• Title/Summary/Keyword: 부하하중

Search Result 108, Processing Time 0.025 seconds

CO2 Emissions Evaluation for Steel Reinforced Concrete Columns Based on the Optimal Structural Design (최적구조설계를 이용한 SRC 기둥의 CO2 배출량 평가)

  • Choi, Se Woon;Jeon, Ji Hye;Lee, Hwanyoung;Kim, Yousok;Park, Hyo Seon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.5
    • /
    • pp.335-342
    • /
    • 2013
  • Since the seriousness of environmental pollution came to the fore recently, various efforts have been made globally for the reduction of the environmental load. In particular, in the field of construction, an industry responsible for a considerable amount of pollution, studies have been actively conducted to reduce $CO_2$ emissions and energy consumption. However, most conventional research about pollution as it relates to construction is focused on the maintenance stages where $CO_2$ emissions are the greatest. Research related to the design stage is in its infancy, as it has only been conducted thus far on steel buildings and RC buildings. In fact, in order to achieve environmentally friendly construction considering the Life Cycle Assessment(LCA), the building design should be derived to reduce the $CO_2$ emissions from the early building design stage, and structural engineers should be able to suggest a design plan considering its environmental friendliness. In this study, optimal structural design method for steel reinforced concrete(SRC) columns considering $CO_2$ emissions is presented. The trends of $CO_2$ emissions in SRC columns according to the variations of steel shapes, concrete strengths and loads are investigated.

A Study on Physical and Chemical Properties of Vegetation Foundation for Rooftop Greening Using Wood Waste (폐목질 자원을 이용한 옥상녹화용 식생기반재의 물리 및 화학적 특성에 관한 연구)

  • Kim, Dae-Young;Kim, Mi Mi
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.79-87
    • /
    • 2008
  • Many researchers have studied on rooftop greening that can be installed in abandoned spaces on a building roof. The most important issue in rooftop greening is the soil weight problem. The light greening materials are needed to solve this problem. Therefore, many alternative materials against the soil were investigated for rooftop greening. In this study, the waste wood chips and the waste paper slurry were evaluated as the lightweight vegetation foundation for rooftop greening. It also has a meaning for recycling of waste materials. The mixture ratio of waste wood chips to waste paper slurry for the board (the foundation of greening) was 60 to 40. The wet strength resin and the sizing agent were additionally added with different amount. After the forming of the board, physical and chemical properties were tested with the variation of wet strength resin and sizing agent. As the result of the test, the board with 15% of wet strength resin in the wet condition showed the highest strength. Futhermore, the moisture evaporation loss from the board surface with sizing agent was much lower than that from the board without sizing agent. Therefore, it was clear that the sizing agent was effective for water retention. The change of thickness in the wet condition was less than 1 mm, and it showed that the board is the predominant material on the dimensional stability. The average pH value of the board was ranged from 7.6 to 8.25.

Characteristics for Progressive Collapse Behavior and Ultimate Strength of Very Large Marine Structure (초대형 해상구조물의 붕괴거동 및 최종강도 특성)

  • Park, Joo-Shin;Ko, Jae-Yong;Lee, Kyoung-Woo
    • Journal of Navigation and Port Research
    • /
    • v.33 no.5
    • /
    • pp.315-321
    • /
    • 2009
  • The Very Large Marine Structure has been widely used new method of ocean space instead of method for reclamation Therefore, VLFS is proposed to coincide on such request. It can be established regardless of nature of soil and height of water, and stream of flow exists under the floating structure, there is seldom effect in natural environment. Fuertherrnore, it can do easily to do assembly and taking to pieces due to expansion or removal. Based on the regulation by class, VLFS have to possess more than enough structural strength against severe wave loading induced by green sea condition Therefore, There are performed structural simulation as well as experimental test about expected loading scenario in order to examine the safety of structure. Up to now, various examinations based on the strength limit value of the main structural material have been done based on the elasticity response analysis. However, there is little finding about the collapse behavior and the safety when the load that exceeds the collapse of the material acts. In the present study, we investigated the collapse behavior based on the ultimate limit state calculated by FE-analysis.

