• Title/Summary/Keyword: 분할 타설

Search Result 33, Processing Time 0.021 seconds

A Numerical Study on the Characteristics of Plastic Shrinkage Cracking on Concrete Slab with Sequential Placement (분할타설되는 콘크리트 슬래브의 소성수축균열 특성에 대한 해석적 연구)

  • Kwak, Hyo-Gyoung;Ha, Soo-Jun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4A
    • /
    • pp.795-808
    • /
    • 2006
  • In this paper, an analytical method which can predict the occurrence of plastic shrinkage cracking on concrete slabs with sequential placement is proposed on the basis of the numerical model introduced in the previous study. The influence of many design variables on plastic shrinkage cracking such as the number of layers and the time interval between layers is quantitatively analyzed through parametric studies using the analytical method. In advance, two equations are introduced to take into account the effect of sequential placement on the plastic shrinkage cracking of concrete slab; The first one is to calculate the time at which the surface of concrete slab begins to dry, and the second one is to determine the critical time interval to prevent the surface drying of previously placed concrete layers. The timing of curing and the sequence of concrete placement, which are important for the prevention of plastic shrinkage cracking, can be effectively planned using the introduced both equations without any rigorous analysis.

Hydration Heat Analysis of Mass Concrete considering Heat Transfer Coefficient and Hydration Heat Difference (수화발열량차 및 열전달계수 변화를 고려한 매스콘크리트의 수화열 해석)

  • Han, Seung-Baek;Lee, Seong-Su;Shin, Hyo-Bum;Kim, Ho-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.249-252
    • /
    • 2008
  • In recent large-scale structures, as mass concrete type structure is frequently applied to the building, temperature crack due to hydration heat needs to be considered. Since a volume change is internally or externally restricted in a mold after placing concrete, temperature crack of mass concrete takes place. By this reason, the reduction method to control this crack is required. In this study, low heat mixture and hydration heat difference is used to execute the analysis of hydration heat, considering the changes of heat transfer coefficient according to curing conditions and block placement of mass concrete. For the analytical modelling, original portland cement and concrete of low heat mixture are placed in the upper and lower payer, respectively. A convection boundary condition is fixed because mass concrete of block placement is characterized by the difference of mold form and curing condition. Through the analysis results considering the changes of low heat mixture, block placement, and heat transfer coefficient, we check out the temperature and stress distribution and analyze the temperature crack reduction effect.

  • PDF

Research on the Efficient Manufacturing Method of Photocatalyst Concrete according to the Type and Mixing Ratio of Photocatalyst (광촉매 종류 및 혼입률에 따른 효율적 광촉매 콘크리트의 제조 방법에 관한 연구)

  • Park, Gi-Joon;Park, Jung-Jun;Kwak, Jong-Won;Kim, Sung-Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.69-77
    • /
    • 2019
  • In this study, we evaluated the mechanical properties and nitrogen oxides removal characteristics according to the type and incorporation rate of the photocatalyst and investigated the method of separated placement for the production of economical and efficient photocatalyst concrete. As a result, when the photocatalyst incorporation rate was 5%, the highest compressive strength and elastic modulus were measured. As a result of evaluating the nitrogen oxides removal performance by the photocatalytic reaction, as the photocatalyst incorporation rate increased, the nitrogen oxide removal rate increased. At this time, the nitrogen oxides removal performance of photocatalyst P-25 was better than the NP-A. In consideration of economic efficiency, we have provided a method of separated placement for casting a constant thickness of concrete surface with photocatalyst concrete and evaluated the integrated performance at this time. As a result, it appears to be equal to or higher than mechanical performance and durability performance as compared with Plain, and it is judged that the integrated behavior is satisfied.

Hydration Heat Analysis of Seongdeok Cofferdam (성덕 다목적댐 가물막이댐의 수화열 해석)

  • Kim, Jin-Keun;Chu, In-Yeop;Jang, Bong-Seok;Ha, Jae-Dam;Park, Byung-Kook;Kim, Jeong-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.481-484
    • /
    • 2008
  • The temperature crack of concrete structure is caused by the phenomenon which the concrete volume is restricted in the inside or outside part due th the temperature variations induced by the hydration heat of cement. And mass concrete structures are weak in temperature crack. Seongdeok multi-purpose dam is gravity dam which is being constructed in Cheongsong-gun, Gyeonsangbuk-do. Upstream cofferdam was constructed to examine the temperature crack due to hydration heat and to decide the height of placement. Therefore this study performed the hydration heat analysis of Seongdeok upstream coffer dam to analyze the hydration heat according to different height of placement and to compare with measured results.

