• Title/Summary/Keyword: 부하토크

Search Result 219, Processing Time 0.024 seconds

A Study on the Sterling Characteristics for Capacitor-run Single Phase Permanent Magent Synchronous Motor (커패시터 운전 단상 영구자석형 동기전동기 기동특성에 관한 연구)

  • 홍선기
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.150-156
    • /
    • 2004
  • Although permanent magnet single phase synchronous motor which starts and runs through single phase voltage source has high efficiency, it is difficult to determine the rotating direction. In this paper, the starting characteristics of the capacitor-run single phase synchronous motor has been studied. The stator has same structure with the capacitor-run single phase induction motor, however the rotor consists of permanent magnet. In this case, the starting conditions according to the rotor and stator conditions are determined and the direction of the motor can be determined. From these results, it is desired that the proposed motor can be applied to the loads like the fans which has low starting torque.

Torque Measurement of Tripod Shaft for HSR-350x (한국형고속열차의 동력전달축 부하측정)

  • Kim, Sang-Soo;Kim, Young-Guk;Kim, Ki-Hwan;Park, Choon-Soo
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.6
    • /
    • pp.660-664
    • /
    • 2007
  • Korea High-speed Railway (HSR-350x) was developed by Korean government, several institutes, and related companies. HSR-350x was investigated its performance and tested at the high speed line. In 2004 December, HSR-350x was run over 350km/h and proved its running performance. And Korean Train Express (KTX) served the commercial traffic for 4 years. These high speed railways have 12 motors to transfer the traction effort or the braking force. To obtain the load of the transfer shaft, it is necessary to measure the transferred torque of the shaft. In this paper, authors propose the construction the measurement system fur monitoring the force transferred to the train from the motor The system was installed to the tripod shaft which is located between the reduction gears and it measures the mechanical load directly.

Aerodynamic Performance Test and Evaluation by Using the Subscale HAWT Blade Model (축소모델 공력실험에 의한 수평축 풍력발전 시스템용 블레이드의 공력성능 평가에 관한 연구)

  • 공창덕;방조혁;김하봉;김종식
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.39-39
    • /
    • 1998
  • 본 연구는 500KW급 수평축 풍력발전기용으로 개발된 회전날개의 시제품 제작에 앞서 축소모델에 대한, 이론적으로 예측된 공력성능과 신축에 의한 공력성능을 비교 검토함으로서, 설계결과를 검증하고, 필요한 경우 설계를 보완하여 개발위험도를 최소화하기 위해 수행되었다. 시험모델의 크기는 실제의 5%로서 직경이 2.1m이며 날개의 시위길이는 0.2r/R에서 0.101m, 날개끝에서 0.043m 이고, 날개단면형 상온 FX-S-03-182이다. 블레이드의 재질은 Glass/Epoxy 복합재료로 제작되었으며, 실제 풍황을 모사하기 위해 자연풍 상태에서 실험하였다. 실험장치의 구성은 15m 높이의 타워에 회전날개와 전자브레이크 및 각종 센서를 장착하였고, 날개가 회전하기 시작하면 제동장치에 의해 부하를 주면서 토크, 회전수, 풍속 등을 각각의 센서로부터 자료획득장치를 통해 자료처리를 할 수 있도록 하였다. 실험하는 동안 풍속은 4m/s-13m/s 정도로서 시동 풍속인 4m/s와 정격풍속인 12m/s를 포함하여 회전날개의 전체적인 특성을 파악하기 용이하였고, 이론적인 예측성능과 측정된 성능을 비교 검토한 결과 비슷한 결과를 얻어 공력설계 및 해석 방법을 검증하였다.

