• Title/Summary/Keyword: 부착 강도

Search Result 1,417, Processing Time 0.028 seconds

Effect of Shear Key and Edge Length of Near Surface-Mounted FRP Plate in Concrete (콘크리트에 표면매입 보강된 FRP판의 전단키 및 연단거리 효과)

  • Seo, Soo-Yeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.1
    • /
    • pp.41-47
    • /
    • 2016
  • This paper presents a bond test to find the effect of shear key and edge length from the bonded FRP in near surface-mounted(NSM) retrofit using FRP plate. Main parameters in the test are the location and size of shear key and the edge length. For the test, 10 specimens were made by embedding FRP plate of $3.6mm{\times}16mm$ into $400mm{\times}200(300)mm{\times}400mm$ concrete block and fixing it by using epoxy. Tensile load was applied to the FRP of the specimens until failure and was recorded at each load increase. In addition, the bond slip and elongation of FRP were measured during the test. From the test, it was found that the further the shear key located from the loading, the higher strength we could get. The bond strength inversely depended on the size of shear key. Especially, when the size of shear key was to be lagger than certain size, the bond strength decreased to very low value; even less than that of the case without shear key. The bond strength somewhat increased corresponding to the increase of edge length from the bonded end of FRP to loading in spite of same bond length. The bond-slip between FRP and concrete governed overall deformation in the bond test of NSM FRP so that the effect of excessive slip is necessary to be considered in the design.

Sensory Evaluation of Quality and Constructability of Cement Mortar for Tile Direct Setting Method Depending on Mix Proportions (타일 떠붙임 시멘트 모르타르의 배합비 변화에 따른 품질 특성 및 시공성에 대한 관능 평가)

  • Hwang, Yin-Seong;Ki, Tae-Kyoung;Han, Dong-Yeop;Noh, Sang-Kyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.1
    • /
    • pp.11-19
    • /
    • 2021
  • The aim of the research is providing a fundamental data on quality and constructability of direct tile setting method depending on various cement to sand ratio for tiling dry cement mortar. A large number of tile setting failures reported is related with the cement mortar and its construction for tiling. Because of different materials of tiles, the properties of tiling dry cement mortar, an adhesive for tiling, can influence on quality and constructability of tiling differently. Practically, the easiest way of controlling the properties of the tiling dry cement mortar is to control the proportion of cement and sand. Hence, in this research, sand to cement ratio (S/C) was controlled. Since there is no standarized method on evaluating performance of dry cement mortar for tiling, a several sensory evaluation methods were suggested and executed. According to the experiments conducted in this research, the adhesive performance of cement mortar for tiles can be different depending on the sides such as tile and substrate. Additionally, depending on S/C, finishability, initial adhesive performance, and tile shifting resistance can be changed for ceramic tile. Therefore, under the conditions of this research, about 5 of S/C can be recommended for appropriate performace of tiling dry cement mortar.

Development of High-Strength Si-Cr Spring Steel for the Engine Valve Spring (엔진 밸브 스프링에 사용되는 고강도 Si-Cr 스프링 강의 개발에 관한 연구)

  • Ban, Deok-Yeong;Nam, Won-Jong;Lee, Sang-Rae
    • Korean Journal of Materials Research
    • /
    • v.8 no.1
    • /
    • pp.64-70
    • /
    • 1998
  • 자동차의 엔진밸브 스프링으로 사용되는 Si-Cr 스프링강의 영구 변형 저항성과 내피로성이 우수한 고강도강을 개발하기 위하여 탄소함량을 증대시키고 Mo, V, W와 같은 합금원소를 기존의 SAE 9254 스프링강에 첨가하여 개발강을 제조했다. SEM및 EDX가 부착된 TEM을 이용하여 미세조직을 관찰했고, 크립시험 및 피로시험기를 이용하여 스프림의 영구 변형 저항성 및 스프링의 내피로성을 조사했다. 실험결과, 개발강은 피로 특성치는 기존강과 동등 수준이면서 인장강도가 기존강의 것보다 10%가 더높은 2100MPa 급의 고강도를 나타내었으며 또한 영구 변형 저항성도 현저하게 개선되었는데 이는 W, Mo의 첨가로 인해 템퍼링시에 세멘타이트의 성장이 억제되어서 세멘타이트의 석출물이 미세하게 되었기 때문이다.

