• Title/Summary/Keyword: 분무탑

Search Result 12, Processing Time 0.028 seconds

Experimental Study on the Characteristics of CO2 Capture with Spray Towers Using Ammonia Solution (암모니아수 흡수제를 사용하는 분무탑의 이산화탄소 포집 기본특성에 관한 실험적 연구)

  • Lim, Youngbok;Choi, Munkyoung;Lee, Jinwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.2
    • /
    • pp.165-172
    • /
    • 2014
  • Experiments were conducted to identify basic characteristics of $CO_2$ capture using a spray tower with a single nozzle. Results were evaluated in terms of $CO_2$ saturation which is the main determining factor of regeneration energy, and capture efficiency under various operating conditions. Changes in the capture efficiency under various conditions are well expressed as a monotone increasing function of the relative solvent $(NH_3):CO_2$ flow rate. Although changes in $CO_2$ saturation are also well described as a function of the $NH_3/CO_2$ flow rate ratio, these are expressed as a monotone decreasing function, in contrast with the increasing function of $CO_2$ efficiency. In recent research on the relationship between $CO_2$ saturation and capture efficiency, $CO_2$ saturation was found to decrease when capture efficiency increased. In conclusion, the results show that the amount of solvent used for achieving high capture efficiencies is excessive, as is the amount of regeneration energy needed.

Design of gas suspension absorber to improve desulfurization efficiency

  • Hwang, Woohyeon;Lee, Kyung-Ok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.2
    • /
    • pp.189-195
    • /
    • 2020
  • In this study, the inlet duct and guide vane of the gas floating absorption tower were redesigned to improve the desulfurization efficiency so that the exhaust gas can be uniformly introduced into the absorption tower. In order to reduce the sulfur oxide pollutants among the main sources of air pollutants in industrial boilers, the existing equipment is redesigned and solved. For this purpose, change the exhaust gas, the slurry and recycling the adsorbent to improve the removal efficiency of SOx component in the exhaust gas inside the gas floating absorption tower so as to uniformly contact. And the initial design value and CFD value for the pressure loss from the boiler outlet to the gas floating absorption tower outlet are verified. Also, the velocity distribution of the exhaust gas, the concentration distribution of the recycled adsorbent, the liquid slurry behavior, and the pressure loss were compared. The results confirmed that the desulfurization efficiency was improved because the pressure loss from the boiler outlet to the absorption tower outlet was reduced and the deflection of the exhaust gas was minimized.

Characteristics of Solid Regenerable $CO_2$ sorbents for Pre-combustion $CO_2$ Capture (연소전 $CO_2$ 포집용 분무건조 고체 흡수제의 물성 및 $CO_2$ 흡수 특성)

  • Baek, Jeom-In;Ryu, Jungho;Lee, Joong Beom;Eom, Tae-Hyoung;Kim, Ji-Woong;Jeon, Eon-Sik;Ryu, Chong Kul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.110.2-110.2
    • /
    • 2010
  • 현재 상용가능한 연소전 $CO_2$ 포집 기술은 습식 스크러빙 방식으로 고온의 합성가스를 상온 수준으로 온도를 낮춘 후 $CO_2$를 포집해야 하고 포집된 $CO_2$의 압력이 낮아 재압축하여 저장소로 보내야 함에 따라 큰 폭의 열효율 손실이 불가피하다. 고온 고압에서 이산화탄소를 포집할수 있는 고체 흡수제를 이용할 경우 이산화탄소 포집 치 저장 추가에 따른 시스템 효율 저하를 최소화할 수 있다. 고체 $CO_2$ 흡수제는 서로 연결된 두 개의 유동층 반응기를 순환하면서 흡수탑에서는 합성가스 중의 $CO_2$를 흡수하고 재생탑에서는 고온의 수증기와 접촉하여 흡수된 $CO_2$를 다시 배출함으로써 재생된다. 따라서 건식 재생 $CO_2$ 흡수제는 유동층 공정에 응용가능한 물성과 함께 높은 $CO_2$ 흡수능과 빠른 반응성이 요구된다. 본 연구에서는 유동층 공정에 적합한 물성을 가진 연소전 $CO_2$ 포집용 고체 흡수제를 분무건조법으로 제조하였으며, 모사 합성가스를 이용하여 열중량분석기와 기포유동층반응기를 이용하여 $200^{\circ}C$ 흡수, $400^{\circ}C$ 재생, 압력 20 bar 조건으로 반응성을 측정하였다. 개발된 고체 $CO_2$ 흡수제는 열중량분석기에서는 반응 후 10-13 wt%의 무게증가를 나타내었고 기포유동층반응기에서는 8-10 wt%의 $CO_2$ 흡수능을 보여주었다. 특히 수증기의 함량이 10% 이상에서 높은 흡수능을 나타내어 수증기가 반응에 크게 작용하고 있음을 알 수 있었다.

