• Title/Summary/Keyword: 비매설

Search Result 225, Processing Time 0.021 seconds

Determination of the Frozen Penetration Depth of a Freezing Soil Medium including a Pipeline in a Closed System (파이프라인이 매설된 폐쇄형 동결토의 동결심도 결정)

  • Song Weon-Keun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.17 no.4
    • /
    • pp.451-458
    • /
    • 2004
  • The study was focused on the development of computational scheme in three dimensional configurations by applying effective heat capacity model to the numerical procedure in order to predict the temperature profiles of a buried pipeline and the frozen penetration depth(FPD) of a freezing soil medium. To realize this, the investigator conducted the unsteady state heat transfer analysis, using the commercial code ABAQUS, for the freezing granite soil medium including a pipeline in a closed system. The proposed model took into consideration the phase change effect of in situ pore water in the frozen fringe. The comparison of results obtained by the proposed model and the actual performances was valuable in establishing a level of confidence in the application of introduced theory.

Contact Diagnosis between Pipeline and Steel casing (매설배관과 압입관의 접촉 부위 진단)

  • 박경완;이선엽;전경수
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.05a
    • /
    • pp.38-38
    • /
    • 1999
  • 매설배관은 도로 혹은 철길올 횡단하는 경우와 같이 굴착에 의한 시공이 불가능한 경우에 압업관을 사용하여 시공하며 이러한 압업관은 배관이 토양의 하중으로부터 안 전하게 유지되도록 하는 기능도 한다. 압엽관은 배관과 접촉이 되지 않도록 절연체 를 배관과의 사이에 삽업올 하도록 규정되어 있는데 여러 가지 이유로 배관과 접촉이 되기도 한디 배관과 압업관이 전기적으로 접촉되면 배관을 방식하기 위한 방식전류 를 압입관에 빼앗기게 되고 압업관 내부의 배관은 비방식 상태에 놓이게 되어 부석이 일어날 가능성이 높다. 본 연구는 실제 매설배관 현장에서 배관과 압입관의 접촉여부 에 대하여 조사한 방법 및 결과에 대한 것이다. 본 연구에서는 압업관의 접촉여부를 확인하기 위하여 다음과 같은 방법을 사용하 였다. 첫째. 배관과 압입관의 방식선위를 단순하게 측정하는 것이다. 배관과 압업관 의 전위가 같은가 다른가를 측정하는 방법이다. 둘째, 배관의 방식전류를 on, off하면서 배관과 압입판의 전위거동을 살펴보는 것이다. 셋째, 배관과 압업관을 언위적으로 접촉시켜 흐르는 전류량을 확인함으로써 접촉여부를 확인할 수 있었다. 넷째 배관을 따라 흐르는 방삭전류량을 측정하였다. 이상과 같은 방법을 사용하여 배판과 접촉된 압압관을 확인할 수 있었다. 접촉된 압입관에서 접촉지점을 확인하기 위하여 배관과 압입관 사이에 전류를 인가하고 압입 관의 양단의 배판 사이의 전위 변화를 측정하여 그 전위변화값과 인가한 전류값을 통 하여 계산된 저항올 배관의 길이로 환산하여 대략적인 접촉지점을 확인할 수 있었다.

  • PDF

Visualization Technology of GIS Associated with Seismic Fragility Analysis of Buried Pipelines in the Domestic Urban Area (국내 도심지 매설가스배관의 지진취약도 분석 연계 GIS 정보 가시화 기술)

  • Lee, Jinhyuk;Cha, Kyunghwa;Song, Sangguen;Kong, Jung Sik
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.2
    • /
    • pp.177-185
    • /
    • 2015
  • City-based Lifeline is expected to cause significant social and economic loss accompanied the secondary damage such as paralysis of urban functions and a large fire as well as the collapse caused by earthquake. Earthquake Disaster Response System of Korea is being operated with preparation, calculates the probability of failure of the facility through Seismic Fragility Model and evaluates the degree of earthquake disaster. In this paper, the time history analysis of buried gas pipeline in city-based lifeline was performed with consideration for ground characteristics and also seismic fragility model was developed by maximum likelihood estimation method. Analysis model was selected as the high-pressure pipe and the normal-pressure pipe buried in the city of Seoul, Korea's representative, modeling of soil was used for Winkler foundation model. Also, method to apply developed fragility model at GIS is presented.