  • PDF

Factors Influencing the Strength of Alumina Ceramic shell Molds Bound with Colloidal Silica (콜로이달 실리카로 결합된 알루미나 세라믹 쉘 몰드의 강도에 미치는 요인)

  • Gang, Jong-Bong;Mun, Jong-Su;Jo, Beom-Rae;Choe, Seung-Ju;Kim, Hak-Hak
    • Korean Journal of Materials Research
    • /
    • v.6 no.12
    • /
    • pp.1179-1185
    • /
    • 1996
  • 고온용 세라믹 쉘 몰드를 용융 알루미나와 콜로이달 실리카를 사용하여 제조한 후, 세라믹 쉘 몰드의 강도에 영향을 주는 요인을 분석하였다. 세라믹 쉘 몰드의 강도는 바인더의 실리카 입자의 크기가 작을수록 크며 또한 실리카 농도에 비례하여 증가함을 보이며 저온에서의 강도 발현은 콜로이달 실리카의 필름 형성에 의한 입자들의 결합임을 알 수 있었다. 세라믹 쉘 몰드의 소성 강도는 부착 스타코의 크기가 작을수록 크며 소성 온도에 비례하여 증가함을 보였다. 고온에서의 강도 발현은 알루미나 입자와 콜로이달 실리카 바인더의 결합뿐만 아니라 알루미나 입자사이의 결합도 영향을 줌을 알 수 있었다. 쉘 몰드의 결정상은 130$0^{\circ}C$이하에서 소성한 경우 $\alpha$-알루미나만 존재함을 보여 실리카는 비정질로 계속 남아 있음을 알 수 있고 140$0^{\circ}C$ 이상에서 소성한 경우 뮬라이트가 생성됨을 보였다.

  • PDF

Geographic Distribution of Periphyton Diatom Species: A Case Study of Achnanthes convergens in Nakdong River Basin (낙동강 수계 청수성 부착조류의 공간분포 특성에 관한 연구: Achnanthes convergens 를 사례로)

  • Jo, Myung-Hee;Byun, Myeung-Sub;Sim, Jun-Seok;Jang, Sung-Hyun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.3
    • /
    • pp.175-194
    • /
    • 2014
  • This study attempts to identify the spatial distributions of Achnanthes convergens, and elucidate the environmental factors that affect the Periphyton diatom habitat. Data in 250 points of Nakdong river basin are collected between April(primary) and September(secondary) 2012, with the National Institute of Environmental Research's support. We define "clean area" over 10% of Achnanthes convergens appearance, and the others as "non-clean areas". Spatial statistics of Kriging, Hotspot, LISA are used in this study. Results show that 1) 56 points are identified as clean areas in the primary survey, while 41 points are discovered in the following survey; 2) using water quality variables, density of turbidity(clean $101.83{\mu}s/cm$; non-clean $598.48{\mu}s/cm$) and conductivity(clean 1.95 NTU; nonclear 5.58 NTU) are five-fold lower in clean-areas; 3) Habitat and Riparian Factors in Nakdong basin illustrate that natural sand bar, diversity of velocity, sediment condition, levee material, riverside land affect Achnanthes convergens; 4) Hotspots of Achnanthes convergens are located in watersheds, including upper Andong Dam, upper Imha dam, Wi-cheon, Miryang river, Nam river and Hwang river whereas mainstream/downstream of Nakdong river and Keumho river watershed are shown as coldspots.

Experimental Study on Bond Behavior of Retrofit Materials by Bond-Shear Test (부착전단 실험에 의한 보강재료의 부착거동 실험 연구)

  • Ha, Ju-Hyung;Yi, Na-Hyun;Cho, Yun-Gu;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.1
    • /
    • pp.45-52
    • /
    • 2012
  • A variety of retrofit material such as CFRP, GFRP, and PolyUrea have been developed for strengthening RC structures and infrastructures. From previously reported research results, the capacity of strengthened concrete structures was dictated by the behavior of the interface between retrofit material and concrete. In this study, bond-shear test was carried out to estimate the bond behavior between retrofit material and concrete using a newly developed test grip. The test results of load and slip relation and energy absorption capacity of each retrofit material were obtained. These test results will provide basic information for retrofit material selection to achieve target retrofit performance.

