• Title/Summary/Keyword: 부착 강도

Search Result 1,415, Processing Time 0.031 seconds

Behavior of 550MPa 43mm Hooked Bars Embedded in Beam-Column Joints (보-기둥 접합부에 정착된 550 MPa 43 mm 갈고리철근의 거동)

  • Bae, Min-Seo;Chun, Sung-chul;Kim, Mun-Gil
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.5
    • /
    • pp.611-620
    • /
    • 2016
  • In the construction of nuclear power plants, only 420 MPa reinforcing bars are allowed and, therefore, so many large-diameter bars are placed, which results in steel congestion. Consequently, re-bar works are difficult and the quality of RC structures may be deteriorated. To solve the steel congestion, 550 MPa bars are necessary. Among many items for verifying structural performance of reinforced concrete with 550 MPa bars, the 43 mm hooked bars are examined in this study. All specimens failed by side-face blowout and the side cover explosively spalled at maximum loads. The bar force was initially transferred to the concrete primarily by bond along a straight portion. At the one third of maximum load, the bond reached a peak capacity and began to decline, while the hook bearing component rose rapidly. At failure, most load was resisted by the hook bearing. For confined specimens with hoops, the average value of test-to-prediction ratios by KCI code is 1.45. The modification factor of confining reinforcement which was not allowed for larger than 35 mm bars can be applied to 43 mm hooked bars. For specimens with 70 MPa concrete, the average value of test-to-prediction ratios by KCI code is 1.0 which is less than the values of the other specimens. The effects of concrete compressive strength should be reduced. An equation to predict anchorage capacity of hooked bars was developed from regression analysis including the effects of compressive strength of concrete, embedment length, side cover thickness, and transverse reinforcement index.

Evaluation of Fatigue Strength Share Effect of the Rust Due to Corrosion at Ship Structural Plate (선체구조 판부재에서 해수부식현상에 기인하는 부식층의 피로강도분담효과에 관한 연구)

  • Kim, Won Beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2063-2068
    • /
    • 2013
  • Ship and offshore structures, those are to be used under the seawater conditions are prone to corrosion. In this research, the effect of rust existence on the fatigue strength at structural member of ship and offshore structure was investigated. For this purpose, fatigue tests for the rust removed specimen were conducted. In addition, the comparison of fatigue strength between rust removed specimen and rusted specimen was conducted. With these test results, fatigue strength share effect was investigated. Finally, at this research, it was found that there is fatigue strength share effect on the rust. In comparison of fatigue strength reduction factor, fatigue strength of the rust removed specimen is 18.1% lower than that of the rusted specimen. From the above, it was known that as far as there are not any harmful ingredients in it, rust on the steel plate is beneficial in an aspect of fatigue strength.

Properties of Advanced Synthetic Fiber Reinforced Concrete for Improvement of Tunnel Shotcrete Performance (터널 숏크리트 성능 향상을 위한 고기능성 합성섬유 보강 콘크리트의 물성 평가)

  • Jeon, Chanki;Jeon, Joongkyu
    • Journal of the Society of Disaster Information
    • /
    • v.7 no.1
    • /
    • pp.43-50
    • /
    • 2011
  • The Application of Steel Fiber Shotcrete in tunneling construction has become part of tunneling practice at least since the 1970s because of its high bending and tensile properties. Over the past 3 decades, researcher from all over the world have been significantly developing the associated technologies for improved performance of SFRS. But still it has some major drawbacks in terms of durability, damage of pumping hose, wastage due to rebound concrete, corrosion and it costs high. To overcome this situation researcher has to look for some alternative material. Therefore, this part study deals with the three types of fiber in order to find good alternative for steel fiber. Polyamide and Polypropylene fiber were used in this study with 0.6, 0.5% mixing ratio. To evaluate its fresh and harden properties air content, slump, compressive, split tensile and bending strength were measured. After comparing the results of all three types of fiber reinforced concrete with its different mixing proportion this study propose that polyamide fiber with addition ratio of 0.6 % for field use.

Mechanical Properties of External Thermal Insulation Composite System with Quasi-Non-Combustible Performance (준불연 외단열시스템의 역학적 특성에 관한 연구)

  • Choi, Ki-Sun;Ha, Soo-Kyung;Oh, Keun-Yeong;Park, Keum-Sung;Ryu, Hwa-Sung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.5
    • /
    • pp.507-518
    • /
    • 2021
  • The application of an adhesive calcium carbonate-based hybrid insulation board with quasi-combustibility in the external thermal insulation composite system(ETICS) ensures effective thermal performance and fire safety. This study aimed to conduct a mechanical test of the quasi-non-combustible hybrid insulation board as well as its constituent materials to obtain the basic data for the structural design of the adhesive ETICS. Test specimens were fabricated based on domestic and foreign test standards to examine and evaluate their tensile, compressive, flexural, and shear strengths. The strength characteristics of the quasi-non-combustible hybrid insulation board were identified from the test results, which verified that the minimum required physical properties suggested by the current KS M ISO 4898 were met. Furthermore, the quasi-non-combustible ETICS used in this study was found to be suitable for use as an external insulation system for walls unless subjected to continuous gravity load, such as a heavy exterior finish.

