• Title/Summary/Keyword: 분무냉각

Search Result 112, Processing Time 0.027 seconds

Comparison of the Characteristics of Spray Cooling between Water and Nanofluid Sprays (물과 알루미나 나노유체 분무의 분무냉각특성 비교)

  • Kang, B.S.;Lee, S.P.
    • Journal of ILASS-Korea
    • /
    • v.19 no.2
    • /
    • pp.88-93
    • /
    • 2014
  • Nanofluids is that metallic or nonmetallic nanometer-sized particles are dispersed in liquid and they can be used in various fields to increase the heat transfer rate. This study conducted experiments to evaluate whether the cooling efficiency of nanofluids is better than that of water in spray cooling. A heated surface was designed and fabricated to make the temperature distribution be linear, which was confirmed by three thermocouple measurements under the heated surface. Spray cooling experiments were conducted using water, 0.2% wt. (weight), and 0.5% wt. $Al_2O_3$ nanofluids at the pressure of 0.2 MPa and 0.3 MPa. Based on the results, it is shown that the cooling efficiency of nanofluids is higher than that of water especially in the region of single phase heat transfer. As a result, we can expect that nanofluids can be used as efficient coolants in the cooling of electronic packages where the temperature of the heated surface is not high enough for boiling incipience.

미세물분무의 분사특성에 따른 n-Heptane 화염의 소화

  • 이경덕;김영수;신창섭
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2000.11a
    • /
    • pp.118-123
    • /
    • 2000
  • 화재에 대한 소화방법으로서는 점화원의 냉각, 산화제 농도의 감소에 의한 화염의 질식 및 제거소화와 부촉매를 이용한 소화법이 있다. 이중 냉각소화방법은 주로 물을 사용하여 화재를 진압하고 있으나, 유류화재와 전기화재 등에서는 물보다 할론소화약제가 효과적으로 사용되어 왔다. 그러나 할론 등 CFC 계통의 소화약제는 환경오염물질을 내포하며, 지구온난화지수와 오존파괴지수 등이 높아 전세계적으로 그 사용이 중단되고 있다. 이에 대한 대체 기술의 하나로 최근에 관심이 고조되기 시작한 소화기술은 분무 노즐을 이용한 미세물분무(water mist) 소화설비이다.(중략)

  • PDF

Study on Correlation of Critical Heat Flux in Spray Cooling (분무냉각에 있어서 임계열유속 상관식에 관한 연구)

  • Kim, Yeung Chan
    • Journal of ILASS-Korea
    • /
    • v.23 no.3
    • /
    • pp.109-113
    • /
    • 2018
  • The critical heat flux of spray cooling were measured on the test surface of 10 mm diameter made by stainless steel. The experiments were carried out for the droplet-flow-rate of $0.00002{\sim}0.003m^3/(m^2s)$ and liquid subcooling temperature of $40{\sim}75^{\circ}C$. Experimental results showed that the critical heat flux of spray cooling increased remarkably with the increase of droplet-flow-rate. Meanwhile, the effect of liquid subcooling on critical heat flux of spray cooling appeared weakly under the present experimental conditions. In additions, correlation between the dimensionless critical heat flux and Weber number based on droplet-floe-rate was developed for experimental results.

Study on Film Boiling Heat Transfer of Spray Cooling in Dilute Spray Region (희박 분무영역에서의 분무냉각 막비등 열전달에 관한 연구)

  • Kim, Yeung-Chan
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1481-1486
    • /
    • 2004
  • This report presents experimental results on the heat transfer coefficients in the boiling region of spray cooling for actual metallurgical process. In this study, the heat flux distribution of a two dimensional dilute spray impinging on hot plate was experimentally investigated. Based on the experimental results, they classified the heat transfer area into the stagnation region and wall-flow region. In the stagnation region, the local heat transfer coefficient relates mainly to the droplet-flow-rate supplied from spray nozzle directly, so the local heat transfer coefficients is good agreement with the predicted values from correlation for spray cooling proposed by former report However, the local heat transfer coefficient in wall-flow region is larger than predicted values, and it is found that the rebounding droplets-flow-rate must be accurately evaluated to predict the local heat transfer coefficient in this region.

  • PDF

Film Boiling Heat Transfer Model of Spray Cooling Focusing on Rebound Motion of Droplets (액적의 리바운드 모션에 주목한 분무냉각 막비등 열전달 모델)

  • Kim, Yeung-Chan
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1317-1322
    • /
    • 2004
  • In this report, the heat transfer model of spray cooling on hot surface was developed by focusing on the effect of rebound motion of droplets. In the model, it was assumed that droplets rebound repeatedly on the hot surface and heat transfer upon droplet impact is proportional to sensible heat which heats up the droplets to the saturation temperature. In addition, to take account of the contribution of th heat flux upon impact of rebound droplets, it was assumed that the rebound droplets are distributed following the Gaussian distribution from 0 to L, which distance L is determined by maximum flight distance $L_{max}$. Also the calculated results were compared with existing experimental results.