  • PDF

Characteristics of Closed Circuit Cooling Tower with Multi Path on Cooling Water Inlet Conditions (냉각수 변화에 따른 멀티패스 밀폐식 냉각탑의 성능)

  • Shim, Gyu-Jin;Baek, Seung-Moon;Moon, Choon-Geun;Yoon, Jung-In;Kim, Eun-Pil;Kwon, O-Ick
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.597-602
    • /
    • 2008
  • The experiment of performance about closed-wet cooling tower(CWCT) was conducted in this study. The test section has the cooling water that flows from top part of a heat exchanger that has an entrance of cooling water with one and multi path. The heat exchanger consists of 15.88mm tubes with ten rows and ten columns and staggered arrangement. In this experiment, heat and mass transfer coefficients and range are calculated with variations of cooling water and path. The results indicated that operating CWCT using two path have the high values of heat and mass transfer coefficients and range than one path.

  • PDF

Characteristics of Closed Circuit Cooling Tower with Variation of Tube Diameter (멀티패스 밀폐식 냉각탑의 관경변화 특성)

  • Shim, Gyu-Jin;Lee, Ho-Saeng;Kim, Eun-Pil;Yoon, Jung-In;Kwon, O-Ick
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.531-536
    • /
    • 2008
  • This paper presents experimental result of characteristics about Closed circuit Cooling Tower having a rated 2RT. The experimental apparatus has been set-up with a conventional type system. The test section is heat exchangers of cooling tower that consist of different vertical tubes, 15.88mm with 10 rows and columns and 19.05 mm with 8 rows and 12 columns. The main results were summarized as follows : The values of heat and mass transfer coefficients of cooling tower operating with two paths are higher than these with one path. Cooling capacity per unit volume using 15.88mm tubes are higher than 19.05mm tubes.

  • PDF

A Study on the Factors of affecting the Heat Exchanger for Closed Cooling Tower (밀폐형 냉각탑용 열교환기의 성능에 영향을 미치는 인자에 관한연구)

  • Lee, Sang-Sik;Yoo, Seong-Yeon;Kim, Jin-Hyuck;Ryu, Hae-Sung;Park, Hyoung-Joon
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.250-255
    • /
    • 2008
  • Most high-rise building and large building require a cooling tower. Closed cooling tower is a low noise and the high efficiency. also Closed cooling tower is available for four season. Performance of Closed cooling tower is judged by heat transfer coefficient. In this study, Heat transfer coefficient is compared with air velocity, spray flow, heat exchanger type.

  • PDF

Reaction Characteristics of Desulfurization Sorbents for Warm Syngas Cleanup (석탄 합성가스 정제용 탈황제의 흡수/재생 온도 변화에 따른 황흡수 특성)

