• Title/Summary/Keyword: 분석검출한계

Search Result 1,065, Processing Time 0.027 seconds

Algorithm Development and Experimental Verification of Acoustic Emission First-arrival-time Determination for the Source Location (정확한 미소파괴음의 발생위치 분석을 위한 신호 도달시간 결정 알고리즘 연구 및 실험적 검증)

  • Jang, Hyun-Sic;Choi, Jun-Young;Jang, Bo-An
    • The Journal of Engineering Geology
    • /
    • v.25 no.4
    • /
    • pp.587-598
    • /
    • 2015
  • We examined various existing threshold methods for the determination of the first arrival time of acoustic emission (AE), and developed a new variable threshold method that could determine the first arrival time of AE more accurately and more quickly than existing methods. The new method, a modification of an existing threshold method, does not fix the threshold, but applies variable thresholds for the AE signals according to noise analysis. Two- and three-dimensional models were established to test the effectiveness of the new method. It could determine source locations of AE in a two-dimensional model 38.3% more accurately than the pre-existing threshold methods. Its accuracy improvement over the existing methods in a three-dimensional model was about 15.2%. A practical test involved measuring the source locations of AE during three-point bending tests of granite cores. The new method placed the sources closer to the fracture plane than did the pre-existing methods, indicating its superior (and quicker) ability to determine the source locations of AE.

Determination of Minimum Detectable Activity in Environmental Samples (환경방사능 측정에서의 검출한계치의 정량적 고찰 및 최소검출방사능 농도 계산)

  • Lee, Myung-Ho;Shin, Hyun-Sang;Hong, Kwang-Hee;Cho, Young-Hyun;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.3
    • /
    • pp.171-184
    • /
    • 1999
  • In this paper, using statistical theory the basic concepts and the formulars of lower limit of detection were deasribed. Assuming that risks of 5% are acceptable (95% confidence level), lower limits of detection were calculated on the measuring apparatus for alpha, beta and gamma nuclides. Also, on the basis concepts of lower limit of detection, the MDA values were calculated for the radionuclides detected easily in the environment. These results make it possible to evaluate confidence limits on the radioanalytical results in the environmental sample.

  • PDF

Gas Chromatographic Performances for Simultaneous Determination of Multi-pesticide Residues and Extraction of Pesticides with Three Partition Solvents (잔류농약 다성분 동시분석을 위한 기체 크로마토그래피 분석성능과 3종 분배용매에 의한 농약추출)

  • Kim, Chan-Sub;Kim, Jin-Bae;Im, Geon-Jae;Park, Hyun-Ju;Lee, Young-Deuk
    • The Korean Journal of Pesticide Science
    • /
    • v.13 no.3
    • /
    • pp.133-147
    • /
    • 2009
  • In order to develop the simultaneous analytical method for pesticide residues which ones in soil are rapidly and inexpensively measured by, many analytical methods for individual pesticide residue and several methods for multi-pesticide residues in agricultural commodities and food were reviewed. Various gas chromatographic conditions and pre-treatment procedures were intensively investigated and modified. And then new optimum procedure was established and its proficiency was validated. The response on detectors of simultaneous determination of 180 pesticides out of pesticides used in Korea was tested. The number of pesticides that their limits of detection (LOD) equal or lower than $0.05\;mg\;kg^{-1}$ were 137 pesticides on ECD, 170 pesticides on NPD and 179 pesticides on ECD/NPD integrated. The retention times of most pesticides ranged appropriately between 10 minutes and 40 minutes in the proposed chromatographic conditions. But about 90 pesticides eluded between 20 minutes and 30 minutes and so they were not resolved enough. In partition with dichloromethane, ethyl acetate/hexane (1:1) and ethyl acetate, number of pesticides whose extraction efficiency ranged from 70% to 120%, were 163, 154 and 147, respectively.

글로우방전을 이용한 생체시료 중 극미량성분분석에 관한 연구

  • 김효진
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1994.04a
    • /
    • pp.275-275
    • /
    • 1994
  • 생체시료 중 극미량성분분석에 관한 필요성이 높아지고 있으며 기존의 분석기기를 사용하여 분석방법을 개발하는 연구나 새로운 분석기기를 개발하는 연구들을 통하여 이들 물질들을 분석하고자 하고있다. 특히 극미량성분인 경우 생체내에 수십 Pg이 존재하면서 이들의 농도변화가 생리활성에 변화를 주기 때문에 검출한계가 낮은 검출기가 필요하게되며 또한 생체시료중의 여러물질들로 인하여 이들을 분리하는 크로마토그라피기술과 이들이 분리된 후 실제로 어떠한 물질인지를 확인할 수 있는 즉 정성까지 가능한 검출기의 개발이 요구되고 있다.

