• Title/Summary/Keyword: 부 구조물

Search Result 2,400, Processing Time 0.03 seconds

Second Order Elastic Analysis of Superstructures on Very Large Floating Structure with Semi-Rigid Connections (반강접 접합부를 적용한 초대형 부유식 구조물 상부구조체의 2차 탄성해석)

  • Song, Hwa-Cheol;Lee, Eun-Suk
    • Journal of Navigation and Port Research
    • /
    • v.27 no.1
    • /
    • pp.63-70
    • /
    • 2003
  • If semi-rigid connections are used for superstructures of very large floating structures (VLFS), the number of rigid connections can be reduced and more economical construction will be possible. In this study, considering service load and wave load in VLFS, the applicability of mixed use of rigid and semi-rigid connections have been studied using three types of connections for a four-bay eight-story frame. Three types of connections are used; top and seat-angle connections with double web-angle(TSD), extended end plate connections, steel tubular column with square external-diaphragm connections. ABAQUS(Finite element analysis program) is used for conducting second order elastic analysis.

Vibration Response Analysis of Caisson Structure-Foundation Interface using Forced Vibration (강제진동해석을 통한 케이슨 구조-지반 경계의 진동응답 분석)

  • Lee, So-Ra;Lee, So-Young;Kim, Jeong-Tae;Kim, Heon-Tae;Park, Woo-Sun;Yi, Jin-Hak
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.145-148
    • /
    • 2010
  • 항만 구조물의 건전성 평가 기술의 개발을 위한 기초 연구로서, 강제진동해석을 통하여 케이슨 구조-지반 경계부의 손상에 대한 진동응답을 분석하고자 한다. 이를 위해 세 단계의 연구를 수행하였다. 첫째, 케이슨 구조물의 진동특성 분석을 위해 시간영역기반의 AR(auto-regressive)모델을 선정하였다. 둘째, 모형 케이슨 구조물을 대상으로 진동응답 계측실험을 수행하였으며, AR-모델을 통해 진동특징을 실험적으로 분석하였다. 셋째, 대상 케이슨 시스템의 유한요소모델을 구성하고, 구조-지반 경계부의 손상에 따른 동적응답 특성의 변화를 수치적으로 분석하였다. 이를 위해 강제진동을 모사 하였으며, 구조-지반 경계부의 강성변화에 따른 케이슨 구조물의 진동응답의 변화를 분석하였다.

  • PDF

Development of Temperature Control Technology for Massive Machine Foundations (기계기초 매스콘크리트의 균열제어를 위한 온도관리기법의 개발)

  • Huh, Taik-Nyung;Son, Young-Hyun;Lee, Suck-Hong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.4
    • /
    • pp.227-233
    • /
    • 2001
  • 최근 비약적인 경제발전에 힘입어 장대교량, 항만, 댐, 도로, 원자력 발전소 등과 같은 대규모 기간구조물의 건설이 증가하고 있으며, 구조물은 대형화 혹은 고강도화되는 추세에 있다. 특히, 전술한 구조물을 매스콘크리트로 가설하게 되면 초기재령시에 수화열로 인한 균열이 발생할 가능성이 매우 높기 때문에 효율적인 매스콘크리트의 개발과 매스콘크리트 구조물의 설계기술 및 시공방법이 중요한 연구대상으로 등장하게 된다. 본 논문에서는 가로 52.6m, 세로 14.4m, 높이 8.5m의 기계기초 매스콘크리트의 시공에 적합한 온도관리기법을 다음과 같은 단계로 제안하고자 한다. 먼저 온도상승요인을 최소화하는 콘크리트의 배합비를 산정한다. 산정된 콘크리트의 열특성을 측정하기 위해 단열온도실험을 수행하여 각종 열특성상수와 단열온도 상승곡선식을 도출한다. 이와 같은 열특성치를 콘크리트 구조체에 적용하여 열응력해석을 수행한다. 이와 같은 열응력해석을 통하여 구조물의 분할타설높이에 따라 온도균열이 발생하지 않는 콘크리트 내외부의 온도차를 결정한다. 이때 열응력해석에 범용 유한요소 프로그램인 Diana을 사용한다. 콘크리트의 타설은 현장조건과 타설시점을 최대로 고려하고 양생방법으로 콘크리트 내외부의 온도차를 최소화하기 위해 이중단열효과가 있는 거푸집과 가열장비을 사용한다. 또한 콘크리트의 온도관리를 위하여 구조물 내외부에 온도게이지를 매립하고 30분마다 계측을 수행하면서 콘크리트 내외부 온도차가 허용 해석범위를 유지하도록 한다. 양생기간은 7-10일 정도를 유지한다. 전술한 온도관리기법을 통하여 완공후 수평정밀도가 기초의 허용침하량으로 환산하여 $1{\mu}m$ 인 고정밀도의 기계기초는 완벽하게 시공되었다. 따라서 매스콘크리트의 온도균열을 제어할 수 있는 시공방법으로 제안한다. 또한 매스콘크리트의 내외부 온도차를 단열온도실험과 온도해석으로부터 정한 값이내로 제어하고 충분한 양생관리를 병행하면 수화열에 의한 콘크리트의 온도균열을 최소화할 수 있을 것으로 기대한다.

