• Title/Summary/Keyword: 분압기

Search Result 150, Processing Time 0.024 seconds

Experimental Analysis on Temperature Compensation of Capacitive Voltage Divider for a Pulsed High Voltage Measurement (고전압 펄스신호 측정용 분압기의 온도보상에 관한 실험)

  • Jang, S.D.;Son, Y.G.;Kwon, S.J.;Oh, J.S.;Cho, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1530-1533
    • /
    • 2005
  • Total 12 units of high power klystron-modulator systems as microwave source is under operation for 2.5-GeV electron linear accelerator in Pohang Light Source(PLS) linac. RF power and beam power of klystron are precisely measured for the effective control of electron beam. A precise measurement and measurement equipment with good response characteristics are required for this. Input power of klystron is calculated from the applied voltage and the current on its cathode. Tiny measurement error severely effects RF output power value of klystron. Therefore, special care is needed to measure precise beam voltage. Capacitive voltage divider(CVD) unit is intended for the measurement of beam voltage of 400 kV generated from the pulsed klystron-modulator system. Main parameter to determine the standard capacitance in the high arm of CVD is dielectric constant of insulation oil. Therefore CVD should be designed to have a minimum capacitance variation due to voltage, frequency and temperature in the measurement range. This paper will discuss the analysis of capacitive voltage divider for a pulsed high-voltage measurement, and the empirical relations between capacitance and oil temperature variation.

  • PDF

산소조건 및 배양액이 돼지체외수정란의 체외발달에 미치는 영향

  • 한만희;구덕본;강용국;한용만;이경광;이규승
    • Proceedings of the KSAR Conference
    • /
    • 2002.06a
    • /
    • pp.47-47
    • /
    • 2002
  • Porcine zygotes medium(PZM) 은 5%의 산소조건에서 체내생산 된 돼지초기수정란의 배 발달을 증가시킨다고 보고되었다 (Yoshioka 등, Biol. Reprod., 66:112-119, 2002). 본 실험에서는 NCSU23, PZM3 및 PZM4 의 배양액과 5% 및 20%의 산소조건이 돼지 체외수정란의 배 반포기까지 체외발달에 미치는 영향에 관하여 조사하였다. (중략)

  • PDF

고전압 측정기술

  • 길경석;이복희;하성철
    • 전기의세계
    • /
    • v.46 no.8
    • /
    • pp.41-46
    • /
    • 1997
  • 최근 가스절연변전소와 같은 컴팩트화된 전력설비의 사용으로 과도전압 및 충격전류의 측정시 오차를 유발시키고 장해를 가져오는 요인 중에서 가장 현저한 것은 전자계 현상이며, 이에 대한 대책과 장해의 제거방법이 검토되어야만 한다. 또한 전력기기의 사용 중에 발생되는 과도전압과 충격전류는 진행파로서 작용하여 발생지점과 측정위치에 따라 달라지므로 종래의 저항분압기, 용량성분압기로는 정확한 측정이 불가능하기 때문에 전기적 신호의 과도적 현상을 직접 감지할 수 있는 측정장치가 필요하다. 다음의 3가지 고전압 측정기술은 피측정대상에 따라 가장 적합하게 제안된 것으로 측정응답을 개선하고 전자계의 영향을 최소화함으로써 정확한 측정이 가능하다.

  • PDF

A Study on the Development of Vapor Phase Cleaning Equipment for Semiconductor Processing (반도체 공정에서의 기상 세정장비 개발에 관한 연구)

  • 박헌휘;이춘수;최승우;함승주
    • Proceedings of the KAIS Fall Conference
    • /
    • 2001.05a
    • /
    • pp.79-81
    • /
    • 2001
  • 저압 기상 영역에서 Anhydrous HF 가스와 Methanol vapor를 사용하는 산화막 식각공정을 수행하기 위하여 (1) 반응기 부피의 최소화, (B) 공정압력의 최소화, (3) 고순도 알루미나 Reactor 적용, (4) Cluster화의 개념을 적용한 VPC 장치를 제작하였다. Wafer의 온도, HF의 분압 및 Working Pressure 등의 공정변수에 따른 Oxide Wafer의 식각특성의 변화를 확인하였다. 또한 Etch Uniformity를 향상시키기 위하여 Shower Head 구조를 변경시켜서 실험하였으며, CFD Simulation을 이용하여 Reactor내에서의 HF gas 및 Methanol vapor의 분율을 예측하였다.

