• Title/Summary/Keyword: 불편감 종류

Search Result 33, Processing Time 0.024 seconds

The Status of Contact Lens Wearing, Management and Eye Health Awareness Among Female University Students in Jeju Area (제주지역 여대생들의 콘택트렌즈 착용 및 관리 실태와 눈건강 인식)

  • Choi, Ji Young;Song, Yun Young;Byun, Jong Chul
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.203-214
    • /
    • 2016
  • Purpose: The purpose of this study is to analyze the status of contact lens wearing, management and awareness of eye health knowledge among female university students in Jeju area and to utilize the basic data for education and management of contact lens. Methods: Data for this study were collected from the 236 female university students in Jeju area who have a contact lens experience from May 1, 2016 to June 11, 2016. Results: We found the status of contact lens wearing and management of subjects and there were different correlations between discomfort and awareness of eye health knowledge among the subjects who have different characteristics. There were also correlations in discomfort, the average days of contact lens wear per week, initial wearing day and action when they have any discomfort in some contact lens wearers. Conclusions: We realized the status of contact lens wearing and management of female university students and it suggests appropriate contact care education and sustainable management system are need to be established for considering daily average wearing time, the type and material of contact lens wear and main discomfort and so on.

Changes in Subjective Discomfort, Blinking Rate, Lens Centration and the Light Transmittance of Lens Induced by Exceeding Use of Daily Disposable Circle Contact Lenses in Dry Eyes (일회용 써클소프트렌즈의 일일 초과착용 시 유발되는 건성안의 자각적 불편감, 순목횟수, 중심안정 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kang, Shin Young;Chang, Jung Iee;Han, Arum;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.153-162
    • /
    • 2014
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmittance of lens caused by the use longer than recommended wearing time of daily disposable circle contact lenses (circle lens) in dry eyes. Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 30 dry eyes with smaller tear volume than normal eyes in their twenties free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, lens centration on corneal surface and visible light transmittance of lens were recorded at every case and compared. Results: The circle lens wearers complained subjective discomfort and quit the lens wearing when they wore the circle lens longer than 10 hours even though there were some difference according to the lens materials of daily disposable circle lens. However, around 20% of dry eyes could wear the circle lens made of non-ionic materials longer than 40 hours. Dry eyes showed most sensitive feeling of subjective discomfort against the circle lens made of etafilcon A among three different lens materials. On the last day of lens wearing, the representative subjective discomforts were irritation, stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, blinking rate was significantly increased about 20~30% regardless of lens materials when it compared with the values right after lens wearing. On the last day of lens wearing, the vertical direction of lens centration was shifted to pupil center however, its distribution in horizontal direction was wide compared with the distribution right after lens wearing. Especially, the centration of etafilcon A lens was unstable. Furthermore, the visible light transmittance of 3 different circle lenses in dry eyes has significantly been reduced around 15% averaged. Conclusions: From these results, it was known that the increase of dryness and stiffness caused by overusage of daily disposable circle lens induced excess irritation and decreased visible light transmittance and caused significant more blinking, which provoked lens decentration. It was also revealed that dry eyes showed sensitive reaction subjectively and objectively against the overusage of circle lens made of high water content/ionic lens material even there were some difference of the degree depending on the individual and the lens material. Thus, this research can be suggested as the basic reference for the education about some unexpected problems and the side effect caused by the wearing of circle lens in dry eyes.

The Clinical Study on Spectacle Wearers of Highschool Students (고등학생 안경착용자의 착용상태에 관안 임상적 연구)

