• 제목/요약/키워드: 불평형 전원전압

검색결과 86건 처리시간 0.023초

전류 고조파와 불평형 전원 전압 보상을 위한 직렬형 능동전력필터에 관한 연구 (A Study on the Series Active Power Filter for Harmonic Reduction and Unbalanced Source Voltage Compensation)

  • 오재훈;한윤석;김영석;원충연;최세완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.191-194
    • /
    • 2001
  • In this paper, we propose a series active power filter control method to compensate current harmonics and unbalanced source voltage. The system is composed of series active power filter and shunt passive filer that are tuned 5th and 7th harmonics. In this conventional system, series active power filter complements drawbacks of the shunt passive filter, namely improves harmonic compensation characteristics, and compensates unbalanced source voltage. In the proposed algorithm, compensation voltage for harmonic reduction is calculated by performance function, and compensation voltage for unbalanced source voltage is calculated in based on a synchronous reference frame. So, ultimate compensation voltage is sum of those two compensation voltages. By computer simulation, we verify the excellency of proposed method.

  • PDF

누설변압기가 부착된 전원 불평형 3상 전압형 PWM 컨버터 운전법 (Operating Method of 3 Phase Voltage type PWM Converter for Unbalanced Voltage with Leakage Transformer)

  • 전지용;김영춘;조유환;이근홍
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.125-127
    • /
    • 2005
  • In this paper, the control algorithm of DC source device for inverter starting is proposed and the control method for compensating unbalance system source on operating time in the voltage type PWM converter with driving and regenerative faculty is suggested. The maintaining way of balancing condition for converter of AC source is used the compensating unbalanced status by current control loop. Because it is possible that the unbalanced System control is used to leakage transformer not equaled reactance by each phase in rectifier system, the proposed H/W and control algorithm of rectifier system is contributed to minimize of device and rising efficiency.

  • PDF

입력 전원 외란 상황에서의 신경회로망 기반 전류 보상기를 이용한 매트릭스 컨버터의 출력 전류 개선 (Improving the Output Current of Matrix Converter under Abnormal Input Voltage Conditions using a Neural Network Compensator)

  • 이은실;박기우;이교범
    • 전력전자학회논문지
    • /
    • 제15권3호
    • /
    • pp.199-206
    • /
    • 2010
  • 매트릭스 컨버터는 3상의 입력 전원이 전력용 반도체 스위치의 제어를 통해 3상의 부하에 직접 연결되는 에너지 변환 장치이다. 에너지 저장을 위한 직류단이 없어 매트릭스 컨버터의 입력 전류는 부하 전류와 스위치 상태에 직접 의존한다. 그러므로 불평형 또는 왜곡된 입력 전압은 원치 않은 출력 고조파 전류의 원인이 된다. 본 논문에서는 매트릭스 컨버터의 입력 전원 외란 상황에서 출력 전류를 개선하는 신경회로망 기반 전류 보상기를 제안한다. 제안된 기법 타당성과 유효성을 시뮬레이션과 실험을 통해 증명한다.

PSCAD/EMTDC를 이용한 ESS의 누설전류 모델링에 관한 연구 (A Study on Modeling of Leakage Current in ESS Using PSCAD/EMTDC)

