• Title/Summary/Keyword: 부식 억제효과

Search Result 92, Processing Time 0.024 seconds

Corrosion Stability of Iron Artifacts after Treating with Water Treatment (수처리제를 사용한 철제유물의 부식 안정성 연구)

  • Jeong, Ji Hae
    • Journal of Conservation Science
    • /
    • v.33 no.5
    • /
    • pp.381-390
    • /
    • 2017
  • Desalination is the main focus of the stabilization of iron artifacts. However, drawbacks such as re-corrosion are noted due to the uncertainty in the elimination of the corrosive factors and artifacts. Several studies have been carried out on the effects of corrosion inhibitors to overcome these shortcomings. In this study, the effects of type 3 water treatment on corrosion inhibitors were investigated. Surfaces of samples that contained film corrosion inhibitors on their surfaces were analyzed. The results revealed that the surface rust was removed from the sample of type 1 No. 2 that was mainly composed of phosphate. The average weight reduction rates of re-corrosion samples were 0.58, 0.03, and 0.07% for type 1 No. 2, type 2 No. 2, and type 3 No. 2 respectively. The changes in the $Cl^-$ ion, a corrosive agent were found to be 28.60, -4.08, and -1.94 ppm for type 1 No. 2, type 2 No. 2, and type 3 No. 2 respectively. The water-treated films were analyzed by X-ray photoelectron spectroscopy (XPS). It was found that type 2 No. 2 had less Fe the basis metal, than that in type 3 No. 2 indicating much better film. Moreover, Si content was higher in type 2 No. 2, based on the silicate content, than in type 3 No. 2. They are speculated to be the reason or the formation of a better film. Type 1 No. 2, which is mainly composed of phosphate, would be inappropriate as a metal artifact conservation treatment. It was determined that type 2 No. 2 and type 3 No. 2 water treatments, which are mainly composed of silicate, provided excellent corrosion inhibiting effects. Corrosion inhibitors could be used as emergency treatment agents during the excavation of iron artifacts.

해양환경 중에서 Polyester Glass Flake 라이닝 강재의 부식 억제에 관한 연구

  • 임우조;김성훈;구자점;윤대영
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2001.05a
    • /
    • pp.59-60
    • /
    • 2001
  • 산업의 발전과 함께 해양환경 중에서 사용되는 항만시설과 해양구조물 등을 비롯하여 철강재로 제작되는 각종 구조물, 공업용수배관, 열교환기, 선박 등의 기계장치나 각종설비는 그 사용 환경이 다양해지고 오염되면서 부식손상이 발생되어 지고있다. 더욱이 강전해질의 해양환경 중에서 기계적인 충격 침식과 더불어 전기화학적인 부식이 중첩하여 발생하는 경우에는 침식과 부식 이 상호간에 가속하는 상승효과 때문에 각종 기계장치 및 설비의 수명에 대한 안정성 확보가 어렵다. (중략)

  • PDF

Coating formation of water supply pipes by inhibitor and water quality improvement effect (부식억제제에 의한 상수도관의 피막 형성 및 수질개선 효과)

  • Lim, Jae-Cheol;Kim, Jin-Keun;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.1
    • /
    • pp.97-106
    • /
    • 2012
  • To investigate the application of corrosion inhibitor on water supply pipes, turbidity, magnitude of corrosion, composition of scale and concentration of metals from an old steel pipe were analysed under inhibitor addition. The concentration of turbidity, iron and copper from the pipes under inhibitor application was 12 ~ 14% of the case which no inhibitor was applied, which suggests the application of inhibitor was very effective for internal corrosion control. In addition, SEM, EDX, XRD and XRF test results showed that application of inhibitor was effective for the decrease of iron concentration and increase of oxygen, phosphorus and calcium concentration, which suggested the existence of protective layer. Therefore, the occurrence of red water will be significantly decreased when inhibitor was applied to the old steel pipes.

