• Title/Summary/Keyword: 부분예혼합화염

Search Result 62, Processing Time 0.029 seconds

Numerical Modeling for Turbulent Partially Premixed Flames (난류 부분 예혼합 화염장에 대한 수치 모델링)

  • Kim, Hoo-Joong;Kim, Yomg-Mo;Ahn, Kook-Young
    • 한국연소학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.191-194
    • /
    • 2003
  • The present study is focused on the subgrid scale combustion model in context with a Large Eddy Simulation. In order to deal with detailed chemical kinetic, the level-set method based on a flamelet model is addressed. In this model, the flame front is treated as an interface, represented by an iso-surface of a scalar field G. This iso-surface is convected by the velocity field and its filtered quantities are include the turbulent burning velocity, which is to be modelled. For modelling the turbulent burning velocity, an equation for the length-scale of the sub-filter flame front fluctuations was developed. The formulations and issues for the turbulent premixed and partially premixed flames are addressed in detail.

  • PDF

Low Strain Rate Flame Extinction Characteristic of Oxygen Enhanced Opposed Flow Partially Premixed Flame in a Mesoscale Channel (채널 내부 대항류 산소부화 부분예혼합 화염의 저신장율 소화특성)

  • Lee, Min Jung;Kim, Nam Il
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.243-244
    • /
    • 2014
  • The opposed flow flame in a mesoscale channel was constructed to observe the flame stabilization behaviors at low strain rate conditions (<$10s^{-1}$). The purpose of this study is to get the overall flame behaviors of partially premixed flames with oxygen enhanced conditions at low strain rates. The oxygen ratio in oxidizer was changed from 18 to 30 %. Conclusively, the flame extinction limit approached to about $1s^{-1}$, and divided into three representative regimes corresponding to self propagating flame, transitional flame, quenching flame regimes.

  • PDF

Flame Characteristics of Diesel Spray in the Condition of Partial Premixed Compression Ignition (부분 예혼합 압축착화 조건에서 디젤분무의 화염특성)

  • Bang, Joong Cheol;Park, Chul Hwan
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.2
    • /
    • pp.24-31
    • /
    • 2012
  • Diesel engines exhaust much more NOx(Nitrogen Oxides) and PM(Particulate Matter) than gasoline engines, and it is not easy to reduce both NOx and PM simultaneously because of the trade-off relation between two components. This study investigated flame characteristics of the partial premixed compression ignition known as new combustion method which can reduce NOx and PM simultaneously. The investigation was performed through the analysis of the flame images taken by a high speed camera from the visible engine which is the modified single cylinder diesel engine. The results obtained through this investigation are summarized as follows; (1) The area of the luminous yellow flame was reduced due to the decrease of flame temperature and even distribution of temperature. (2) The darkish yellow flame zone caused by the shortage of the remaining oxygen after the middle stage of combustion was considerably reduced. (3) Since the ignition delay was shortened, the violent combustion did not occur and the combustion duration became shortened.

An Experimental Study on Emission Characteristics of a Semi-Bunsen Type Gas Burner (가스보일러용 세미 분젠형 버어너의 배기 특성 연구)

  • Jurng, J.S.;Park, E.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.353-358
    • /
    • 1995
  • The emission characteristics of a semi-Bunsen type burner for gas boilers were studied experimentally. The experimental results reveal that nitric oxide emission increases with fuel flow rate. It is linearly proportional to total fue flow rate at a small amount of fuel up to 0.4 liters per minute. It does not change significantly within the range of fuel flow rate from 0.4 to 1.2 liters per minute per nozzle and increases at large fuel flow rate. The carbon monoxide emission reveals to be dependent upon the fuel flow rate per each nozzle and the number of fuel injection nozzles. Diameter of an injection nozzle could have an effect on the emission characteristics of this type of burners. However, there is no marked change in the nitric oxide emission if the total fuel flow rate is same with different nozzle sizes.

  • PDF

New Approach to Low NOx Combustion by Changing Combustor Pressure (연소실 압력변동을 이용한 저 NOx 연소의 새로운 접근)

  • Kim Jong Ryul;Choi Gyung-Min;Kim Duck-Jool
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.10 s.241
    • /
    • pp.1148-1155
    • /
    • 2005
  • In this study, the influence of changing combustor pressure on nitric oxide emission was investigated. Expansion of reaction region was more clear in the P$^{*}$ <1 conditions compared to the P$^{*}\geq1$ conditions, and it could be observed that flames are distinct in the P$^{*}\geq1$ conditions and that brightness is relative low and wide distribution is shown in the P$^{*}$ <1 conditions. In the respect of temperature distribution, narrow and high-temperature region was shown in the P$^{*}\geq1$ conditions. On the other hands, overall uniform temperature distributions were shown in the P$^{*}$ <1 conditions. Nitric oxide emission decreased with decreasing combustor pressure. This tendency was explained by the mean flame temperature distribution. Low NOx combustion is ascribed to wide-spread reaction region in the low combustor Pressure and oscillation were shown P$^{*}\leq0.97$, and strength and sizes of oscillation were more increased with lower pressure index. These results demonstrate that flame shape and nitric oxide emission can be controlled with changing combustor pressure.