  • PDF

A Long Term Characteristics of Hydraulic Conductivity and Tensile Strength of Natural Fiber Drain with respect to Installation Conditions (천연섬유배수재의 타설 조건에 따른 장기 투수계수 및 인장강도의 특성)

  • Jang, Jin-Young;Jang, Yeon-Soo;Cho, Sam-Duck
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.4
    • /
    • pp.15-21
    • /
    • 2008
  • Long term changes of hydraulic properties and tensile strength of natural fiber drain (NFD) are analyzed and compared with those of intact NFD's. NFD was buried in distilled water, two types of seawater and clay soils obtained in southern and western parts of Korea, Kwang-Yang and Si-hwa. Specimens are taken out in 0, 3, 9 and 18 month intervals, and durability tests of the NFD are performed. Hydraulic conductivity of the NFD samples decreased compared with that of intact NFD samples, because clay particles easily passed to coarsened mesh of filters and clogged the porous stone below and reduced hydraulic conductivity. Tensile strength of drains from the soil bucket is reduced larger than those in the seawater and the distilled water. Strength reduction was higher in summer than winter.

An Experimental Study on the Period of Cold Joint Occurrence Effecting Shear Bond Performances of UHSCC (콜드조인트 발생시간이 초고강도 섬유보강 시멘트 복합체의 전단 접착 성능에 미치는 영향에 관한 실험적 연구)

  • Kim, Min-Seong;Yang, Hyun-Min;Lee, Han-Seung;Cho, Keun-hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.1
    • /
    • pp.25-32
    • /
    • 2016
  • The purpose of this study is to evaluate the performance on the compressive bonding shear strength of ultra-high strength steel fiber reinforced cementitous composites(UHSCC). As a result of compressive bonding shear strength through Direct shear test, It was found that the specimen($150{\times}150{\times}150mm$) of NC(Normal concrete) + NC showed similar compressive bonding shear strength at whole experimental level. On the other hand, the specimen of UHSCC + UHSCC showed decrease of compressive bonding shear strength from after 30 minutes of the retarded placement than 0 minute. As a result of analyzing failure mode of bonding interface, It was found that the specimen of NC + NC showed mixed failure at whole experimental level. In case of the specimen of UHSCC + UHSCC, it showed interface failure from the specimen that are 30 minutes, 60 minutes and 90 minutes of delay of concrete placing. As a result of analyzing XRD test in terms of the placement interface on the specimen of NC and UHSCC, relatively much amount of $SiO_2$ was detected from the specimen of UHSCC than that of NC. It is judged that the most of main components of coating film shown in the specimen of UHSCC is $SiO_2$. In conclusion, it is judged that UHSCC which is made from after 30 minutes of delay of concrete placing is unable to be used as structural member because of deterioration of bonding performance. From later study, it is judged that the improvement of bonding performance from the part of cold joint occurrence is necessary through the interface preparation method.

A study of the Bent of Hydration Analysis Underground Pier Footing by Constrution Stages (시공단계를 고려한 교각기초의 수화열해석)

  • Park Weon-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.3
    • /
    • pp.223-230
    • /
    • 2005
  • Lately, massive concrete structures are increasingly built. Mass concrete structures are cast in many stages with construction joints. Individually constructed segment exhibit different heat source properpies and time dependent properties. As such construction stages must be incorporated in a heat of hydration analysis model to truly reflect a real construction process. Thermal stress analysis is conducted to find the way of controlling the thermal crack of pier footing mat in this paper. The footing mat model fur the analysis is $12m\times14m$ area and 3m height. This study show the process of construction stage and analyzes the results for a foundation structure constructed in 2 stage pours.

  • PDF

A Study on Crack Control of Tunnel Lining Concrete with Large Section (대단면 터널 라이닝 콘크리트의 균열저감 연구)

  • Kim, Wan-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.509-512
    • /
    • 2008
  • The lining concrete of water tunnel is a much capability to occur crack due to drying shrinkage and vibrator compaction etc. Because of crack of concrete induce structural problem and decrease durability of concrete, it is need to reduce crack of concrete. In this an Analytical study to analyze the effect of curing of concrete and compaction on the lining concrete. As the results, it was found that control of construction condition into curing of concrete and compaction improve on construction efficiency of the lining concrete.