An Experimental Study on Retrofit Effect of Shear Wall with Opening Using Steel Bar or Steel Plate (강봉 및 강판을 이용한 개구부를 갖는 전단벽의 보강효과에 관한 실험 연구)

  • Choi, Youn-Cheul;Bae, Baek-Il;Choi, Chang-Sik;Choi, Hyun-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.2
    • /
    • pp.129-138
    • /
    • 2009
  • Recently, for more demands of the economical benefits and environmental conservation, many engineers prefer to choose remodeling. Artificial openings are often unavoidable to make house wider, which will degrade wall strength and stiffness by losing effective wall section that may cause the weakening of system capacity. In these cases the damaged shear walls need to be retrofitted by additional materials or members. In this research, four specimens were tested to investigate the capacity of the damaged wall and the retrofitted wall. The artificially damaged wall was prestressed by tendons to improve the shear capacity of the wall, and the other walls were retrofitted by adding steel plate at the surface for the same purpose. Consequently, these retrofitted walls had improved capacity and stiffness in both shear and flexure. Especially, the wall with steel plate showed ductile behavior after ultimate load and the prestressed wall had greater stiffness than the unstrengthened prototype wall.

Seismic Resistance of Cast-In-Place Concrete-Filled Hollow PC Columns (현장타설 콘크리트 채움 중공 PC기둥의 내진성능)

  • Lim, Woo-Young;Park, Hong-Gun;Oh, Jung-Keun;Kim, Chang-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.1
    • /
    • pp.35-46
    • /
    • 2014
  • Two types of cast-in-place concrete-filled hollow PC (HPC1, HPC2) columns were developed to reduce lifting load of heavy-weight PC columns and to improve the structural integrity of joints. To form the hollow PC columns, a couple of prefabricated PC panels was used for HPC1, and special hoops were used for HPC2. Lateral pressure of wet concrete on PC faces was measured while placing the concrete inside the columns. To evaluate the seismic resistance, full scale specimens of two HPC columns and a conventional RC column were tested under combined axial compression and lateral cyclic loading. The test results showed that the structural performance of the proposed HPC columns such as intial stiffness, maximum strength, and displacement ductility was comparable to that of the conventional RC column, but the energy dissipation of HPC2 slightly decreased after rebar-buckling. However, all the test specimens satisfied the energy dissipation requirement specified in ACI 374.

국제핵융합실험로(ITER) 시험을 위한 한국형 시험증식블랑켓 개념설계 및 성능해석

  • Lee, Dong-Won;Jin, Hyeong-Gon;Lee, Eo-Hwak;Yun, Jae-Seong;Kim, Seok-Gwon;Park, Seong-Dae;Jo, A-Ra;An, Mu-Yeong;Jo, Seung-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.255-255
    • /
    • 2015
  • 국제핵융합실험로(ITER)의 3대 목표 중 하나는 핵융합로 개발을 위한 삼중수소증식블랑켓 개념을 시험하고 검증하는 것이며, 이를 위해 시험증식블랑켓(TBM, Test Blanket Module) 프로그램을 마련, 각국이 참여할 수 있도록 하고 있다. 한국도 2012년 국가핵융합위원회 결정에 따라, EU, 일본, 중국, 인도와 함께 TBM 프로그램에 참여하고 있으며, 2021년 설치를 목표로 헬륨냉각 고체증식재 개념의 HCCR (Helilum Cooled Ceramic Reflector) TBM을 설계, 개발하고 있다. 한국형 TBM은 총 4개의 서브모듈과 하나의 후벽(Back Manifold, BM) 으로 구성되며, 각 서브모듈은 플라즈마와 대면하는 일차벽(First Wall, FW), 증식재와 증배재, 반사재를 담고 있는 증식영역(Breeding Zong, BZ), 냉각재 매니폴드 및 구조물 역할을 하는 측벽(Side Wall, SW) 등의 기능부품으로 구성되어 있다. 냉각재는 8 MPa, $300-500^{\circ}C$의 고온고압헬륨을 사용하고, Li2SiO4 혹은 Li2TiO4 형태의 Li 세라믹 증식재를 사용하며, 중성자 증배를 위해 Be 증배재 및 흑연 반사재를 사용한다 [1-3]. 2015년 2월 개념설계검토(CDR, Conceptual Design Review)를 위해, TBM-shield를 포함한 TBM-set 설계가 완료되었으며, 열수력, 구조, 지진, 전자기, 복합하중에 대한 평가가 진행되었다. 본 논문에서는 이 중 H/He-phase에 시험될 EM-TBM과 D-T phase에 시험될 INT-TBM에 대한 열수력 성능 결과를 소개하였다[5]. 각각의 열부하 조건은 0.17과 $0.3MW/m^2$이며, 중성자 조사는 D-T phase 에서만 고려되었다. 구조재 및 사용된 기능소재별 온도 요건을 정의하고, 성능해석 결과와 비교하였으며, 이를 통해 모든 온도 요건을 만족함을 최종 확인하였다. 이러한 온도 분포는 열응력 평가를 위해 구조해석 입력자료로 활용되었다.

