• Title/Summary/Keyword: 부착 실험

Search Result 2,845, Processing Time 0.026 seconds

Bond Characteristics of High-Strength Light-Weight Concrete (고강도 경량 콘크리트의 부착특성)

  • Shin, Sung-Woo;Lee, Kwang-Soo;Choi, Myung-Shin;Kim, Hyun-Sik
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.77-84
    • /
    • 1999
  • Recently, it is increased the use of High-Strength Light-Weight Concrete(HLC) in the high-rise buildings and mega-structures. But there are a few research on the bond behavior of HLC, so it need to study about that. The present study was performed to investigate the bond characteristics of HLC. Major test variables include concrete compressive strength(f'c), concrete cover(c), bond length (${\ell}_{db}$), and bar diameter($d_b$). Test results indicate that the bond stress of HLC is increased with the increment of $\sqrt{f'_c}$ and concrete cover, bond stress is decreased with increment of bond length and bar diameter. And the final failure mode such as splitting or pullout failure is significantly affected by the concrete cover to bar diameter ratios(C/$d_b$). Test results were compared with ACI code and other proposed equations. The bond stress of HLC is higher than that of normal-strength normal-weight concrete, but lower than that of high-strength normal-weight concrte. Considering the present test results, modification factor(${\lambda}$= 1.3) of bond length in ACI 318-95 code for light-weight concrete is may have to be reviewed to apply to HLC.

Basic Performance Evaluation of a Tack Coat Material for Use with a Spray Paver (동시포설 공법을 위한 택코트 재료의 기초 성능 평가 연구)

  • Jo, Shinheang;Kim, Kyungnam;Cui, Wenhui;Kim, Nakseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.737-744
    • /
    • 2021
  • Spray paving minimizes material lost during the construction or repair of a road surface, and it can be done in conjunction with tack coating. This approach involves applying the asphalt mixture at the same time as spraying the tack coat by attaching a spraying device to the asphalt paver. When applying an asphalt overlay to an aged concrete surface, it is important to ensure the adhesion performance between different material properties. Accordingly, there is a need for a tack coat that can be applied by spray paving and that exhibits good adhesive performance on different materials. In this study, bonding strength tests under various conditions were performed to evaluate the basic performance of a tack coat developed for use with a spray paver. The bonding performance of the tack coat was observed to be affected by curing conditions and material lost during construction. The test results also showed that the tensile and shear bonding strengths of the developed tack coat were 1.21 and 1.99 times higher than those of a conventional one, respectively. As a result, the developed tack coat is considered suitable for application to spray paving.

Blood Property and Biologger Attachment Efficiency of Spotted Sea bass Lateolabrax maculatus depending on External Biologger Attachment Methods (바이오로거 체외 부착방법이 점농어(Lateolabrax maculatus)의 혈액성상 및 바이오로거 부착효율에 미치는 영향)

  • Pil Jun Kang;Geun Su Lee;Sung-Yong Oh
    • Journal of Marine Life Science
    • /
    • v.9 no.1
    • /
    • pp.22-32
    • /
    • 2024
  • The purpose of this study was to determine the effect of external biologger attachment methods on the blood parameters and attachment efficiency of spotted sea bass Lateolabrax maculatus (mean body weight 2630.8 g). The fish were tagged using four different external attachment methods with dummy biologgers: no attachment (control), anchor attachment (AA), monofilament attachment (MA), and silicon tube attachment (SA), each with triplicates. Blood indices and biologger attachment efficiency were assessed on days 1, 7, 14, 28, 56, and 84 after attachment. The concentrations of hematocrit, Na+, Cl-, glutamic pyruvic transaminase and total protein, and the activity of superoxide dismutase in blood were not affected by the external attachment method of biologger. The concentrations of glutamic oxaloacetic transaminase (day 1 of attachment), hemoglobin (day 56) and total cholesterol (day 56 and 84) in AA group, the concentrations of glucose and cortisol (day 14) and total cholesterol (day 84) in MA group showed significantly higher than those of control (p<0.05). During the experiment period, the SA group had no differences from the control in all blood properties. The biologger attachment efficiencies of the AA, MA, and SA groups after 84 days were 0.0%, 33.3%, and 100.0%, respectively. These results indicate that the optimum external biologger attachment method under our experimental conditions is SA type.

