• Title/Summary/Keyword: 비드형

Search Result 80, Processing Time 0.027 seconds

A Study on Design and Fabrication of Broad-Band EMC filter for PDP (PDP용 광대역 EMC 필터의 설계 및 제작에 관한 연구)

  • 김동일;구동우;양은정;김도연
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.5
    • /
    • pp.437-443
    • /
    • 2003
  • A interference of outside electric source and electric fast transient(EFT) are origins of destroy and malfunction in the precise electrical and electronic equipments. It makes a serious obstacle as the form of conducted noise. Therefore, it is strongly needed to protect precision electrical and electronic equipments from the interference and EFT. In this research, a EMC filter composed of feed-through capacitors and ferrite beads of high permeability is designed and it's properties are investigated for PDP. The filter produced in this research have wide band frequency characteristics and more than 40 dB reflection loss in the frequence of 10 MHz∼1.5 GHz which satisfy the standard of CISPR Pub. 22 and the level 4 of IEC 61000-4-4.

Evaluation on Drainage Capacity of Cylindrical Drain with Different Core Shapes (코아형식에 따른 원통형 배수재의 구멍막힘에 의한 배수능력 평가비교)

  • Lee Kwang-Yeol;Nugroho David Setiawan;Yun Sung-Tae;Ji Ho-Yeol
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.311-315
    • /
    • 2006
  • Various core shapes of cylindrical drains are used for accelerating primary consolidation for soft clay deposits, but serious harmful disadvantages on drainage capacity may occur on cylindrical drains due to confining Pressure when they are installed in that soil. In this study, two different core shapes of cylindrical drain are used to evaluate the drainage capacity with consideration of clogging effects on their filter jackets for an applied confining pressure. Column tests with radial drainage system were conducted under confining pressure of 50 kPa for 13 days. Two parameters which are discharge and accumulated volume of water drained were measured as the time elapsing. From this experimental study, the results showed that at the Initial stage before the clogging developed enough, the cylindrical drain with angular-type-plastic-core could produce discharge twice higher (maximum) than those with round-type. After 13 days had passed on, cylindrical drain with angular-type-plastic-core could produce discharge only 20% higher than those with round-type one. Eventually, there is a possibility that the efficiency of using angular-type-cylindrical-drain will be similar to the round-type one as the clogging develops more.

  • PDF

GMAW of 6K21-T4 Aluminum Alloy for Tailor Welded Blank(TWB) (TWB 적용을 위한 6천계열 알루미늄 합금의 GMA용접)

  • Kim, Yong;Yang, Hyun-Seok;Park, Ki-Young;Seo, Jong-Dock;Choi, Won-Ho
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.50-50
    • /
    • 2009
  • 본 연구에서는 차체 부품의 경량소재 대체에 따른 Panel Assembly Rear Seat Back 부품 제작에 최신 저입열 미그용접공정을 적용한 TWB(Tailor Welded Blank) 공정기술을 확보하기 위해 최적 용접조건 도출에 관한 연구를 진행하였다. 용접 후 성형이 이뤄지는 제조공정의 특성 상 성형강도에 중점을 둔 실험을 진행하였으며, 이를 위해 각 와이어에 따른 용접부의 기계/금속학적 특성이 평가되었다. 대상 시편은 6천계열 열처리형 합금이며, 두께는 각각 1.6t, 1.4t로 이를 맞대기 용접 후 그 특성을 평가하였다. 용접은 저입열 GMA용접 공법 중 하나인 CMT 용접법(Cold Metal Transfer)을 사용하였으며, 평가 대상 와이어로는 4043, 4047, 5183 및 5356이 사용되었다. 특성평가는 마크로 및 마이크로 조직, 경도, 인장강도, 기공 및 결함, 성형강도 등에 대해 이뤄졌으며, 희석된 와이어의 조성이 용접부 특성에 미치는 영향에 대해서도 검토되었다. 실험 결과, 5천계열 와이어가 성형강도에 비교적 더 강인한 결과를 나타냈으며 성형강도는 용접조건 및 초기 갭에 대한 영향은 받았으나, 비드형상과 강도간의 연관성은 찾을 수 없었다. 이에 따라 TWB 적용을 위한 와이어로는 5356이 가장 우수한 것으로 판명되었다.

