• Title/Summary/Keyword: 비눗물

Search Result 6, Processing Time 0.017 seconds

A Fundamental Study on the Contaminants Using in Place of the Soapy Water for Floor Slip Resistance Test (바닥의 미끄럼시험에 사용되는 비눗물 대체 물질에 관한 기초적 연구)

  • Kim, Dae-Kyu;Shin, Yun-Ho;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.156-157
    • /
    • 2015
  • The safety concern of slipping on floors in South Korea has come to the fore as a social problem, but the occurrence of such accidents has not decreased. Slip and fall accidents have several causes, but they are especially common when there is soapy water on the floor during a shower or a bath. Despite this situation, it can be said that there is a lack of standards on surface contamination materials used in floor slip resistance testing. Therefore, in this study, we conducted a survey to identify the components and quantity of soapy water that actually results from a user taking a shower, and the standardization of contamination materials. Based on the results of this experiment, we provide a surface contamination material that can replace the soapy water used in floor slip resistance testing.

  • PDF

방사성 피부오염의 제염법에 관한 연구 (I)

  • 전제근;지평국;안병길;박종묵
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.113-117
    • /
    • 1996
  • 원자력시설 및 동위원소 이용기관에서의 인체오염사고에 대비하여, 피부제염기준을 조사하였으며, 피부제염제의 개발을 위하여 실험용 쥐를 대상으로 Co-60 및 Cs-137에 대해 비눗물, EDTA 및 KAERI-CON의 제염효과를 비교하였으며, 가장 효율적인 제염방법을 제시하였다. 각 제염제의 제염실험결과 Co-60 보다 Cs-137에 대한 제염이 더 잘 이루어졌으며, 제염횟수의 증가에 따라 방사능잔류율도 급격히 낮아졌다. KAERI-CON은 Co-60의 경우 38-55%, Cs-137의 경우에는 44-50%까지 제염효율을 보임으로서 타 제염제보다 효과적임을 확인하였다.

  • PDF

Extraction of Proper Mixture Ratio of SDS Solution as the Substitute of Soapy Water in a Slip Test (미끄럼시험에서 비눗물을 대체하기 위한 SDS 수용액의 적정 혼합비율 도출)

  • Kim, Dae-Kyu;Shin, Yun-Ho;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.83-84
    • /
    • 2016
  • For the slip resistance test of shower room floor, the "O-Y Pull Slip Meter method (O-Y·PSM)" regulated under KS M 3510. This test method uses cooking oil as a substitute of soapy water, and thus it does not reflect the real condition. In this study, on 10 types of floor material samples, the Coefficient of Slip Resistance Bath (CSR·B) on bare foot between 10 types of body wash solution and 6 types of SDS solution was compared. The body wash solution is a mixture of soap and water in 1:20 ratio. As a result, SDS 0.1% solution was the most suitable for a substitute of soapy water in shower.

  • PDF

The Effect of Hair Spray on the Fitting of Contact Lenses (헤어스프레이가 콘택트렌즈의 피팅에 미치는 영향)

  • Chung, Jin Young;Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • Various kinds of aerosols such as a mixture of hairspray resin and its solvents, a perfume, a soap water, and ask in-lotion were sprayed onto the contact lens which was mounted on the eye-model made of wood, varying the parameters as the distance between nozzle and contact lens and the spraying time duration. In the case of both the hairspray and the perfume including an ethanol as solvents, the shape of contact lenses has changed tremendously Jess than 1 minute after the exposure to the aerosol particles and then it continued until the lens surfaces were completely flipped over. Driving force for the lens distortion seems to be the expansion coefficient difference between the inner and outer surface of lens, which was caused by the heat of vaporization of ethanol included in the aerosol and subsequent temperature decrease induced on the lens surface.

