnormal sparking was derived. The information presented in this study can be easily applied to any company that has a flare system, and is expected to prevent complaints and product loss.

Solid Chemical Material Site Analysis Research of Event Site (사건현장의 고체상 화학물질 현장분석 연구)

  • Kim, Sungbum;Noh, Hyeran;Lee, Jinseon;Kim, Jungmin;Cho, Munsik;Park, Choonhwa;Chun, Kwangsoo;Ahn, Seungyoung;Seok, Gwangseol
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.3
    • /
    • pp.304-309
    • /
    • 2012
  • National Institute of Environmental Research has Portable FT-IR(Fourier Transform Infrared Spectroscopy, A2 Technologies, U.S.A.) and Portable XRD(X-ray Diffraction, Olympus Innov-X co., U.S.A.) for the analysis of the solid sample rapidly on the spot where chemical terror accident took place and the portable equipments are operating now. However, we need a series of the analysis procedures for an efficient application of the equipments and getting the rapid analytical value about the investigation and sampling on the spot. And the accuracy of the portable equipments' analytical value is high but the application of them in an emergency is low because we are lack of the procedures about field-centered analysis and the usage. Therefore we would like to organize the result of this research about field analysis and the procedures of the solid portable equipments. And we also would like to apply it to the field of chemical terror accident.

A Study Security Measures for Protection of VIP in the G20 Summit (G20 정상회의 시 주(主)행사장에서의 VIP 안전대책 방안에 관한 연구)

  • Lee, Sun-Ki;Lee, Choong-Soo
    • Korean Security Journal
    • /
    • no.24
    • /
    • pp.91-123
    • /
    • 2010
  • The threat factors available for occurrence given G20 Summit Meeting are expected leader terrorism, hostage terrorism, bomb terrorism, public facilities terrorism, and aircraft terrorism. As for the threat groups, which are expected in Korea, the North Korea, Islam extremist group, and the group such as NGO organization of being opposed to international meeting are regarded as having possibility of causing hazard. Thus, the purpose of this study is to suggest VIP Security-measure plans in the main site in preparation for G20 Summit Meeting. Accordingly, each country in the world is adopting 'the principle of Triple Ring' in common. Thus, it elicited a coping plan by 1st line(inner ring) 2nd line(middle ring) 3rd line(outer ring) based on this principle, and proposed even an opinion together that will need to be reflected in light of policy for the VIP security measures. In conclusion, as for the VIP Security-measure plans in the main site in preparation for G20 Summit Meeting, In the inner ring(safety sector), first, an intercepting measure needs to be devised for a spot of getting into and out of vehicles given the Straight Street. Second, the Walking Formation needs to be reinforced boldly in the exposed area. In the middle ring(security sector), first, the control plan needs to be devised by considering particularity of the main site. Second, there is necessity for adopting the efficient security badge operation plan that is included RFID function within security badge. In the outer ring(aid protective sector), first, there is necessity of preparing for several VIP terrorisms, of collecting information and intelligence, and of reinforcing the information collection system against terrorism under the cooperation with the overseas information agency. Second, the urgent measure training in time of emergency needs to be carried out toward security agent event manpower. Third, to maintain the certain pace in VIP motorcade, the efficient traffic control system needs to be operated. Finally, as for what will need to be reflected in light of policy for VIP security measures, first, there is necessity for allowing VIP residence to be efficiently dispersed to be distributed and controlled. Second, there is necessity for allowing impure element to misjudge or attack to be failed by utilizing diverse deception operations. Third, according to the reorganization in North Korea's Organization of the South Directed Operations, the powerful 'military-support measure' needs to be driven from this G20 Summit Meeting. For this, the necessity was proposed for further reinforcing the front back defense posture under the supervision of the Ministry of National Defense and for positively coping even with detecting and removing poison in preparation for CBR (chemical, biological, and radio-logical) terrorism.

  • PDF