• Title/Summary/Keyword: 분진입자

Search Result 165, Processing Time 0.021 seconds

A Study on the Diesel Spray by Means of Image Analysis of Shadow Photographs (陰影寫眞의 畵像解析에 의한 디이젤 噴霧의 硏究)

  • 장영준;신본무정;동경공
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.2
    • /
    • pp.319-327
    • /
    • 1988
  • A new measuring method is proposed, which measures the atomization characteristics of a non-evaporating, axi-symmetric diesel spray by means of an image analysis of high speed shadow photographs. The instantaneous sauter mean diameter and the fuel concentration in the spray are calculated of the splay axis and in the radial direction and the data of the fuel injection rate, using an onion peeling model. Some examples of application of this method to eight different diesel sprays are demonstrated, and the results are compared to predicted results by the conventional immersion method and a quasi-steady one dimensional spray model.

Enhancement of Allergen-related Eosinophilic Airway Inflammation and Airway Hyperresponsiveness by House Dust Particles in Mice (생쥐에서 가정분진 입자로 인한 항원관련 호산구성 기도 염증과 기도 과민성의 증대)

  • Lim, Heung-Bin;Kim, Seung-Hyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.3
    • /
    • pp.321-328
    • /
    • 2008
  • The number of patient with allergic asthma and atopy have increased in the cities of Korea steadily. In order to elucidate the primary factor, we investigated whether the house dust particles collected from an apartment of the middle classes has promoting effects of allergen-related airway inflammation and airway hyperresponsiveness. Mice were treated with 0.1 mL of 1 mg/mL of house dust particles suspension by intratracheal instillation once weekly for 10 weeks combined with ovalalbumin (OVA) sensitization. Intratracheal instillation of house dust particles and OVA sensitization caused an increase in the level of serum L-lactate dehydrogenase (LDH), immunoglobulun-E (IgE) and histamine, and an elevation in respiratory resistance. It also enhanced infiltration of eosinophils in the bronchoalveolar lavage fluid (BALF) of mice, IgE and eotaxin expression in blood, and T helper type 2 cell derived cytokine levels such as of interleukin (IL)-4, IL-13 and IL-5 in the BALF. However, it did not influence T helper type 1 cytokine such as interferon-gamma in the BALF. These results indicate that house dust particles elevate allergen-related airway inflammation and airway hyperresponsiveness in mice and may play an important role in the aggravation of asthma and atopy in Korea.

Characteristics According to the Size Distributions of Respirable Particulate During Yellow Sand Episode in Kosan, Jeju Island (황사기간도안 제주, 고산지역에서 호흡성 분진의 입자 분포 특성)

  • Kim, Jeong-Ho;Ahn, Jun-Young;Han, Jin-Seok;Lee, Jeong-Joo
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.3
    • /
    • pp.91-96
    • /
    • 2003
  • This study was intended as an investigation of characteristics of background site atmospheric respirable particulate matters(RPM), and fine particles(<2.5 ${\mu}{\textrm}{m}$). The particle size distributions during the phenomenon of Yellow Sand(YS) occurs from April, 2001. Atmospheric aerosol particulate matter was directly collected on the Jeju island between 1 to 30, April, 2001 using an eight-stage cascade impacter(particle size range: 0.43-11 ${\mu}{\textrm}{m}$), and cyclone separator(cut size: 2.5, 10 ${\mu}{\textrm}{m}$). The episode of YS observed in background monitoring site, Kosan and appeared 2 times at sampling period. The mass concentrations of fine and coarse particles for YS episode were 34.2 and 59.6 $\mu\textrm{g}$/㎥, respectively, which were significantly increased amounts compared to 13.3 and 13.0 $\mu\textrm{g}$/㎥ for NonYS(NYS). Most size distributions had two peaks, one at 0.43∼.65 ${\mu}{\textrm}{m}$ and the other at 3.3${\mu}{\textrm}{m}$4.7 ${\mu}{\textrm}{m}$. The result of analysis of water-soluble ion component indicated that sulfate was mainly ion component, but nitrate and calcium ion was significantly increased at the YS episode.

