• Title/Summary/Keyword: 분포하중

Search Result 1,097, Processing Time 0.028 seconds

Prediction of Extreme Design Wave Height (극한 설계 파고의 추정)

  • Chon, Y.K.;Ha, T.B.
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.33 no.1
    • /
    • pp.145-152
    • /
    • 1996
  • In this study, the technique to evaluate the extreme design wave height of certain return period is developed from the given measured or hindcasted sea state data of concerned area for limited period. By using the order statistics and Monte Carlo Simulation method, the best fit probability distribution function with proper parameters describing the given wave height data is chosen, from which extreme design wave height can be predicted by extrapolation to the desired return period. The fitness and the confidence limit of the chosen probability function are also discussed. Application calculation is carried out for the wave height data given by applying the Wilson wave model theory to major 50 typhoon wind data affecting Korean South coast during the year from 1938 to 1987.

  • PDF

Stress Distribution Analysis of Jointed Concrete Pavements (줄눈콘크리트포장의 하중응력분포 해석)

  • Park, Je-Seon;Lee, Joo-Hyung;Kim, Tea-Kyung;Yun, Kyung-Ku
    • Journal of Industrial Technology
    • /
    • v.18
    • /
    • pp.363-370
    • /
    • 1998
  • This study focused on the development of an alternative stress estimation procedure to instantly calculate the critical stresses bonded concrete pavement. Closed form analysis is commonly used to analyze pavement structures. This type of analysis assumes linearelastic material properties and static loading conditions. The well-known ILLI-SLAB finite element program was used for the analysis. Bonded concrete overlay analyzed the stress distribution, behavior and load carrying capacity under track load is made evaluation standard of bonded concrete overlay. In the study, the following results were derived ; The properties of strength is that compress and 3-point bending strength of existing pavement is deteriorated with $184kg/cm^2$, $59kg/cm^2$ but compress and splitting tensile strength of overlay is satisfied with $465kg/cm^2$, $45kg/cm^2$. Load transfers is happen at adjacent slab by interlocking under track load. The stress distribution under interior, corner and edge load is described high loading position surrounding then loading position.

  • PDF

Analysis on Fracture Toughness of Ultra Heavy Thick EH36-TMCP Plate Welded Joint (조선용 극후물재 EH36-TMCP강의 파괴인성 해석)

  • Bang, Hee-Sun;Bang, Han-Sur;Joo, Sung-Min
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.93-93
    • /
    • 2009
  • 본 연구에서는 EGW, FCAW 공정 적용에 따른 고강도 극후판 EH36-TMCP강 용접부의 역학적 거동 및 파괴인성 $K_{IC}$ 을 규명하기 위해, 먼저 열분포, 열탄소성 수치해석을 통하여 용접부의 역학적 거동(용접잔류응력, 소성변형율 등의 크기, 분포, 발생기구)을 고찰하였다. 그리고 이때 얻어진 잔류응력을 초기응력으로 하여, 잔류응력과 외력의 복합하중에 대한 파괴인성 $K_{Ic}$ 특성을 해석하였다. 용접공정별 균열이 존재하는 용접부의 파괴기준을 살펴보면, EGW용접부의 경우가 FCAW용접부의 경우에 비해 균열의 성장이 다소 용이하여 $K_{IC}$ 값이 다소 낮게 나타났다. EGW용접부의 파괴인성 $K_{IC}$ 경우 중첩된 경우(복합하중)가 순수 외력만 작용하는 경우보다 파괴 인성치가 다소 감소하는 경향을 보이고, a/W가 작을 경우 중첩의 경우가 순수 외력만의 경우보다 파괴인성치 차이가 크나, a/W가 증가함에 따라 그 차이가 점차 없어지는 것으로 나타났다. 반면, FCAW용접부의 경우 균열길이가 작은 범위에서는 중첩된 경우가 순수 외력만 작용 할 경우보다 파괴 인성치가 다소 증가함을 보이지만, a/W가 증가함에 따라 순수 외력만의 작용의 경우와 중첩의 경우의 파괴인성 차이가 없는 것으로 나타났다.

  • PDF

Finite Element Analysis Approach for the Stress of Digging Part of Garlic Harvesters (유한요소해석을 이용한 마늘 수확기 굴취부의 응력분석)

  • Kim, Kyu-Bong;Lee, Myung-Hee;Kim, Dae-Cheol;Cho, Yongjin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.11
    • /
    • pp.78-86
    • /
    • 2020
  • A stress analysis was performed to verify the stability of the digging part of a garlic harvester. A finite element analysis was performed to examine the distribution and concentrated loads on the digging part of the blade and contact plate. Moreover, the stability and maximum deformation of the digging part were determined. Under a distributed load, the maximum principal stress, total deformation, and minimum safety factor ranged from 64-128 MPa, 0.35-0.70 mm, and 2.9-5.7, respectively. The analysis results for the distribution load indicated that the maximum stress occurred at the center of the blade. In contrast, under the concentrated load, the maximum principal stress, total deformation, and minimum safety factor ranged from 66-247 MPa, 0.35-0.79 mm, 1.48-5.53, respectively. The analysis results for the concentrated load indicated that stress and deformation were larger toward the edge and center, respectively.