  • Kim, Sang-Kyun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.19-27
    • /
    • 2004
  • The purpose of this study is to survey spectacle wearers's way of thinking through the questionaire and to investigate their wearing conditions through fitting conditions, the pantascopic angle, vertex distance, the coincidence of vertical and horizontal distance between optical center of the lens and pupillary distance of the eye in random selected 150 ametropic corrective wearers in the age of 17 to 19. The results are as follows : 1. The most popular causes of physical complaints in the ex-wearing spectacle are frame pressure(34.0%), slipping forward(30.0%) and most popular visual complaints are blur vision(30.0%) and asthenopia(20.0%). 2. The most common physical or visual complaints in the present wearing spectacle are slipping forward(30.0%), pressure (50.0%), color(10.0%). 3. Myopic glasses wearers accounted for 56.7% of the subjects, the others were compound myopic astigmatism. In 60% of the subjects' binocular diopter did not coincide. 4. In the pantascopic angle of the both eyes coincide in 66.7% of the subjects. The average of pantascopic angle is $10.07^{\circ}$. 5. In the vertex distance of the both eyes coincided in 65.3% of the subjects. the he average of vertex distance is 13.6 mm. 6. Among 150 eyes with monocular, the vertical distance between optical center of the lens and pupillary distance of the eye is within the RAL-RG 915 that is tolerance of ophthalmic dispensing in German Standards in 82 eyes (54.6%). 7. Among 150 eyes with monocular, the horizontal distance between optical center of the lens and pupillary distance of the eye is within the RAL-RG915 that is tolerance of ophthalmic dispensing in German Standards in 86 eyes(57.3 %).

  • PDF

Changes in Subjective/Objective Symptoms and the Light Transmissibility of Lens Associated with Overusage of Daily Disposable Circle Contact Lenses in Normal Eyes (일회용 써클소프트렌즈의 초과 착용에 의한 정상안의 자·타각적 증상 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kwon, Hae Lim;Choi, Sae Ah;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.429-439
    • /
    • 2013
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmissibility of lens caused by over-usage of daily disposable circle contact lenses (circle lens). Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 20 normal eyes free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, non-invasive break-up time, lens centration on corneal surface and visible light transmissibility of lens were recorded at every case and compared. Results: The circle lens wearers complained discomfort when they wore the circle lens more than 15 hours, in excess of 8 hours being the recommended wearing time and the most circle lens wearers quit the lens wearing when they wore more than 30 hours. On the last day of lens wearing, the representative subjective discomforts were stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, a tendency of increased blinking rate and decreased NIBUT was observed when it compared with the values right after lens wearing. On the last day of lens wearing, the lens centration was shown to be decentrated from the pupil center compared with the centration right after the wearing. These changes in lens centration and blinking rate were consistently shown in all cases of lens wearing however, the difference in the degree of subjective and/or objective change was present depending on lens materials and subjects. The visible light transmissibility of circle lens has largely been changed. Conclusions: From these results, it was thought that the decreased NIBUT induced dryness and stiffness and decreased visible light transmissibility caused more blinking when daily disposable circle lens was exceedingly used, which provoked lens decentration and subjective discomfort. However, the difference of subjective and/or objective change was largely varied in accordance with the lens material types and individuality and thus it may occur some unexpected problems by the individual base. Therefore, the education about the necessity to comply with the recommended wearing time and the problem will be essential.

Disparity and Image Characteristics of Stereoscopic Video Affecting on Viewing Safety (스테레오스코픽 비디오의 시청안전성에 영향을 미치는 변위 및 화면 특성)

  • Seo, Young-Ho;Bae, Yun-Jin;Kim, Woo-Youl;Kim, Dong-Wook
    • Journal of Broadcast Engineering
    • /
    • v.17 no.5
    • /
    • pp.789-807
    • /
    • 2012
  • The purpose of this paper is to find various disparity factors in conjunction with situations and contexts of the contents that cause viewer's discomfort, which is to make a content production guideline for viewer's safety, eventually. As a methodology, we extract the experimental data by letting various viewers push a pre-defined key as long as they feel discomfort during watching stereo 3D contents. For each contents, we extract the disparities and disparity changes for the focal point, vicinity of the focal point (ROI, region of interest), and the whole image. For each contents, each point or part of contents is analyzed to find the factors causing discomfort with the two prepared data with watching the contents in 3D. Then, all the analyzed data are re-analyzed to find the strength of each factor. The results from the analyses are explained from the factors having relatively high strength first. It includes the factors that are not known as well as the ones that we can already guess.