Evaluation of Air Quality in the Compost Pilot Plant with Livestock Manure by Operation Types (축분 퇴비화시스템 운용방식에 따른 실내 대기오염 평가)

  • Kim, K.Y.;Choi, H.L.;Ko, H.J.;Kim, C.N.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.283-294
    • /
    • 2004
  • Air quality in the livestock waste compost pilot plant at the Colligate Livestock Station was assessed to quantity the emissions of aerial contaminants and evaluate the degree of correlation between them for different operation strategies; with the ventilation types and agitation of compost pile, in this study. The parameters analyzed to reflect the level of air quality in the livestock waste compost pilot plant were the gaseous contaminants; ammonia, hydrogen sulfide, and odor concentration, the particulate contaminants; inhalable dust and respirable dust, and the biological contaminants; total airborne bacteria and fungi. The mean concentrations of ammonia, hydrogen sulfide, and odor concentration in the compost pilot plant without agitation were 2.45ppm, 19.96ppb, and 15.8 when it was naturally ventilated, and 7.61ppm, 31.36ppb, and 30.2 when mechanically ventilated. Those with agitation were 5.50ppm, 14.69ppb, and 46.4 when naturally ventilated, and 30.12ppm, 39.91ppb, and 205.5 when mechanically ventilated. The mean concentrations of inhalable and respirable dust in the compost pilot plant without agitation were 368.6${\mu}g$/$m^3$ and 96.0${\mu}g$/$m^3$ with natural ventilation, and 283.9${\mu}g$/$m^3$ and 119.5${\mu}g$/$m^3$ with mechanical ventilation. They were also observed with agitation to 208.7${\mu}g$/$m^3$ and 139.8${\mu}g$/$m^3$ with natural ventilation, and 209.2${\mu}g$/$m^3$ and 131.7${\mu}g$/$m^3$ with mechanical ventilation. Averaged concentrations of total airborne bacteria and fungi in the compost pilot plant without agitation were observed to 28,673cfu/$m^3$ and 22,507cfu/$m^3$ with natural ventilation, and 7,462cfu/$m^3$ and 3,228cfu/$m^3$ with mechanical ventilation. They were also observed with agitation to 19,592cfu/$m^3$ and 26,376cfu/$m^3$ with the natural ventilation, and 18,645cfu/$m^3$ and 24,581cfu/$m^3$ with the mechanical ventilation. It showed that the emission rates of gaseous pollutants, such as ammonia, hydrogen sulfide, and odor concentration, in the compost pilot plant operated with the mechanical ventilation and with the agitation of compost pile were higher than those with the natural ventilation and without the agitation. While the concentrations of inhalable dust and total airborne bacteria in the compost pilot plant with the natural ventilation and with the agitation, the concentrations of respirable dust and total airborne fungi in the compost pilot plant with the mechanical ventilation and agitation were higher than those with the natural ventilation and without the agitation of compost pile. It was statistically proved that indoor temperature and relative humidity affected the release of particulates and biological pollutants, and ammonia and hydrogen sulfide were believed primary malodorous compounds emitted from the compost pilot plant.

NO Reduction Performance of V2O5-WO3/TiO2 Catalyst Supported on a Ceramic Sheet Filter (세라믹 시트 필터에 부착된 V2O5-WO3/TiO2 촉매의 NO 환원 성능)