Study on Tensile Properties of Carbon Fiber Reinforced Polymers (CFRP) Laminate with Strain Distribution (변형률 분포를 가진 탄소섬유복합체의 인장특성에 대한 연구)

  • Kim, Yun-Gon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.25-33
    • /
    • 2020
  • To investigate the relationship between strain distribution and tensile properties of brittle material, five types of tensile coupon of carbon fiber reinforced polymer (CFRP) modified the tab portion in order to have a strain distribution including S0, SD1, SD2, SV1, SV2 were tested. The ultimate stress and strain of SD2 and SV2 which was intended to have larger strain distribution were smaller than those of SD1 and SV1, that was more clearly shown in the test results of the symmetric coupons (SV series) than the asymmetric coupons (SD series). In addition, the ultimate stress and strain of most coupons with strain distribution in this study were decreased when compared to the control group with uniform strain. These results were analyzed in various ways through 1) the average of the strain values directly measured by the strain gages, 2) the converted strain calculated by dividing the total deformation by the effective length, and 3) the ultimate effective strain derived from both the elastic modulus and the ultimate load. The values measured by strain gage indicates response of the local region precisely, but it does not represent the response from whole section. However, the converted strain and effective strain can supplement disadvantage of gage because they represent the average response of whole section. In particular, the effective strain can provide rupture strain conservatively, which can be utilized in practice, when the value obtained by strain gage was not effective due to gage damage or abnormal gage readings near ultimate load. This value provides a value that can be used even when partial rupture has occurred and is reasonably useful for specimens with strain distribution.

Implications of the effects of gravity load for earthquake resistant design of multistory building structurtes (고층건물의 내진설계에 미치는 중력하중의 영향)

  • 이동근;이석용
    • Computational Structural Engineering
    • /
    • v.6 no.3
    • /
    • pp.67-80
    • /
    • 1993
  • This paper presents the results of an analytical study to evaluate the inelastic seismic response characteristics of multistory building structures, the effects of gravity load on the seismic responses and its implications on the earthquake resistant design. Static analyses for incremental lateral force and nonlinear dynamic analyses for earthquake motions were performed to evaluate the seismic response of example multistory building structures. Most of considerations are placed on the distribution of inelastic responses over the height of the structure. When an earthquake occurs, bending moment demand is increased considerably from the top to the bottom of multistory structures, so that differences between bending moment demands and supplies are greater in lower floos of multistory structures. As a result, for building structures designed by the current earthquake resistant design procedure, inelastic deformations for earthquake ground motions do not distribute uniformly over the height of structures and those are induced mainly in bottom floors. In addition, gravity load considerded in design procedure tends to cause much larger damages in lower floors. From the point of view of seismic responses, gravity load affects the initial yield time of griders in earlier stage of strong earthquakes and results in different inelastic responses among the plastic hinges that form in the girders of a same floor. However, gravity load moments at beam ends are gradually reduced and finally fully relaxed after a structure experiences some inelastic excursions as a ground motion is getting stronger. Reduction of gravity load moment results in much increased structural damages in lower floors building structures. The implications of the effects of gravity load for seismic design of multistory building structures are to reduce the contributions of gravity load and to increased those of seismic load in determination of flexual strength for girders and columns.

  • PDF

An Experimental Study on the Ultimate Strength and Deformation Capacity of Composite Beams with Eccentric Web Openings (편심유공합성보의 종국내력 및 변형능력에 관한 실험적 연구)

  • Choi, San Ho;Seo, Seong Yeon
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.5 s.48
    • /
    • pp.595-604
    • /
    • 2000
  • Web openings of large beams provide space for wiring, piping, and duct work to provide for proper drainage, pipes and duct must be slightly sloped with the attendant result that all web openings can not be centered on the centroidal axes of the beams. Test specimens are made for opening-depth to beam-depth ratio of 0.5 and for eccentricities of the opening center line of 10% from middepth of the beam because of the proximity of the opening edge to the flange. In this paper, available test results and theories relating to the strength of composite beams having eccentric rectangular openings are surveyed and experiments were carried out to examine the structural behaviors. In all the tests in this paper good agreement is demonstrated with maximum loads measured in tests, and observed failure modes Furthermore, compared with analytical values and experimental values of interaction diagram between moment and shear capacity were safed as it is scattered with outer part of the analytical values.

  • PDF

Measurement of Stress and Displacement Fields in Particle Assembly subjected to Shallow Foundation Loading via Photoelasticity Technique (광탄성 기법을 이용한 얕은 기초 하중을 받는 입상체의 응력 및 변위장 측정)

  • Byeon, Bo-Hyeon;Jung, Young-Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.1947-1955
    • /
    • 2013
  • The purpose of this paper is to present an photoelasticity technique for measuring the displacement and stress distribution in particle assembly subjected to shallow foundation loading. Photoelastic measurement technique was employed to visualize the force transmission of a particle assembly. A model assembly bounded by a steel frame was built by stacking bi-dimensional circular particles made of polycarbonate elastomer. Each particle was coated by a thin photoelastic sheet so that the force transmission represented by bright light stripes can be visualized. In a contacted particle, both magnitude and orientation of principal stress difference can also be measured via the photoelasticity technique. The different distributions of the contact stresses at the initial loading and near the failure were quantitatively compared. The photoelastic patterns and displacement fields observed in the pre-failure state disappears immediately after the buckling of confined force chains.

