• Title/Summary/Keyword: 비례-적분 제어

Search Result 187, Processing Time 0.019 seconds

Cutting Torque Control in Drilling Part 1 : Design of a Cutting Torque Controller (드릴 공정시 절삭 토크 제어 제 1 편 : 절삭 토크 제어기의 설계)

  • O, Yeong-Tak;Gwon, Won-Tae;Ju, Jong-Nam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.8
    • /
    • pp.96-106
    • /
    • 2001
  • As the drilling depth increases, the cutting torque increases and fluctuates, which can lead to the machine tool vibration, severe tool wear, and catastrophic tool breakage. Hence, cutting torque control is very important to improve productivity in drilling. In this paper, a PID controller was designed to control the drilling torque. The plant including the feed drive system, cutting process and spindle drive system was modeled for controller design. The Ziegler-Nichols method was used to determine the controller gain and control action times and the root locus plot was used to tune the controller gain for a certain cutting condition. Also, suggested was a simple method to obtain the tuned controller gain for an arbitrary cutting condition not using the Ziegler-Nichols method and the root locus plot. The performance of the designed controller and the effect of controller gain tuning were verified from experiments.

  • PDF

Modulated Fuel Feedback Control of a Fuel Injection SI Engine (연료량 변조법에 의한 연료분사식 가솔린엔진의 공연비 제어)

  • 박경석;박진일;고상근;노승탁;이종화
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.102-111
    • /
    • 1996
  • For the air-fuel ratio control in a fuel injection SI engine, the Jump-Ramp control algorithm has been widely adopted by using the on/off type oxygen sensor. But the Jump-Ramp control method has limitation on treating the frequency and amplitude of the air-fuel ratio oscillation. This study suggests another feedback control logic named modulated fuel feedback control, which has a concept of pre-tuned air-fuel ratio oscillation. In the modulation method, the oxygen sensor output is not treated as on/off signal but as analog signal for feedback. By using the modulation method, the frequency and the amplitude of air-fuel ratio oscillation can be adjustable to some extent for improving the conversion efficiency of the Three-Way Catalyst. The result shows that the performance of the modulation method is better than that Jump-Ramp control method in reducing the amplitude of the air-fuel ratio oscillation as well as in increasing the frequency of the air-fuel ratio oscillation.

  • PDF

Electromagnetic Strip Stabilization Control in a Continuous Galvanizing Line using Mixture of Gaussian Model Tuned Fractional PID Controller (비정수 차수를 갖는 비례적분미분제어법과 가우시안 혼합모델을 이용한 연속아연도금라인에서의 전자기 제진제어 기술)

  • Koo, Bae-Young;Won, Sang-Chul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.8
    • /
    • pp.718-722
    • /
    • 2015
  • This paper proposes a fractional-order PID (Proportional-Integral-Derivative) control used electromagnetic strip stabilization controller in a continuous galvanizing line. Compared to a conventional PID controller, a fractional-order PID controller has integration-fractional-order and derivation-fractional-order as additional control parameters. Thanks to increased control parameters, more precise controller adjustment is available. In addition, accurate transfer function of a real system generally has a fractional-order form. Therefore, it is more adequate to use a fractional-order PID controller than a conventional PID controller for a real world system. Finite element models of a $1200{\times}2000{\times}0.8mm$ strip, which were extracted using a commercial software ANSYS were used as simulation plants, and Gaussian mixture models were used to find optimized control parameters that can reduce the strip vibrations to the lowest amplitude. Simulation results show that a fractional-order PID controller significantly reduces strip vibration and transient response time than a conventional PID controller.

Development of Compact Phase-difference Controller for an Ultrasonic Rotary Motor (회전형 초음파모터의 소형 위상차 제어기 개발)

  • Yi Dong-Chang;Lee Myoung-Hoon;Lee Eu-Hark;Lee Sun-Pyo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.8 s.185
    • /
    • pp.64-71
    • /
    • 2006
  • In this paper, a uniform speed controller for an ultrasonic rotary motor is developed using the phase-difference method. The phase difference method uses traveling waves to drive the ultrasonic motor. The traveling waves are obtained by adding two standing waves that have a different phase to each other. A compact phase-difference driver system is designed and integrated by combining VCO(Voltage Controlled Oscillator) and phase shifter. Theoretically the relationship between the phase difference in time and the rotational speed of the ultrasonic motor is sine function, which is verified by experiments. Then a series of experiments under various loading conditions are conducted to characterize the motor's performance that is the relationship between the speed and torque. Proportional-integral control is adopted for the uniform speed control. The proportional control unit calculates the compensating phase-difference using the rotating speed which is measured by an encoder and fed back. Integral control is used to eliminate steady-state errors. Differential control for reducing overshoot is not used since the response of ultrasonic motor is prompt due to its low inertia and friction-driving characteristics. The developed controller demonstrates reasonable performance overcoming disturbing torque and the changes in material properties due to continuous usage.

Control of Refrigerating Compressor Capacity Using Inverter (인버터를 이용한 냉동용 압축기의 용량 제어)

  • Yang, H.S.;Kim, H.S.;Kim, J.H.;Kim, S.B.;Kim, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.2
    • /
    • pp.94-101
    • /
    • 1993
  • Recently, efforts of decreasing energy consumption are continously increased and user's preference is also diversified in refrigeration and air conditioning systems. Thus, in order to satisfy these demands, high efficiency, high intelligence, and energy saving for those systems are essential. As the basic study for diverse functions and intelligence of those systems, we investigated the response characteristics through the compressor capacity control concerned with superheat and refrigeration room temperature. And, response characteristics are investigated experimentally by using micro computer based PWM inverter control method. Experimental result of the conventional on-off control method is given in order to be compared to the results of inverter control method. The results obtained through this study are summarized as follows. It is shown from the experimental results of the on-off control method that the range of temperature variation around the steady state ($-18^{\circ}C$) is very large (about $7{\sim}8^{\circ}C$) and the settling time bringing the steady state is not found. In the inverter control method, we can see that the refrigeration room temperature after reaching the setting temperature is very stable without fluctuation and a robust control for disturbance such as opening the door has been realized.