  • 김지명;태동현;이일무;임건표;노대석
    • 한국산학기술학회논문지
    • /
    • 제22권2호
    • /
    • pp.810-818
    • /
    • 2021
  • ESS의 누설전류는 PCS(Power Control System)측 누설전류와 계통불평형 전류로 인한 누설전류로 구분되는데, PCS측의 누설전류는 정상 상태 운전 시, IGBT(Insulated Gate Bipolar Transistor) 스위칭의 전압 변화량과 IGBT와 방열판 사이에 존재하는 기생 커패시턴스에 의해 발생한다. 또한, 계통불평형 전류에 의한 누설전류는 불평형 부하로 인해 발생한 불평형 전류가 Yg-∆ 결선방식의 3각 철심이 적용된 태양광전원 연계형 변압기의 중성선을 통해 ESS로 유입된다. 따라서, 본 논문에서는 방열판 유도공식을 통해 산정한 기생 커패시턴스에 의하여 PCS측의 누설전류 발생 메커니즘을 제시하고 또한, 계통불평형에 의한 ESS측의 누설전류 발생 메커니즘을 제안한다. 이를 바탕으로, 배전계통 상용해석 프로그램인 PSCAD/EMTDC를 이용하여 배터리부, PCS부, AC전원부로 이루어진 PCS측의 누설전류 발생 메커니즘과 배전 계통부, 불평형 부하부, ESS부로 이루어진 계통불평형에 의한 ESS측의 누설전류 발생 메커니즘을 모델링하고, 누설전류의 특성을 평가한다. 상기의 모델링을 바탕으로 시뮬레이션을 수행한 결과, 외함의 저항과 접지저항의 크기에 따라 PCS측의 누설전류는 7[mA]에서 34[mA]로, 계통불평형에 의한 배터리 외함으로 흐르는 누설전류는 3.96[mA]에서 10.76[mA]로 증가하여 배터리측에 큰 영향을 미침을 알 수 있었다.

전원 전압의 불평형과 고조파 전류 보상 및 역률 개선 기능을 가지는 능동전력 필터 (Active Power Filter Compensating for Source Voltage Unbalance/Current Harmonics and Power Factor Correction)

  • 이종건;석줄기;이동춘
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.787-790
    • /
    • 2004
  • In this paper, a novel control scheme compensating for source voltage unbalance and current harmonics and power factor correction in unified active power filter systems combined with shunt passive filters is proposed, where no low/high-pass filter are used in deriving the reference voltage for compensation. Using digital all-pass filters, the phase angle and the reference voltages compensating for harmonic current and unbalanced voltage are derived from the positive sequence component of the unbalanced voltage. The amplitude of d-axis current in a series filter is controlled as zero for power factor correction. The validity of the proposed control scheme has been verified by experimental results.

  • PDF

전류 고조파와 불평형 전원 전압을 보상하는 직렬형 능동전력 필터와 병렬형 수동전력필터 병용시스템의 새로운 제어법 (A Novel Control Method of Combined System consists of Series Active Power Filter and Parallel Passive Power Filter to Compensate Current Harmonics and Unbalanced Source Voltages)

  • 오재훈;한윤석;김영석;원충연;최세완
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권12호
    • /
    • pp.615-623
    • /
    • 2001
  • In this paper, we study a series active power filter to compensate current harmonics and unbalanced source voltages. Conventional control methods for compensating unbalanced source voltages use source voltages to calculate compensation voltages, and in addition use load voltages to regulate load voltages. But the proposed control method uses load voltage to compensate unbalanced source voltages and regulate load voltages. And we propose a control method to reduce current harmonics which can calculate compensation voltages directly from source currents and load voltages. By well-matched operation of two control methods, the series active power filter can compensate current harmonics, unbalanced source voltages, and regulate load voltages. We compose a combined system of the series active power filter and parallel passive filters to confirm a validity of proposed control methods. The results from experiments are presented to demonstrate effectiveness of the proposed method.

  • PDF

영구자석형 동기기에 의한 가변속 풍력발전 시스템의 PSCAD/EMTDC 시뮬레이션 모델 개발 (PSCAD/EMTDC Simulation Model of Variable Speed Wind Power Generation System Using Permanent Magnet Synchronous Machine)