  • PDF

Analysis of gibberellic acid from fruits using HPLC/UV-vis (HPLC/UV-vis을 이용한 과일류 중의 지베렐린 산 분석)

  • Ma, Kyung Na;Cho, Hyun-Woo;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.19-26
    • /
    • 2013
  • Gibberllic acid ($GA_3$) is one of gibberellins (GAs) that are a class of plant growth hormones that exert profound and diverse effects on plant growth and development. $GA_3$ is essentially non-UV absorbing and is difficult to assay by UV-detector. For effective extraction of gibberellic acid from fruits by using liquid-liquid extraction, optimized pH and extraction solvent were established. The selective and sensitive derivative of $GA_3$ for HPLC/UV-vis was derivatized using phenacyl bromide, and the experimental factors, including reaction time, reaction temperature and amount of derivatizing reagent and base were investigated for the effective synthesis. The derivatized $GA_3$ with phenacyl bromide was effectively analyzed by HPLC/UV-vis. The structure of derivatized $GA_3$ was confirmed by HPLC/ESI-MS. For apple, LOD and LOQ were 0.008 mg/kg and 0.027 mg/kg, respectively. For pear, LOD and LOQ were 0.003 mg/kg, 0.012 mg/kg, respectively. The established method can be applied to more effective analysis of $GA_3$ from plant and food.

Characterization of Atomic Emission Detector for Gas Chromatography Using Cylindrical Microwave Cavity (원통형 Microwave Cavity를 이용한 기체크로마토그라프 원자발광 검출기의 특성에 관한 연구)

  • Park, Young-Joo;Yoo, Hee-Soo
    • Analytical Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.263-268
    • /
    • 1992
  • A plasma source with cylindrical microwave cavity was used as atomic emission detector for gas chromatography. Detection limits of several elements were determined for this system. Detection limits for bromine and sulfur were 0.46 pg/s and 0.51 ng/s, respectively. The plasma was stable at the range of flow rate of 10 to 20mL/min.

  • PDF

Optimal HPLC Condition for Simultaneous Determination of Anthocyanins in Black Soybean Seed Coats (검정콩 함유 안토시아닌의 동시분석을 위한 최적 HPLC 분석 조건)

  • Choung, Myoung-Gun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.4
    • /
    • pp.359-368
    • /
    • 2008
  • Black soybean has been widely utilized as foods and oriental medicinal materials. The pigmentation in the seed coat of black soybean is due to accumulate anthocyanins in the epidermis palisade layer. The anthocyanins of black soybean seed coat are considered as a parameter of quality evaluation of black soybean. Therefore, the purpose of this study was to investigate the most suitable HPLC condition for simultaneous determination of anthocyanins in black soybean seed coats extracts. The efficient HPLC analytical condition of D3G, C3G, and Pt3G contained extracts of black soybean seed coats was developed. The gradient elution employed a $250\;mm\;{\times}\;4.6\;mm$ i.d. YMC-pak ODS-AM 303 column. The gradient system was used two mobile phases. A gradient elution was performed with mobile phase A, consisting of 5% aqueous formic acid, and mobile phase B, comprising 5% formic acid - acetonitrile, and delivered at a flow rate of 0.7 mL/min as follows: $0{\sim}35\;min$, $90%\;A{\sim}60%\;A$; 36 min, 90% A; 46 min, 90% A. The UV-VIS. detection wavelength was set at 520 nm. The limit of detection (LOD) for D3G, C3G, and Pt3G were under 10 ng/mL.

Development of Prototype Liquid Scintillator System for Monitoring Liquid Radioactive Waste (배수 모니터링 액체섬광검출시스템의 프로토 타입 개발)

  • Nam, Uk-Won;Seon, Kwang-Il;Kong, Kyoung-Nam;Kim, Chang-Kyu;Lee, Dong-Myung;Lee, Sang-Kook
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.173-182
    • /
    • 2003
  • A prototype liquid scillatillator system for measurement of multiple beta-labeled mixtures was developed and its characteristic was investigated. The signal processing system consists of two photomultiplier tubes and the coincident count circuit. The characteristic of the system was analyzed using 4 beta-labeled samples $(^3H,\;^{14}C,\;^{36}Cl\;and\;^{90}Sr)$. Beta spectra from the samples were obtained without radiation shielding, and the detection limits for each nuclides were estimated based on the spectra. The estimated detection limits were compared to the legal regulation values. It is found that the liquid radioactive nuclides are detectable well below the legal regulation values.