  • PDF

Development of Temperature Control Technology for Massive Machine Foundations (기계기초 매스콘크리트의 균열제어를 위한 온도관리기법의 개발)

  • Huh, Taik-Nyung;Son, Young-Hyun;Lee, Suck-Hong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.4
    • /
    • pp.227-233
    • /
    • 2001
  • 최근 비약적인 경제발전에 힘입어 장대교량, 항만, 댐, 도로, 원자력 발전소 등과 같은 대규모 기간구조물의 건설이 증가하고 있으며, 구조물은 대형화 혹은 고강도화되는 추세에 있다. 특히, 전술한 구조물을 매스콘크리트로 가설하게 되면 초기재령시에 수화열로 인한 균열이 발생할 가능성이 매우 높기 때문에 효율적인 매스콘크리트의 개발과 매스콘크리트 구조물의 설계기술 및 시공방법이 중요한 연구대상으로 등장하게 된다. 본 논문에서는 가로 52.6m, 세로 14.4m, 높이 8.5m의 기계기초 매스콘크리트의 시공에 적합한 온도관리기법을 다음과 같은 단계로 제안하고자 한다. 먼저 온도상승요인을 최소화하는 콘크리트의 배합비를 산정한다. 산정된 콘크리트의 열특성을 측정하기 위해 단열온도실험을 수행하여 각종 열특성상수와 단열온도 상승곡선식을 도출한다. 이와 같은 열특성치를 콘크리트 구조체에 적용하여 열응력해석을 수행한다. 이와 같은 열응력해석을 통하여 구조물의 분할타설높이에 따라 온도균열이 발생하지 않는 콘크리트 내외부의 온도차를 결정한다. 이때 열응력해석에 범용 유한요소 프로그램인 Diana을 사용한다. 콘크리트의 타설은 현장조건과 타설시점을 최대로 고려하고 양생방법으로 콘크리트 내외부의 온도차를 최소화하기 위해 이중단열효과가 있는 거푸집과 가열장비을 사용한다. 또한 콘크리트의 온도관리를 위하여 구조물 내외부에 온도게이지를 매립하고 30분마다 계측을 수행하면서 콘크리트 내외부 온도차가 허용 해석범위를 유지하도록 한다. 양생기간은 7-10일 정도를 유지한다. 전술한 온도관리기법을 통하여 완공후 수평정밀도가 기초의 허용침하량으로 환산하여 $1{\mu}m$ 인 고정밀도의 기계기초는 완벽하게 시공되었다. 따라서 매스콘크리트의 온도균열을 제어할 수 있는 시공방법으로 제안한다. 또한 매스콘크리트의 내외부 온도차를 단열온도실험과 온도해석으로부터 정한 값이내로 제어하고 충분한 양생관리를 병행하면 수화열에 의한 콘크리트의 온도균열을 최소화할 수 있을 것으로 기대한다.

  • PDF

Realistic Analysis Method for Continuously Block-Placed Mass Concrete Structures Considering Block Size and Sequence of Concrete Placement (매스 콘크리트 구조물의 연속 분할타설시 타설블록의 크기 및 타설순서를 고려한 합리적인 수화열 해석)

  • 오병환;전세진;유성원
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.3
    • /
    • pp.59-67
    • /
    • 1999
  • The mass concrete structures are generally constructed in an incremental manner by deviding the whole structures by a series of many blocks. The temperature and stress distributions of any specific block are continuously affected by the blocks placed before and after the specific block. For an accurate analysis of mass concrete structures, the sequence of all the blocks must be accordingly considered including the change of material properties with time for those blocks considered. The purpose of this study is to propose a realistic analysis method which can take into account not only the influence of the sequence, time interval and size of concrete block placement on the temperatures and stresses, but also the change of material properties with time. It is seen from this study that the conventional simplified analysis, which neglects material property changes of some blocks with time and does not consider the effect of adjacent blocks in the analysis, may yield large discrepancies in the temperature and stress distributions of mass concrete structures. This study gives a method to choose the minimum number of blocks required to obtain reasonably accurate results in analysis. The study provides a realistic method which can determine the appropriate size and time interval of block placement, and can be efficiently used in the design and construction of mass concrete structures.