  • PDF

The Control of 3-Phase Induction Motor by Hybrid Fuzzy-PID Controller : Auto-Tuning of Parameters using Genetic Algorithms (하이브리드 퍼지-PID 제어기에 의한 3상 유도 전동기의 속도제어 : 유전자 알고리즘에 의한 파라미터의 자동 동조)

  • Kwon, Yang-Won;Ahn, Tae-Chon;Kang, Hak-Su;Yoon, Yang-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.794-796
    • /
    • 1999
  • 본 논문에서는 3상 유도전동기의 속도를 제어하는데 기존 제어기의 문제점을 해결하고 최적화하기 위해서 유전자 알고리즘을 이용한 하이브리드 퍼지 -PID(HFPID) 제어기를 고안하고, 이에 대한 파라미터 설정 방법을 제안한다. 유도전동기의 제어는 지연시간이 길고, 비선형성이 강하며, 부하변동이 잦은 프로세스이기 때문에, 기존의 제어방식으로는 만족할만한 결과를 얻을 수 없다. 제안한 하이브리드 퍼지-PID 제어기는 PID 제어기의 장점인 과도기의 우수성과 퍼지 제어기의 장점인 정상기의 우수성을 퍼지 변수로 결합시켜 설계한다. 이 제어기에 유전자 알고리즘을 적용하여 최적의 퍼지 및 PID 파라미터를 설정하다. 그리고 이 제어기를 3상 유도전동기의 속도 제어에 응용한다. 또한 속도오차에 대한 룩업 표를 만들어 온라인 실시간 제어를 가능하게 한다. 이상의 과정을 3상 유도전동기에서 컴퓨터 시뮬레이션 하였다. 시뮬레이션 결과를 비교해 볼 때, 하이브리드 퍼지-PID 제어기는 기존의 제어기 보다 전동기의 속도 및 토크성분 전류 둥의 특성에서 우수한 성능을 보였다.

  • PDF

IT화 대응 변압기 유지보수$\cdot$지원시스템

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.299
    • /
    • pp.70-75
    • /
    • 2001
  • 최근 몇 년 사이 설비투자가 억제되어 고경년(高經年)변압기나 과부하로 운전조건이 어려워진 변압기가 증가하고 있으며, 이에 따라 기기의 운전신뢰성 유지와 정비$\cdot$보수를 위한 토털코스트의 삭감 요구가 제기되고 있다. 변압기의 운전신뢰성을 유지하기 위한 센서 및 장치는 점검$\cdot$순시의 지원, 이상징후의 검출은 물론 기기의 상태를 정확하게 파악함으로써 적절한 유지보수의 지원을 목적으로 하는 것이 제품화되어 있다. 이와 같은 변압기의 감시$\cdot$진단센서 기술과 IT(정보기술)를 이용한 IT화 대응 변압기 유지보수지원시스템을 개발하여 공장내의 실(實)변압기에 설치, 실용성을 확인하였다. 이 시스템은 기존의 광역네트워크를 사용하여 유지보수거점에 위치하면서 원격지의 변압기 운전상태와 감시$\cdot$진단정보를 필요에 따라 액세스할 수 있도록 되어 있으며, 유지보수거점에서는 기기감시서버내의 데이터와 화면을 임의로 액세스할 수 있고 유지보수정보의 공유화와 이상검출시의 유중가스센서의 기동, 부하시 탭전환장치(LTC)의 토크파형 표시에 의한 조기대응과 이상해석$\cdot$진단정도(精度)의 향상에 효과를 발휘할 수 있다. 시스템은 변압기의 중요성, 토털코스트에 맞추어 구축된다. 이 때문에 센서, 각 장치간의 데이터 전송에 대해서는 온라인, 오프라인 및 각종 I/F를 준비하여 시스템의 선택성$\cdot$확장성을 고려토록 하고 있다. 차후 IT화 대응 유지보수지원시스템이 변압기 운전신뢰성 유지와 유지보수코스트 삭감에 효과를 발휘할 것으로 기대한다.

  • PDF

Position and swing angle control for loads of overhead cranes (천정크레인 부하의 위치 및 흔들림 제어)

  • Lee, Ho-Hoon;Cho, Sung-Kun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.2
    • /
    • pp.297-304
    • /
    • 1997
  • This paper presents a systematic design method of an anti-swing control law for overhead cranes. A velocity servo system for the trolley of a crane is designed based on the dynamics of the trolley and its load. The velocity servo system compensates for the effects of load swing on the trolley dynamics so that the velocity servo is independent of load swing. The velocity servo system is used for the design of a position servo system for the trolley via the loop shaping method. The position servo system and the swing dynamics of the load are then used to design an angle control system for load swing based on the root locus method. The combined position servo and the angle control systems constitute the overall control system. In the presence of low frequency disturbances, the proposed control law guarantees accurate position control for the trolley and fast damping for load swing. Furthermore, the performance of the proposed control law is independent of the mass of the load. Experimental results on a prototype crane show the effectiveness of the proposed anti-swing control law.