저방사화 Cr-Mn-W-V계 스테인리스강의 미세 조직 특성 및 부식 저항성에 미치는 질소첨가와 시효 열처리의 영향

  • 장현영;박용수;김영식
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.784-789
    • /
    • 1995
  • 핵융합로 제1벽재로서 주목받고 있는 저방사화 Fe-Cr-Mn-W계 오스테나이트 스테인리스강에 소량의 V을 첨가하고 그 기본 조성에 시그마상의 생성억제와 합금의 고온강도 향상에 효과가 있는 질소함량을 변화시켜 전보에서 보고한 소둔열처리의 영향에 이어 미세 조직 특성 및 부식 저항성에 미치는 시효열처리의 영향을 살펴보았다. 부식저항성 평가를 위해서는 양극분극시험, 침지시험 수소취성 시험을 행하였으며, 석출상의 생성양상을 살펴보기 위해서는 광학현미경 관찰, 자성측정, EPR시험 및 경도시험을 행하였다. 시험결과, 질소의 함량이 증가할수록 시그마상의 석출이 억제되는 것을 알 수 있었으며, 시효시 실험합금의 부식저항성은 주로 $600^{\circ}C$부근에서 오스테나이트상의 입계에 석출하는 크롬탄화물과 50$0^{\circ}C$부터 비교적 넓은 온도 구간에 걸쳐 페라이트상으로부터 석출 변태되는 시그마상에 의해 지배되고 있음을 알 수 있었다.

  • PDF

증기발생기 전열관의 1차측 응력부식균열 억제에 대한 Shot-Peening 효과분석

  • 박인규;김정수
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.330-335
    • /
    • 1998
  • 국내 전자력 발전소 J-1호기의 증기발생기 전열관에 발생한 1차측 응력부식균열(PWSCC) 결함 데이터를 기초로하여, PWSCC 발생률 및 성장률에 대한 Shot-Peening 효과를 조사하였다. 이를 위하여, (i) Weibull 기울기, (ⅱ) 주기별 성장률 및 (ⅲ) 평균 결함길이 등을 분석하였다. Shot-Peening에 의해 PWSCC 결함 발생틀 및 성장틀은 전반적으로 감소하였으나, Shot-Peening 직후에는 급격한 증가 양상물 보인 후 다시 감소하였다. 한편 Shot-Peening의 PWSCC 절함 성장에 대한 감소 효과는 새로운 결함에 국한되며, 기존의 결함에 대해서는 영향이 거의 없는 것으로 나타났다.

  • PDF

Effect of Mixed Inhibitor on Corrosion Inhibition of Steel Rebar in Chloride Contaminated Concrete Pore Solution (염화물 오염 콘크리트 공극 용액에서 철근의 부식 억제에 대한 혼합 억제제의 효과)

  • Mandal, Soumen;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.32-33
    • /
    • 2021
  • The corrosion of the embedded steel rebars and the consequent deterioration of the reinforced concrete structure has become a challenging concern to the construction industries for the fiscal deficit. However, corrosion inhibitors are potential and being widely used for corrosion mitigation to solve such problems. This study has been focused on the mixed type of corrosion inhibitor where one component of the corrosion inhibitor is organic and another one is inorganic material. 0.1 (M) triethanolamine (TEA) and 0.01 (M) sodium hexametaphosphate (SHMP) have been mixed in distilled water to produce the mixed inhibitor. Studies of the steel rebar corrosion in chloride contaminated (3.5 wt.% NaCl) concrete pore (CCCP) solution has been conducted using different concentrations of corrosion inhibitor. Electrochemical impedance spectroscopy (EIS) method is involved to understand the corrosion behaviour of the steel rebars at different exposure durations.

  • PDF

Inhibition of Mild Steel Corrosion in 0.25 M Sulphuric Acid Solution by Imatinib Mesylate (0.25M 황산 용액 상에서의 Imatinib Mesylate에 의한 연강철 부식 억제)

  • Mohana, K.N.;Shivakumar, S.S.;Badiea, A.M.
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.3
    • /
    • pp.364-372
    • /
    • 2011
  • The corrosion inhibition of imatinib mesylate (IMT) on mild steel in 0.25 M sulphuric acid has been studied using gravimetric and potentiodynamic polarization techniques at various concentrations of inhibitor, temperature and fluid velocities. The results obtained showed that, inhibition efficiency (% IE) increases with increasing concentration of the inhibitor. The adsorption process on mild steel surface follows Langmuir adsorption isotherm. The values of Gibbs free energies of adsorption obtained suggest that, the adsorption process of IMT on mild steel is chemisorption. Thermodynamic parameters were evaluated and discussed. The electron orbital density distribution of HOMO and LUMO of IMT was used to discuss the inhibition mechanism. FT-IR spectroscopy and SEM images were used to analyze the surface adsorbed film.

