• 제목/요약/키워드: 부하유량

검색결과 447건 처리시간 0.035초

Performance Test of 3 Port ERF Valve for Controlling Flow Rate-Direction (3 포트 ERF 밸브의 유량-방향 제어 성능 실험 -유압시스템 및 자동화 융합연구-)

  • Jang, S.C.
    • Journal of Power System Engineering
    • /
    • 제16권6호
    • /
    • pp.92-97
    • /
    • 2012
  • In this study, ER fluids were working fluid and yield shear stress of attained dispersive ER fluids made by analyzed to adapt effectively at the practical equipment like three port ER valve. In addition, movement of ER particle was observed by using a microscope the same as the strength of electric field with Bingham characteristic. Basis material was presented to develop 3 port ER-Valve by quantitatively comparing and analyzing entrance, load and outlet flow's differences of 3 port rectangular tubes. This study, after designing and producing the 3port ER-Valve, considered the characteristic of pressure drop, outlet and load flow rate by changing the strength of electric field on ER fluids flowing between electrodes.

In-Process Diagnosis of Servovalve Wear using Leakage Flow Measurement (누설 유량 계측에 의한 서보밸브 마멸의 인-프로세스 진단)

  • Kim K.H.;Han G.S.;Lee J.C.;Ham Y.B.;Kim S.D.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • 제1권2호
    • /
    • pp.1-7
    • /
    • 2004
  • In-process diagnosis is essential to achieve predictive maintenance in industrial plants. An in- process diagnosis method was proposed for hydraulic servo systems, which was based upon leakage flow measurement. Leakage due to servovalve wear was analysed and modeled mathematically far computer simulation work. The key idea of diagnosis algorithm is that when monitoring signals, such as servovalve input and load displacement are in steady states, the return-line flow of hydraulic servo systems can be regarded as null-leakage of servovalve. Virtual experiments were performed to ensure effectiveness of the proposed diagnosis method.

  • PDF

A study of the operational plans of non-point treatment facility depending on non-point source reduction scenario (비점오염원 저감시나리오에 따른 비점처리시설의 운영방안 연구)

  • Shin, Hyun-Suk;Jang, Jong-Kyung;Shon, Tae-Seok;Kim, Hong-Tae;Son, Jeong-Hwa
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 한국수자원학회 2008년도 학술발표회 논문집
    • /
    • pp.2056-2060
    • /
    • 2008
  • 도시하천의 오염원은 점오염원과 비점오염원으로 분류되어 점오염원은 하천유입 전에 차집하여 하수처리장에서 처리하는 체계가 갖추어져 있으나 전체 오염부하량의 $30%{\sim}40%$ (BOD기준)로 추정되는 비점오염원은 차집되거나 처리되지 않고 그대로 하천에 유입되고 있는 실정이다. 비점오염원은 불특정 오염원으로서 지표의 오염물질이나 합류식 하수관거의 하수가 강우에 의해 발생한 유출과 함께 하천으로 유입(CSOs)되어 우천 시에 하천을 오염시키는 가장 큰 원인이 되고 있으므로 이의 저감하기 위한 효과적인 비점오염원 관리방안이 요구된다. 본 연구에서는 대상유역인 부산광역시에 위치한 온천천 유역을 주요토구별 43개 유역으로 구분하여 SWMM(Storm Water Management Model)을 구축하였고 개별 토구에 Divider를 설치하여 일정 차집량을 초과하는 유량은 처리장으로 유입되는 것으로 모의하였다. 장치형 처리시설은 농도에 따라 일정효율을 가지고 처리시설의 임계유량을 초과하는 경우는 미처리되어 방류되는 것으로 가정하였으며 처리장으로 차집된 유량도 처리장의 시간최대 유량을 초과하는 유량은 간이처리 후 방류되는 것으로 가정하여 시나리오에 따라 모의하였다. 각 토구별로 처리시설을 설치한 경우의 처리효율과 차집비율을 증가시켜 처리장에서 일괄처리하는 경우의 처리효율을 차집비율별로 검토하여 최적의 차집비율을 검토하였다. 또한 오염원 관리측면의 면적당 축적부하량 저감과 발생량 관리측면의 토구의 차집비율 증가 및 토구에 대한 처리시설 설치비율에 따른 효율을 검토하여 처리효율, 오염원 저감 및 차집비율에 대한 상관관계를 도출하였다.