  • PDF

Design of Temperature based Gain Scheduled Controller for Wide Temperature Variation (게인 스케줄링을 이용한 광대역 온도제어기의 설계)

  • Jeong, Jae Hyeon;Kim, Jung Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.8
    • /
    • pp.831-838
    • /
    • 2013
  • This paper focused on the design of an efficient temperature controller for a plant with a wide range of operating temperatures. The greater the temperature difference a plant has, the larger the nonlinearity it is exposed to in terms of heat transfer. For this reason, we divided the temperature range into five sections, and each was modeled using ARMAX(auto regressive moving average exogenous). The movement of the dominant poles of the sliced system was analyzed and, based on the variation in the system parameters with temperature, optimal control parameters were obtained through simulation and experiments. From the configurations for each section of the temperature range, a temperature-based gain-scheduled controller (TBGSC) was designed for parameter variation of the plant. Experiments showed that the TBGSC resulted in improved performance compared with an existing proportional integral derivative (PID) controller.

가변 풍량 유닛에 의한 실내 공간의 온도제어를 위한 공간의 분할 모델과 상태궤환 제어기의 개발에 관한 연구

  • 박세화;신승철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.947-959
    • /
    • 2001
  • We propose a control scheme to control the indoor zone temperature via variable air volume (VAV) unit. To control the room temperature, state space model of the conditioned zone which is partitioned into nine artificial sectional regions is derived. The nonlinearity of the damper motion and actuator are considered for the practical use in the state space system description. The temperature control of the room temperature is performed by manipulating the degree of openness of the damper in relation to the local room temperature and the supplied air flow rate. In general, since a local temperature in the conditioned zone is measured, it is required to estimate the temperature values in each regions for the precise temperature control. We thus design a state observer to estimate the regional temperature, and use these values in the controller. The overall control system consists of the state observer based state feedback with the integral control. We compared the control results of the proposed scheme with those of cascade proportional and integral (PI) control, and showed that the scheme achieved precise control of the conditioned system.

  • PDF

An Adaptive Speed Control of a Diesel Engine by Means of the On-line Parameter Estimate (디젤기관의 on-line 파라미터 추정에 의한 적응 속도제어)

  • 유희한;하주식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.20-26
    • /
    • 1996
  • Recently, for the speed control of a diesel engine, some methods using the modern control theory such as LQ control technique, or $\textit{H}_{\infty}$control theory etc., have been reported. However, most of speed controlers of a diesel engine ever developed are still using the PID control algorithm. And, as another approach to the speed control of a diesel engine, the authors proposed already a new method to adjust the parameters of the PID controller by a model matching method. In the previous paper, the authors confirmed that the proposed new method is superior to Ziegler & Nichols's method through the analysis of results of the digital simulations under the assumption that the parameters of a diesel engine are known exactly. But, actually, it is very difficult to find out the value of parameters of a diesel engine accurately. And the parameters of a diesel engine are changigng according to the operating condition of a diesel engine. So, in this paper, a method to estimate the parameters of the PID controller for the speed control of a diesel engine by means of the model matching method are proposed. Also, the digital simulations are carried out in cases either with or without measurement noise. And this paper confirms that the proposed method here is superior to Ziegler & Nichols's method through the analysis of the characteristics of indicial responses.

  • PDF

A Study on DC-DC Power Supply for Magnetically Levitated Vehicle (자기부상열차용 DC-DC 전원장치에 관한 연구)

  • Chun, Choon-Byeon;Jeon, Kee-Young;Lee, Hoon-Goo;Han, Kyung-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.128-135
    • /
    • 2004
  • The author present a modified multi-loop algorithm including feedforward for controlling a 55kW step down chopper in the power supply of Maglev. The control law for the duty cycle consists of three terms. The first is the feedforward term. which compensates for variations in the input voltaga. The second term consists of the difference between the slowly moving inductor current and output current. The third term consists of proportional and integral terms involving the perturbation in the output voltage. This perturvation is derived by subtracting the desired output voltage from the actual output voltage. The proportional and integral action stabilizes the system and minimizes output voltage error. In order to verify the validity of the proposed multi-loop controller, simulation study was tried using Matlab simulink

Nonlinear Pitch and Torque Controller Design for Wind Turbine Generator Using Lyapunov Function (리아프노프 함수를 이용한 풍력 발전기 비선형 피치 및 토크 제어기 설계)

  • Kim, Guk-Sun;No, Tae-Soo;Jeon, Gyeong-Eon;Kim, Ji-Yon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.10
    • /
    • pp.1147-1154
    • /
    • 2012
  • In this study, a method for designing blade pitch and generator torque controllers for a wind turbine generator is presented. This method consists of two steps. First, the Lyapunov stability theory is used to obtain nonlinear control laws that can regulate the rotor speed and the power output at all operating ranges. The blade pitch controller is chosen such that it always decreases a positive definite function that represents the error in rotor speed control. Similarly, the generator torque controller always decreases a positive definite function that reflects the error in power output control. Then, the simulation-based optimization technique is used to tune the design parameters. The controller design procedure and simulation results are presented using the widely adopted two-mass model of the wind turbine.