• 제목/요약/키워드: 분산전원

검색결과 676건 처리시간 0.035초

Adaptive Over Current Relay for power systems having Decentralized Generator (분산전원용 적응형 과전류 계전기)

  • Kim, Hyung-Kyu;Song, Hwang-Bin;Ahn, Jong-Pil;Jeong, Cheal-Hyun;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.195-196
    • /
    • 2008
  • Output of wind generators are changed by windy level. The change of the output also affects the amplitude of fault current. And this fault current causes OCR's mal-operation. To solve the problem, this paper adopts that Over Current Relay adapted for Decentralized generator algorithm.

  • PDF

A Study on the Technology Tree Model of Power IT Integration Operation System on the Real Grid (실 전력계통에서의 전력IT 통합운영시스템 구축 기술체계 모형에 관한 연구)

  • Hwang, Woo-Hyun;Kim, Ja-Hee
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.31-33
    • /
    • 2008
  • 산업사회에서의 전력공급 계통은 설비고장이 발생할 경우 해당지역에 국한되어 정전이 발생하기 때문에 피해가 확산되거나 사회적인 이슈가 되지는 않았다. 광케이블을 이용한 정보통신사회가 구축되어 금융과 언론을 비롯한 대부분의 생활이 인터넷을 중심으로 진행되고 있고 향후 지식기반 사회로의 진전이 급속히 진전될 것에 대비하여 전력계통 설비와 운영 방법의 고도화가 필요하게 되었다. 전력IT는 현재의 전력설비와 네트워크, IT를 이용하여 더욱 심층적인 연구가 진행되고 있으며 본 논문에서는 전력IT 연구과제 결과물의 활용성을 높이고 기술개발 과정에서의 시행착오를 최소화하기 위해 총 10개 과제를 하나로 운영할 경우를 상정하여 연구에 필요한 기술체계 모형을 개발하였고 이 모형을 토대로 향후 분산형 전원을 포함한 전력계통의 최적운영과 고장예측기법을 이용한 설비관리로 정전을 예방하여 최고품질의 전력을 공급하는데 기여하고자 하였다. 이 논문은 전력IT의 도입배경과 현재까지의 연구 성과분석을 토대로 실 계통 검증 5단계와 기술체계 모형 그리고 통합운영시스템 개념도 제시 순으로 작성하였다.

  • PDF

A Study on Development Model for the Plan of Long and Mid Term Distributed Generation(I) (중.장기 분산전원계획 수립용 모델연구(I))

  • Kim, Yong-Ha;Woo, Sung-Min;Yeon, Jun-Hee;Oh, Seok-Hyeon;You, Jung-Huy
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.496-497
    • /
    • 2008
  • This paper presents development of the long and mid term power expansion planing for distributed generation. This planing model reflect WADE Economic Model's advantage that special quality of DG(Decentralized Generation) and WASP Model's advantage that special quality of CG(Centralized Generation) each other. Through these synergy, we develop better the Plan of Long and Mid Term Distributed Generation then existent model.

  • PDF

Study on electric equipment design for solution about Hapcheon No.2 Hydropower capacity increase and consequential grid-connection problem (합천 제2수력 발전기 용량증대에 따른 계통연계범위 이탈문제 해결을 위한 설비설계 방안 고찰)

  • Jeong, Hyo-Geun;Kim, Woo-Yong;Kang, Dong-Hyung;Choi, Hong-Yeol;Ham, Dong-Young;Jeong, Jun-Gi
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.219-220
    • /
    • 2015
  • 합천 제2수력 수차발전기 용량증대사업($1,200{\rightarrow}1,800kW$)에 따른 실시설계 시 계통연계 가능여부를 한전으로부터 확인한 결과, 해당 배전선로에 기 연계된 분산형전원에 의해 전압 상한치를 이미 상당히 초과하여 연계 불가한 것으로 회신받음에 따라 계통연계범위 이탈문제 해결 및 해당 배전선로 연계를 위한 위한 설비설계 방안을 고찰하였다.

  • PDF

A study on the role and performance characteristic of the condenser of induction generator at hydero power (소수력 유도발전기의 콘덴서 역할 및 동작 특성에 관한 고찰)

  • Im, Ji-Yeon;Lee, Jin-Kwon;Chae, Ji-Seog;Hwang, Jin-Yeol;Ok, Yeon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1509-1510
    • /
    • 2015
  • 유도발전기는 구조가 간단하고, 동기발전기처럼 여자장치를 필요로 하지 않기 때문에 소수력발전소에 주로 적용되고 있다. 배전계통에 연계되는 경우가 많은 소수력발전기 특성상 계통의 안정적인 운영을 위하여 한전에서는 분산형전원 배전계통 연계 기술기준에 의거하여 발전기와 병렬로 역률개선용 콘덴서를 설치하도록 하고 있다. 콘덴서 동작에 따른 역률의 이론값과 실제 측정값을 비교하고, 계통 측과 발전기 측의 콘덴서 동작에 따른 역률 개선 효과를 검토하였다.

