• 제목/요약/키워드: 불확도 평가

검색결과 263건 처리시간 0.027초

피스톤 푸루버 개발 및 불확도 평가 (Development and Uncertainty Evaluation of Piston Prover)

  • 최해만;박경암
    • 한국유체기계학회 논문집
    • /
    • 제6권2호
    • /
    • pp.47-53
    • /
    • 2003
  • The piston prover was developed and the flow measurement uncertainty of this piston prover was evaluated according to ISO/IEC 17025. The laser interferometer, instead of the optical sensors used in the typical provers, was employed in this prover to measure accurately the testing time and the moved distance of the piston. Uncertainty was calculated with evaluation of various uncertainty factors affecting flow measurement. The expanded uncertainty (U) of the piston prover was $1.3{\times}10^{-3}$ (at the confidence level of $95\%$). This evaluation example will be useful in the flow measurement uncertainty determination of other gas flow measurement system.

점도 측정표준 불확도 평가 (Uncertainty Evaluation of Viscosity Measurement Standards)

  • 최해만;윤병로;이용봉;최용문;이상현
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.295-301
    • /
    • 2005
  • Viscosity measurement standards were evaluated according to ISO/IEC 17025. The step-up procedure was employed to calibrate a series of capillary type master viscometers. Uncertainty was calculated with evaluation of various uncertainty factors affected in viscosity measurement. The maximum expanded uncertainty(U) of the master viscometer was $3.0{\times}10^{-3}$(at the confidence level of 95 %). This evaluation example will be useful in viscosity measurement uncertainty determination of other standard measurement.

  • PDF

소닉노즐의 유량측정 불확도 평가 (Evaluation of Flow Measurement Uncertainty of Sonic Nozzle)

  • 최해만;박경암;최용문
    • 대한기계학회논문집B
    • /
    • 제25권12호
    • /
    • pp.1898-1904
    • /
    • 2001
  • Measurement uncertainty should be evaluated according to ISO/IEC 17025. In Flow measurement area, uncertainty evaluation scheme was applied to the reference flow meter, sonic nozzle. Uncertainty was calculated by evaluating various uncertainty factors affected in flow measurement. The expanded uncertainty(U) of the sonic nozzle was 2.1$\times$ 10$^{-3}$ (confidence level of 95 %). This evaluation example will be useful in flow measurement uncertainty determination of other flow meters.

3 자유도 위치 결정 기구의 위치 오차 평가 및 보정법에 대한 불확도 분석 (An Uncertainty Analysis of a Compensation Method for the Positioning Error of Three-DOF Manipulator)

  • 박재준;엄형욱;조남규
    • 한국정밀공학회지
    • /
    • 제23권7호
    • /
    • pp.51-58
    • /
    • 2006
  • This study analyzes the uncertainty of the compensation method of a sensing error of three-DOF measuring system. This compensation method utilizes a reference coordinate system using a three point by moving a position of an endpoint of a three-DOF manipulator. The coordinate transformation between the three-DOF manipulator and the measuring system is identified by the reference coordinate system. According to the concept of this compensation method, each positioning error at any position of the end-point of the manipulator is derived. Uncertainty analyses of the compensation values on the basis of sensitivity analysis and Monte Carlo simulation are used to investigate a feasibility and effectiveness of the compensation method.

몬테카를로 모사를 이용한 동압력 교정기 불확도 평가 (Uncertainty Evaluation of Dynamic Pressure Calibrator by Monte Carlo Simulation)

  • 김문기
    • 한국군사과학기술학회지
    • /
    • 제13권4호
    • /
    • pp.665-672
    • /
    • 2010
  • This paper describes Monte Carlo Simulation(MCS) to assess the uncertainty of dynamic pressure calibrator and the expanded uncertainty results that were compared by GUM approximation and MCS. MCS uncertainties were computed using defining a domain of possible inputs, generating inputs randomly using probability distribution, performing a deterministic computation repeatedly and aggregating the results. It was revealed that the expanded uncertainty between GUM and MCS was different from each other. the expanded uncertainties were 0.5366%, 0.4856%, respectively. MCS is a suitable method for determining the uncertainty of simple and complex measurement systems. It should be more widely used and studied in measurement uncertainty calculations.

200 N급 GCH4/LOx 소형로켓엔진의 형상설계와 성능시험평가 (Part II: 정상상태 지상연소시험) (Configuration Design, Hot-firing Test and Performance Evaluation of 200 N-Class GCH4/LOx Small Rocket Engine (Part II: Steady State-mode Ground Hot-firing Test))

  • 김민철;김영진;김정수
    • 한국추진공학회지
    • /
    • 제24권1호
    • /
    • pp.9-16
    • /
    • 2020
  • 200 N급 기체메탄/액체산소 소형로켓엔진의 성능시험평가 수행되었다. 산화제 공급압이 증가함에 따라 연소압과 추력이 증가하였으며, 이에 따라 비추력과 특성속도 및 그 효율이 증가하였다. 특성속도는 약 90%의 성능효율로 측정되었다. 시험조건의 연소실 종횡비 변화는 추력성능에 영향을 미치지 않았다. 또한, 시험결과의 신뢰도 확보를 위하여 불확도평가를 수행하였다.

