• Title/Summary/Keyword: 불확도

Search Result 605, Processing Time 0.033 seconds

The Concept of Measurement Uncertainty and the GUM (측정불확도의 개념과 GUM)

  • Jong Wha Lee
    • Journal of the Korean Chemical Society
    • /
    • v.67 no.5
    • /
    • pp.319-332
    • /
    • 2023
  • Ever since the development of the Guide to the Expression of Uncertainty in Measurement (GUM) in 1993, the concept of measurement uncertainty has been considered a core concept in metrology and the importance of proper uncertainty evaluation has continuously been increasing. Unfortunately, few papers in Korean are available that introduce the concept of measurement uncertainty and the GUM correctly and in sufficient detail. This review describes in detail the mathematical, historical, and philosophical background behind the concept of measurement uncertainty and the GUM, and also discusses some special aspects of uncertainty evaluation in chemical analysis.

Calculation of Uncertainty in Measuring Heat Release Rate in Room Corner Test (룸코너 시험기의 발열량 측정에 대한 불확도 산정)

  • Noh, Kwang-Chul;Kim, Chi-Hoon;Lee, Seung-Chul;Lee, Duck-Hee
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.16-22
    • /
    • 2012
  • In fire test, accurate heat release rate measurements provide important information to define the fire safety characteristics of products. The calculation of heat release rate depends on the errors of measuring parameters in experimental set-up. In this study, the uncertainty factors of heat release rate in the room corner test facility, which is installed at Korea Railroad Research Institute, were analyzed. Through the fire testings for the KTX interior materials, the uncertainties of heat release rate were calculated. Results showed that uncertainty was high in the initial stage of fire test and gradually decreased with the growth of fire. The oxygen concentration was a major factor contributing to the combined relative standard uncertainty.

A Study on the Modeling and Propagation to Evaluate Uncertainties in Measurement Results (측정결과의 불확도산정을 위한 모델링과 불확도 전파에 관한 연구)

  • 김종상;조남호
    • Journal of the Korea Society of Computer and Information
    • /
    • v.8 no.4
    • /
    • pp.165-175
    • /
    • 2003
  • The concept of measurement uncertainty has been recognised for many years since "Guide to the Expression of Uncertainty in Measurement" was published 1993 by ISO. This study firstly propose the mathematical model to evaluate uncertainty considering the dispersion of samples because the mathematical model of a measurement is an important to evaluate uncertainty, and it must contains every quantify which contribute significantly to uncertainty in the measurement result. Secondly the standard uncertainty of the result of a measurement, namely combined standard uncertainty is evaluated using the law of propagation of uncertainty, what is termed in GUM method. In GUM method, a measurand is usually approximated by a linear function of its variables by the transforming its input quantities. Furthermore central limit theorem is applied to the input quantity. However the mathematical model of a measurement is generally not always a linearity function, and a distribution function of input or output quantity is not necessarily normal distribution. Then, in some cases GUM method is not favorable to evaluate a measurement uncertainty. Therefore this study propose a new method and its algorithm which use the Monte-carlo simulation to evaluate a measurement uncertainty in both case of linearity or non-linearity function. function.

  • PDF

Assessment of Uncertainty for Discharge Measurement using Velocity-Area method (유속-면적법으로 측정된 유량에 대한 측정 불확도 평가)