  • PDF

A Study on the Power Control of Grid-Tied RPG Fuel Cell System (계통연계형 가정용 연료전지 시스템의 전력제어에 관한 연구)

  • Lee J.M.;Jung J.H.;Chung J.M.;Suh I.Y.;Han S.H.
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.263-265
    • /
    • 2006
  • 연료전지를 이용한 가정용 분산전원시스템은 열과 전기를 동시에 얻을 수 있는 장점을 갖는다. 본 논문에서는 PEMFC형 연료전지의 V-I 특성과 이에 따른 계통연계형 가정용 연료전지 시스템의 전력제어 시 고려해야 할 사항을 기술하고 제안된 제어방식에 대해 수행된 시뮬레이션 및 시험결과를 제시하고자 한다.

  • PDF

A Study on Fuel Cell Inverter Operation for Distributed Generation (분산전원용 연료전지 인버터 운전에 관한 연구)

  • Jang S.J.;Lee T.W.;Song S.H.;Kim J.H.;Won C.Y.;Kim Y.H.
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.981-986
    • /
    • 2003
  • Recently, a fuel cell is remarkable for new generation system. The fuel cell generation system converts the chemical energy of a fuel directly into electrical energy. The fuel cell generation is characterized by low voltage and high current. For connecting to utility, it needs both a step up converter and an inverter. The step up converter makes DC link and the inverter changes D.C to A.C. In this paper, full bridge converter and the single phase inverter are designed and installed for fuel cell. Simulation and experiment verify that fuel cell generation system could be applied for the distributed generation.

  • PDF

Fuzzy-GA Application for Allocation and Operation of Dispersed Generation Systems in Composite Distribution Systems (복합배전계통에서 분산형전원의 설치 및 운영을 위한 Fuzzy-GA 응용)

  • 김규호;이유정;이상봉;유석구
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • 제52권10호
    • /
    • pp.584-592
    • /
    • 2003
  • This paper presents a fuzzy-GA method for the allocation and operation of dispersed generator systems(DGs) based on load model in composite distribution systems. Groups of each individual load model consist of residential, industrial, commercial, official and agricultural load. The problem formulation considers an objective to reduce power loss of distribution systems and the constraints such as the number or total capacity of DGs and the deviation of the bus voltage. The main idea of solving fuzzy goal programming is to transform the original objective function and constraints into the equivalent multi-objectives functions with fuzzy sets to evaluate their imprecise nature for the criterion of power loss minimization, the number or total capacity of DGs and the bus voltage deviation, and then solve the problem using genetic algorithm. The method proposed is applied to IEEE 12 bus and 33 bus test systems to demonstrate its effectiveness. .

Study on LVRT Capability of PMSG-Type Wind Turbine under Low Voltage of the Grid (계통 저전압에 대한 PMSG-Type 풍력터빈의 LVRT 기능에 대한 연구)

  • Kang, Shin-Il;Lee, Hyun-Young;Kwon, Oh-Jung;Oh, Sang-Keun;Kim, Soo-Cheol;Ahn, Jong-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.334-338
    • /
    • 2008
  • 현재 세계적으로 풍력터빈의 설치 용량이 점차 증가함에 따라 계통에 연계되는 에너지양 또한 급격하게 증가하였다. 풍력터빈의 크기 및 수가 적었던 예전에는 전형적인 분산형 전원으로서 계통에 소규모 외란이 발생하였을 경우, 풍력터빈은 운전이 정지되었으며 그로 인해 계통에 미치는 영향은 거의 무시될 수 있었다. 하지만 최근에는 계통에 영향을 줄 만큼 풍력발전단지가 증가함에 따라 계통 외란에 대해서 운전을 정지하지 않고 계통에 협조하는 특별한 형태로 그 역할이 변경되고 있다. 그래서 이미 많은 나라에서는 그 나라에 맞는 계통연계규정(Grid Code)을 만들어 풍력터빈들이 계통에 미치는 영향에 대해 재평가가 이루어지고 있으며 이제는 짧은 순간의 계통 외란에서도 풍력터빈은 지속적인 운전을 해야 하는 LVRT 기능을 법제화하고 있는 추세이다.

  • PDF

A Study on the Analytical Approach for Reliability Assessment in Distribution Systems Interconnected with Dispersed Storage and Generation Systems (분산형전원이 도입된 배전계통의 신뢰도평가에 관한 연구)

  • Song, Seok-Hwan;Rho, Dae-Seok;Choi, Jae-Seok;Cha, Jun-Min
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.286-288
    • /
    • 2001
  • This paper deals with the analytical approach for the reliability assessment in radially operated distribution systems. The existing indexes can consider the number and configuration of the load, but can not consider the characteristics of the load which is the one of the most important factor in the investment cost for the distribution systems. Therefore, This paper presents the new indexes considering the expected interruption cost for the load section and protection systems in the cafe where the Dispersed Storage and Generation Systems are introduced to distribution systems. And this paper shows the effectiveness of the proposed methods by simulating at the model systems.

  • PDF