  • PDF

The out flow a property to the non-point source pollution by the discharge varation of the branch a river in the so-yang river (소양강 지류하천의 유량변동에 따른 비점오염물질 유출특성)

  • Park, Soo-Jin;Choi, Chang-Ho;Park, Jse-Kuk;Choi, Han-Kuy
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 한국수자원학회 2009년도 학술발표회 초록집
    • /
    • pp.2088-2092
    • /
    • 2009
  • 비점오염원은 면으로 분포하는 오염원으로 강우시 지표유출에 의해 유출되기 때문에 발생지점 및 발생량 추정이 어려우며, 이에 대한 처리가 어려운 실정이다. 현재 점오염원의 처리는 어는 정도 도달한 선진국에서는 비점오염원이 가장 중요한 오염원으로 대두되고 있는 실정이다. 따라서, 본 연구에서는 소양호 상류유역의 지류하천인 내린천, 인북천, 북천을 대상으로 부영영화를 일으키는 수질인자 BOD, COD, SS, T-N, T-P를 대상으로 강우량에 따른 수질농도가 변화하는 양상을 고찰하였다. 연구결과, 강우시 기간이 6월 ${\sim}$ 8월에 오염물질의 유출이 크게 발생하는 것을 알 수 있었으며, 연구지점 모두 비강우시에는 1급수의 수질상태를 보였으나, 강우시에는 3급수 이하의 수질로 악화되는 것을 알 수 있었다. 또한, 각 지류하천으로부터 유입되는 부하량을 추정하여 유역면적대비 유출량 - 오염부하량의 회귀식을 작성하였다. 끝으로, 유출량비를 이용하여 각 지류 하천의 유역면적대비 연간 총 오염유출량을 산정하였다.

  • PDF

A Study on Flow Control Logic Valve - Static Characteristics of Proportional Poppet Type Logic Valve - (유량제어 로직 밸브에 관한 연구 ( 비례 파핏형 로직 밸브의 정특성 ))

  • Lee, Il-Yeong;Jeong, Yong-Gil;O, In-Ho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • 제26권2호
    • /
    • pp.213-217
    • /
    • 1990
  • This study suggests a new type flow control logic valve which have grooves on the main poppet valve. The grooves connect oil supply port to pilot chamber and the oil passages made by the grooves are designed to vary in proportion to the displacement of the main poppet valve. From analytical formulations on the hydraulic circuit including the flow control valve, equations on the characteristics of the valve were obtained. In the experiment, the relationships between valve displacement and flow rate to the load side, and the variations of flow rate to the load side according to the variation of load pressure were investigated. From the experimental and numerical results, it was ascertained that the flow control valve designed in this study had excellent characteristics on proportional control and remote control.

  • PDF

Modeling of Discharge Characteristics of Combined Sewer Overflows(CSOs) from a Small Urban Watershed in Daejeon City (대전광역시 소유역에서 합류식 하수관거 월류수(CSOs)의 배출특성 모델링)

  • Kim, Jeong-Kon;Ko, Ick-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제28권6호
    • /
    • pp.654-660
    • /
    • 2006
  • This study investigated the discharge characteristics of combined sewer overflows(CSOs) at a small watershed located in the Ojeong-cheon area of the Daejeon-cheon, Daejeon City. The long-term variations of discharges, water quality, and SS loads from 2001 to 2004 were simulated using SWMM. The simulation results indicated that suspended solid(SS) loads during the rainy seasons(July${\sim}$August) were highest throughout the whole year, but not substantially higher than those during the dry seasons. This result is due to the fact that contaminants do not buildup significantly because of frequent rainfall events during the wet seasons. It was estimated that about 9.3% of SS was discharged to the receiving body the during dry seasons while 90.7% during the rainy seasons. Further analysis showed that during the wet seasons SS loads discharged at the site as CSOs and at the wastewater treatment plant without treatment were 38% and 62%, respectively.