Factors for the Prediction of Pain in Terminally Ill Cancer Patients in Hospice Units (호스피스 병동에 입원한 말기 암환자의 통증 예측요인)

  • Yong, Jin-Sun;Han, Sung-Suk;Ro, You-Ja;Hong, Hyun-Ja
    • Journal of Hospice and Palliative Care
    • /
    • v.5 no.2
    • /
    • pp.125-135
    • /
    • 2002
  • Purpose : The purpose of this study was to investigate the impact of depression, discomfort, spirituality, physical care, and opioid use on pain with terminally ill cancer patients in the hospice units. Method : The convenient sample of this study consisted of 58 terminally ill cancer patients at three hospice units in university-affiliated hospitals. Patients were interviewed with structured questionnaires. The data was analyzed using ANOVA, Pearson correlation coefficient, and multivariate multiple regression. Result : The results of this study were as follows : 1) The mean age of the participants was approximately 57 years. Regarding diagnosis, stomach cancer showed the highest frequency (24.1%), followed by lung cancer (17.2%) and rectal cancer (13.8%). Regarding motivation for admission to the hospice unit, the majority of the participants indicated pain control (67.2%), followed by spiritual care (39.7%), and symptom relief (27.6%). 2) The mean pain level measured by VAS was 5.13 (${\pm}2.61$). Regarding pain type, the highest pain frequency the participants experienced was deep pain (53.4%), followed by multiple pain (20.7%), intestinal pain (17.3%), and neurogenic (5.2%) and superficial pain (3.4%). 3) Regarding the factors influencing pain, the pain level was significantly affected by the depression level (P<0.01) and the opioid use (P<0.01). Conclusion, In summary, the higher the level of pain the terminally ill cancer patents had the higher the depression level as well as the opioid use. Thus, health care professionals need to continuously provide holistic care for them to die comfortably.

  • PDF

Study of a Measuring Method for 3DTV Visual Fatigue based on EEG test (EEG(뇌파)실험을 기반한 3DTV 시각피로도 연구)

  • Lee, Kook-See;Moon, Nammee
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.258-259
    • /
    • 2011
  • 3DTV를 시청하는 경우 조절거리는 TV 화면까지의 거리에 해당하지만, 수렴거리는 좌 우 영상의 화면 시차에 따라 영상의 도출과 후퇴의 깊이가 변하게 되고 수렴거리와 조절거리에 불일치가 발생하게 된다. 3DTV의 입체영상을 시청할 때 발생하는 시각적 불편감은 이러한 수렴과 조절과정의 불일치가 가장 주된 원인으로 알려졌다. 본 연구에서는 입체영상의 시각적 자극으로 눈에서부터 시작된 시각피로감이 인체에 전해지는 단계, 즉 정보의 최종 통합기관인 뇌에 전달결과로서의 생체적 반응을 EEG 방법으로 측정하였다. 3DTV 시청 전 후의 뇌파측정과 뇌기능지수 분석에 의한 방법으로 실험한 결과 시각피로는 ${\delta}$, ${\theta}$, ${\alpha}$, SMR, ${\beta}$Low, ${\beta}$High 파 등 여러 종류의 뇌파 밴드에 영향을 미치고 있었다.

  • PDF

Types of malocclusion and oral health effect index(OHIP-14) according to recognition of orthodontic treatment (부정교합 종류에 따른 교정치료의 인식과 구강건강영향지수(OHIP-14))

  • Yoon, Hyun-Seo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.434-442
    • /
    • 2017
  • The purpose of this study was to examine the influence of type of malocclusion and orthodontic treatment awareness on quality of life among orthodontic patients in the region of Busan as well as to develop an educational program tailored to the type of malocclusion as a way to improve quality of life. A survey was conducted for approximately 6 months from December, 2015, and the answer sheets from 472 respondents were analyzed. The most common painful area was the teeth, and this case was most predominant in the respondents with level 2 malocclusion, who differed from others in that regard (p<0.001). Regarding the relationship between satisfaction with orthodontic treatment and quality of life, respondents who were more satisfied currently and who were neither quite confident nor quite unconfident were ahead of their counterparts in quality of life. Concerning the reason for receiving orthodontic treatment, quality of life was lower among patients who started to receive treatment due to pronunciation problems (p=0.013), chewing difficulty (p<0.001), and temporomandibular joint click sound (p<0.001). With regard to influential factors on oral health-related quality of life, time for starting to receive orthodontic treatment was most influential (p<0.001), followed by current satisfaction (p<0.001), changes in confidence (p=0.003), self-rated teeth status (p=0.008), and type of occlusion (p=0.019). Therefore, accurate analysis of the oral health status of orthodontic patients and customized oral health education are required to improve quality of life even during the period of orthodontic treatment.

