• 제목/요약/키워드: 부분슬립

검색결과 33건 처리시간 0.023초

재질 열화와 프레팅 피로거동 평가에 관한 연구 (A Study on Material Degradation and Fretting Fatigue Behavior)

  • 권재도;최성종;성상석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.157-162
    • /
    • 2001
  • Fretting is a potential degradation mechanism of structural components and equipments exposed to various environments and loading conditions. The fretting degradation, for example, can be observed in equipments of nuclear, fossil as well as petroleum chemical plants exposed to special environments and loading conditions. It is well known that a cast stainless steel(CF8M) used in a primary reactor coolant(RCS) degrades seriously when that material is exposed to temperature range ken $290^{\circ}C{\sim}390^{\circ}C$ for long period. This degradation can be resulted into a catastrophical failure of components. In the present paper, the characteristics of the fretting fatigue are investigated using the artificially aged CF8M specimen. The specimen of CF8M are prepared by an artificially accelerated aging technique holding 1800hr at $430^{\circ}C$ respectively. Through the investigations, the simple fatigue endurance limit of the virgin specimen is not altered from that obtained from the fatigue tests imposed the fretting fatigue. The similar tests are performed using the degraded specimen. The results are not changed from those of the virgin specimen. The significant effects of fretting fatigue imposed on both virgin and degraded specimen on the fatigue strength are not found.

  • PDF

개선된 부착슬립 모델을 적용한 부분 CFST 기둥의 수치해석 (Numerical Approach for a Partial CFST Column using an Improved Bond-Slip Model)

  • 황주영;곽효경
    • 한국전산구조공학회논문집
    • /
    • 제33권3호
    • /
    • pp.153-158
    • /
    • 2020
  • 본 논문에서는 부분 CFST (concrete-filled steel tube) 기둥에 대한 수치해석적 저항력 평가 방법에 대해 소개하고 있다. 기존 RC(reinforced concrete) 기둥에서 소성힌지가 발생할 것으로 예상되는 부분을 강관으로 보강함으로써 완전 CFST 기둥보다는 적은 재료를 사용하여 비슷한 휨 모멘트 저항력을 가지는 부분 CFST 기둥의 디자인 컨셉을 제시하였다. 부분 CFST 기둥에서 외부 강관과 내부 콘크리트 사이의 계면에서 거동을 수치해석적으로 모사하기 위해 개선된 부착슬립모델을 적용한 유한요소모델을 구축하고, 이중곡률 휨-압축시험결과와 비교를 통해 타당성을 검증하였다. 검증된 수치모델을 바탕으로 매개변수 연구를 통해서 P-M 상관도를 그려 단면 조건에 따른 최대 저항력을 평가하였다. 또한, 강관 두께별로 필요 보강길이를 산출하고, 보강 조건에 따른 부분 CFST 기둥에서의 파괴메커니즘을 분석하였다.

부분 강합성보의 시간의존적 거동해석 (Time-Dependent Behavior of Partially Composite Beams)

  • 곽효경;서영재
    • 한국전산구조공학회논문집
    • /
    • 제13권4호
    • /
    • pp.461-473
    • /
    • 2000
  • 이 논문은 콘크리트의 크리프와 건조수축 현상을 고려한 강재와 콘크리트의 부분 합성보의 거동의 해석을 위한 모델을 제안하고 있다. 부분합성 거동은 선형 부분전단 연결이론을 토대로 합성보를 일정한 수의 요소로 분할한 후 각 절점에서 평형조건과 적합조건을 기초로하여 구성 방정식을 구성하고 경계조건과 각 요소에 대한 구성 방정식을 순차적으로 적용하는 방법으로 해석모델이 구성되었다. 또한 콘크리트의 시간에 따른 현상인 크리프와 건조수축의 영향도 고려되었다. 제안된 해석모델은 다경간 연속 합성보의 슬립거동을 효과적으로 나타낼 수 있다. 제안된 해석 모델의 검증을 위해 기존 연구의 결과와 비교되었으며, 여러 조건에 대한 합성보의 해석을 통해 제안된 모델의 적용성을 입증하였다.

  • PDF

합성보의 부착슬립 효과를 고려한 유한요소 기반의 수치해석모델 (FE Based Numerical Model to Consider Bond-slip Effect in Composite Beams)

  • 곽효경;황진욱
    • 한국전산구조공학회논문집
    • /
    • 제23권1호
    • /
    • pp.95-110
    • /
    • 2010
  • 본 논문에서는 합성보의 부착슬립 효과를 고려할 수 있는 유한요소 수치모델을 제안하고자 한다. 전단연결재가 설치된 슬래브와 거더 경계에서 선형 전단력-슬립 관계를 가정하여, 부착슬립 거동을 해석할 수 있는 수치모델이 구현되었다. 본 수치모델을 통하여 축 방향의 자유도를 부가하지 않고 2절점의 보 요소를 적용하여 합성보 경계에서의 슬립 거동을 고려하는 것이 가능하다. 선형 부분전단 연결이론을 토대로 한 슬립 거동의 지배방정식은 슬래브와 거더 경계에서 힘의 평형상태와 단면 내에서 상수로 가정된 곡률을 바탕으로 결정된다. 또한, 지배방정식 구성에 있어서 요소 양 절점에서의 휨 모멘트 값을 필요로 하기 때문에 유한요소 해석으로 도출되는 상수 모멘트를 요소 내에서 선형으로 분포시켰다. 제안된 수치모델을 적용한 해석결과를 기존 연구의 수치해석 결과 및 실험결과와 비교하였으며, 하중-처짐 곡선의 비교를 통하여 본 모델의 성능을 검증하였다.