  • Choi, Joo Hong
    • Clean Technology
    • /
    • v.24 no.1
    • /
    • pp.27-34
    • /
    • 2018
  • Catalytic filter has many advantages for the industrial application owing to its bi-functional ability to treat nitrogen oxides and particulate simultaneously. The technical feasibility of using the catalytic filter in the flue gas treatment process will be more promoted if the high porous ceramic sheet filter is utilized. However, it is not easy to prepare the effective catalytic filter using sheet filter as it has less room for catalyst support due to its thin layer. In this study, catalytic filter using a domestic ceramic sheet filter element has been prepared and conducted the experimental evaluation for NO reduction performance. The current sheet filter element shows the low catalytic activity less than 92% conversion for NO concentration 700 ppm at the face velocity $0.02m\;s^{-1}$. This unexpected low catalytic activity seems to be caused by the present of extraordinary large pores from the lack of uniformity in the pore size distribution of the sheet filter. The large pore size of the sheet filter is reduced by composing the smaller powder as its raw material, which presents improvement in NO conversion more than 96%. More improvement is observed showing 98% NO conversion which is applicable to a commercial plant when the catalyst coating layer is expanded by adding the large $TiO_2$ particles during the catalyst preparation. Both of above two methods is regarded as that the broad gates of the larger pores in the coating layer are effectively filled with the proper catalyst. So these results encourage the utilization of sheet filter as a good catalytic filter material with its potential merit of high permeability.

A Study of Alkali Metal Vapor Adsorption Behavior by Using Pressurized Reactor (가압반응기를 이용한 알칼리금속증기 흡착특성에 관한 연구)

  • 전수한;최병철;김형택
    • Journal of Energy Engineering
    • /
    • v.11 no.2
    • /
    • pp.114-121
    • /
    • 2002
  • Alkali metal compounds existed in original coal or sorbents are exhausted as vapor or small particle at the outlet of combustor when operating PFBC power plant. These compounds can be removed with dust removal equipment, but total generation efficiency will be decreased because of lower operating temperature of dust removal equipment. Alkali metal contained in vapor phase is initially deposited onto turbine blade results in serious corrosion. The concentration of alkali vapor in the PFBC flue gas is 20∼40 ppm which is dependent on mineral characteristics and composition as well as operating condition of PFBC. However, the allowance limit of alkali metal vapor is assigned as less than 50 ppb for gas turbine when coal or oil is used as fuel. Therefore, alkali metal vapor in PFBC or IGCC process should be removed by solid sorbents to prevent corrosion of turbine blade and improve plant efficiency. In the present investigation, powder of Bauxite, Kaolinite and Limestone is used in the preparation of cylinder-type pellet which is inserted into the pressurized alkali removal reactor for the alkali absorption experiment. Experimental results showed that the alkali removal efficiency in the order of Bauxite, Kaolinite and Limestone. Alkali vapor removal efficiency is related with reaction temperature, porosity of pellet and alkali vapor concentration of flue gas.

Particle Size-Related Dust and Quartz Concentration of Stone Grinding Operations (석재가공 공정에서 발생되는 분진과 석영의 입자크기별 농도 특성)

  • Kim, Seong-Hwan;Bae, Hye Jeong;Jung, Jong-Hyon;Phee, Young Gyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.462-470
    • /
    • 2014
  • Objectives: The purpose of this study was to evaluate quartz concentrations in airborne respirable dust and particle size-related quartz concentrations. Methods: Respirable dust samples were collected using a 10 mm Dorr-Oliver nylon cyclone equipped with a 37 mm, $5{\mu}m$ pore size PVC filter. Dust samples were collected with a Marple's personal cascade impactor from stone grinding operations in five stone-related business located in the Gyeongsangbuk-do area. Results: The geometric mean of quartz concentration in the respirable dust was $0.170mg/m^3$, and the rate of exceeding the Korean Occupational Exposure Limit(KOEL) was 93.3%. The quartz concentration by particle size shows that it was the highest($0.115mg/m^3$) in stage 5($3.50-6.00{\mu}m$), which corresponds with the size of respirable particle. The smaller the particle sizes were, the higher quartz the content became. The mass fractions of inhalable, thoracic, and respirable dust were 72.1%, 36.0%, and 14.4%. Conclusions: The rate of the quartz concentration in respirable dust from stone grinding operations exceeding the American Conference of Governmental Industrial Hygienists Threshold Limit Values was 100%, which means proper work environmental management is required through regular working environmental measurements. Given that the stone grinding operations had a higher small size dust concentrations, there is a need to reduce respirable dust, such as through wet operation and local exhaust ventilation.