Real-time Monitoring of Environmental Properties at Seaweed Farm and a Simple Model for CO2 Budget (해조양식장 수질환경 모니터링을 통한 이산화탄소 단순 수지모델)

  • Shim, Jeong Hee;Kang, Dong-Jin;Han, In Sung;Kwon, Jung No;Lee, Yong-Hwa
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.17 no.4
    • /
    • pp.243-251
    • /
    • 2012
  • Real-time monitoring for environmental factors(temperature, salinity, chlorophyll, etc.) and carbonate components( pH and $fCO_2$) was conducted during 5-6th of July, 2012 at a seaweeds farm in Gijang, Busan. Surface temperature and salinity were ranged from $12.5{\sim}17.6^{\circ}C$ and 33.7~34.0, respectively, with highly daily and inter-daily variations due to tide, light frequency(day and night) and currents. Surface $fCO_2$ and pH showed a range of $381{\sim}402{\mu}atm$ and 8.03~8.15, and chlorophyll-a concentration in surface seawater ranged 0.8~5.8 ${\mu}g\;L^{-1}$. Environmental and carbonate factors showed the highest/lowest values around 5 pm of 5th July when the lowest tidal height and strongest thermocline in the water column, suggesting that biological production resulted in decrease of $CO_2$ and increase of pH in the seaweed farm. Processes affecting the surface $fCO_2$ distribution were evaluated using a simple budget model. In day time, biological productions by phytoplankton and macro algae are the main factors for $CO_2$ drawdown and counteracted the amount of $CO_2$ increase by temperature and air-sea exchange. The model values were a little higher than observed values in night time due to the over-estimation of physical mixing. The model suggested that algal production accounted about 14-40% of total $CO_2$ variation in seaweed farm.

Interpretation of Blood Gas Analysis During Hypothermic Cardiopulmonary Bypass (저체온 체외순환시 혈액가스분석의 판독과 체온과의 상관관계)

  • Song, Sun-Ok
    • Journal of Yeungnam Medical Science
    • /
    • v.6 no.1
    • /
    • pp.121-131
    • /
    • 1989
  • The temperature-corrected values of blood gas analysis were compared to uncorrected values in 40 cases of open heart surgery under moderate hypothermic cardiopulmonary bypass. The results were as follows. 1. The corrected value of pH was significantly higher than uncorrected value, and it's relationship was ${\Delta}pH=-0.015$ ${\Delta}Temp+0.005$(r=0.81, P<(0.01). 2. The corrected value of $PCO_2$ was lower than uncorrected value, and it's relationship was ${\Delta}PCO_2=1.11$ ${\Delta}Temp+1.81$(r=0.50, P<0.01). 3. The corrected value of $PO_2$ was lower than uncorrected value, and it' s relationship was ${\Delta}PO_2=5.21$ ${\Delta}Temp-1.45$(r=0.32, P<0.01). But there was no clinical significance. 4. The corrected values of $HCO_{3^-}$, base excess, $CO_2$ content and oxygen saturation were similar with uncorrected values. In summery, the values of pH and $PCO_2$were significantly changed by temperature-correction. Because of the neutral point of water (pH=pOH) rises as temperature falls and it change in parallel with the changes in blood pH, a corrected pH of 7.4, $PaCO_2$ of 40mmHg during deep hypothermia would reflect a profound respiratory acidosis. Therefore, the use of the uncorrected value at $37^{\circ}C$ is more preferable and valid means of assessing acid-base management regardless of actual patient temperature.

  • PDF

Simulation for Membrane Reactor using Heteropoly Acid Catalyst (헤테로폴리산 촉매를 이용한 고분자막반응기 모사)

  • 최준선;김용헌;이화영
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.53-60
    • /
    • 1997
  • 1. 서론 : 촉매막기술은 반응과 분리공정을 동시에 하나의 장치에서 수행할 수 있기 때문에 한 개의 공정을 줄일 수 있는 효과적인 에너지 절약형 기술이다. 생성물중의 적어도 하나가 선택적으로 막을 통해 투과되기 때문에 가역반응의 경우에는 비가역반응에 가까운 거동을 보이게 된다[1-5]. 본 연구는 12-텅스토인산($H_3PW_{12}O_{40}$)를 촉매로 사용하고 막반응시를 비활성촉매막반응기(IMRCF, Inert membrane reactor with catalyst in the feed side)형태, 막으로는 PSF(Polysulfone), PPO(Polyphenylene Oxide)를 사용하여 MTBE(Methyl tert-butyl ether)분해반응을 모사하였다. 막반응기에서 생성된 생성물을 선택적으로 분리해냄으로 인하여 전환율은 고정층보다 증가하였는데 반응온도가 증가할수록, 반응물의 분압은 낮을수록 증가하였다. 반응온도가 높아짐에 따라 막반응기에서의 전환율은 고정층반응에서 나타나는 전환율과의 차이가 줄어드는 것을 볼 수 있었다. 위와같은 결과에 따라서 MTBE 반응물의 분해로 생성되는Isobutene의 수율이 90$\circ$C 이상의 반응온도에서 촉매/반응물비에 대한 최적조건이 나타나는 것을 알 수 있었다.