Runoff Characteristics of Non-point Source Pollutants in Cherry Tree cultivation zone (벚나무재배지의 비점오염물질 유출특성)

  • Park, Woon Ji;Lee, Hae Seung;Hwang, Soon Hong;Lee, Young Joon;Choi, Joong Dae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.401-401
    • /
    • 2015
  • 본 연구에서는 기타재배지(벚나무재배지)에서 발생하는 비점오염물질 유출 및 수질특성을 살펴보고자 2014년 5월부터 9월까지의 총 12회의 강우사상에 대해 유출특성을 분석하고 오염물질별 유량가중평균농도(Event Mean Concentration, EMC) 및 오염부하를 산정하였다. 모니터링 기간동안 2.6~95.8 mm의 강우가 발생하였으며, 조사된 총 12회의 event 중 단 2회 유출이 발생하였다. 강우강도는 0.33~5.28 mm/hr의 범위로 나타났으며, 선행무강우일수는 0.6~21.2일, 총 유출량은 $0.92{\sim}20.75m^3$, 유출율은 0.03~0.18의 범위로 나타났다. 강우모니터링 결과, EMC는 TOC 3.4~10.3 mg/L(평균 6.9 mg/L), BOD 6.3~6.9 mg/L(평균 6.6 mg/L), COD 22.0~28.8 mg/L(평균 25.4 mg/L), SS 101.8~962.8 mg/L(평균 532.3 mg/L), T-N 4.295~11.864 mg/L(평균 8.080 mg/L) 그리고 T-P 1.109~1.582 mg/L(평균 1.346 mg/L)의 범위로 나타났으며, 각 강우사상에 대한 단위면적당 오염부하는 TOC 0.08~0.58 kg/ha, BOD5 0.05~1.07kg/ha, CODMn 0.22~3.76 kg/ha, SS 0.77~164.4 kg/ha, T-N 0.090~0.734 kg/ha, T-P 0.008~0.270 kg/ha의 범위로 산정되었다. 벚나무재배지의 수질 항목간 Pearson 상관계수를 분석한 결과, 항목 중 $COD_{Mn}$가 다른 수질항목과 유의성을 갖고 높은 상관관계가 나타나 초기유출효과 분석을 위한 대표 수질항목으로 선정하였다. 벚나무재배지의 경우 초기유출 발생에 의한 오염부하의 급격한 증가는 나타나지 않았으며, 누적오염부하량비의 그래프에서는 대부분의 강우사상에서 기울기가 직선에 가깝게 나타났다. 기타재배지의 경우 대부분 투수지역으로 초기세척효과가 비교적 작은 것으로 나타났으며, 지속적으로 오염물질을 배출하는 특성을 보이는 것으로 분석되었다.

  • PDF

EMCs and Characteristics of NPS Runoff from the Upper Watershed of Chungmi River (청미천 상류 유역의 비점유출 특성 분석 및 EMC 산정)

  • Jun, Sang Min;Kang, Moon Seong;Song, Inhong;Park, Jihoon;Song, Jung Hun;Kim, Kyeung;Ryu, Jeong Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.561-561
    • /
    • 2015
  • 비점오염원은 불특정 장소에서 불특정하게 수질오염물질을 배출하는 배출원을 의미한다. 비점오염원은 주로 강우에 의해 하천에 유입되며, 토지이용별로 다른 유출특성을 가지는 것으로 알려져 있다. 환경부에서는 토지이용별 비점오염 유출 특성을 파악하기 위하여 단일토지피복에 대한 모니터링을 오랜 기간 실시하고 있다. 하지만 복합토지피복 유역에서 각 토지이용의 비점오염 기여 특성에 관한 연구는 부족한 실정이다. 따라서 본 연구에서는 복합토지피복 유역을 대상으로 비점유출 모니터링을 실시하고, 유량가중평균농도 (EMC) 등을 활용해 토지이용에 따른 비점오염원의 유출 특성을 분석하고자 한다. 연구대상지로는 청미천 상류 유역을 선정하였고, 상류에서 하류 방향으로 4개 지점을 모니터링 지점으로 선정하였다. 유역 특성 파악을 위해 GIS를 이용하여 모니터링 지점별 집수구역의 토지이용을 분석하였고, 통계자료를 통해 주거, 축산 등의 유역현황 자료를 구축하였다. 또한 원단위를 이용하여 모니터링 지점별 배출부하량을 산정하였다. 각 모니터링 지점에서 유량 및 수질모니터링을 실시하였으며, 분석된 자료를 바탕으로 BOD, T-N, T-P의 강우사상별 EMC 및 유출부하량을 계산하였다. 모니터링 지점별 EMC는 각 집수구역의 토지이용과 비교하여 분석하였고, 유출부하량은 유역의 토지이용 및 원단위를 이용해 산정한 배출부하량과 비교하여 청미천 상류 유역의 토지이용에 따른 비점오염원 유출 특성을 분석하였다. 본 연구에서 제시한 방법은 복합토지이용유역에서의 토지이용별 비점유출 영향 분석 및 저감 대책 수립의 기초자료로 사용될 수 있을 것으로 기대된다.

