• Title/Summary/Keyword: 비균일

Search Result 2,054, Processing Time 0.032 seconds

Optimum Release of Uniform Testing Software (테스트노력이 균일한 소프트웨어의 최적발행)

  • 최규식;김종기
    • Proceedings of the Korea Inteligent Information System Society Conference
    • /
    • 2002.05a
    • /
    • pp.423-428
    • /
    • 2002
  • 소프트웨어를 개발 및 발행함에 있어서 테스트와 디버깅 작업을 얼마나 오랫동안 수행하여 발행하느냐에 따라 운영중에 발생되는 결함 및 수정비용이 달라지므로 이 시기를 결정하는 것이 매우 중요하다. 테스트노력이 균일할 수도 비균일할 수도 있으나, 일반적으로 테스트노력은 일정한 것으로 가정하므로 본 논문에서도 일정테스트인 경우에 대해서 고찰한다

  • PDF

Studies of Raw Silk Size Nonuniformity. (생사비균일섬도발생 원인에 관한 연구)

  • 최병희
    • Journal of Sericultural and Entomological Science
    • /
    • v.7
    • /
    • pp.65-74
    • /
    • 1967
  • This work has been carried out to find the fundamental reasons of raw silk size nonuniformity by studying with the physical nature and its bave formation through the worm spinnerate with anatomical device. Mean time, the uniformity improving method is also attached to this paper after throughfall theoretical study. 1. According to the anatomical study of the silkworm spinnerate, the physical form decides the fiber cross section and also spinns more finner size as the spinning is continued collaborating with the muscle pressure and decrease of liquid silk in the silk gland. 2. The bave size deviation of the Korean cocoons have shown a little difference among the varieties, but, they are conclued as 0.58 denier in average which caused some size deviation of the raw silk inevitably. 3. The raw silk nonuniformity increases when the cocoon have size is not suitable with the proposed raw silk size. 4. The nonuniformity is also increased very much during the filature process in case of poor technical work, but even if we do our best, the best result is found as 30 percent improvement which is still worser than the natural cocoon size deviation. 5. It is required to be careful for the selection of silkworm variety in order to improve the nonuniformity of raw silk so that the bave size be suitable for the proposed silk. 6. The definite size silk reeling method could made better uniform silk, 20 percent at least, than the definite cocoon number silk reeling method. 7. A newly developed denier(21d) gauge was applied for the multiends type silk reeling machine which is widely used in Korea, and the result of the method showed 1.30 denier size deviation, but, in case of no use of it was 1.57 denier size deviation, that is, it could improve two grades more than the normal reeling method.

  • PDF

A New Speech Waveform Coding Based on the Nonuniform Sampling Method with Separated to High-Low Band (대역분리-비균일표본화 방법을 이용한 새로운 음성신호의 파형부호화 연구)

  • Bae, Myung-Jin;Lee, Joo-Hun;Im, Sung-Bin;Lee, Won-Cheol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.5
    • /
    • pp.89-93
    • /
    • 1995
  • To reduce the redundancy within samples that resulted from uniform sampling method, nonuniform sampling or nonredundant-sample coding methods can be considered. However, it is well known that when conventional nonuniform sampling methods are applied directly to speech signal, the required amount of data is comparable to or mure than that by uniform sampling method like PCM. To overcome this problem, a new nonuniform sampling method is proposed, in which nonuniform sampling is applied to the low-pass filtered speech signal and higher band is compensated by 8 colored Gaussian random noise with various noise levels. By this method, speech signal waveform can be encoded by 1.8 times larger compression ratio than the conventional nonuniform sampling method.

  • PDF

The Heterogeneity of Flow Distribution and Partition Coefficient in [15O-H2O] Myocardium Positron Emission Tomography ([15O-H2O] 심근 양전자 단층 촬영에서 혈류 분포의 비균일성과 분배계수)

  • Ahn, Ji Young;Lee, Dong Soo;Kim, Kyung Min;Jeong, Jae Min;Chung, June-Key;Shin, Seung-Ae;Lee, Myung Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.32-49
    • /
    • 1998
  • For estimation of regional myocardial blood flow with O-15 water PET, a few modifications considering partial volume effect based on single compartment model have been proposed. In this study, we attempted to quantify the degree of heterogeneity and to show the effect of tissue flow heterogeneity on partition coefficient(${\lambda}$) and to find the relation between perfusable tissue index(PTI) and ${\lambda}$ by computer simulation using two modified models. We simulated tissue curves for the regions with homogeneous and heterogeneous blood flow over a various flow range(0.2-4.0ml/g/min). Simulated heterogeneous tissue composed of 4 subregions of the same or different size of block which have different homogeneous flow and different degree of slope of distribution of blood flow. We measured the index representing heterogeneity of distribution of blood flow for each heterogeneous tissue by the constitution heterogeneity(CH). For model I, we assumed that tissue recovery coefficient ($F_{MME}$) was the product of partial volume effect($F_{MMF}$) and PTI. Using model I, PTI, flow, and $F_{MM}$ were estimated. For model II, we assumed that partition coefficient was another variable which could represent tissue characteristics of heterogeneity of flow distribution. Using model II, PTI, flow and ${\lambda}$ were estimated. For the simulated tissue with homogeneous flow, both models gave exactly the same estimates, of three parameters. For the simulated tissue with heterogeneous flow distribution, in model I, flow and $F_{MM}$ were correctly estimated as CH was increased moderately. In model II, flow and ${\lambda}$ were decreased curvi-linearly as CH was increased. The degree of underestimation of ${\lambda}$ obtained using model II, was correlated with CH. The degree of underestimation of flow was dependent on the degree of underestimation of ${\lambda}$. PTI was somewhat overestimated and did not change according to CH. We conclude that estimated ${\lambda}$ reflect the degree of tissue heterogeneity of flow distribution. We could use the degree of underestimation of ${\lambda}$ to find the characteristic heterogeneity of tissue flow and use ${\lambda}$ to recover the underestimated flow.

