• Title/Summary/Keyword: 비등효과

Search Result 133, Processing Time 0.026 seconds

Radiative Heat Transfer in Discretely Heated Irregular Geometry with an Absorbing, Emitting, and An-isotropically Scattering Medium Using Combined Monte-Carlo and Finite Volume Method (몬테카를로/유한체적결합법에 의한 국소 가열되는 복잡한 형상에서의 흡수, 방사, 비등방산란 매질에 대한 복사열전달 해석)

  • Byun, Do-Young;Lee, Chang-Jin;Chang, Seon-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.5
    • /
    • pp.580-586
    • /
    • 2004
  • The ray effects of finite volume method (FVM) or discrete ordinate method (DOM) are known to show a non-physical oscillation in solution of radiative heat transfer on a boundary. This wiggling behavior is caused by the finite discretization of the continuous control angle. This article proposes a combined procedure of the Monte-Carlo and finite-volume method (CMCFVM) for solving radiative heat transfer in absorbing, emitting, and an-isotropically scattering medium with an isolated boundary heat source. To tackle the problem, which is especially pronounced in a medium with an isolated heat source, the CMCFVM is suggested here and successfully applied to a two-dimensional circular geometry.

Studies on Preparation of $TiO_2$Powder with Purity and Fine Particle -A Study of High Purifying(I)- (고순도.미립 $TiO_2$분말 제조에 관한 연구 -고순도화 연구(I)-)

  • Lee, Mi-Jai;Jee, Mi-Jung;Kim, Hwan;Lee, Chul-Tae;Choi, Byung-Hyun
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.10
    • /
    • pp.933-937
    • /
    • 2000
  • 고기능성 전자재료용 TiO$_2$분말 및 박막제조에 사용되는 중간생성물인 TiCl$_4$는 99% 이상의 고순도가 요구된다. 고순도.미립의 TiO$_2$분말 및 TiCl$_4$는 황산법으로 제조한 저순도 TiO$_2$원료를 사용하여 염소화법으로 Ti-염화물 및 염화불순물로 제조한 후, 대부분의 염화불순물들은 3단계 과정을 거쳐 고순화 하였다. 대부분의 염화불순물은 분리.응축 및 분별증류로, VOCl$_3$는 mineral oil을 첨가하여 비등점을 변화시켜, 그리고 미량의 염화불순물은 열가수분해하여 침전시킨 후 유기용제 처리하여 제거하였다. 유기용제 처리는 TiO$_2$분말의 고순도화에 도움이 되었으며, 입자간의 응집을 적게 하여 TiO$_2$입자크기도 작아졌다. 또한 anatase에서 rutile 결정구조로의 전이온도도 낮아지는 부수적인 효과를 보였다.

  • PDF

A Study on the Improement of Condensation and Boiling Heat Transfer on Horizontal Tube by Fin Effect(ll)-Shellside Condensation- (수평 원형전열관의 핀효과에 의한 응축 및 비등 열전달촉진에 관한 연구 (2)-튜브외부 응축-)

  • 한규일;조동현
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.5
    • /
    • pp.1275-1287
    • /
    • 1994
  • Heat transfer performance improvement by fin and grooves is studied for condensation of R-11 on integral-fin tubes. Eight tubes with trapezoidal shaped integral-fins having fin densities from 748 to 1654 fpm and 10, 30 grooves are tested. A plain tube having the same diameter as the finned tubes is also tested for comparison. R-11 condenses at saturation state of $32^{\circ}C$ on the outside tube surface cooled by inside water flow. All of test data ate taken at steady state. Beatty and Katz's, Rudy's and Webb's theoretical models are used to predict the R-11 condensation coefficient of tubes having 748, 1024 and 1299 fpm. The predicted value by Betty and Katz's model is within 10% of experimental values in this study at fpm<1024 and Rudy's model predicted the experimental data at fpm>1024 within 15%. The tube having fin density of 1299 fpm and 30 grooves has the best overall heat transfer performance. This tube shows the overall heat transfer coefficient of 11500 $W/m^{2}K$,/TEX> at coolant velocity of 3.0m/s.

