• Title/Summary/Keyword: 분무 중심 길이

Search Result 10, Processing Time 0.028 seconds

Spray Characteristics of Gas-Centered Swirl Coaxial Injectors according to Injection Conditions (분무 조건에 따른 기체 중심 스월 동축형 분사기의 분무 특성)

  • Park, Gujeong;Lee, Jungho;Lee, Ingyu;Yoon, Youngbin
    • Journal of ILASS-Korea
    • /
    • v.19 no.4
    • /
    • pp.167-173
    • /
    • 2014
  • The spray characteristics of Gas-Centered Swirl Coaxial Injector was investigated that there were different characteristics with or without gas flow. As gas flow was accelerated, the momentum of gas was transferred to the momentum of liquid in the low liquid Reynolds number. Therefore, the axial velocity of liquid was increased and the measured value was smaller than without gas flow. However, in the high momentum flux ratio, the momentum transfer hardly occurred and the results had constant values. As the recess length was increased, the mixing area of gas and liquid also was increased, the results were decreased.

A Study on the Disintegration and Spreading Behavior of Fuel-spray Emanating from a Liquid-thruster Injector by Pseudo-3D Spatial Distribution Measurement (준3차원적 공간분포 계측에 의한 액체추력기 인젝터 연료분무의 분열 및 확산 거동에 관한 연구)

  • Kim, Jin-Seok;Kim, Jeong-Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.5
    • /
    • pp.9-17
    • /
    • 2008
  • Pseudo-3D spatial distribution of spray droplets is investigated by using Dual-mode Phase Doppler Anemometry (DPDA) in order to examine the disintegration and spreading behavior of spray exiting from liquid-propellant thruster injector. Spray injected from nozzle orifice with length-to-diameter ratio ($L/d_o$) of 1.67 and under the injection pressure of 27.6 bar is aligned to the vertical. Vertical and horizontal mean velocities of droplets, Sauter Mean Diameter (SMD), and volumetric flux decrease as droplets travel from center/upstream toward outer region/downstream of spray. Although the distribution of spray characteristic parameters is symmetric against the geometric axis of nozzle orifice, their absolute values are asymmetric.

Comparison between GOx/Kerosene and GN2O/Ethanol Reactive Spray in a Subscale Liquid Rocket Engine (축소형 액체로켓엔진에서 기체산소/케로신 및 기체아산화질소/에탄올 연소 분무의 비교)

  • Choi, Songyi;Shin, Bongchul;Lee, Keonwoong;Kim, Dohun;Koo, Jaye;Park, Dong-Kun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.4
    • /
    • pp.61-68
    • /
    • 2015
  • Reactive sprays of two propellant combinations(GOx/kerosene and $GN_2O$/ethanol) were observed and compared with each other as a basic research of visualizing supercritical combustion. A shadowgraph imaging method was used to visualize the reactive sprays, and shadowgraph images were converted to density gradient magnitude images to analyse the structure of reactive sprays. The gas-liquid interface of GOx/kerosene spray showed rougher boundary and steeper density gradient near the injector face than the $N_2O$/ethanol at similar combustion chamber pressure. Spray core length was calculated from averaged density gradient magnitude images and it was revealed that spray core length of GOx/kerosene was shorter than that of $GN_2O$/ethanol, although momentum flux ratio of GOx/kerosene propellant combination was lower.

Disintegration and Spreading Behavior of the Spray emanating from a Liquid-thruster Injector (액체추력기 인젝터로부터 발생하는 분무의 분열 및 확산 거동)

  • Kim, Jin-Seok;Jung, Hun;Kim, Jeong-Soo;Kim, Sung-Cho;Park, Jeong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.113-116
    • /
    • 2008
  • Pseudo-3D Spatial distribution of spray droplets is investigated by using Dual-mode Phase Doppler Anemometry (DPDA) in order to examine the disintegration and spreading behavior of spray exiting from liquid-thruster injector. Spray injected from nozzle orifice with length-to-diameter ratio $(L/d_o)$ of 1.67 and at the injection pressure of 27.6 bar is aligned to the vertical. Vertical and horizontal mean velocities of droplets, Arithmetic Mean Diameter (AMD), Sauter Mean Diameter (SMD), and volumetric flux decrease as droplets travel from center/upstream toward outer region/downstream of spray.

  • PDF

The Effect of Pressure and Hose Length on the Travelling Distance of Particles in Power Sprayer (토출압력(吐出壓力) 및 호오스길이가 도달성(到達性)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Kwon, Soon Hong;Choi, Kyu Hong
    • Journal of Biosystems Engineering
    • /
    • v.7 no.2
    • /
    • pp.30-35
    • /
    • 1983
  • To investigate the factors affecting the transportability of spray droplets, the maximum distance, the effective distance, the ratio of even distribution, and the diameters of particles were measured in accordance with the different pressure levels of power sprayer using 3 hole swath type nozzle, and the results are summerized as follows; 1. The distance of the most dense point from the nozzle was shortened by 0.5 meter with the 100-meter-long hose. The maximum reaching distances were reduced by 1.5 and 1.0 meters for the 13m/m and the 8.5 m/m hoses respectively, and the effective distance were reduced by 0.5 meter for both cases. 2. The effective distance can not be extended beyond 14 meters even if the length of hose is minimized at the rated pump pressure 28 kg/$cm^2$, it was 1 meter longer for 13m/m hose compared to the 8.5m/m one. 3. In case of 13m/m hose, the most dense point can be extended further by 0.5 meter increasing the pump pressure by 8 kg/$cm^2$, and the maximum distance and effective distance were increased by 2.0 and 0.5 meters respectively. There was no significant effect of pressure changes on the transportability in case of 8.5m/m hose. 4. Both the reduction of hose length and the increase of pump pressure influenced in large extent to the atomization effect of droplets. It was noticed that the diameter of droplet is related to the pump pressure and inside diameter of hose. 5. The pressure drop in 100-meter-long and l3m/m hose was 5~7kg/$cm^2$ at the pump pressure range of 25~33kg/$cm^2$, and it is an equivalent of 2% per 10 meter length of hose.

