• Title/Summary/Keyword: 비상용량

Search Result 77, Processing Time 0.026 seconds

Improving the water yield capabilities using reservoir emergency storage and water supply adjustment standard (합천댐의 비상용량 및 용수공급 조정기준을 활용한 용수공급능력 제고)

  • Ahn, Jaehong;Lee, Youngmok;Yi, Jaeeung
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.12
    • /
    • pp.1027-1034
    • /
    • 2016
  • One of the most important purpose of multi-purpose reservoir is storing a large amount of water for utilization in a dry season. However, multi-purpose reservoirs that were constructed according to the limited hydrologic information available at the time of construction may encounter problems such as decreased water inflow due to climate change and an inability to cope with a water shortage. To solve these problems, in 2015, the Ministry of Land, Infrastructure and Transport suggested a revised water supply standard in case of water shortage for reservoirs. However, the revised standard has not been sufficiently discussed to determine its effectiveness. In addition, multi-purpose reservoirs in South Korea have secured and stored water for emergencies, but there is currently no way to utilize the stored water. Determining how to utilize the stored water effectively may be a useful method for preparing drought. Therefore, this article discusses the revised water supply standard as it relates to a water shortage in reservoirs and a method of utilizing the water stored for emergencies in multi-purpose reservoirs. The options for utilizing the water storage were evaluated using a water shortage safety degree index, and the results showed that the options may slightly and limitedly increase the water supply capacity. However, the evaluation also showed that a complex application of two options may overcome the exisiting problem and to supply water more effectively.

A Study on Inrush Current Reduction of Induction Motor using Emergency Generator (비상발전기를 이용한 유도전동기의 기동전류 저감에 대한 연구)

  • Choi, Eun-Kyung;Kim, Byeong-Kak;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.443-444
    • /
    • 2020
  • 비상발전기를 이용한 독립 전원시스템에서 유도전동기를 직입기동 할 경우 큰 돌입전류로 인하여 과대한 발전기 용량이 요구되고 있으며, 이를 개선하기 위해 다양한 소프트-스타트 기동 방법이 사용되고 있다. 본 논문은 비상발전시스템에서 유도전동기 기동 시 발생하는 돌입전류를 저감하기 위해 비상발전기를 이용한 소프트-스타트 기동 방식을 제안한다. 또한 제안된 방식이 타당성을 검증하기 위해 시뮬레이션을 한 결과 제안된 방법을 적용 시 돌입전류가 저감하였다.

  • PDF

가압경수로 안전주입계통 최적화를 위한 LBLOCA 영향 고찰

  • 정재훈;이상종;권태순;반창환;황순택
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.321-327
    • /
    • 1996
  • 울진 3,4호기 안전주입계통의 용량 변화가 가상적인 대형파단 냉각재상실사고 거동에 미치는 현상을 파악하여 이를 후속호기 계통설계 및 사고해석을 위한 안전주입계통의 최적화에 활용하고자 하였다. 본 논문에서 해석은 USNRC 가 승인한 ABB-CE 평가 모델을 적용하여 수행하였으며, 이의 결과 대형파단 사고시 안전주입탱크 용량을 울진 3,4호기의 60% 까지 줄였을 때에도 경수로용 비상노심냉각계통 허용기준$^{(1)}$ 을 만족하였다. 또한 저압 안전주입계통을 고려하지 않았을 경우, 안전주입탱크 용량을 울진 3,4호기의 60%, 고압 안전주입유량을 울진 3,4호기의 175%로 가정했을 때 경수로용 비상노심냉각계통 허용기준을 만족함을 확인하였다.

  • PDF

The Operation Method of Emergency Power Supply System in Bipolar LVDC Using Emergency Generator and ESS (비상발전기와 ESS를 이용한 양극성 저압 직류배전에서의 비상 전력 공급 시스템 운영 방법)

  • Kang, Kyung-Min;Kang, Jin-Wook;Song, Jun-Ho;Lee, Hoon;Kwon, Yong-Hoon;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.180-182
    • /
    • 2018
  • 직류배전 시스템은 신재생에너지 및 ESS(Energy Storage System)와의 결합으로 높은 에너지 이용효율을 가질 수 있다. 이러한 직류배전 시스템은 기존 교류계통을 통해 구성되며, 다양한 디지털 부하가 연계되므로 교류계통 및 메인 PCS(Power Conversion System)에 문제가 발생했을 때를 대비하여 비상 전력 공급 시스템이 필수적으로 고려되어야 한다. 최근 직류배전에서 비상 전력 공급 시스템으로 큰 관심을 받고 있는 ESS는 초기 설치비용, 용량, 수명 등의 문제로 인해 단일로 비상 전력 공급 시스템을 구성하기에 어려움이 있다. 때문에 기존에 이미 많이 설치되어 있는 비상발전기의 적용이 검토되어야 한다. 본 논문에서는 비상발전기와 ESS를 활용하여 양극성 저압직류배전에서 정전과 같은 사고 상황 발생 시 직류배전망의 전압을 빠르게 안정시킬 수 있는 시스템과 그 운영기법을 제안하였고, PSIM 시뮬레이션을 통하여 타당성을 검증하였다.