A Study on the Compressible Fluid Leak Position Detection of Buried Pipelines (매설배관 내의 압축성 유체 누설 위치 검출에 관한 연구)

  • Lee, Jeong-Han;Kim, Hyung-Jin;Yoon, Doo-Byung;Park, Jin-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.5
    • /
    • pp.40-49
    • /
    • 2016
  • When a leak occurs in the buried pipelines, The leak locations are able to detected by using the vibration sensors. These leak detection system, intended for incompressible fluid, such as water, are of using the wave propagation velocity and a signal arrival time delay between the sensors. In this paper, to develop a leak location detection system for a compressible fluid such as gas, the conventional detection methods have been studied, improved, and verified through the experiment using the compressed air. It confirmed that it is possible to detect the leak location for compressible fluid in the buried pipelines and to be applicable to the development of a leak location detection system in buried pipelines for gas.

Durability Evaluation of a Buried Expansion Joint of Buried Folding Lattice Type (BFL형의 매설형 신축이음장치의 내구성 평가)

  • Jwa, Yong-Hyun;Park, Sang-Yeol;Kim, Seok-Hyun
    • International Journal of Highway Engineering
    • /
    • v.13 no.2
    • /
    • pp.9-20
    • /
    • 2011
  • Most of domestic expansion joint system was applied by exposed expansion joint system. There are cases where it is damaged by driving. As the result noise and impact happened, and the social cost due to frequent repair works is increasing. So based on the Asphalt Plug Joint(APJ) system that applied in the United States and Europe, new buried expansion joint system was lately developed a system of Buried Folding Lattice Joint(BFLJ) that changed substructure. In this research, we have tested for durability and flexibility performance of buried expansion joint system that based on the type of asphalt mixture. Also we have evaluated for durability of BFLJ system against vehicle load using accelerated pavement testing. As a result of the experiment, the developed BFLJ system gives high flexibility performance and resolves transformation concentration along the joint section more than APJ system. Also it could be seen that the BFLJ system could overcome the disadvantages of APJ and prevent early damage. Because surface deflection of BFLJ system against vehicle load was measured low, and sub system in the buried expansion joint system was not damaged against vehicle load.

A Study on the Performance Evaluation of a Tele-operated Hume Concrete Pipe Laying Machine (흄관매설 자동화 장비의 성능평가에 관한 연구)

  • Ryu Yeon-Taek;Park Sang-Jun;Byun Woong-Ho;Kim Young-Suk;Lee Jun-Bok
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.634-637
    • /
    • 2003
  • A tele-operated hume concrete pipe laying machine has been developed to solve several problems on safety, quality, productivity, etc. It is required to propose a performance evaluation model and methodology in order to measure productivity, economic feasibility, quality and safety. The primary objective of this study is to propose a model and methodology for the performance evaluation of the developed tele-operated hume concrete pipe laying machine. Furthermore, this study evaluates its performance compared with the existing hume pipe laying work by using data which obtained in field trials. It is anticipated that the proposed model and methodology might be effectively used in analyzing the performance of other automation robots.

  • PDF

Development of the Evaluation Model for Performance Analysis of a Tele-operated Hume Concrete Pipe Laying Machine (흄관매설 자동화 장비의 성능분석을 위한 평가모델의 개발)

  • Ryu Yeon-Taek;Park Sang-Jun;Lee Jeong-Ho;Jeong Myung-Hoon;Kim Young-Suk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.5 no.1 s.17
    • /
    • pp.157-167
    • /
    • 2004
  • In developing an automated construction system, it is essential to propose a performance evaluation model and methodology, which can measure productivity, quality, safety and economic feasibility in order to verify its superiority. Recently, a tele-operated hume concrete pipe laying machine has been developed to solve several problems related to safety, quality, productivity in conventional method. The primary objective of this study is to propose a model and methodology for the performance evaluation of the developed tele-operated hume concrete pipe laying machine. Furthermore, this study evaluates the automation machine's performance compared with the existing hume pipe laying work by using data which obtained in many field trials. It is anticipated that the proposed model and methodology might be effectively used in analyzing the performance of other automation robots.