Bond Characteristics of Ultra High Performance Concrete (초고성능 콘크리트(UHPC)의 부착특성에 관한 연구)

  • Kook, Kyung-Hun;Shin, Hyun-Oh;Kwahk, Im-Jong;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.6
    • /
    • pp.753-760
    • /
    • 2010
  • Ultra high performance concrete (UHPC), is characterized by its high compressive strength and advanced tensile behavior that is much superior to those of conventional concrete. In order to apply this new material in practice, the bond characteristics of UHPC were evaluated in this study. Pull-out tests between UHPC and deformed steel rebar were carried out according to the modified RILEM test method, and were verified by finite element analysis. From the test results showed that UHPC presents 5 to 10 times higher bond strength compared to normal strength concrete, this study suggested remarkably reduced development length and concrete cover comparing to existing specifications. The test results of 700 MPa high strength steel rebar demonstrated the applicability of high strength steel to UHPC. In addition, the transfer length measurements of seven-wire strand in UHPC specimens indicated that the transfer length limit set by the current design code is very conservative for UHPC.

Behaviors of Concrete Segmented Composites Using Polymer Mortar Under Static and Impact Loadings (폴리머 모르타르를 이용한 콘크리트 분절 복합체의 정하중 및 충격하중에서의 거동 평가)

  • Min, Kyung Hwan;Lee, Jin Young;Kim, Mi Hye;Yoon, Young Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.5
    • /
    • pp.169-177
    • /
    • 2011
  • In this study, an impact resistance of concrete segmented composites adopted shell's structures which have the excellent impact resistance was assessed. In order to enhance the performances of concrete segmented composite, the bond strength of mortar between the concrete blocks should be improved. Hence, in this study polymer mortars were applied to increase the bond strength of mortar. From the results of bond tests, the 15% latex mortar was selected and static and low-velocity impact tests were carried out for the specimens applied the plain and latex mortar. The concrete segmented composites, of which the bond strength of mortar was enhanced, showed improved low-velocity impact resistances. A Nonlinear finite element analysis using the discrete crack model showed similar energy dissipating capacities to the impact test's results. Consequently, by improving the analysis models for segmented composites, the impact resistances for manifold variables can be predicted and assessed.

The Development of Rotoless Electronic Circulating Pump System with Internal Three Way Valve for Boiler - Objective for the 1st Year : Development of New Housing with Internal Three Way Valve - (보일러용 3way valve내장형 rotoless 전자식순환펌프 시스템의 개발 - 1차년도 목표 : 3way valve 내장형 하우징의 개발 -)

  • Han, J.W.;Kum, S.M.;Ryu, B.H.;Lee, C.E.;Ohu, S.C.;Yim, J.S.
    • Solar Energy
    • /
    • v.16 no.2
    • /
    • pp.97-112
    • /
    • 1996
  • The purpose of research is to complement the circulating pump of gas boiler for the domestic and to develop a pump housing with internal three way valve: Housing and three way valve have been apart in the existing pump system. Based on the experimental result on can-typed circulating pump with existing housing, a new housing with internal three way valve was designed and manufactured. The performance of can-typed circulating pump with the new housing, and the performance of circulating pump of boiler system were tested. As a result ot the test, the new housing with internal three way valve has been excellent in respect of pump performance, weight and manufacturing cost. So It is expected to have an effect of import substitution.