Study of Pool Boiling Heat Transfer on Various Surfaces with Variation of Flow Velocity (다양한 표면에서 유동 속도에 따른 풀 비등 열전달에 관한 연구)

  • Kang, Dong-Gyu;Lee, Yohan;Seo, Hoon;Jung, Dongsoo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.343-352
    • /
    • 2013
  • In this study, a smooth flat surface, low fin, Turbo-B, and Thermoexcel-E surfaces are used to examine the effect of the flow velocity on the pool boiling heat transfer coefficients (HTCs) and critical heat fluxes (CHFs). HTCs and CHFs are measured on a smooth square heater of $9.53{\times}9.53mm^2$ at $60^{\circ}C$ in a pool of pure water at various fluid velocities of 0, 0.1, 0.15, and 0.2 m/s. Test results show that for all surfaces, CHFs obtained with flow are higher than those obtained without flow. CHFs of the low fin surface are higher than those of the Turbo-B and Thermoexcel-E surfaces due largely to the increase in surface area and sufficient fin spaces for the easy removal of bubbles. CHFs of the low fin surface show even 5 times higher CHFs as compared to the plain surface. On the other hand, both Turbo-B and Thermoexcel-E surfaces do not show satisfactory results because their pore sizes are too small and water bubbles easily cover them. At low heat fluxes of less than $50kW/m^2$, HTCs increase as the flow velocity increases for all surfaces. In conclusion, a low fin geometry is good for application to steam generators in nuclear power plants.

Fundamental Study on a Distillation Separation of a LiCl-KCl Eutectic Salt from Rare Earth Precipitates (희토류 침전물로부터 LiCl-KCl 공융염의 증류 분리에 관한 기초연구)

  • Yang, Hee-Chul;Eun, Hee-Chul;Kim, In-Tae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.1
    • /
    • pp.65-70
    • /
    • 2010
  • The distillation rate on LiCl-KCl eutectic salt under different vacuums from 0.5-50 mmHg was first investigated by using both a non-isothermal and a isothermal thermogravimetric (TG) analysis. Based on the non-isothermal TG data, distillation rate equations as a function of the temperature could be derived. Calculated flux by these model flux equations was in agreement with the distillation rate obtained from isothermal TG analysis. A distillation rate of $10^{-4}-10^{-5}$ mole $cm^{-2}sec^{-1}$ is obtainable at temperatures less than 1300K and vacuums of 0.5-50 mmHg. About a 99% salt distillation efficiency was obtained after an hour at a temperature above 1150 K under 50 mmHg in a small scale distillation test system. An increase in the vaporizing surface area is relatively effective for removing residual salt in the remaining particles, when compared to that for the vaporizing time. Over 99.95% of total distillation efficiency was obtained for a 1-h distillation operation by increasing the inner surface area from $4.52cm^2$ to $12.56cm^2$.

Screening of Fungicies for the Control of Postharvest Fruit Rots of Kiwifruit (참다래 저장병 방제 약제 선발)

  • Koh, Young-Jin;Lee, Jae-Goon;Hur, Jae-Seoun;Park, Dong-Man;Jung, Jae-Sung;Yu, Yong-Man
    • Research in Plant Disease
    • /
    • v.9 no.3
    • /
    • pp.170-173
    • /
    • 2003
  • For the effective chemical control to minimize infection of storage pathogens on kiwifruit in the field, this study was conducted to screen alternative fungicides which could be substituted for the fungicides Benomyl WP and Thiophanate-methyl 제 registered for the control of postharvest fruit rats of kiwifruit in Korea. Among the 8 fungicides tested, Tebuconazole WP, Iprodione WP and Flusilazole WP showed higher inhibitory effects on themycelial growths of 3 major pathogens of postharvest fruit rots, Botryosphaeria dothidea, Diaporthe actinidiae and Botrytis cinerea on potato dextrose agar. They also showed control efficiencies as high as those of Benomyl WP and Thiophanate-methyl WP on postharvest fruit rots in the field. They might be good candidates for fungicieds for the control of postharvest fruit rots of kiwifruit.

Simulation of plate deformation due to line heating considering water cooling effects (수냉 효과를 고려한 선상가열에 의한 판 변형의 시뮬레이션)

  • Ko, Dae-Eun;Ha, Yun-Sok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2470-2476
    • /
    • 2011
  • Inherent strain method, a hybrid method of experimental and numerical, is known to be very efficient in predicting the plate deformation due to line heating. For the simulation of deformation using inherent strain method, it is important to determine the magnitude and the region of inherent strain properly. Because the phase of steel transforms differently depending on the actual speed of cooling following line heating, it should be also considered in determining the inherent strain. A heat transfer analysis method including the effects of impinging water jet, film boiling, and radiation is proposed to simulate the water cooling process widely used in shipyards. From the above simulation it is possible to obtain the actual speed of cooling and volume percentage of each phase in the inherent strain region of a line heated steel plate. Based on the material properties calculated from the volume percentage of each phase, it should be possible to predict the plate deformations due to line heating with better precision.