Evaluation on Flexural Performance for Light-Weight Composite Floor with Sound Reduction System (층간소음 대응형 경량합성바닥판에 대한 휨성능 평가)

  • Bae, Kyu Woong;Lee, Sang Sup;Park, Keum Sung;Heo, Byung Wook;Hong, Sung Yub
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.3
    • /
    • pp.241-250
    • /
    • 2014
  • The purpose of this study is to propose structural technologies on the light-weight composite floor systems in the unit modular and to evaluate structural performance of the composite floor through flexural experiments. The flexural experiments were carried out on total nine specimens(each three type in shape) using steel flat deck and truss deck. From the results of test, all specimens showed the same failure patterns which exhibited deflection at the center of the specimens due to flexural deformation before concrete crushing at the upper of specimens. Also, we know that the proposed floors satisfied in serviceability and would be safe sufficiently. The ratio of experimental yield load by theoretical nominal load was the distribution of 0.86 to 1.27 with an average 1.04. Coefficient of variation in distribution showed good agreement.

Influence of Lateral Ballast Resistance on the Buckling Fragility Curve of the Continuous Welded Rail Tracks (장대레일 궤도의 좌굴 취약도 곡선에 대한 도상횡저항력의 영향)

  • Bae, Hyun Ung;Choi, Jin Yu;Lee, Chin Ok;Lim, Nam Hyoung
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.185-185
    • /
    • 2011
  • 기존 장대레일 궤도의 안정성 평가는 궤도 매개변수에 대하여 고정된 안전측의 값을 사용하는 결정론적인 해석에 의존해서 평가되어져 왔다. 그러나 실제현장의 궤도조건은 많은 영향인자들에 의해 그 특성이 불확실하게 변하고 있다. 따라서 온도하중에 의한 궤도 좌굴에 영향을 미치는 궤도 구성인자들의 불확실성 및 임의성을 보다 합리적으로 고려하기 위해서 확률론적 기법을 적용하는 것이 필수적이다. 본 연구에서는 기존 본 연구진에 의해 개발된 장대레일 궤도의 좌굴확률 평가시스템을 이용하여 좌굴 취약도 곡선을 나타내었으며, 궤도 좌굴에 영향을 미치는 주요변수 중 하나인 도상횡저항력에 대한 영향을 분석하였다. 좌굴확률 평가시스템에서는 장대레일 궤도의 좌굴확률을 산정하기 위하여 구조물의 안정과 파괴를 판단할 수 있는 기준을 한계상태방정식으로 표현하고, 이 한계상태방정식으로부터 확률론적 기법 중 하나인 AFOSM(Advanced First Order Second Moment) 방법을 이용하여 파괴확률의 간접적인 지표인 신뢰도지수(${\beta}$)를 통해 좌굴확률을 계산한다. 한계상태방정식에서 구조물의 강도(보유성능)에 해당하는 부분은 궤도의 허용좌굴온도이고, 하중(요구성능)에 해당하는 부분은 레일온도하중으로써 현재 레일온도와 중립온도의 차로 반영된다. 허용좌굴온도 산정에 고려되는 주요변수는 곡선반경(Radius), 도상횡저항력(Lateral Ballast Resista nce), 연직도상강성(Vertical Ballast Stiffness), 궤도 틀림량(Misalignment), 틀림길이(Half Wave Length), 열차운행속도(Velocity)이다. 각 확률변수들이 갖는 확률분포는 모두 정규분포로 가정하였다. 궤도의 기하학적 특성은 곡선반경 5,000m에 대해 고려하였으며, 열차는 KTX의 제원을 사용하여 정지된 상태에서 고려하였다. 틀림량과 틀림길이는 이에 대한 통계적 특성자료가 부족하여 확률변수로 고려하지 않고 결정론적 값으로 취급하였다. 레일온도의 통계적 특성치는 본 연구진에 의해 구축된 기후요소 및 레일온도 DB를 근거로 결정하였으며, 중립온도는 선로관리지침에 따라 $25{\pm}3^{\circ}C$를 기준으로 결정하였다. 또한 도상횡저항력은 실측 데이터를 참고로 하여 평균값에서 10%의 변동량을 갖는 것으로 보고 통계적 특성치를 결정하였다. 도상횡저항력이 좌굴확률에 미치는 영향을 매우 큰 것을 알 수 있었으며, 레일온도 $60^{\circ}C$일 때 도상횡저항력이 증가하면서 감소되는 좌굴확률이 도상저항력이 커질수록 그 감소량이 작아지는 것을 알 수 있었다.

  • PDF