  • PDF

Design of Transport Network on the Digital TRS System for the Emergency and Disaster Communication (비상재난통신을 위한 디지털 TRS 시스템의 전달망 설계)

  • Hong, Wan-Pyo;Lee, Soon-Hwa
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.6
    • /
    • pp.555-562
    • /
    • 2010
  • Currently digital TRS is providing the voice-oriented service based on stat-tree topology of 2.5G. As result of that, it has alimitation to accept the wide band multimedia services. Therefore, this paper designed the mesh topology based on packet networkand proposed the algorism of dynamic path establishment based on priority. In korea case, we confirmed that hop numbers priority base is more reasonable than distance priority base. And counted the trunk traffic including redundancy traffic to prevent the bottlenect situation and trouble. Also analysed the bandwidth between network management centers of backbone and access.

Retrofit of Safety Class 1E Emergency Diesel Generator in Nuclear Power Plant (원자력발전소 안전 등급 1E 비상디젤발전기 리트로피트 (Retrofit))

  • Kim, Chul-Hyo;Chang, Choong-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.689-690
    • /
    • 2015
  • 국내 최초 원전인 고리1호기는 지난 2007년 30년의 운전수명을 마친 뒤 정부의 안전점검을 거쳐 10년간 연장운전에 들어갔다. 이 과정에서 원전의 비상 전원 계통 신뢰성 확보를 위해 설계수명을 초과한 35년 된 노후 비상디젤발전기(Emergency Diesel Generator, 이하 EDG)를 지난 2013년 4월부터 9월까지 약 6개월에 걸쳐 교체하게 되었으며, 국내 원전 EDG 총 42대 중 18대가 20년 넘게 운영되고 있고, 2025년까지 고리 1호기를 후속으로 월성1호기, 고리2호기, 고리3호기, 고리4호기, 한빛1호기 순으로 40년 승인된 운전 인허가 기간이 만료된다.[1]. 본 연구에서, Class 1E EDG 교체 시 신규 EDG 설계기준, 용량결정, 해석 및 평가에 대한 기술적 방법들을 고리1호기의 사례를 통해 고찰하였다.

  • PDF

가압경수로 안전주입계통 최적화를 위한 SBLOCA 영향 고찰

  • 이남호;허재영;배규환;이상종;황순택
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.519-524
    • /
    • 1996
  • 울진 3,4호기 안전주입계통의 용량 변화가 가상적인 소형냉각재상실사고 거동에 미치는 민감도 해석을 수행하여 이를 System 80 설계발전소의 CESSAR-F 와 비교함으로써 후속호기 계통설계 및 사고해석을 위한 안전주입계통의 최적화에 활용코자 하였다. 본 논문에서 해석은 USNRC가 승인한 ABB-CE 평가 모델을 적용하여 수행하였으며, 이의 결과 소형 파단 사고시 안전주입탱크의 용량 및 고압 안전주입유량을 울진 3,4호기의 60% 까지 줄였을 때에도 경수로용 비상노심냉각계통 허용 기준$^{(1)}$ 을 만족함을 확인하였다.

  • PDF

The Combination Style Emergency Lighting Fixture which Considers a Dark Adaptation (암순응을 고려한 겸용형 비상조명등)

  • Yoon, Cheol-Gu;Choi, Hong-Kyoo;Lee, Guen-Moo;Kim, Young-Kyu;Kim, Jong-Soo;Chang, Min-Kee;Hwang, Sang-Gu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.145-148
    • /
    • 2009
  • It is sharply decreasing from several hundred[lx] to 1.0[lx] when it turn on the emergency lamps. The sharply decreasing illuminance makes peoples to have dark adaptation for long time. And they were with fear and confused. It also causes secondary accidents by people who take a mistake. This paper studied the combination style emergency lighting fixture to improve a problem of dark adaptations. But it was made an assumption that same conditions of battery capacity and a number of emergency lamps.

  • PDF

A Study on the Emergency and Recovery AC/DC Combination Lamps in the Electric Substations (변전소의 AC/DC 겸용 비상 및 복구 등에 관한 연구)

  • Park, Joon-Yeol;An, Youn-Ki;Kim, Jong-Soo;Shin, Hye-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.27-34
    • /
    • 2010
  • This study is for the improvement in the equipment environment of the emergency and recovery lamps in electric substations. To solve problem about the weak illuminance of existing emergency lamps, the AC/DC combination lamps and switches are reviewed. And the improved illuminance standards that are divided each room's purpose are suggested. It is based on a nuclear power plant's Illuminance Standards and a safety lamp's Illuminance Standards of Illuminance Standards Korean Industrial Standards - KS A 3011 -, not just 5~10[%] in according with normal lamp's illuminance. Lastly, The experiments are conducted to prove the suggested contents on this study. Consequently, a battery capacity is not increased, but illuminance of emergency and recovery lamps can be increased.