CO Emission Characteristics in the Interacting Counterflow Methane and Hydrogen Partially Premixed Flames (상호작용하는 대향류 메탄-수소 부분예혼합화염의 CO 배출특성)

  • Park, Ji-Woong;Oh, Chang Bo;Kim, Tae-Hyung;Park, Jongho
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.3
    • /
    • pp.1-8
    • /
    • 2012
  • The CO emission characteristics of interacting hydrogen and methane partially premixed flames were numerically investigated. A counterflow geometry was introduced to establish interacting two partially premixed flames. An one-dimensional OPPDIF code was used to simulate the interacting flames. The GRI-v3.0 was used to calculate the chemical reactions. Emission index for CO(EICO) was evaluated to quantify the CO emitted from the interacting flames. The global strain rate and equivalence ratios for each flame(${\Phi}_{CH_4}$ and ${\Phi}_{H_2}$) were used as parameters to control the extent of interaction between two partially premixed flames. When ${\Phi}_{CH_4}$ was kept to stoichiometric condition and ${\Phi}_{H_2}$ was at rich condition, unburned H2 species of hydrogen flame was transported to the methane flame and affected reactions related with CO formation. When ${\Phi}_{CH_4}$ increased from a stoichiometry to rich condition while ${\Phi}_{H_2}$ was kept to stoichiometric condition, EICO increased initially, had a peak value at ${\Phi}_{CH_4}=1.5$ and decreased gradually. This could be elucidated with an analysis for the elementary reactions related with CO formation.

Enhancement of Burner Performance of Household Gas Fired Absorption Chiller/Heaters (가정용 가스 냉난방기용 연소기의 성능개선 연구)

  • Yoon, Young-Seok;You, Hyun-Seok;Kim, Tae-Han;Lee, Joong-Seong;Han, Jeong-Ok
    • 한국연소학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.111-115
    • /
    • 1999
  • In order to enhance the burner performance of household gas fired absorption chiller/heaters, the operating condition(excess air $\approx$ 10%) of the burner currently being used was required to be optimized. In this regard, we examined where the $CO_{\min}$. emission limit was located between blow off and yellow tip limit and how much amount of excess air was exhausted by means of observing blow off and yellow tip limit. It was found that the $CO_{\min}$ limit(excess air ${\approx}$ 4%) was determined near the yellow tip limit. The effect of exhaust pressure on the $CO_{\min}$. limit was that, if exhaust pressure was higher than that in steady condition, higher air blower fan rpm is demanded to maintain the $CO_{\min}$ limit. Therefore, it was necessary to optimize the operating condition of burner in terms of a thermal efficiency and safety.

  • PDF

Experimental Study on Dilution Effect of Exhaust Gas in SNG Combustion on a Model Gas Turbine (가스터빈에서 SNG 연료 조성에 대한 희석제의 배기배출물 저감효과에 대한 실험적 연구)

  • Joo, Seongpil;Yoon, Jisu;Kim, Jeongjin;Kim, Seongheon;Yoon, Youngbin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.7
    • /
    • pp.603-610
    • /
    • 2016
  • This paper describes experimental results about emission and NOx reduction of dilution effect (Nitrogen and carbon dioxide) about various fuel compositions of synthetic natural gas (SNG). Combustion experiment was performed to investigate the combustion characteristics for SNG with various hydrogen ratio in SNG, heat input and equivalence ratio in a partially premixed model gas turbine combustor. NOx emission was similar to each hydrogen ratio and flame characteristics was investigated from OH chemiluminescence images. There was a singularity of CO emission in stoichiometric condition and it can be identified using OH chemiluminescence intensity. In addition, dilution effect was studied in using nitrogen and carbon dioxide as diluent to reduce the NOx emission. Carbon dioxide diluent was more effective to NOx reduction than nitrogen diluent because of its high diluent specific heat and its heat capacity.

Combustion Characteristics of Non-premixed VIStA Burner in Once-Through-Type Boiler (관류보일러 연소실에서 비예혼합 VIStA 버너의 연소 특성)

  • Ahn, Joon;Kim, Hyouck-Ju;Choi, Kyu-Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.5
    • /
    • pp.547-552
    • /
    • 2010
  • A modified VIStA (vortex inertial staged air) burner was developed and used in a once-through-type boiler. For safety, the combustion in this burner is of the non-premixed type. An air damper is installed to control the distribution of air to each combustion chamber. The effects of the air-fuel ratio and air distribution on NOx formation were investigated. The newly modified VIStA burner gives NOx reduction effect by maximum 20% in the combustion chamber of a boiler, while it yields more uniform flame than the conventional burner.

Effects of $CO_2$ and $H_2O$ Additions on Partially Premixed Counterflow Flame by Considering Nongray Gas Radiation (비회색 가스 복사를 고려한 층류대향류 부분예혼합 화염에서의 $CO_2$$H_2O$ 첨가에 따른 영향 연구)

  • Jo, Bum-Jin;Kim, Tae-Kuk
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.3
    • /
    • pp.10-16
    • /
    • 2005
  • Detailed flame structures of the counterflow flames of $CH_4/Air$ formed with $CO_2$ and $H_2O$ addition are studied numerically. The detailed chemical reactions are modeled by using the OPPDIF and CHEMKIN-II code. Only the $CO_2$ and $H_2O$ are assumed to participate in radiative heat transfer while all other gases are assumed to be transparent. The discrete ordinates method(DOM) and the narrow band based WSGGM with a gray gas regrouping technique(WSGGM-RG) are applied for modeling the radiative transfer through non-homogeneous and non-isothermal combustion gas mixtures generated by the counter flow flames. The results compared with the SNB model show that the WSGGM-RG is successful in modeling the counterflow flames with non-gray gas mixture. The numerical results show that the addition of $CO_2$ and $H_2O$ to the oxidant nozzle lowers the peak temperature and the NO concentration in flame.

  • PDF