  • PDF

Preparation and Dissolution Characteristics of Sustained Release Pellets Containing Isosorbide Dinitrate (질산 이소소르비드가 함유된 서방형 펠렛의 제조 및 용출 특성)

  • Lee, Gye-Won;Kim, Hak-Hyung;Ryu, Sung-Kyun
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.6
    • /
    • pp.381-385
    • /
    • 2008
  • Isosorbide dinitrate is an oral assiatant therapy agent of angina pectoris, myocardial infarction and congestive heart failure. The objective of this study was to formulate sustained release containing isosorbide dinitrate and assess their formulation variables. Pellets were prepared by fluid bed process and consist of drug layer and membrane layer. The pellets were coated with ethylcellulose along with $5{\sim}15%$ of plasticizer such as triacetin and diethyl butylrate. In vitro evaluation study was performed by comparative dissolution test between test and reference isosorbide dinitrate preparation. We could prepare sustained pellets of isosorbide dinitrate by fluid bed process which were reduced process time and had high content. The pellet coated with 1% ethylcellulose and triacetin(l5%) had a similar dissolution behavior compare to reference isosorbide dinitrate preparation controlling initial dissolution and those of dissolution at 30 min were 17.25 and 17.09%, respectively. Difference factor and similarity factor were $0{\sim}15$ and $50{\sim}100$ and there was no significant difference in bioequivalence between formulations. It might be concluded that our sustained release pellet of isosorbide dinitrate could be an alternatively delivery system to reference drug preparation.

Appling of Force Control of the Robotic Sweeping Machine for Grinding (연마작업을 위한 로봇형 연마기의 힘제어 적용)

  • Jin, Taeseok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.2
    • /
    • pp.276-281
    • /
    • 2014
  • In this research, we describe a force feedback control for industrial robots has been proposed as a system which is suitable to work utilizing pressure sensitive alternative to human. Conventionally, polished surface of the workpiece are recognized, chamfer ridge, machining processes such as deburring, and it is most difficult to automate because of its complexity, has been largely dependent on the human. To aim to build automatic vacuum system robotic force control was gripping the grinding tool, the present study we examined the adaptability to the polishing process to understand the characteristics of the control system feedback signal obtained from the force sensor mainly. Furthermore, as a field, which holds the key to the commercialization, I went ahead with the application to robotic sweeping machine. As a result, the final sweeping utilizing a robot machine to obtain a very good grinded surface was revealed.

Audio-based COVID-19 diagnosis using separable transformer (트랜스포머를 이용한 음성기반 코비드19 진단)

  • Seungtae Kang;Gil-Jin Jang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.3
    • /
    • pp.221-225
    • /
    • 2023
  • In this paper, we proposed an efficient method for rapid diagnosis of COVID-19 by voice. A novel Strided Convolution Separable Transformer (SC-SepTr) is proposed by modifying the conventional Separable Transformer (SepTr) for audio signal recognition. The proposed method reduces the memory and computational requirements to enable rapid diagnosis of COVID-19. As a result of experiments on Coswara, it was shown that the proposed method perform rapid diagnosis with guaranteeing Area Under the Curve (AUC) performance even for a relatively small amount of learning data.

Investigation of Draw-bead Free Die Design to Prevent Wrinkles for Stainless Steel Basket-bowl Production (무비드 성형 조건에서 스테인리스 강 Basket-bowl의 주름 방지를 위한 금형 설계 연구)

  • S. Lee;C. H. Jeon;S. Park;G. Lee;S. Choi;W. Lee;D. Kim
    • Transactions of Materials Processing
    • /
    • v.32 no.4
    • /
    • pp.199-207
    • /
    • 2023
  • The stainless steel basket-bowl, a critical component of washing machines, is characterized by its unique two-tiered circular shape. This study explores the potential of a draw-bead free die design to address tearing concerns in the prospective plastic layer during the drawing operation. In order to prevent wrinkles that may arise from the absence of a draw-bead, a two-stage punch configuration is proposed. The influence of the blank holder force on wrinkle reduction is also examined. Finite element analysis is employed to evaluate the proposed die design by analyzing the wrinkle shape and strain mode. The results confirm that the stainless steel basket-bowl can be successfully drawn without wrinkles utilizing the proposed two-stage punch without a draw-bead on the blank holder. These findings contribute to the development of more efficient and reliable manufacturing processes for the stainless steel basket-bowl production.