  • PDF

Spectral Element Analysis for the Electro-Mechanical Admittance of a Piezoelectric Wafer Bonded on a Plate (판구조물에 부착된 압전소자의 전기역학적 어드미턴스 스펙트럼 요소 해석)

  • Kim, Eun-Jin;Shon, Sohn;Park, Hyun-Woo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.239-242
    • /
    • 2009
  • 구조물의 표면에 부착된 압전소자(이하 PZT)의 전기역학적 어드미턴스(Electro-mechanical admittance)는 PZT와 구조물의 상호작용에 의해 발생하는 PZT의 압전효과와 유전성(dielectric)이 결합되어 발생되는 신호이다. 고주파수 대역에서 PZT의 전기역학적 어드미턴스는 구조물의 국부손상에 민감하게 반응하는 것으로 알려져 있다. 실험에서 측정된 PZT의 전기역학적 어드미턴스 분석에 널리 쓰이는 Liang 모델은 구조물을 단자유도계로 단순화하여 구조물의 동적특성이 전기역학적 어드미턴스에 미치는 영향을 정확하게 나타내기 어렵다. 유한요소법을 통해 PZT와 구조물의 상호작용을 해석하면 이러한 문제점을 해결할 수 있다. 그러나 고주파 대역에서 정확한 해석을 위해서는 유한요소망을 조밀하게 구성해야 하므로 많은 계산비용이 수반된다. 이 연구에서는 유한요소법과 비교하여 월등히 적은 계산비용으로 고주파 대역의 동적 응답을 매우 정확하게 모사할 수 있는 스펙트럼 요소법(Spectral Element Method ; 이하 SEM)을 통해 판구조물에 부착된 PZT의 전기-역학적 어드미턴스를 해석한다. 수치 예제 및 실험 예제를 통하여 내민보에 부착된 PZT에서 발생하는 전기-역학적 어드미턴스를 취득하고 이를 SEM해석 결과와 비교한다.

  • PDF

FE Analysis of RC Beams Strengthened with Carbon Fiber Sheet (탄소섬유쉬트로 보강된 RC 보의 유한요소해석)

  • 한상호;이경동
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.16 no.1
    • /
    • pp.53-58
    • /
    • 2003
  • Carbon fiber sheet has been used to rehabilitate many types of reinforced concrete members with its superior characteristics such as their lightweight, high strength, corrosion resistance, and easy execution. But the failure behavior of reinforced concrete members show a high variation by the bond characteristics between carbon fiber sheet and concrete surface. In this study, a bond stress-slip model, which accounts for changes in bonding behavior between concrete and carbon fiber sheet with some link elements, is proposed. The link elements are used to represent the concrete-carbon fiber sheet interface. To investigate the efficiency of this method, the analytical solutions for the behavior of reinforced concrete beam strengthened with carbon fiber sheet are compared with experimental ones. Results from the proposed model comparatively well agree with the experimental results.

Adhesion of Escherichia coli to Quartz and Iron-coated Sands in the Presence of Phosphate (인산염의 존재 하에서 Escherichia coli의 석영 및 철피복 모래에의 부착)

  • Park, Seong-Jik;Lee, Chang-Gu;Kim, Hyon-Chong;Han, Yong-Un;Kim, Song-Bae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.6
    • /
    • pp.616-620
    • /
    • 2008
  • The aim of this study was to investigate the influence of phosphate on the adhesion of Escherichia coli to porous media. Column experiments were performed to examine the effect of phosphate on bacterial adhesion to quartz sand and iron-coated sand. Results showed that bacterial mass recovery in quartz sand decreased from 74.5 to 35.4% as phosphate concentration increased from 0 to 16 mg/L. This indicated that bacterial adhesion to quartz sand was enhanced with increasing phosphate concentration. This phenomenon is due to the increase of ionic strength. In contrast, the mass recovery in the coated sand increased from 2.9 to 26.0% as phosphate concentration increased. This indicated that bacterial adhesion to the coated sand was reduced with increasing phosphate concentration, due to the preoccupation of favorable adsorption sites and competitive adsorption by phosphate.