Research of Corrosion Control Technology for the Product Water of SWRO(Seawater Reverse Osmosis) by using liquid lime (액상소석회를 이용한 SWRO 생산수의 부식제어 연구)

  • Kim, Min-Chul;Hwang, Kyu-Won;Woo, Dal-Sik;Yoon, Seok-Min;Kwak, Myung-Hwa
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.529-536
    • /
    • 2011
  • In this study, we confirmed that the SWRO(Sea Water Reverse Osmosis) production water has more hard corrosiveness than the tap water by fundamental experiment. According to the result, the target of this study was aimed at developing maintenance and anti-corrosion method. In the early stages of the research, batch tests using mild steel coupons and electrochemical experiments were applied to compare the corrosiveness between SWRO production water and the tap water. After then, two corrosion control methods for SWRO production water were applied. Liquid lime($Ca(OH)_2$) and Carbon Dioxide($CO_2$) were inserted and compared with the combination of liquid lime with phosphate corrosion inhibitor and carbon dioxide. The water qualities were evaluated through LSI(Langelier Saturation Index) and proper injection ratio was deduced by the result. Since then, simulated loop system test were performed to evaluate anti-corrosion effect depending on corrosion inhibitors. Subsequently, carbon steel pipes equipped at the loop system were detached for SEM, EDX and XRD analysis to acquire quantitative and qualitative data of the major corrosion products inside the pipes. In conclusion, the controled groups with anti-corrosion techniques applied were effective by appearing 97.4% and 90.9% of improvements in both case of liquid lime and the liquid lime with a phosphate corrosion Inhibitor. furthermore, major components of scale were iron oxides, on the other hand, protective effect of film formation by calcium carbonate($CaCO_3$) could be confirmed.

Effect of Impressed Current System for Corrosion Protection of Rebars in Concrete (콘크리트 중의 철근 부식 억제를 위한 외부전원법의 효과)

  • Moon, Han-Young;Kim, Seong-Soo;Kim, Hong-Sam
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.221-230
    • /
    • 1999
  • Corrosion of rebars can occur if there are cracks, moisture and availability of oxygen or carbonation proceeds, chloride penetrates and diffuses in concrete. Once rebars in concrete corrodes, subsequently accompanied with scaling, spalling in concrete cover. As a result of them, the RC structure is seriously deteriorated. In this study, theoretical review and experiments for cathodic protection(CP) have been performed to control corrosion of rebars in concrete contained chlorides and pre-crack. For CP the impressed current system was applied, the protection effect was investigated when rebars was directly contacted with salt water due to crack and open to much chlorides in concrete. In order to investigate the effect of protection, when CP was energized for 1 year, half-cell potential, potential-decay with current density, corrosion ratio, etc. were measured. With the cathodic protection by impressed current system, the depolarized values of all specimen were met NACE Standard, the effect of 34~84% of the ratio of corrosion area and 84~86% of cross-section reduction were calculated.

A Study on the Development of Corrosion Inhibitor Treating Surface for Reinforcement Concrete Structures (철근 콘크리트 구조물용 표면 처리형 철근 부식억제제의 개발에 관한 연구)

  • Kim, Do-Gyeum;Koh, Kyoung-Taek;Ryu, Gum-Sung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.1
    • /
    • pp.239-247
    • /
    • 2004
  • When the concrete is subjected to chloride attack or carbonation, the passive steel normally initiate corrosion. By product of corrosion make volume of concrete expand 3 to 8 times and induce the stress which lead cracking and spalling of concrete. It result in the loss of the integrity of the concrete structures. Several corrosion inhibitors imported from America, Japan and Europe are currently being used to repair the concrete structures in Korea. However, questions has been raised for protective effect of the corrosion inhibitors which applied in steel reinforced concrete structures. Therefore, we investigated the influence of type and amount of corrosion inhibitors through the tests immersing in salty water. In addition, we developed the corrosion inhibitive agent treating to surface of concrete structures for improving resistance to penetration and corrosion of the steel reinforcement.