A Study on Optimization of Catalyst Injection Controller for Reducing Soot (Soot 저감을 위한 촉매 분사 최적화 방안 연구)

  • Kim Byeong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.3
    • /
    • pp.278-284
    • /
    • 2006
  • The popularity of the diesel engine revolves around its fuel efficiency, reliability, and durability compared to the gasoline engine. However, the main disadvantage of diesel engine is the emission of particulate matter (PM) which is known as carcinogenic substance. Therefore recent progress in engine management and after-treatment systems has led to great improvement to satisfy strict emission regulations. To comply with powerful environment regulations, this study is focused on the decrease of PM(soot) as to increase significantly exhaust temperature. Therefore, HC injection is used as the method to go to the PM regeneration temperature in front of filters composed of diesel oxidation catalyst(DOC) and diesel particulate filter(DPF). And especially, LPG is used because it has good chemical reactions with exhaust. In this study, we could manufacture the test bench thought LPG injection - with which soot can be decreased-, construct 3 kinds of database(DB) according to quantity of temperature to decide the LPG injection quantity and develop DPF ECU algorithm.

  • PDF

The metallic composition of airborne particles in seven locations of Seoul city, Korea (대기 분진 중 중금속 성분의 공간적 농도분포 특성 비교: 서울시 7개 관측점을 중심으로)

  • Choi, Bae-Jin;Kim, Ki-Hyun
    • Analytical Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.143-151
    • /
    • 2003
  • In the present study, we made measurements of PM-bound metal concentrations from seven different urbanized locations in Seoul for the period covering March 2001 through May 2002. The measurement data were analyzed to explore the possible influences of spatial factors on metal distribution characteristics. To check for the importance of such aspects on metal distribution characteristics, the measured data were compared between different metals and between different sites by several criteria including (1) coefficient of variation (CV) values; (2) temporal variability; and (3) the abundance of strongly correlated pairs. The overall results of our study indicate strong diversity in the distribution characteristics of different metals. It is found that some metals (like Fe, Mn, and Pb) tend to exhibit strong compatibility among different study sites. However, no such compatibility appears to exist for certain metals like Cu. To account for the importance of spatial factors, complex relationships between source/sink processes and geochemical characteristics of a given metallic component may have to be examined in a systematic manner.

Concentration of Particulate Nitrate Classified by Formation Mechanism in Seoul Ambient Air (생성메카니즘에 따른 부유분진 등 입자상 nitrate 농도)

  • 천만영;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.1
    • /
    • pp.37-44
    • /
    • 1995
  • Concentration of particulate nitrate classified by formation mechanism and particle diameter in ambient air was determined from Feb. to Oct. 1993. Sampling was carried out using a two-stage Andersen air sampler at the top of a five-story building located at Kon-Kuk University in seoul. Concentration of N $H_{4}$N $O_{3}$ in TSP was measured by pyrolysis of sample filters at 160.deg.C for 1hr. concentration of N $H_{4}$N $O_{3}$ was higher in winter time compared with that in summmer time. Also, concentration of N $H_{4}$N $O_{3}$ was higher in fine particles compared with that in coarse particle. The range of N $H_{4}$N $O_{3}$ concentration was between 2.9 and 9.9.mu.g/ $m^{3}$. Weight fraction of N $H_{4}$N $O_{3}$ in total particulate nitrate was 31.1 .sim. 59.5%, and weight fraction of N $H_{4}$N $O_{3}$ in TSP was 2.1 .sim. 11.2%. Concentration of NaN $O_{3}$, which originated from sea salt, was highest in spring time and lowest in summer time,and the concentration range was between 0.1 and 0.7.mu.g/ $m^{3}$. NaN $O_{3}$/TSP ratio was very low (0.1 .sim. 0.4%) indicating that the portion of NaN $O_{3}$in TSP was negligible. Concentration of particulate nitrate originated from soil was 2.4 .sim. 2.9.mu.g/ $m^{3}$. Weight fraction of that in total particulate nitrate was 14.0 .sim. 37.1%.

  • PDF