  • Baek, Jeom-In;Ryu, Jungho;Lee, Joong Beom;Eom, Tae-Hyoung;Lee, Kisun;Wi, Yong-Ho;Ryu, Chong Kul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.107.1-107.1
    • /
    • 2010
  • 고체 흡수제를 이용한 석탄합성가스 중의 황제거 기술은 습식 스크러빙 방식에 비해 고온에서 운전가능하므로 석탄가스화복합발전의 효율 향상을 가져올 수 있다. 고체탈황제는 서로 연결된 두 개의 유동층 반응기를 순환하면서 흡수탑에서는 합성가스 중의 $H_2S$로부터 황을 흡수하고 재생탑에서는 공기 중의 산소와 흡수된 황이 반응하여 $SO_2$를 배출하고 재생된다. 따라서 고체 황 흡수제는 유동층 공정에 응용가능한 물성과 함께 높은 황흡수능과 빠른 반응성이 요구된다. 본 연구에서는 기존 개발된 고체 탈황제가 가졌던 소성시 수축 현상, 낮은 내마모도 등을 개선하기 위해 지지체 조성을 변경하여 개발한 분무성형 탈황제의 흡수 재생 온도에 따른 황흡수 특성 변화를 조사하였다. $H_2S$ 1 vol. %를 함유한 모사 합성가스를 이용하여 흡수온도 450, $500^{\circ}C$, 재생온도 500, 550, 600, $650^{\circ}C$에서 황 흡수능을 열중량분석기를 이용하여 측정하였다. 개발된 흡수제는 유동층 공정 적용에 적합한 훌륭한 물성(형상, 밀도, 강도 등)과 함께 $500^{\circ}C$ 흡수와 $650^{\circ}C$ 재생을 기준으로 10 wt% 이상의 높은 황흡수능을 보여주었다. 흡수온도 변화는 황 흡수능 변화에 큰 영향을 미치지 않았으나, 재생온도가 $600^{\circ}C$ 이하인 경우 황흡수능이 5 wt% 이하로 크게 떨어져 재생온도를 $650^{\circ}C$ 이상 유지시키는 것이 중요함을 알 수 있었다.

  • PDF

Deterioration Diagnosis and Source Area of Rock Properties at the West Stone Pagoda, Gameunsaji Temple Site, Korea (감은사지 서탑의 풍화훼손도 진단 및 석재의 산지추정)

  • Lee Chan Hee;Lee Myeong Seong;Suh Mancheol;Choi Seok-Won;Kim Man Gap
    • Economic and Environmental Geology
    • /
    • v.37 no.5
    • /
    • pp.569-583
    • /
    • 2004
  • The rock properties of the West pagoda in the Gameunsaji temple site are composed mainly of dark grey porphyritic granodiorite with medium grained equigranular texture and developed with small numerous dioritic xenoliths. These xenoliths occurred with small holes due to different weathering processes. As a weathering results, the rock properties of this pagoda occur wholly softened to physical hardness because of a complex result of petrological, meteorological and biological causes. Southeastern part of the pagoda deteriorated seriously that the surface of rock blocks showed partially exfoliations, fractures, open cavities in course of granular decomposition of minerals, sea water spray and crystallization of salt from the eastern coast. The Joint between blocks has small or large fracture cross each other, contaminated and corrupted for inserting with concrete, cement mortar, rock fragments and iron plates, and partially accelerated coloration and fractures. There are serious contamination materials of algae, fungus, lichen and bryophytes on the margin and the surface on the roof stone of the pagoda, so it'll require conservation treatment biochemically for releasing vegetation inhabiting on the surface and the discontinuous plane of the blocks because of adding the weathering activity of stones and growing weeds naturally by soil processing on the fissure zone. Consisting rock for the conservation and restoration of the pagoda would be careful choice of new rock properties and epoxy to reinforce for the deterioration surfaces. For the attenuation of secondary contamination and surface humidity, the possible conservation treatments are needed.

Characteristic Study for Methyl-mercaptain Removal by an Essential Oil (식물추출물을 이용한 메틸멀캡탄 제거 특성 연구)

  • Park, Young-Gyu
    • KSBB Journal
    • /
    • v.22 no.3
    • /
    • pp.151-156
    • /
    • 2007
  • Increasing public concerns over odors and air regulations necessitates the remediation of a wide range of odorous compounds for industrial purpose. Currently, wet scrubbing technique by neutralization using essential oils is utilized to treat methyl mercaptan odor. The chemical analysis is performed to analyze the composition of an essential oil by GC-MS. The objective of this study is to clarify the possibility of the neutralization of odors sprayed in the fixed bed and determine the removal efficiencies in the misty aerosol by different input odor concentration. It is found that methyl mercaptan is significantly removed in the wet scrubber, and their removal efficiency of methyl mercaptan is obtained by 98%.