  • PDF

Structural Performance Evaluation of Connection with Inclined Column for Steel Structure Subjected to Vertical Loads (수직하중에 따른 강구조물 경사기둥 접합부의 구조성능평가)

  • Kim, Eun-Suk;Cho, Jeong-Hyeok;Kim, Tae-Jin;Kim, Jong-Ho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.255-258
    • /
    • 2010
  • 최근 초고층 구조물은 다양한 형태에 따른 건축 계획 및 설계에 대한 요구되어지며 이를 충족시키기 위해 다양한 구조시스템이 개발되어지고 있다. 특히 경사기둥은 구조물의 높이가 증가할수록 구조물의 면적이 점차적으로 감소하는 Tapered 형태의 비정형 초고층 구조물의 중요한 설계 및 구조요소이다. 본 논문에서는 경사기둥의 축하중에 의해 발생하는 수평력으로 인한 접합부의 영향 및 보 플랜지의 취성파괴에 대한 저항성능을 평가하기 위하여 강구조물 경사기둥 접합부에 대한 유한요소해석을 수행하였다.

  • PDF

Influence of Analytical Models on the Seismic Response of Modular Structures (모듈러 구조물의 해석 모델이 지진응답에 미치는 영향)

  • Choi, Kyung-Suk;Lee, Ho-Chan;Kim, Hyung-Joon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.2
    • /
    • pp.74-85
    • /
    • 2016
  • Seismic design of modular structures is usually carried out under the assumption that their load-carrying mechanism is similar to that of traditional steel moment-resisting frames(SMRFs). However, the load carry mechanism of modular structures would be different with that of traditional SMRFs because of their overlapped structural elements and complicated details of connections for the assembly of the unit-modules. In this study, nonlinear static analyses of 3 and 5-story prototype modular structures have been carried out with four different analytical models, which are established in consideration for the effects of overlapped elements and the hysteretic behavior of connections. Prototype structures present different lateral stiffness and strength depending on the modeling of overlapped elements and the rotational behavior of connections. For modular structures designed under assumption that overlapped structural elements are fully composite each other and connections between unit-modules are fixed, their lateral strength and stiffness can be over-estimated. Furthermore, it is known from the analysis results that modular structures with more than 3-stories would possess relatively low overstrength compared to traditional SMRFs.

Self Healing Bolted Joints System Using Shape Memory Alloy Washer (형상기억합금 와셔를 이용한 볼트접합부 자가치유 시스템)

  • Chang, Ha-Joo;Park, Seung-Hee;Lee, Chang-Gil;Kim, Tae-Heon;Nam, Min-Jun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.315-318
    • /
    • 2011
  • 본 논문에서는 구조물 연결부의 실시간 손상 검색을 통해 이상이 감지되었을 경우 자가치유까지 가능한 지능형 볼트접합부 시스템에 관한 실험적 연구결과가 제시되었다. 지능형 센서인 PZT센서의 전기-역학적 커플링 특성을 이용한 전기역학적 임피던스 기반의 구조물 건전성 평가 방법이 사용되었다. 전기역학적 임피던스의 측정을 통한 계측값을 베이스라인 값과 비교하는 손상 평가를 통해 구조물 볼트접합부의 볼트풀림 손상을 진단하고, 손상은 손상지수 RMSD를 통하여 정량화되었다. 볼트접합부의 손상이 감지되었을 경우 형상기억합금(SMA) 와셔에 부착되어있는 히팅 필름에 전원을 가함으로써 형상기억합금에 열을 가하고, 가열된 형상기억합금 와셔는 축방향으로 팽창을 함으로써 잃었던 볼트의 토크력을 회복시켜주었다. 실험 결과, 제안된 전기역학적 임피던스 기반의 구조물 건전성 평가기법과 형상기억합금 와셔 기반의 볼트접합부 자가치유 시스템의 성능 평가와 검증이 이루어졌다.

  • PDF

Techniques for Revetment Design around River-Crossing Structures (하천횡단구조물 연결호안 설계 기법 검토)

  • Yoon, Kwang-Seok;Bae, Deok-Won;Kim, Hyeong-Jun;Ryu, Yong-Uk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1931-1935
    • /
    • 2010
  • 최근 기후변화에 의한 강우량 및 집중호우의 증가로 인하여 설계규모를 초과하는 홍수발생 가능성이 커지고, 이에 따라 제방월류 위험성이 증대되고 있다. 특히, 하천을 횡단하는 보 또는 낙차공이 있는 경우, 구조물 영향에 의해 국부적으로 유속이 증가하여 연결호안을 유실시킴으로서 제방붕괴에 의해 홍수피해가 가중될 수 있다. 과거 피해사례를 보면 횡단구조물과 제방과의 연결부가 세굴되어 파괴되는 사례가 많이 발생하고 있으며, 이는 하천횡단구조물 주위에 설치되는 연결호안에 대한 정량적인 설계기법이 정립되어야 할 필요성을 보여 준다. 경험적인 요소만으로 연결호안의 안정성을 판단함으로써, 과소설계에 의한 홍수피해가 발생하거나, 과대설계에 의한 비용손실을 초래하게 된다. 본 연구에서는 기존에 제시되어 있는 호안설계식을 연결부에서의 국부유속증가특성을 고려하여 적용한 결과를 비교하였다. 비교 결과, 연결부에서의 호안 크기가 증가될 필요가 있으며, 이에 대한 실험 실증적 연구가 필요한 것으로 분석되었다.