Use of Menstrual Sanitary Products in Community Women of Childbearing Age (지역사회 가임기 여성의 생리대 사용 조사)

  • Hyunju Dan;Heeja Jung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.401-407
    • /
    • 2023
  • This study is a descriptive study to identify the patterns of use of menstrual sanitary products among community women of childbearing age. The participants were 1,571 women between the ages of 19 and 40, and data collection was conducted through online and mobile surveys from September 2020 to August 2021. As a result, 88.9% of the participants were using disposable menstrual pad, 5.6% tampons, 3.1% cloth menstrual pad, and followed by others(2.4%), including menstrual cups. The differences of type of menstrual sanitary products according to general characteristics showed significant in age(p=.006), marital status(p=.005), education level(p=.002), annual salary(p=.018), experience of pregnancy(p=.036), and menstrual regularity(p=.022). More than half of the participants(53.8%) responded that cloth menstrual pads were 'very safe' or 'safe,' but 27.9% and 20.1% of disposable menstrual pads and tampons, respectively. The difference in menstrual distress according to the type of menstrual sanitary products showed that tampon users had a higher menstrual discomfort score for the most recent menstruation(F=4.092, p=.017) and 4 days before menstruation(F=4.178, p=.016) than users of disposable menstrual pad or cloth menstrual pad. Therefore, it is necessary to continuously investigate the use of menstrual sanitary products by women of childbearing age and its relationship with reproductive health.

Changes in Subjective Symptom, Tear Film Stabilization and Blinking Rates when Wearing RGP Lenses with Different Polishing Conditions for Certain Period of Time (연마상태가 다른 RGP렌즈의 일정기간 착용 시 렌즈착용자의 자각적 증상, 눈물막 안정 및 순목횟수 변화)

  • Park, Mijung;Kim, Hyo Gyum;Bae, Jun Seob;Park, Jung Ju;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.31-42
    • /
    • 2014
  • Purpose: The present study was conducted to investigate the effect of the physical properties of RGP lens induced by lens polishing on the actual wearer's subjective comfort, the tear film break-up time and the blinking rate as a follow-up study that revealed the relationship between the lens physical properties during lens manufacturing and lens wearer's factors. Methods: RGP lenses made from the three different polishing conditions (25, 50 and 100 seconds) were applied on 28 eyes of 17 subjects, aged 20 to 29 years, without any known disease and surgical history in the eyes. While the subjects were asked to wear the RGP lenses longer than a week, the questionnaire for the comfortability was administered everyday. Subjective and objective tear break-up time and blinking rate of the wearers were further measured. Results: The wearer's subjective comfortability showed some difference in the type of discomfort and satisfaction score according to the polishing status when wearing RGP lenses made from different polishing conditions longer than a week, and a bigger difference in satisfaction score induced by polishing condition was especially shown in experienced RGP lens wearer rather than un-experienced wearer. In the case of RGP lens wearer compared with the ones without the wearing experience, as the wearing time increased subjective and objective tear break-up time were increased and the blinking rate was decreased. However, subjective and objective tear break-up time were tended to decrease with even longer wearing time when wearing the RGP lens made from the polishment for 100 seconds. Conclusions: These results confirmed that the optimization of physical properties of the lens may not give the same effect on the wearer's subjective and objective symptoms and other factors when actual wearing. From the results, it can suggest that the success rate of RGP lens wear may be changed by physiological factors such as the stabilization of wearer's tear film, comfortability and lens wearing experience when wearing RGP lens based on 'The manufacturing standard for soft contact lens/hard contact lens' provided by Korea Food and Drug Administration.