An Application of Algebraic Stress Model to a Two-Dimensional Buoyant Surface Jet (2차원 표층밀도분류에 대한 대수응력모델의 적용)

  • 김기흥;함계운;박준일;허재영
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.7 no.3
    • /
    • pp.248-256
    • /
    • 1995
  • The numerical study on the surface buoyant jets has remained of requiring more intensive investigation for problems due to the treatments of free surface, Reynolds stress/flux terms in turbulent flow and especially buoyancy effects on the turbulent fluctuation. etc. The verification of predicted results from the numerical study continues in the qualitative study. because of the lack of experimental data, which seems to be due to the difficulties in measuring the turbulent fluctuations in concentration or temperature fields. In this study, the computer program of Algebraic Stress Model has been developed to investigate the behaviours of two-dimensional surface buoyant jets with free surface boundary condition. The computational results are compared with published experimental data. By comparing these results with experimental data. it is found that this model can predict fairly well the flow characteristics of two-dimensional surface buoyant jets in the momentum-dominant region and buovancy-dominant region. Especially, it is proved that this model can predict the flow characteristics reasonably in buoyancy-dominant region stably stratified due to buoyancy effect.

  • PDF

Kinetics of Anhydride Curing of Epoxy : Effect of Chain Length of Anhydride (에폭시 무수화물 경화의 동력학적 연구: 무수화물의 사슬 길이 효과)

  • Chung, I.;Lee, J.
    • Elastomers and Composites
    • /
    • v.40 no.1
    • /
    • pp.3-11
    • /
    • 2005
  • The ruling kinetics of epoxy resins with 3 different kinds or alkenylsuccinic anhydride (ASA) having C-8, C-12, and C-16 pendant side chain length with two different catalysts was studied by using differential scanning calorimetry (DSC). Nonisothermal and isoconversional method has been used for characterizing the effect of the pendant side chain length in the curing process. Results or nonisothermal method showed that there was no significant difference in the effect of the pendant side chain length of ASA. But isoconversional analysis showed that the value of the activation energy for the initiation reaction or C-8, C-12, and C-16 were $61.7{\sim}57.7kJ/mol$, $63.0{\sim}57.3 kJ/mol$, and $130.4{\sim}94.2 kJ/mol$, respectively, depending on the catalyst used. The values of activation energy for the initiation is different as reported value of 20 kJ/mol which indicating the difference in the effect of the pendant side chain length of ASA in the initial stage of the reaction.

Interaction Effects between Glyphosate and Some Other Herbicides on Cutgrass, Leersia oryzoides SW (겨풀(Leersia oryzoides SW.)에 대한 Glyphosate와 수종(數種) 제초제간(除草劑間)의상호작용(相互作用) 효과(效果))

  • Yim, I.B.;Guh, J.O.;Lee, K.H.
    • Korean Journal of Weed Science
    • /
    • v.7 no.3
    • /
    • pp.329-336
    • /
    • 1987
  • Antagonistic interaction between glyphosate and some herbicides in effects of post-emergence application on cut grass and of pre-emergence application on some weed species including barnyardgrass was evaluated with pots in plastic house. By addition of oxyfluorfen to glyphosate, the weeding efficacy on cutgrass was visually evaluated as promotive in both weeding rate and efficacy. However, by alachlor, simazine, gluphosinate or quizalofop-ethyl showed delayed weeding rate, and by paraquat, the promotive in rate but lower in efficacy, respectively. Fresh weights of cutgrass at 30 days after the lower-rate application has generally indicated the lower weeding efficacy than that from glyphosate alone. Even at higher rate application, the addition of alachlor or simazine to glyphosate has still indicated the lower efficacies. As a result of interaction analysis by Colby method, no synergism was detected from any treatments, and the combinations of simazine or paraquat to glyphosate in lower mixing rate showed significant antagonism at 5% probability level of DMRT. On the annual weed species including barnyardgrass, the significant soil-residual weeding efficacies were recognized by addition of any rate of oxyfluorfen, alachlor, simazine and higher rate of quizalofop-ethyl to glyphosate, respectively.

  • PDF