  • PDF

A Study on Diesel Spray and Flame by Rapid Compression Machine (급속압축장치에 의한 디이젤 분무 , 화염의 연구)

  • 안수길
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.19 no.1
    • /
    • pp.40-45
    • /
    • 1983
  • The paper describes an experimental investigation of axisymmetric diesel spray and flame which is held in rapid compression machine (RCM) with electromagnetic single injection nozzle. The axisymmetric diesel spray and flame are taken with high speed photograph and analysis it with image processor. The data presented include fuel concentration of spray, flame temperature, soot concentration of flame in axial and radial direction at a moment and compared it with each other.

  • PDF

Cold flow tests of Gas-centered swirl coaxial injectors (Gas-centered swirl coaxial 분사기의 상압수류시험)

  • Jeon, Jae-Hyoung;Hong, Moon-Geun;Kim, Jong-Gyu;Lee, Soo-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.16-19
    • /
    • 2011
  • An experimental study on the spray characteristics of Gas-centered swirl coaxial injectors(GCSCI) for high-performance staged combustion rocket engines has been carried out using cold flow tests. In this study, water and gaseous nitrogen are used as working fluids and a back-lit photography technique with image processing for the measurements of spray characteristics. Our study is focused on the effect of injector geometries like as gap thickness of liquid nozzle and gas nozzle and momentum flux ratio for fundamental understanding of the injectors.

  • PDF

Theory and practice of synthesized ZnO powders by ultrasonic spray pyrolysis method (초음파 분무 열분해법에 의한 ZnO 합성의 이론과 실제)

  • 서수형;신건철
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.5 no.1
    • /
    • pp.60-66
    • /
    • 1995
  • Abstract The experimental results which is the aerosols behavior and distribution of atomized zinc nitrate ($Zn(NO_3)_2$) solution (0.5 M) by ultrasonic vibrator were in accord with the computer simulations. i.e., most aerosols passing through the reactor (hot zone) moved toward the center of reactor by thermophoresis as the axis of reactor increase. Also, the distribution of aerosols concentration was high at the center of reactor as the axis increase. Among the synthesized ZnO particles, shell-like aggregates of fracture type which could not see at the center of reactor were observed at near the wall of reactor, and the particle size ($ 1.2 {\mu\textrm{m}$) of near the wall was larger than that ($0.9 {\mu\textrm{m}$) of the center.

  • PDF

A Numerical Study on Mixing Characteristics for Recess Length of Swirl Coaxial Injector (스월 동축형 분사기의 리세스 길이에 따른 혼합특성에 관한 수치적 연구)

  • Kim, Young-Jun;Hong, Moon-Geun;Lee, Soo-Yong;Sohn, Chae-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.74-77
    • /
    • 2011
  • A mixing characteristics on recess length change of Gas-centered swirl coaxial injector using high-performance staged combustion rocket engine carry out study through CFD(Computational fluid dynamics). propellant phase that combined gas-liquid simulate gas-gas. In order to measure spreading angle, velocity distribution to injector exit and spray structure of propellant analyzed. Axial velocity increase by increasing recess length, but tangential velocity decrease. The result confirmed qualitative characteristics that the spreading angle decreases.

  • PDF

Analysis of Actual State of Facilities for Pleurotus eryngii Cultivation - Based on Western Gyeongnam Area - (큰느타리버섯 재배사의 실태분석 - 서부경남지역을 중심으로 -)

  • Yoon Yong Cheol;Suh Won Myung;Yu Chan
    • Journal of Bio-Environment Control
    • /
    • v.13 no.4
    • /
    • pp.217-225
    • /
    • 2004
  • This study was performed to provide the basic knowledge about the mushroom cultivation facilities. Classified current status of cultivation facilities in Gyeongnam province was investigated by questionnaire. The structure of Pleurotus eryngii cultivation facilities can be classified into the simple and permanent frame type. The simple frame structures were mostly single-span type, on the other hand, the permanent frame structures were more multi-span than simple structures. And the scale of cultivation facilities was very different regardless of structural type. But as a whole, the length, width and ridge height were prevailing approximately 20.0 m, $6.6\~7.0m$ and $4.6\~5.0m$ range, respectively. The floor area was about $132\~160\;m^2$, and floor was built with concrete to protect mushrooms from various harmful infection. The roof slope of the simple and permanent type showed about $41.5^{\circ}\;and\;18.6\~28.6^{\circ}$, respectively. The width and layer number of growing bed for mushroom cultivation were around $1.2\~1.6m$, 4 layers in common, respectively. Most of year round cultivation facilities were equipped with cooler, heater, humidifier, and ventilating fan. Hot water boiler was the most commonly used heating system, the next was electric heater and then steam boiler. The industrial air conditioner has been widely used for cooling. And humidity was controlled mostly by ultra-wave or centrifuging humidifier. But some farmers has been using nozzle system for auxiliary purpose. More then $90\%$ of the mushroom house had the independent environment control system. The inside temperature was usually controlled by sensor, but humidity and $CO_2$ concentration was controlled by timer for each growing stage. The capacity of medium bottle was generally 850 cc and 1100cc, some farms used 800 cc, 950 co and 1,250 cc. Most of mushroom producted has been usually shipped to both circulating company and joint market.