Deterioration Characteristic of Shotcrete Immersed in Chemical Solution (화학적 침식에 의한 숏크리트의 열화특성 분석 - 단기거동)

  • Lee, Gyu-Phil;Kim, Dong-Gyou;Bae, Gyu-Jin;Shin, Hyu-Soung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.7 no.2
    • /
    • pp.143-152
    • /
    • 2005
  • Shotcrete for support of tunnel structures may contact with groundwater. The hazardous components in groundwater may cause corrosion of shotcrete. Also, the hazardous components may deteriorate the engineering properties of shotcrete, such as compressive strength, bond strength, flexural strength and so forth. The more the effect of the hazardous components on the shotcrete may increase, the more the stability of tunnel structure may decrease. The specimens were artificially immersed in various chemical solutions including hazardous components after the specimens were made at the tunnel construction site. It was performed to analyze the effect of the hazardous components in ground water on the engineering properties of shotcrete. The uniaxial compressive strength test, XRD, SEM were conducted to evaluate the durability and corrosion of shotcrete.

  • PDF

Determination of Steel-Concrete Interface Parameters : Bonded and Unbonded Slip Tests (강-콘크리트 계면의 계면상수 결정 : 부착 및 비부착 슬립실험)

  • Lee, Ta;Joo, Young-Tae;Lee, Yong-Hak
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.6
    • /
    • pp.773-780
    • /
    • 2009
  • Experiments on steel-concrete interface are performed to investigate and determine the mechanical roles and properties of interface parameters. The intrinsic different nature of bonded and unbonded interfaces are addressed based on the experimental observations that were obtained from two types of tests considering bonded and unbonded interfaces. The unbonded tests are performed for the specimens that are in unbonded when the initially bonded specimens are tested first. Four cases of lateral confinements including pure slip, and low and medium levels of lateral pressure are taken into account to investigate the effects of lateral confinements on interface behavior. It is shown that the maximum shear strengths, the levels of residual strengths and the Mode II fracture energy release rates are linearly related to the confinement levels. Based on the experimental evidences obtained from this study, the values of interface parameters required in a steel-concrete interface constitutive model will be presented in the companion paper.

Experimental Examination of Influential Variables on Unbonded Tendon Stresses (비부착 긴장재의 응력에 영향을 미치는 중요변수에 대한 실험연구)

  • Lim, Jae-Hyung;Moon, Jeong-Ho;Lee, Li-Hyung
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.1
    • /
    • pp.209-219
    • /
    • 1999
  • This paper describes an experimental study planned to examine the effects of important design variables which were used in the proposed equation by authors. Fourteen beams and slabs were designed with the variables, such as effective prestress, concrete strength, amount of tendons, amount of bonded reinforcements, loading type, and span/depth ratio. Then, deflections and tendon stresses were measured and compared according to the parametric variations of the selected variables. It was found that the tendon stress increment decreases as the level of effective prestress or the amount of unbonded tendons and bonded reinforcements increases. Also, the contributions of concrete strength, and loading type were observed to affect on the tendon stresses. However, the stress increments of unbonded tendon were minimal alt high values of span/depth in contrast with the ACI code.

Evaluation of Mechanical and Durability Performance of Mortar Shotcrete (모르타르 숏크리트의 역학성능 및 내구성능 평가)

  • Park, Byoungsun;Jang, Kun Young;Choi, Young Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.5
    • /
    • pp.68-74
    • /
    • 2019
  • In this study, the mechanical property and durability of improved bond performance mortar shotcrete was investigated. Mortar shotcrete was prepared by replacing coarse aggregate with 100% fine aggregate in the shotcrete mixture proportion proposed in the road construction standard specification. OPC, GGBFS and anhydrite were used as binders, and polymer powder was substituted for 1% and 2% of binder for improving bond property. From the experimental results, it was found that the compressive strength decreased with increasing polymer addition, but the bond strength increased. The addition of polymer to mortar shotcrete also reduced the drying shrinkage and improved the resistance to carbonation. Initial hydration heat of mortar shotcrete decreased with the addition of polymer, and it was judged that the initial compressive strength decreased.

Development of Domestic Pattern Frame Method for Skid Resistance Pavement (미끄럼 방지 도로 포장을 위한 국내형 패턴 프레임 공법 개발)

  • Lee, TaeMin;Choi, HaJin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.2
    • /
    • pp.58-65
    • /
    • 2021
  • As increasing social needs of pavement maintenance, pattern frame method has been constructed in Korea. The pattern frame not only increases the skid resistance of pavements but also improve the scenery. However, construction of the pattern frame currently relies on imported materials. In this paper, we localize the materials used in pattern frame and conduct performance verification on them. The important performance indicators are the adhesion strength of undercoating materials and the skid resistance of finished pattern frames. The adhesion strength was targeted at 1.4MPa, and the localization alternative material met the target performance with 2.35MPa, the skid resistance performance was targeted at 40BPN, and the localization alternative material met the target performance with 75BPN. In the case of localized materials, approximately 40% cost reduction (per 1m2)compared to imported materials was confirmed.

Studies on the Adhesion of W to TiN(II) (TiN에 대한 W의 부착특성에 관한 연구(II))

  • Lee, Jong-Mu;Gwon, Nan-Yeong;Lee, Jong-Gil
    • Korean Journal of Materials Research
    • /
    • v.3 no.6
    • /
    • pp.593-597
    • /
    • 1993
  • Adhesion of CVD W to the TiN glue layer in the blanket W process which is a promising candidate for filing contact holes in subhalfmicron ULSIs has been investigated. The adhesion was enhanced with increasing the W film thickness due to the decrease of the TiN film stress. The adhesion strength was increased by the sputter etching of the TiN surface prior to the W deposition owing to the removal of contaminants and the increase of the surface roughness. The adhesion of the W film to the TiN glue layer property was also improved by Ar ion implantation of the TiN surface owing to the activation of the TiN surface.

  • PDF