  • Kim, Jongmin;Kim, Dongsu;Kim, Seojun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.104-104
    • /
    • 2016
  • 소규모 하천에서의 평수기 유량 측정은 일반적으로 지점식 초음파 유속계, 프로펠러 유속계 등을 활용해 도섭법으로 측정된 유속 측정성과를 기반하여 유속-면적법으로 산정된다. 유속-면적법으로 측정된 유량 측정 성과는 횡방향 측선의 수, 수심방향 측점의 수, 측정 시간, 수심 등 제반 측정 인자에 의해 영향을 받고 유량 불확도는 각 인자 별 오차에 영향을 받는다. ISO 748 (2007)과 ISO 1088 (2007)은 유속-면적법 적용방법, 현장 측정 가이드라인, 불확도 인자 별 적용 요건에 따른 오차, 최종 유량 불확도 산정 기법을 제시하였다. 따라서, 국내외 유량조사 기관에서는 유속면적법을 적용할 경우, ISO에서 제시된 인자 별 오차 및 유량 불확도 산정 기법을 기반으로 유량 불확도를 산정해왔다. ISO 748과 1088은 다양한 규모의 실제 하천에서 관측된 자료를 기반으로 횡방향 측선 수, 수심방향 측점 수 (2점법, 3점법 등), 측정 시간 등과 관련된 인자 별 오차를 표로 상세하게 제시하였고 실무에서는 별도 추가 검증없이 사용해 왔다. 그러나, ISO에서 유속-면적법 유량 측정 불확도를 평가하기 위해 사용된 측정자료는 유량을 제어하기 힘들고 유속 측정 상황이 유출 조건 별로 상이한 현장 자료를 기반으로 하였고, 상대적으로 정확도가 낮은 프로펠러유속계를 기반으로 1960년대에 관측된 자료들을 주로 활용하여 도출되었다. 따라서, 본 연구에서는 기존 ISO에서 제시한 유속-면적법에 필요한 인자들의 오차를 정밀 실규모 실험을 통해 재산정하여 기존 ISO 748과 1088에서 제시한 인자별 오차의 적정성을 검증하고자 하였다. 이를 위해 흐름을 안정적으로 통제할 수 있는 건설기술연구원 안동 하천실험센터의 완경사수로(A2)에서 정상상태의 폭 7m, 수심 1m, 유속 약 1m/s의 흐름을 유지한 후, 유속 측정 정확도가 우수한 micro-ADV를 활용하여 공간적으로 매우 정밀하게 유속을 측정하고, 수심은 Total Station을 기반으로 흐름 발생 전에 정밀 측정하였다. 오차 분석 결과, ISO 규정에서 제시한 오차와 본 실험의 결과로 도출된 인자들의 오차는 상당한 차이를 보였다. 따라서, 본 연구 결과로 도출된 유속-면적법의 인자 별 오차는 실험이 수행된 소하천 규모의 하천에서 도섭법으로 산정된 유량의 불확도를 평가할 경우에 활용될 것으로 기대된다.

  • PDF

A study on quality assurance and evaluation of uncertainty for the analysis of natural gas (천연가스 분석의 불확도 평가 및 품질 보증을 위한 연구)

  • Woo, Jin-Chun;Kim, Young-Doo;Bae, Hyun-Kil;Lee, Kang-Jin;Her, Jae-Young
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.490-497
    • /
    • 2006
  • The sources of uncertainty in the analysis of liquified natural gas (LNG) process are evaluated. The uncertainty sources evaluated are the repeatability of measurement, non-linearity of GC, the uncertainty of standard gas used for calibration, difference of gas sampling and deviation after GC calibration and major revealed sources are the non-linearity of GC, the uncertainty of standard gas and the deviation after GC calibration. The determined values and uncertainties of methane and ethane as the major components are $90.0%mol/mol{\pm}1.9%$ (relative and 95% level of confidence) and $6.26%mol/mol{\pm}0.08$ (relative and 95% level of confidence), respectively. The contribution of uncertainty varies depending on the source of uncertainty and gas component. In the case of methane, non-linearity of GC, the uncertainty of standard gas and deviation after GC calibration contribute 0.28%, 0.25% and 0.24% of relative expanded uncertainty, respectively.