High resolution groud penetrating image radar using an ultra wideband (UWB) impulse waveform (초광대역 임펄스를 이용한 고해상도 지반탐사 이미지 레이더)

  • Park Young-Jin;Kim Kwan-Ho;Lee Won-Tae
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.11
    • /
    • pp.101-106
    • /
    • 2005
  • A ground penetrating image radar (GPR) using an ultra wideband (UWB)impulse waveform is developed for non destructive detection of metallic pipelines buried under the ground. Dielectric constant of test field is measured and then a GPR system is designed for better detection up to 1 meter deep. By considering total path loss, volume of complete system, and resolution, upper and lower frequencies are chosen. First, a UWB impulse for the frequency bandwidth of the impulse is chosen with rising time less than 1 ns, and then compact planar UWB dipole antenna suitable for frequency bandwidth of a UWB impulse is designed. Also, to receive reflected signals, a digital storage oscilloscope is used. For measurement, a monostatic technique and a migration technique are used. For visualizing underground targets, simple image processing techniques of A-scan removal and B-scan average removal are applied. The prototype of the system is tested on a test field in wet clay soil and it is shown that the developed system has a good ability in detecting underground metal objects, even small targets of several centimeters.

Development of Curve Fitted Equation about Dynamic Response Analysis of a Buried Concrete Pipelines (콘크리트 매설관의 동적응답해석에 대한 곡선적합식의 개발)

  • Jeong Jin-Ho;Kim Sung-Ban;Ahn Myung-Seok
    • Explosives and Blasting
    • /
    • v.24 no.1
    • /
    • pp.9-19
    • /
    • 2006
  • The objective of this study is to propose curve fitted equations that can facilitate calculations and improve a practical applicability when the seismic performance of buried pipelines needs to be evaluated. The curve fitted equations are derived based on the evaluation of the dynamic responses of concrete pipe with a boundary condition of fixed-free ends. To study the dynamic response of underground pipe, the numerical analysis program developed in the previous research has been used. The location of maximum strain has been determined through dynamic analyses for a boundary condition of fixed-free ends. Then $wavelength{\lambda}$ of 5-1000(m) and propagation velocity(Vs) of 100-2000(m/s) have been applied at the location of maximum strain and the unit srain curve with the changes of the $wavelength{\lambda}$ and propagation velocity(Vs) has been obtaind. Non-linear least-square regression has been used to develop highly applicable curve fitted equations and various types of exponential regression equations have been checked out. Thus curve fitted equations and necessary coefficients with best results are suggested.

Finite Element Analysis on Polyethylene Gas Pipes under External Loadings (폴리에틸렌 가스배관의 외부 하중에 대한 유한요소 해석)

  • Kil, Seoog-Hee;Park, Kyo-Shik;Kim, Ji-Yoon
    • Journal of Energy Engineering
    • /
    • v.17 no.4
    • /
    • pp.204-211
    • /
    • 2008
  • Polyethylene(PE) pipes have been widely used as they are easy to construct and suitable for economical efficient when they are compared with metal pipelines. This paper studied the effect of various external loadings on stress and deflection of the buried PE pipes using Finite Element Method(FEM). For this purpose, stresses of buried PE pipes were calculated according to the loading condition such as pipe types(pipe diameter $50{\sim}400mm$), burial depths($0.6{\sim}1.2m$) and internal pressures($0.4{\sim}4bar$). As a result, it was founded the effect and relation with each of loading conditions under the buried condition.