  • PDF

A Study on the Development of Digital CT/VD for GIS (가스절연개폐장치(GIS)용 디지털 CT/VD 개발에 관한 연구)

  • Kim, M.S.;Kim, J.B.;Song, W.P.;Kim, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.22-24
    • /
    • 2002
  • 지금까지 변전소나 개폐소에서 전류, 전압을 계측하는 수단으로서 주로 철심과 권선으로 구성되어진 변류기(CT), 계기용 변압기(PT, PD)가 사용되어져 왔다. 최근, 2차측의 계측기나 보호 Relay의 Digital화가 진전되어, 또한 이것을 Digital Network으로 총합한 Intelligent 변전소의 구축이 검토되어짐에 따라, Digital Network에 대응한 신형 CT, VD가 요구되어지고 있다. 상기와 같은 요구로 인해 당사에서는 CT는 검출부에 Rogowski Coil을 적용하며 그 후단에 적분기를 설치하였으며, VD는 검출부에 중간 전극을 이용해서 분압하는 방식인 Capacitive Voltage Divider를 사용하고 증폭기를 삽입하여, 각각 요구되는 전압 신호를 얻었다. 이러한 신형 CT/VD의 적용으로 종래의 CT/PT가 차지하는 공간이 필요 없게 되어 컴팩트한 GIS의 구조가 가능하게 되어 있다.

  • PDF

The Effects of Hypercapnia and High Flow on Cerebral Metabolism During Cardiopulmonary Bypass (심폐바이패스 시 고탄산분압과 고관류법이 뇌대사에 미치는 영향)

  • 강도균;최석철;윤영철;최국렬;정신현;황윤호;조광현
    • Journal of Chest Surgery
    • /
    • v.36 no.7
    • /
    • pp.472-482
    • /
    • 2003
  • Recent studies have demonstrated that cerebral desaturation during rewarming period of CPB was associated with postoperative neurologic dysfunction. The prevention of cerebral desaturation during CPB may reduce the incidences of neurologic and neuropsychological complications. The present study was prospectively undertaken to compare the clinical effects between two strategies (hypercapnic CPB and high flow CPB) to prevent cerebral desaturation for establishing a proper CPB technique. Material and Method: Thirty-six adult patients scheduled for elective cardiac surgery were randomized into either hypercapnic (Pa$CO_2$ 45~50mmHg, n=18) or high flow group (flow rate 2.75 L/ $m^2$/min and Pa$CO_2$ 35~40mmHg, n=18) during rewarming period of CPB. In each patient, middle cerebral artery blood flow velocity ( $V_{MCA}$), cerebral arteriovenous oxygen content difference (C(a-v) $O_2$), modified cerebral metabolic rate for oxygen (MCMR $O_2$), cerebral oxygen transport rate ( $T_{E}$ $O_2$), incidence of cerebral desaturation (internal jugular bulb blood oxygen saturation $\leq$ 50%), increased rate of S-100 $\beta$ concentration, and arterial and internal jugular bulb blood gas were measured during the five phases of the operation; Pre-CPB, CPB-10 min (steady-state CPB, nasopharyngeal temperature 29~3$0^{\circ}C$), Rewarm-1 (rewarming phase, nasopharyngeal temperature 33$^{\circ}C$), Rewarm-2 (nasopharyngeal temperature 37$^{\circ}C$), and CPB-off. Incidence of postoperative delirium and duration were assessed in all patients. All variables were compared between the two groups. Result: $V_{MCA}$ (157.88$\pm$10.87 vs 120.00$\pm$6.18%, p=0.006), internal jugular bulb $O_2$ saturation (68.01$\pm$2.75 vs 61.28$\pm$2.87%, p=0.03) and $O_2$ tension (41.01$\pm$2.25 vs 32.02$\pm$ 1,67 mmHg, p=0.03), and $T_{E}$ $O_2$(110.84$\pm$7.41 vs 81.15$\pm$8.11%, p=0.003) at rewarming periods were higher in the hypercapnic group than in the high flow group. C(a-v) $O_2$ (4.0$\pm$0.30 vs 4.84$\pm$0.38 mg/dL, p=0.04), COE (0.36$\pm$0.03 vs 0.42$\pm$0.03, p=0.04), increased rate of S- 100$\beta$ (391.67$\pm$23.40 vs 940.0$\pm$17.02%, p=0.003), and incidence of cerebral desaturation (2 vs 4 patients, p=0.04) at rewarming periods, and duration of postoperative delirium (18 vs 34 hr, p=0.02) were low in the hypercapnic group compared to the high flow group. Conclusion: These results indicate that hypercapnic CPB may provide relatively diminished cerebral injury and beneficial effects for cerebral metabolism relatively compared to high flow CPB.low CPB.

Evaluation of Errors of Electronic Voltage Transformer using High Voltage Capacitance Bridge and Standard Capacitive divider (고전압 전기용량 브지리와 표준용량분압기를 이용한 전자식 전압변성기의 평가)

  • Han, Sang-Gil;Kim, Yoon-Hyoung;Jung, Jae-Kap;Kang, Jeon-Hong;Lee, Sang-Hwa;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.61-63
    • /
    • 2008
  • We established a system to evaluate the ratio error and phase angle error of electronic voltage transformer using high voltage capacitance bridge and standard capacitors. The uncertainty of evaluation system is about 0.005% in ratio error and 1.5 min in phase angel error.

  • PDF