Assessment of ADCP discharge measurement uncertainty by GUM framework through large scale experiment (실규모 실험을 통한 GUM 기반의 ADCP 유량 측정불확도 산정)

  • Kim, Jong Min;Kim, Dong Su
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.18-18
    • /
    • 2021
  • 초음파 도플러 유속계(ADCP)는 초음파를 이용하여 하천의 유속 및 수심을 측정하는 장비로 기존의 지점식 유속계와는 다르게 수심방향 유속분포와 수심을 한번에 측정하게 되며, 보트를 이용하여 하천을 횡단하게 되면 기존의 유속-면적법을 이용하는 방식보다 간편하고 빠르게 한 단면의 유량을 측정할 수 있다. 이와 같은 이점으로 인해 국내뿐만 아니라 해외에서도 대하천에서부터 중·소규모의 하천까지 다양한 범위에서 유량을 측정하는 장비로서 사용되어지고 있다. ADCP의 측정 유량은 유량관측소에서 수위-유량관계식을 구축할 때 사용하고 있으며, 이렇게 제공되는 유량은 하천의 중·장기 계획 수립, 수공구조물의 설계 및 수문·수리분야의 연구에 활용되고 있다. 하지만 ADCP의 유량측정은 ADCP의 미측정 영역의 유량 추정, ADCP 잠김깊이의 정확도, 하안에서의 고정 측정시간 등 ADCP의 측정 과정이나, 유량 추정 방법에 따라 영향을 받게 되며. 이외에도 하천의 수심, 하상의 상태와 같은 측정 조건에 따라서도 정확도의 변화가 발생할 수 있다. 측정결과의 정확성을 향상시키고, 신뢰도가 높은 자료를 제공하기 위해서는 ADCP의 유량 측정결과에 대한 불확도를 발생시키는 요인들에 대한 분석과 이를 감소시킬 수 있는 방법을 찾는 것이 중요하다. 1993년 ISO, BIPM, IFCC 등 6개 기구에서는 측정불확도를 산정하기 위한 측정불확도 산정 지침서(GUM, Guide to the expression of Uncertainty of Measurement)를 제시하였다. GUM 표준안은 측정과정에서 발생하는 다양한 불확도 요인들을 불확도 전파법칙을 통해 전체 불확도를 산정하는 방식으로 WMO와 ISO의 유량 측정분야에서도 GUM 표준안을 측정불확도 산정 기준으로 공인하여 사용하고 있다(JCGM 100, 2008; ISO 25377, 2020). 이에 본 연구에서는 GUM 표준안을 이용하여 ADCP로 측정된 유량의 측정불확도를 산정하는 방법을 개발하고 각 요인들에 대한 실험 및 분석을 진행하였다. ADCP의 측정 정확도를 분석하기 위한 실험은 자연에 가까운 형상을 모의하고 있고, 소하천 규모를 갖고 있는 하천연구센터에서 수행하였으며, 요인들에 대한 분석 방법 및 총 불확도를 계산하는 방법에 대하여 제시하였다.

  • PDF

Estimation of Measurement Uncertainty in Evaluation of Tensile Properties (인장 물성 측정 불확도 평가)

  • Huh, Y.H.;Lee, H.M.;Kim, D.J.;Park, J.S.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.1
    • /
    • pp.73-78
    • /
    • 2010
  • Estimation of tensile properties measurement uncertainty of material was carried out. Sources of uncertainty affecting the measurement of tensile properties were classified and analyzed. The models for uncertainty evaluation of measurands to be determined from tensile test, such as elastic modulus, yield strength and tensile strength, were suggested and derived from the mathematical relations, corresponding to the respective measurands, and the measuring quantities by calculating each sensitivity coefficient of the quantities. Based on these models, the uncertainty of the tensile properties was evaluated from the experimental data of SUS316LN determined according to ISO 6892.

Uncertainty Analysis for Subsonic Wind Tunnel Testing (아음속풍동 시험에서의 불확도 해석)

  • Kwon, Ki-Jung;Sung, Bong-Zoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.4
    • /
    • pp.123-130
    • /
    • 2002
  • Aerodynamic results for an airplane model produced in a subsonic wind tunnel testing inadvertently include errors which are added during model preparation, data acquisition, manipulation, and/or describing the results. Predicting or analyzing uncertainty for the final results is necessary for trusting them and for applying them to real airplane. This paper describes the analytic and systematic method for calculating and describing the uncertainties of aerodynamic coefficients.