Manufacture of Immobilization Device (Vac-lok) and the Usefulness of Evaluation for Reproducibility of Patients in the Radiotherapy (환자의 재현성을 위한 고정장치(Vac-lok) 제작과 방사선치료에서 유용성 평가)

  • Lee, Jae-Seung;Kim, Gyoung-Hee;Jeong, Kyu-Hwan;Kweon, Dae-Cheol;Goo, Eun-Hoe;Park, Cheol-Woo;Im, In-Chul;Dong, Kyung-Rae;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.1
    • /
    • pp.8-16
    • /
    • 2011
  • We manufactured the Vac-lok that can be applied to patient of special body shape and need to special set-up position and evaluated the usefulness in the radiation therapy. The manufacture Vac-lok, It was used EVA resin and biobeadform of a diameter 1.5 mm. carried out the test of functionality, structural and analyzed the relative reproducibility of phantoms and patients. During the total period of radiation therapy, Vacuum pressure bring variety to a very small amount in the test of functionality of the manufacture Vac-lok. But It was a negligible quantity. The manufacture Vac-lok improved the relative reproducibility of phantoms than the existing Vac-lok and tolerance has a confidence less than 4% error. Also, relative reproducibility of patient increased error than phantom in the antero-posterior and lateral plan. However, the maximum set-up error was less than ${\pm}\;2.3$ mm. In conclusion, If tolerance set-up error of radiotherapy is less than ${\pm}\;3$ mm, the manufacture Vac-lok was enough possible to use and improvement of reproducibility, considering supply with the Vac-lok made to measure of special patient that produced at a low price and without delay.

Optimal Mixtures of Roadway Pavement Marking Beads Under Various Weather Conditions (기상조건 변화에 따른 노면표시 비드의 최적 배합비율 산정)

  • Lee, Seung-Kyu;Lee, Seung-Hyun;Choi, Kee-Choo
    • International Journal of Highway Engineering
    • /
    • v.14 no.3
    • /
    • pp.131-140
    • /
    • 2012
  • Lane markings such as edgelines, centerlines, and lines that delineate lanes generally provide drivers with the various information for safe driving. Drivers can easily recognize the lane markings through the color differences between the markings and road surfaces during the daytime. However, it is a bit difficult for drivers to perceive them during the nighttime due to the lack of artificial lights. Although the glass beads with the 1.5-refractive index have been used to improve the visibility of the lane markings during the nighttime, it is still difficult for drivers to recognize the lane markings properly, especially during the rainy nighttime, which may often lead to traffic accidents. To improve the retroreflectivity and visibility of the lane markings during the rainy nighttime, the high refractive beads with the 2.4-refractive index are essentially required, but they do not work appropriately during the dry nighttime. Thus, the mixed materials with the 1.5, 1.9, and 2.4-refractive beads should be considered for the satisfactory implementation of the lane markings. This study reveals the best mixing rates of the beads by conducting benefit-cost analysis under various weather conditions in Korea. The analysis results show that the lane markings with the 100% of the 2.4-refractive beads provide the highest visibility of lane markings regardless of the roadway conditions, but the benefit-cost (B/C) ratio of the bead mixture is merely 0.46. The best mixing rate of the beads, from the highest B/C ratio viewpoint, was identified as the mixture with a 80% of 1.5-refractive beads and a 20% of 2.4-refractive beads. Some limitations and future research agenda have also been discussed.

Distribution of Magnetic Field Depending on the Current in the μ-turn Coil to Capture Red Blood Cells (적혈구 포획용 미크론 크기 코일에 흐르는 전류의 크기에 따른 자기장 분포 특성)

  • Lee, Won-Hyung;Chung, Hyun-Jun;Kim, Nu-Ri;Park, Ji-Soo;Lee, Sang-Suk;Rhee, Jang-Roh
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.5
    • /
    • pp.162-168
    • /
    • 2015
  • The ${\mu}$-turn coil having a width of ${\mu}m$ on the GMR-SV (giant magnetoresistance-spin valve) device based on the antiferromagnetic IrMn layer was fabricated by using the optical lithography process. In the case of GMR-SV film and GMR-SV device, the magnetoresistance ratios and the magnetic sensitivities are 4.4%, 2.0%/Oe and 1.6 %, 0.1%/Oe, respectively. In the y-z plane the distribution of magnetic field of GMR-SV device and $10{\mu}$-turns coil which put under the several magnetic bead(MB)s with a diameter of $1{\mu}m$ attached to RBC (red blood cell) was analyzed by the computer simulation using the finite element method. When the AC currents of 20 kHz from 0.1 mA to 10.0 mA flow to the 10 turns ${\mu}$-coil, the magnetic field at the position of $z=0{\mu}m$ at the center of coil was calculated from $30.1{\mu}T$ to $3060{\mu}T$ in proportion to the current. The magnetic field at the position of $z=10{\mu}m$ was decreased to one-sixth of that of $z=0{\mu}m$. It was confirmed that the $10{\mu}$-turn coil having enough magnitude of magnetic field for the capture of RBC is possible to use as a biosensor for the detection of magnetic beads attached to RBC.