  • PDF

Runoff Characteristics of Non-point Source Pollutants by Rainfall : Case Study with Pappy Field (강우시 비점오염물질의 유출 특성: 논을 대상으로)

  • Ju, So Hee;Park, Woon Ji;Shin, Jae Young;Lee, Su In;Choi, Joong Dae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 한국수자원학회 2016년도 학술발표회
    • /
    • pp.552-552
    • /
    • 2016
  • 논의 경우 다양한 영향인자에 의해 비점오염물질이 배출되기 때문에 유출특성을 파악하기가 어렵다. 따라서 본 연구의 목적은 논에서 발생하는 비점오염물질의 유출 특성에 대해 파악하여 추후 효율적인 농업비점오염 관리를 위한 기초자료를 제공하는데 있다. 연구 대상지점으로 춘천시에 위치한 논 1곳(면적: $11,130m^2$)을 선정하였으며. 2014년 5월부터 9월까지 총 11회(9회 유출)의 강우 사상에 대한 오염물질별 오염부하 및 유량가중평균농도(Event Mean Concentration, EMC)를 산정하였다. 모니터링기간 동안 발생된 강우량의 범위는 2.6~95.8 mm로 나타났으며, 선행무강우일수는 0.59~21.2일, 강우강도는 0.33~5.13 mm/hr의 범위로 나타났다. 총 유출량은 $0.16{\sim}497.3m^3$, 유출율은 0.01~0.47(평균 0.24)의 범위로 나타났다. 오염물질별 EMC는 SS 17.1~55.3 mg/L(평균 31.9 mg/L), BOD 1.9~9.7 mg/L(평균 4.2 mg/L), COD 3.6~18.9 mg/L(평균 8.3 mg/L), TOC 3.4~17.4(평균 6.4 mg/L) mg/L, T-N 1.64~7.17 mg/L (평균 3.79 mg/L), T-P 0.16~1.04 mg/L(평균 0.44 mg/L)의 범위로 나타났다. 각 강우사상에 대한 단위면적당 오염부하는 SS 0.005~19.56 kg/ha, $BOD_5$ 0.001~1.70 kg/ha, $COD_{Mn}$ 0.003~3.15 kg/ha, TOC 0.002~1.81 kg/ha, T-N 0.001~0.822 kg/ha, T-P 0.00003~0.115 kg/ha의 범위로 산정되었다. 논의 경우에는 초기유출 발생에 따른 오염부하의 급격한 변화가 없었고, 누적오염부하량비의 그래프도 강우사상의 기울기가 직선에 가깝게 나타났다. 하지만 지속적으로 오염물질을 배출하는 경향과 다양한 조건에 따라 배출양상이 달라지기 때문에 효과적인 관리를 하기 위해서 장기적인 모니터링 연구가 필요할 것으로 사료된다.

  • PDF

Multi-Optimization Study of a Boiler System Using Immune Algorithms (면역 알고리즘을 이용한 보일러 시스템의 다목적 성능 최적화 연구)

  • 김동화;박진일
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 한국퍼지및지능시스템학회 2003년도 춘계 학술대회 학술발표 논문집
    • /
    • pp.177-181
    • /
    • 2003
  • PID(Proportional-Integral-Derivative)제어기는 제어악고리즘의 단순성과 실 현장에서의 강인성 등으로 산업용 보일러의 제어시스템서 주로 이용되어 왔다. 그러나 다중 루프를 가진 보일러 시스템에서는 루프간의 상호 간섭 영향 등으로 부하 변화에 따라 요구되는 증기(steam)압력, 증기 유량(steam flow)변화 등을 동시에 만족하도록 급수 유량, 연교 유량, 공기 유량 등을 PlH제어기만으로 제어하는 것은 어렵다. 본 연구에서는 보일러 시스템의 다목적 성능 최적화에 각각의 적합도 함수 $f_{a}$ , $f_{b}$, $f_{c}$를 정의하고 면역 알고리즘을 이용해 최적화를 구하고 그 결과에 대한 특성과 유효성을 검토하였다.다.다.

  • PDF