  • PDF

Analysis of Golf Swing Motion and Applied Loads on the Human Body Using Soft-$Golf^{TM}$ Club (소프트 골프 클럽을 이용한 골프 스윙 동작과 인체 작용 하중 분석)

  • Kwak, Ki-Young;So, Ha-Ju;Kim, Sung-Hyeon;Kim, Nam-Gyun;Kim, Dong-Wook
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.472-478
    • /
    • 2011
  • The purpose of this study was to analyze the kinetic effect of Soft-$golf^{TM}$ instrument on the human body structure. To analyze the kinetic effect of Soft-$golf^{TM}$ instrument, Golf swing using Soft-$golf^{TM}$ instrument and regular golf instrument was captured. And then Upper limbs and lumbar joint torques was calculated via computer simulation. Five man participated this study. Subjects performed golf swing using a regular golf and Soft-$golf^{TM}$ instrument. Golf swing motion was captured using three position sensor, active infrared LED maker and force plate. Golf swing model was generated and simulated using ADAMS/LifeMOD program. As a results, joint torque during Soft-golf swing were lower than regular golf swing. Thus soft-golf swing have joint load lower than regular golf swing and contribute to reduce joint injury.

Cyclic Lateral Loading Test for Cast-In-Place Concrete-Filled Hollow PC Columns Using Permanent Inner form (영구 내부거푸집을 이용한 현장타설 콘크리트 채움중공 PC기둥의 반복횡가력실험)

  • Lee, Ho-Jun;Park, Hong-Gun;Kim, Chang-Soo;Hwang, Hyeon-Jong
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.2
    • /
    • pp.129-139
    • /
    • 2016
  • Cast-in-place concrete-filled hollow PC (HPC) columns are used to reduce lifting load of heavy-weight PC columns and to improve the structural integrity of joints. In the present study, a new type of HPC column was proposed to improve the productivity and structural integrity of the concrete. To form the hollow PC columns, a permanent inner form was prefabricated using structural deck plates and penetrated lateral bars. Half-scale specimens of four HPC columns were tested under combined axial compression and lateral cyclic loading to evaluate the seismic resistance. In the design of test specimens, various parameters such as the spacing of lateral re-bars, the use of steel fiber, and the thickness of PC cover were considered. The test results showed that the proposed HPC columns generally exhibited satisfactory load-carrying capacity and deformation capacity without brittle failure of PC. If closely spaced hoops or fiber reinforcements are used for PC, the deformation capacity can be improved further by restraining PC spalling.

Prediction of Reliability of Fatigue Limit of S34MnV Steel for Marine Diesel Engine Crank Throw Components (선박용 디젤 엔진 크랭크 스로 부품용 S34MnV강의 피로한도에 대한 신뢰도 예측)

  • Kim, Seon Jin;Kong, Yu Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.8
    • /
    • pp.751-757
    • /
    • 2016
  • The aim of this study is to estimate the reliability of fatigue limit of the material used for crank throw components according to the staircase method. The material used for crank throw components is forged S34MnV grade steel, which is heat treated by normalizing and tempering. In this work, to predict the reliability of the design fatigue strength, axially loaded constant amplitude fatigue testing was conducted. The test specimens were loaded with an axial push/pull load with a mean stress of 0 MPa, which corresponds to a stress ratio of R=-1. The fatigue test results were evaluated by Dixon-Mood formulas. The values of mean fatigue strength and standard deviation predicted by the staircase method were 296.3 MPa and 10.6 MPa, respectively. Finally, the reliability of the fatigue limit in some selected probability of failure is predicted. The proposed method can be applied for the determination of fatigue strength for design optimization of the forged steel.

The Effects of Geometrical Imperfections on the Dynamic Characteristics of a Tapered Roller Bearing Cage (테이퍼 롤러 베어링 케이지의 불완전성이 통특성에 미치는 영향)

  • Ahn, Tae-Kil;Park, Jang-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.464-469
    • /
    • 2019
  • Tapered roller bearings are used widely in vans, trucks, and trains because they can support the vehicle in a stable manner even under a heavy load. The cage of a tapered roller bearing maintains the gap between the rollers, which prevents friction wear and suppresses heating. If the cage is severely deformed due to resonance, the roller may not be able to roll smoothly and even leave the cage. Consequently, it is very important to analyze the dynamic characteristics of the cage for reliable performance of a bearing. The cage essentially has geometrical tolerance in the manufacturing process. In this paper, the effects of those geometrical imperfections on the dynamic characteristics of the cage were investigated. As a result, natural frequency separation occurred near the natural frequency of the ideal cage due to geometrical imperfections. In addition, the interval was proportional to the magnitude of the geometric error, and the interval increased with increasing mode number.