한반도 주변해역 대기환경에 대한 싱글채널 온도추정 알고리즘의 불확도 추정 (Uncertainty Estimation of Single-Channel Temperature Estimation Algorithm for Atmospheric Conditions in the Seas around the Korean Peninsula)

  • 이종혁;강경웅;백승일;김원국
    • 대한원격탐사학회지
    • /
    • 제39권3호
    • /
    • pp.355-361
    • /
    • 2023
  • 지구 표면에 대한 정보는 기상 및 대기 역학의 이해나 인간을 포함한 동물에 큰 영향을 미치는 극한 열현상에 대응함에 있어서 핵심적인 지구 물리량이다. 지구 영역에 대한 온도를 추정하기 위하여 위성에 탑재된 열적외 센서가 널리 활용되어 왔는데, 정밀한 활용을 위해서는 온도 추정 과정의 불확도에 대한 이해가 선행되어야 한다. 하지만 온도추정 불확도에 영향을 미치는 많은 요소 중에서 한반도 주변의 환경 하에서의 온도추정 알고리즘의 불확도 산정에 대한 연구는 미미하였다. 본 연구에서는 한반도 주변의 대기 및 해양 조건하에서 범용성이 높은 single-channel 알고리즘의 불확도를 추정하는 연구를 수행하였다. 알고리즘의 입력자료로 필요한 재분석자료(reanalysis)의 영향성을 평가하기 위하여 두 가지의 재분석자료, 즉 fifth generation of European Centre for Medium-Range Weather Forecasts reanalysis of the global climate and weather (ERA5)와 Modern-Era Retrospective analysis for Research and Applications-2 (MERRA-2)를 사용하였고, 복사전달모델은 MODerate resolution atmospheric TRANsmission (MODTRAN)을 사용하였다. MODTRAN 모의와 온도 추정 정확도 검증에 사용되는 현장 관측 수온은 한반도 인근 해역에 위치한 해양 기상 부이(buoy)로부터 획득했다. 실험 결과, 알고리즘 불확도는 대기 수증기량에 따라서 선형에 가깝게 증가하는 것을 확인하였고, 가장 건조한 조건에서는 약 0.35K 그리고 평균적으로 0.45K 가량의 불확도가 발생함을 확인하였다. 이러한 결과는 재분석자료의 종류에 상관없이 유사하게 도출되어 알고리즘이 가지는 순수한 불확도라고 추정할 수 있었다.

측정불확도를 적용한 차량검지기 속도측정 성능평가방법 개발 (Development of an Performance Evaluation Method for Vehicle Detector Speed Measurement Applying Uncertainty in Measurement)

  • 이환필;김용만;강동윤
    • 한국도로학회논문집
    • /
    • 제14권2호
    • /
    • pp.165-174
    • /
    • 2012
  • 본 연구에서는 차량검지기의 속도측정 성능평가방법을 개발하였다. 개발된 성능평가방법에서는 오차요인들을 기준속도에 반영하며 측정불확도의 개념을 적용하였다. 기존연구, 통계적 처리기법, 기존교통단속장비 및 차량검지시스템의 속도측정 성능평가방법 등에 대한 고찰을 통해 기존평가방법의 문제점을 도출하고 개선된 성능평가방법을 개발하였다, 실제 현장에 설치된 차량검지기에 대해서 기존평가방법과 개발방법을 적용해본 결과 기존평가방법은 평가기준에 적합하나 개발방법은 평가기준을 만족시키지 못하고 있다. 이러한 결과는 기존성능평가방법이 측정 시의 오차요인들을 충분히 고려하지 못해서 평가대상장비의 성능을 고평가할 가능성이 있음을 의미하며, 반면에 개발모형은 측정 시의 변동요인인 오차를 고려하므로 기존평가방법 보다 정확함을 나타낸다.

정보행태 불확신성에 관한 연구 - 경영학분야 박사과정 연구자들을 중심으로 - (Uncertainty Study: Information Seeking Behaviors of Doctoral Students in Business Management)

  • 김양우
    • 한국비블리아학회지
    • /
    • 제23권1호
    • /
    • pp.65-89
    • /
    • 2012
  • 본 연구는 근거이론(Grounded Theory)방식을 이용하여 학술연구를 목적으로 한 이용자들의 불확신성과 관련된 정보추구행태를 조사하였다. 이론적 표집에 의하여 17명의 경영학 박사과정 연구자들을 대상으로 질문지, 심층적 인터뷰, 정보탐색과정상의 생각을 말하기 방식(Think-aloud descriptions)을 통한 자료수집이 이루어졌고 수집된 자료는 근거이론의 지속적인 비교분석에 의해 분석되었다. 연구결과는 정보요구의 식별, 정보시스템의 선정, 탐색어의 선택, 정보시스템의 이용 및 탐색결과의 평가 등 5단계에 걸친 이용자 불확신성을 식별하였다. 각 불확신성과 관련, 불확신성의 긍정적인 측면이 조사되었다. 연구결과의 주요 시사점은 정보시스템 및 서비스의 개선과 관련된다.

능동 적외선열화상 기법을 이용한 이면결함 검출에서의 측정 불확도 (Measurement Uncertainty on Subsurface Defects Detection Using Active Infrared Thermographic Technique)

  • 정윤재;김원태;최원재
    • 비파괴검사학회지
    • /
    • 제35권5호
    • /
    • pp.341-348
    • /
    • 2015
  • 능동적 열화상 기법은 재료의 수동적 열적결함에 있어 기존의 적외선 열화상 기법에 비해 우수한 결함 검출능력을 보이는 것으로 알려져 있다. 적외선 비파괴 검사는 지금까지 다양한 검출 기법에 대한 발전이 이루어졌으나 신뢰성에는 다소 의문이 있다. 따라서 본 논문에서는 위상잠금 열화상기법을 적용하여 각각 다른 결함의 크기와 깊이의 인공결함을 갖는 SM45C 시험편을 가지고 제안된 기법을 검증하고, 불확도를 평가하여 위상잠금 열화상 기법을 이용한 결함의 크기측정에 대한 신뢰성을 검토하였다.