  • PDF

Clinical study on the maxillofacial prosthodontic treatment using dental implant: Part I-Color stability of maxillofacial elastomeric materials (치과용 임플란트를 이용한 악안면 보철치료에 관한 임상적 연구 1부-악안면보철용 실리콘의 색안정성)

  • Jin, Tai-Ho;Bowley, John F.
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.379-388
    • /
    • 1998
  • 본 연구는 악안면보철용 실리콘의 색안정성을 연구하기 위하여 실리콘 재료로 MDX 4-4210 Silicone(Dow Coming. Midland, Mich.)과 A-2186(Factor II, Lakeside, Az)을 사용하고 Mars Violet. Golden Yellow, Red yellow, Raw Sienna등 4종의 색소(Factor II, Lakeside, Az)를 이용하여 시편을 제작한 후 1군은 섭씨5-55도에서 700회 thermocycling하였고, 2군은 10%의 비눗물(Ivory, Proctor & Gamble Inc,. Toronto, Ontario)에 담아 섭씨15-55도에서 700회 thermocycling하였다. 3군은 10%의 비눗물에 담아 75일간 실온에서 보관하였으며 4군은 실온의 암실에 75일간 보관하였다. 5군은 초여름인 6월 중순부터 75일간 햇볕이 잘드는 곳에 위치하였다. 이를 측색색차계(Model TC-6FX, Tokyo Denshoku Co., Japan)를 이용하여 측정하고 색변화를 연구한 결과 다음과 같은 결론을 얻었다. 1. $L^*$값의 경우 모든 실험군에서 대조군에 비해 유의하게 감소하였다. 2. $a^*$값의 경우 대부분의 실험군에서 증가하였으나 Raw sienna, Mars violet색소를 사용한 실험 3.4.5군의 MDX4-4210의 경우 감소하는 경향을 보였다. 3. $b^*$값은 실험1.2.3군의 경우 대부분 감소하였고 실험4.5.군의 경우에서 증가하였으나 3.4.5군의 경우에서 대부분 유의한 차이가 없었다. 4. ${\Delta}E$의 값은 실험군에서 대부분 감소하였으나 4군의 A-2186에서 증가하는 경향을 보였고 실험2군의 Red yellow, Mars violet을 사용한 MDX4-4210에서 비교적 큰 변화를 보였다. 5. $L^{\ast}$값과 a값의 변화량의 합은 A-2186의 경우에서 크게 나타났으나 ${\Delta}E$값의 변화량은 MDX4-4210에서 크게 나타났다. 6. $L^*$값의 변화량의 합은 실험4군에서 크게 나타났으며 $a^*$값은 1군에서, $b^*$값과 ${\Delta}E$값의 변화량의 합은 2군에서 크게 나타났다.

  • PDF

Study on the Effectiveness of some Decontamination Agents against Skin Contamination of $^{137}Cs$ and $^{60}Co$ (제염제의 $^{137}Cs$$^{60}Co$에 의한 피부오염의 제염효과에 관한 연구)

  • Chon, Je-Keun;Ji, Pyung-Kook;Kwak, Sang-Soo;Kim, Byung-Tae;Park, Chong-Mook
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.1
    • /
    • pp.7-15
    • /
    • 1998
  • In order to evaluate the effectiveness of some decontamination agents against skin contamination of $^{60}Co$ and $^{137}Cs$, the experiments were carried out in this study. In the experiments, pig skin was used instead of human skin , $^{60}CoC1_2$ and $^{137}CsCl$ were used the liquid sources of skin contamination. To examine the effectiveness of decontamination agents, skin decontamination was tried using soup, EDTA, KAERICON which was developed for decontamination of radionulides on the surface of building structure, and new decontamination agents such as IOCON, TRICON, and CHARCON, which were developed in this study. The absorption of radionuclides through the skin was evaluated by the gamma-tay detection on the surface of sample skin after radionuclides were penetrated into the skin during 16 hour soiling time. The results of this absorption experiment indicated that 11.5% and 3.2% of initial amounts of $^{137}Cs$ and $^{60}Co$, respectively, were panerated into the skin. In the experiment to remove the residual radioactivity fixed on the skin, KAERICON showed the decontamination rates up to 52.1%(decontamination factor of 2.1) and IOCON showed the equivalent decontamination rate (decontamination factor 1.9) for $^{137}Cs$. However, IOCON and CHARCON showed the poor decontamination rates of less than 20%(decontamination factor of 1.2) for $^{60}Co$, and KAERICON showed the poor decontamination rate (decontamination factor 1.1) for $^{60}Co$. For TRICON, the decontamination factors were 1.6 to 1.8 for $^{137}Cs$, and 1.0 to 1.2 for $^{60}Co$, respectively.

  • PDF