Effect of Bond Action of Longitudinal Bars on Shear Transfer Mechanism in RC Beams (RC 보에서의 전단저항기구와 주철근의 부착 작용과의 관계)

  • Kim Kil-Hee
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.4 s.88
    • /
    • pp.513-520
    • /
    • 2005
  • The uniform truss mechanism is widely accepted as a shear transfer mechanism in reinforced concrete members. However, the uniform truss action cannot be expected when the bond stress distribution is not constant along longitudinal bars. A test method in which only the truss action takes place is developed and conducted to investigate the truss actions under various bond contributions. Based on the experimental results and analysis, the following findings can be obtained: 1) The bond stress distribution depends on the axial compression force, the amount of shear reinforcement and loading conditions. 2) The analysis using the combined truss model consisting of uniform and fan-shape trusses can predict the experimental results

Nonlinear FE Analysis of RC Shear Walls (철근콘크리트 전단벽의 비선형 유한요소해석)

  • 곽효경;김도연
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.12 no.3
    • /
    • pp.293-308
    • /
    • 1999
  • 이 논문에서는 패널, 깊은 보 그리고 전단벽과 같이 평면응력상태하에 있는 철근콘크리트 구조물의 비선형 유한요소해석에 있어서의 직교이방성 콘크리트 구성 모델의 적용성을 보여준다. 등가의 일축 변형을 개념을 토대로 콘크리트의 구성 관계가 주변형률 축과 일치하고 하중이력에 따라 회전하는 직교하는 축에 대해 제시된다. 제안된 모델은 이축 압축응력상태와 인장-압축 응력상태에서 각각 압축강도의 증가와 인장 저항력의 감소효과를 보여주는 이축 파괴영역의 정의를 포함한다. 인장균열이 발생한 후, 콘크리트의 압축강도의 감소효과가 제시되고, 인장강화효과로 알려진 철근에 의해 지지되는 콘크리트의 인장응력이 고려된다. 평균응력과 평균변형률 개념을 사용하여 힘의 평형, 적합조건 그리고 철근과 철근을 둘러싼 콘크리트 사이의 부착응력-슬림 관계를 토대로 인장강화효과를 모사하기 위한 모델이 제안된다. 유한요소 모델에 의한 예측은 유용한 실험자료와의 비교에 의해 입증된다. 이 논문에서는 해석결과와 이상화한 전단 패널실험으로부터 얻어진 실험값의 비교연구가 수행되고, 제안된 모델의 타당성을 보여주기 위해 서로 다른 응력상태하의 전단 패널 보와 벽체의 힘-변위 관계를 평가하였다.

  • PDF

Proposal of Bond Strength Evaluation Method for Overlay Concrete at Field (유한요소해석을 이용한 현장 덧씌우기 콘크리트의 부착강도 평가 방법 제안)

  • Lee, Bong-Hak;Hong, chang-Woo;Lee, Joo-Hyung;Kim, Seong-Hwan
    • Journal of Industrial Technology
    • /
    • v.21 no.B
    • /
    • pp.295-300
    • /
    • 2001
  • Significant improvements in bond strength between new and existing concrete can be achieved through the modification of the new concrete by latex modification. But, no test method has been adopted as a standard to measure the bond strength between the concrete used to repair and the substrate being repaired. The performance of old and the new concrete construction defends upon band strength between old and the new concrete. Current adhesion strength measurement method is inaccurate method that ignore effect of stress concentration by shape of specimens. Therefore, this research calculates stress concentration coefficient using finite element analysis and direction tensile strength test (pull-off test). The result shows that the required core depth is 2.5 cm. Elastic modulus and overlay thickness do not influence in stress concentration.

  • PDF

Proposal of Bond Strength Evaluation Method for Bridge Deck Overlay (교면 덧씌우기 콘크리트의 부착강도 평가 방법 제안)

  • 장흥균;홍창우;정원경;이봉학;윤경구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.349-354
    • /
    • 2002
  • Significant improvements in bond strength between new and existing concrete can be achieved through the modification of the new concrete by latex modification. But, no test method has been adopted as a standard to measure the bond strength between the concrete used to repair and the substrate being repaired. The performance of old and the new concrete construction depends upon bond strength between old and the new concrete. Current adhesion strength measurement method ignores the effect of stress concentration by shape of specimens. Therefore, this research calculates stress concentration coefficient using finite element analysis and direction tensile strength test (pull-off test). The result shows that the required core depth is 2.5cm. Elastic modulus and overlay thickness do not influence in stress concentration.

  • PDF