High Speed and Robust Control System with Deadbeat Disturbance Observer for 3D Eye Imaging Equipment (망막의 3차원 영상화를 위한 데드비트 외란 관측기를 가진 고속, 고강성 제어 시스템)

  • 고종선;이태훈;김영일
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.5
    • /
    • pp.418-426
    • /
    • 2003
  • To show a retina shape and thickness on the computer monitor, a laser has been used in Scanning Laser Ophthalmoscope(SLO) equipment using the traveling difference. This method requires exact synchronous control of laser traveling in optic system to show a clear 3-dimensional image of retina To obtain this image, this exact synchronism is very important for making the perfect plane scanning. In this study, a high speed and synchronous control of the galvanometer to make 3-dimensional retina image is presented. For the more, deadbeat load torque observer is added to the PI controller for compensation of the position error arisen in the high speed control. As a result, the proposed control system has a robust and precise response against the load torque variation appeared in high speed control. A stability and usefulness are verified by the computer simulation and the experiment.

Induction Motor Speed Control of MRAS-Based Load-Torque Observer (모델기준적응시스템(MRAS) 기반의 부하토크관측기를 이8한 유도전동기 속도제어)

  • Kim, E.G.;Lee, H.G.;Lee, S.H.;Oh, B.H.;Chung, C.B.;Hahm, N.G.;Jeon, K.Y.;Lee, S.H.;Han, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1004-1005
    • /
    • 2006
  • This paper investigates a speed sensorless control of induction motor. The control strategy is based on MRAS (Model Reference Adaptive System) using load-torque observer as a reference model for flux estimation. The speed response of conventional MRAS controller characteristics is affected by variations of load torque disturbance. In the proposed system, the speed control characteristics using a load-torque observer control isn't affected by a load torque disturbance. Simulation results are presented to prove the effectiveness of the adaptive sliding mode controller for the drive variable load of induction motor.

  • PDF

Design of Adaptive Controller using Switching Mode with Fuzzy inference and its application for industry Automation Facility (퍼지추론의 스위칭 특성을 이용한 적응제어기 설계 및 산업용 자동화 설비에의 응용)

  • 이형찬
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.1
    • /
    • pp.60-68
    • /
    • 1999
  • This paper deals with the tracking control problem of industrial robotic manipulators with unknown or changing dynamics. The proposed method makes use of multiple moodels and switching mechanism by fuzzy inference of the manipulator in an indirect adaptive controller architecture. The models used for the indmtification of the manipliator are identical, except for the initial estimates of the unknown inertial pararmeters of the manipulator and its load. The torque input that is applied to the joint actuators is determined at every instant by the identification model that best approximates the robot dynamics. Simulation results are also included to dermnstrate the improvement in the tracking perfermance when the proposed method is used.s used.

  • PDF

Estimation of PTC (Powertrain Cooling) Performance with Heat Rejection Rate (열방출량 (Heat Rejection Rate)을 이용한 PTC (Powertrain Cooling) 성능 추정)

  • Min, Sunki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3030-3034
    • /
    • 2015
  • It is important to consider powertrain cooling performance, when engine is applied to new vehicle. If the performance is poor, engine will be damaged by overheating. But, the development timing of engine is faster than timing of vehicle, it is difficult to test the cooling performance of new engine and vehicle. In this study the powertain cooling performance was estimated with some test and calculation data. First, the heat rejection test was conducted. From this test, the heat rejection data at required rpm and load was acquired. Second, coolant flow test was conducted. From this test coolant flow rate to radiator was measured. Then engine torque and rpm was calculated from vehicle load and speed. Vehicle load and speed was calculated from test mode. Then by comparing these data, the powertrain cooling performance was estimated.