  • PDF

Film Boiling Heat Transfer Model of Spray Cooling Focusing on Rebound Motion of Droplets (액적의 리바운드 모션에 주목한 분무냉각 막 비등 열전달 모델)

  • Kim Yeung Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.2 s.233
    • /
    • pp.287-293
    • /
    • 2005
  • In the present study, to determine the flow rate of droplets supplied to heat transfer surface after (j-1)th rebound, $D_X[j{\ge}2]^{\ast}$, it was assumed that the rebound droplets are distributed according to the Gaussian distribution from 0 to L, in which the flight distance L is determined by maximum flight distance $L_{max}$. We also assumed that $L_{max}$ is dependent on the air flow velocity and mean size of droplets. The local heat flux of a dilute spray in high temperature region was predicted using the newly evaluated $D_X[j{\ge}2]^{\ast}$. In addition, the predicted results by the present model were compared with the existing experimental data.

The Effects of Heat-treatment on Magnetic Properties for Gas-atomized MPP Dust Cores (가스분무법으로 제조한 MPP 분말코어의 자기적 특성에 미치는 열처리 효과)

  • 노태환;김구현;김광윤;정인범;최광보
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.4
    • /
    • pp.173-178
    • /
    • 2001
  • The effects of heat-treatment with magnetic or non-magnetic field on magnetic properties of gas-atomized MPP dust cores subjected to various cooling processes after annealing were investigated. Upon magnetic-field annealing, ac permeability and core loss decreased with the increase of cooling rate, which were attributed to the generation of inhomogeneous internal stress and anomalous eddy current loss, respectively. It was not observed the formation of ordered phase and the related change in magnetic properties at the cooling stage for MPP dust cores. In MPP alloys, magnetic anisotropy was easily induced through the directional order, and permeability and core loss were changed under the conditions of low cooling rate and magnetic annealing.

  • PDF

A Study on the Spray Cooling Characteristics of hot Flat Plates (고온평판의 분무냉각특성에 관한 연구)

  • 윤석훈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.880-887
    • /
    • 1998
  • In order to study heat transfer characteristics of spray cooling for the purpose of uniform and soft cooling of high temperature surface a series of experiments for a hot horizontal copper flat plate was performed by downflow spray water using flat spray nozzle. Cooling curves were mea-sured under the various experimental conditions of flow rates and temperatures of cooling water Surface temperature surface heat fluxes and heat transfer coefficients of horizontal upward-facing flat surface were calculated with cooling curves measured at each radial positions near the cooling surface by TDMA method. Generally heat transfer characteristics for spray cooling is simi-lar to boiling phenomenon of pool boiling. The minimum heat flux(MHF) appear at the surface temperature of about ${\Delta}Tsat=250^{\circ}C$ and the critical heat flux(CHF) appear at about ${\Delta}Tsat=250^{\circ}C$.

  • PDF

Numerical Prediction of Spray Combustion and Film Cooling in a Liquid Rocket Engine (액체로켓 엔진의 분무연소 및 막냉각에 대한 수치해석)

  • 박태선;류철성
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.2
    • /
    • pp.9-17
    • /
    • 2002
  • For turbulent spray combustion flows a coupled numerical procedure was developed, This method was discretized by using generalized curvilinear coordinates to handle complex geometries. The preconditioning and eigenvalue rescaling techniques were employed to provide efficient convergences over a wide range of subsonic Mach numbers. The accuracy was validated by simulating the laminar cavity flow. The film cooling effect of a liquid rocket engine (KSR-III) were investigated by a spray combustion analysis. The film cooling showed a negative effect on the combustion efficiency. In the combustion chamber wall, the film cooling effect was revealed to be promoted by the production of fuel rich zone.

A Numerical Study on the Combustion Characteristics in a Liquid Rocket Engine with Film Cooling Effect (막냉각 효과를 고려한 액체로켓 엔진의 연소 특성에 관한 연구)

  • Byeon,Do-Yeong;Kim,Man-Yeong;Baek,Seung-Uk
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.8
    • /
    • pp.69-76
    • /
    • 2003
  • For stable combustion and safety of a structure of the propulsion system, a cooling system to the liquid rocket engine should be incorporated. In this study, Eulerian-Lagrangian scheme for two phase combustion, nongray radiation and soot formation effect, and film-wall interaction have been introduced to study the effect of film cooling. After briefly introducing the governing equation, combustion characteristics with change of wall temperature has been investigated by varying such parameters as fuel mass fraction for film cooling, diameter of the fuel droplet, overall mixture fraction of oxygen to fuel. Also, radiative heat flux is compared with the conductive one at the combustor wall.