  • PDF

Ultrasonic Nondestructive Testing for Welded Steel Pipes (강관 용접부의 초음파 비파괴검사)

  • Shin, Byoung-Chul;Kim, Il-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.4
    • /
    • pp.172-176
    • /
    • 1998
  • 강관 등과 같이 곡면을 이루는 구조물 용접부의 내부 결함을 검출하기 위한 기법을 제안하였다. 인공 결함을 만들어 초음파 비파괴검사를 행하고, 곡면의 표면 거리($Y_s$)를 계산하여 실측한 참값($Y_T$)과 비교해 보았다. 제안된 방법으로 계산한 값이 참값에 대하여 1%이하의 오차 범위에 들어오므로 강관 용접부의 내부 결함 검사에 응용될 수 있다.

  • PDF

Effects of Semi-Rigid Connection and Foundation Type on Static Behavior of Plastic Greenhouse (부재 교차부와 기초 조건이 비닐하우스의 정적거동에 미치는 영향)

  • Ryu, Hee-Ryong;Cho, Myeong-Whan;Yu, In-Ho;Lee, Eung-Ho;Woo, Jong-Gyu;Lee, Jae-Young
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.61-62
    • /
    • 2011
  • 비닐하우스는 매우 세장한 강관부재들을 교차 결합하여 조립한 철골 구조물의 한 종류이다. 현행 설계기준으로 단동 비닐하우스의 최대 구조성능은 풍하중 40m/s, 설하중 50cm에 달한다. 그러나 설계 단계에서는 부재들의 교차결합 특성 및 부재가 직접 지반에 삽입되는 기초의 특성이 적합하게 반영되지 않는 문제점이 있다. 따라서 가력시험을 통하여 반강접 특성을 갖는 부재 교차부 및 지반삽입기초 조건이 구조물의 거동에 미치는 영향을 분석하였다. 부재 교차부가 강접 조건일 경우와 비교하여 교차부가 반강접일 경우에는 재하지점의 수평강성이 최대 54% 작게 나타났으나 주변 교차절점들에서의 에너지 흡수로 인하여 재하지점과 수평으로 3m 떨어진 지점에서는 반대로 최대 39% 큰 값을 보였다. 지반삽입기초의 경우에는 고정조건과 비교하여 재하지점의 수평강성이 최대 32% 작게 나타났으며, 지점부에서는 기초 조건의 영향으로 최대 26%의 휨강성 증가 효과를 보였다. 부재 교차부와 기초 조건이 구조물의 정적거동에 미치는 영향을 확인하였으나 최대내력과 강성 산정을 통한 구조성능 평가 방법의 개발이 필요할 것으로 판단된다.

  • PDF

Mechanical Stress Relief Technology and its Application (MSR을 이용한 용접잔류응력의 제거와 적용성 검토)

  • 박지선;한명수;한종만
    • Journal of Welding and Joining
    • /
    • v.15 no.3
    • /
    • pp.29-35
    • /
    • 1997
  • 실제로 용접구조물의 재료에는 항상 내부 잔류응력이 존재하며 그 크기는 재료내의 내부 잔류응력간의 평형의 원리(Self-equilibrating system)에 의해 결정 된다. 일반적인 구조 강도설계에서 행해지는 탄성해석에서는 재료 내부에 존재하는 잔류응력을 고려하지 않기 때문에 설계시에 계산된 응력이 심하중하의 구조물에서 발생하는 응력과 같다고 볼 수는 없다. 철강재료를 사용한 구조물의 경우 구조물 제작 공정 전반에 걸친 성형가공 및 조립과정에 수반되어 재료 내에는 잔류응력이 발생되며 특히 용접조립에 의해 용접부 근방에서는 재료의 항복강도 수준의 상당히 큰 용접응력 이 발생하게 된다. 일반적으로 용접잔류응력의 완화법으로 가장 확실한 방법은 후열 처리법(Post weld heat treatment, PWHT)이지만 이 방법의 적용은 구조물의 크기에 제한을 받게 된다. 따라서 PWHT를 적용하기 어려운 구조물에 대해서는 다른 방법에 의해 용접잔류 응력을 완화시켜야 하며 이 경우에 일반적인 방법으로 기계적 응력완화 법(Mechanical stress relief method, MSR)이 있다. 본고에서는 MSR의 기본원리에 대하여 간단하게 정리하고 실 구조물에 대한 MSR 적용시 고려해야 할 제반사항을 위하여 단순 용접부에 대한 MSR 적용 실험결과와 실제 압력용기를 대상으로 MSR을 자체 제작된 기술절차서에 따라서 시행하고 MSR의 적용성에 대해서 검토하였다.

  • PDF