  • PDF

Study on the Aerodynamic Characteristics of Hanyang Low Speed Wind Tunnel (한양대학교 중형 아음속 풍동의 공력특성에 관한 연구)

  • Go, Gwang Cheol;Jeong, Hyeon Seong;Kim, Dong Hwa;Jo, Jin Su
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.4
    • /
    • pp.92-98
    • /
    • 2003
  • The optimum design of Hanyang low speed wind tunnel has been performed to augment flow uniformity and to reduce turbulence intensity of wind tunnel test section have to be known for reliability of wind tunnel test. The non-uniformity and turbulence intensity of Hanyang low speed wind tunnel were measured with Pilot tube and X-type hot-wire probe at various wind speeds. As the results, the non-uniformity decreases as the wind speed increases. The non-uniformity is relatively high in the proximity of the diffuser. The turbulence intensity is a little higher than design requirement in the middle of the test section.

Evaluation of the exact optimum tilt angles in elevation scanned phase array radars (고도각 주사 위상 배열 레이다에서 정확한 최적 기움각 매김)

  • Lee, Min-Joon;Park, Jeong-Soon;Song, Iick-Ho;Lee, Joo-Shik;Kim, Suk-Chan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.6
    • /
    • pp.1419-1424
    • /
    • 1998
  • In phased array antennas that scan elevation, the number of radiator rows is one of the important factors to minimizing both cost and weitht. Therefore, the antenna tilt angles having relation with element spacing are among the improtant design parameters. The exact optimum tilt angles for several types of uniformly and nonuniformly excited arrays are obtained theoretically. Four types of uniform linear arrays and Chebyshev array factors as a nonuniformly excited arrav are considered.

  • PDF

Experimental and Numerical Study on the Capillary Performance of Non-Homogeneous Micro-Post Arrays (비 균일적 마이크로 원기둥 배열을 이용한 고성능 냉각 표면)

  • Byon, Chan;Kim, Sung Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.12
    • /
    • pp.1091-1097
    • /
    • 2013
  • In this article, an advanced cooling surface based on micro-post arrays with non-homogeneous configurations is investigated and compared with conventional micro-post arrays with homogeneous configuration. The capillary performance of micro-post arrays are characterized using the capillary rate of rise experiments and numerical simulations which take into account the meniscus curvature. The experimental and numerical results show that that the capillary performance of the micro-post wick can be significantly enhanced, compared with the homogeneous type wick, by employing non-homogeneous configurations. The capillary performance is shown to be primarily a function of the solid fraction and increases linearly with decreasing solid fraction, regardless of the wick configuration, when the solid fraction is larger than 0.25. However, the capillary performance is found to be significantly reduced when the solid fraction falls below approximately 0.25.

Performance of direction-of-arrival estimation of SpSF in frequency domain: in case of non-uniform sensor array (주파수 영역으로 구현한 SpSF알고리듬: 비균일 센서 환경에서의 도래각 추정 성능)

  • Paik, Ji Woong;Zhang, Xueyang;Hong, Wooyoung;Hong, Jungpyo;Kim, Seongil;Lee, Joon-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.3
    • /
    • pp.191-199
    • /
    • 2020
  • Currently, studies on the estimation algorithm based on compressive sensing are actively underway, but to the best of our knowledge, no study on the performance of the Sparse Spectrum Fitting (SpSF) algorithm in nonuniform sensor arrays has been made. This paper deals with the derivation of the compressive sensing based covariance fitting algorithm extended to the frequency domain. In addition, it shows the performance of directon-of-arrival estimation of the frequency domain SpSF algorithm in non-uniform linear sensor array system and the sensor array failure situation.

Group Ignition of Liquid Fuel Droplets Cloud (액체연료 액적군의 집단 점화)

  • 박용열;김호영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.12
    • /
    • pp.2376-2384
    • /
    • 1992
  • A theoretical analysis is carried out to predict the characteristics of transient ignition phenomena for the spherical fuel droplets cloud with non-uniform droplet size and number density distribution. Numerical calculations are performed for various cases depending on the combinations of the major parameters such as ambient temperature and initial distributions of droplet size and number density. The results of present study show that the ignition delay decreases for higher ambient temperature and smaller droplet size. Droplets cloud of hollow type with outer concentrated distribution ignites most rapidly.

Black Body Design and Verification for Non-Uniformity Correction of Imaging Sensor and Uncertainty Analysis (영상센서의 비균일 응답특성 보정을 위한 흑체 설계 및 성능검증과 보정오차 분석)

  • Shin, Somin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.3
    • /
    • pp.240-245
    • /
    • 2013
  • Each pixel of InfraRed(IR) sensor differently responds to IR light as time elapses or the sensor on/off operation is repeated. As a result, the quality of IR sensor image is deteriorated, and therefore NUC(Non-uniformity Correction) is periodically needed for IR sensor. In this paper, in order to perform NUC in the Satellite, on-board V-grooved blackbody is designed with a baffle so that the emissivity of black body is to be higher than 0.995 as well as the temperature deviation is less than $1^{\circ}C$ in the range of the infrared wave length from 3.3 to $5.2{\mu}m$. To check its performance, the emissivity and the surface temperature of the blackbody by TRT(Transfer Reference Thermometer) and IR Micrometer scanner are measured, respectively. From the results, black body design is verified and the uncertainty of NUC is estimated through the measurement results.