  • 김정재;송승호
    • 전력전자학회논문지
    • /
    • 제10권6호
    • /
    • pp.610-617
    • /
    • 2005
  • 가변속 풍력발전 시스템의 시뮬레이션 모델을 PSCAD/EMTDC 기반으로 개발하였다. 개발된 시뮬레이션 모델은 바람 모델, 회전자 다이나믹스, 동기 발전기, 전력 변환기, 변압기, 배전 선로, 무한 모선 등으로 구성되어 있다. 특히 블레이드의 공기역학적 특성과 전력 변환기의 제어 전략도 포함되어 실질적인 풍력발전기의 동작 특성을 시뮬레이션 할 수 있다. 개발된 시뮬레이션 모델을 이용하여 입력 풍속의 변동, 발전기 주변 부하의 변동, 계통측 전원 전압의 불평형 등의 다양한 조건에서 풍력발전기의 과도 상태 거동 특성을 확인하였다. 본 연구 결과는 앞으로 가변속 풍력발전기와 전력계통의 연계 운전시 신뢰성을 높이고 전력 시스템을 보호하기 위한 기초자료로서 활용될 수 있을 것으로 기대된다.

전압 불평형과 발전기 출력 변동을 이용한 분산전원의 단독운전 판단 기법 (Islanding detection method for distributed generations using the change of the voltage unbalance and the output power of DG)

  • 강용철;장성일;이지훈;차선희;김연희;이병은;김용균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.240-241
    • /
    • 2006
  • Islanding operations of DG usually occur when power supply from the main utility is interrupted due to several reasons but the DG keeps supplying power into the distribution networks. These kinds of islanding conditions cause negative impacts on protection, operation, and management of distribution systems. Therefore, it is necessary to effectively detect the islanding conditions and swiftly disconnect DG from distribution network. This paper proposes the islanding detection algorithm for DG using the change of the voltage unbalance and the output power of DG. The proposed method effectively combines the conventional parameters for detecting the islanding conditions. The proposed methods were verified using the radial distribution network of IEEE 34 bus.

  • PDF

직렬 능동전력필터와 병렬 수동필터를 이용한 고조파 전류 저감 및 불평형 전원 전압 보상에 관한 연구 (A Study on Current Harmonics Reduction and Unbalanced Source Voltage Compensation Using Series Active Power Filter and Parallel Passive Filter)

  • 오재훈;고수현;한윤석;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.196-199
    • /
    • 2001
  • This paper deals with current harmonics and unbalanced source voltages compensation using combined filter system. Filter system consists of a series active filter and parallel passive filters. Passive filters were a traditional method to compensate current harmonics, so those were installed in power system widely. The active filter can be a substitution to improve filtering characteristics and complement drawbacks of the passive filter. The combined system of the active power filter and passive filter can has a better compensation performances and economical goods. The series type active power filter injects compensation voltage into power system by transformers. It's compensation principle is able to applicate for voltage compensation. A new control algorithm for series active filter to compensate current harmonics and unbalanced source voltages is proposed. In the proposed algorithm, a compensation voltage for harmonic reduction is calculated directly by instantaneous reactive power theory, and a compensation voltage for unbalanced source voltage is calculated in based on a synchronous reference frame. By experiments, we show validity of proposed compensation method.

  • PDF

불균등 임피던스 선로를 갖는 인버터기반 분산전원의 부하전압 불평형을 보상하는 드룹 제어 (Droop Control to Compensate Load Voltage Unbalance for Inverter-based Distributed Generations with Unequal Impedance Lines)

  • 양원모;김현준;한병문
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1193-1203
    • /
    • 2016
  • This paper proposes a droop control scheme to compensate the unbalanced line-to-line voltage of unbalanced 3-phase load which is coupled with two inverter-based distributed generations through unequal impedance lines. Unbalanced line-to-line load voltages occur due to using single-phase loads, which brings about bad effects on the coupled inverters and the distributed generations. In order to compensate the unbalanced line-to-line voltages, a positive sequence voltage control was used for sharing the active and reactive power and a negative sequence control was used for reducing the negative sequence voltage. The feasibility of the proposed scheme was first verified by computer simulations, and then experiments with a hardware set-up built in the lab. The experimental results were compared with the simulation results to confirm the feasibility of the proposed scheme.