부착-슬립을 고려한 철근콘크리트 접합부의 이력 손상 모델 개발 (Hysteretic Damage Model for Reinforced Concrete Joints Considering Bond-Slip)

  • 김도연;최인길
    • 대한토목학회논문집
    • /
    • 제28권4A호
    • /
    • pp.517-528
    • /
    • 2008
  • 이 논문에서는 철근과 콘크리트 사이의 부착-슬립을 실제적으로 고려한 철근콘크리트 접합부의 이력 손상 모델을 제안하였다. 슬립을 가시화하기 위해 콘크리트와 철근의 변위장이 서로 다른 프레임 요소를 개발하였다. 파이버 단면 개념으로부터 콘크리트, 철근 그리고 부착에 대한 적합방정식을 정의하였다. 부분적인 제하 및 재재하 상태를 고려하기 위해 철근 이력곡선의 수정이 이루어졌다. 단조증가 상태의 국부적 부착응력-슬립 관계는 손상 계수에 따라 슬립이 역전될 때마다 갱신하였다. 구속된 콘크리트에 매입된 철근 시험체와 기초에 정착된 철근콘크리트 기둥 시험체, 그리고 보-기둥 부재의 수치해석을 통해 모델의 정확성을 검증하였고, 부착-슬립 효과를 고려함으로써 하중 이력에 따른 에너지 소산 정도를 평가할 수 있었다.

재질 열화와 프레팅 피로거동 평가에 관한 연구 (A Study on Material Degradation and Fretting Fatigue Behavior)

  • 권재도;성상석;최성종
    • 대한기계학회논문집A
    • /
    • 제25권8호
    • /
    • pp.1287-1293
    • /
    • 2001
  • Fretting is a potential degradation mechanism of structural components and equipments exposed to various environments and loading conditions. The fretting degradation, for example, for example, can be observed in equipments of nuclear, fossil as well as petroleum chemical plants exposed to special environments and loading conditions. It is well known that a cast stainless steel(CF8M) used in a primary reactor coolant(RCS) degrades seriously when that material is exposed to temperature range from 290$\^{C}$∼390$\^{C}$ for long period. This degradation can be resulted into a catastrophical failure of components. In the present paper, the characteristics of the fretting fatigue are investigated using the artificially aged CF8M specimen. The specimen of CF8M are prepared by an artificially accelerated aging technique holding 180hr at 430$\^{C}$ respectively. Through the investigations, the simple fatigue endurance limit of the virgin specimen is not altered from that obtained from the fatigue tests imposed the fretting fatigue. The similar tests are performed using the degraded specimen. The results are not changed from those of the virgin specimen. The significant effects of fretting fatigue imposed on both virgin and degraded specimen on the fatigue strength are not found.

슬립앵커를 이용한 강-콘크리트 합성 거동 연구 (A Study on the Composite Behavior of Steel-Concrete with Slip Anchor)

  • 원덕희;한택희;김승준;한승룡;강영종
    • 복합신소재구조학회 논문집
    • /
    • 제2권2호
    • /
    • pp.7-12
    • /
    • 2011
  • 현재 강재와 콘크리트를 합성화 시키는 방법으로 대표적인 것이 스터드를 이용하는 것이다. 그러나 이 방법을 강합성 기둥에 적용할 경우에 용접량이 많아져 이로 인하여 강재의 성능이 변하여 국부좌굴로 유도될 가능성이 매우 크다. 외부가 구속된 CFT 부재나 내부 구속 중공 CFT 부재 그리고 내부가 강관으로 내부 구속 중공 RC 부재에 적용할 경우에 합성 거더에 비하여 강재와 콘크리트가 분리되려는 인발력 대신 슬립에 의한 분리현상이 더 크게 발생한다. 이렇기 때문에 스터드의 높이 보다는 콘크리트와 강재가 합성되는 면적을 넓혀주는 것이 더 필요하다. 이러한 목적을 달성하기 위하여 일정부분 강관에 용접을 하여 부착을 하고 ㄷ자 형으로 제작된 슬립앵커의 철근이 콘크리트 속에 삽입되어 강재와 콘크리트의 일체 거동성을 높였다. 이러한 방법의 경우에는 곡률을 가진 강구조물 등에 적용될 경우 큰 효과를 발휘할 것으로 판단된다. 본 연구에서는 제안된 슬립앵커를 H빔에 설치를 하여 축하중을 가하는 Push-over Test를 통하여 거동 특성을 분석하였다.

전단슬립 효과를 고려한 합성보의 유효강성 (Effective Stiffness of Composite Beams Considering Shear Slip Effects)

  • 허병욱;배규웅;문태섭
    • 한국강구조학회 논문집
    • /
    • 제16권5호통권72호
    • /
    • pp.671-682
    • /
    • 2004
  • 본 연구는 부분 전단연결을 가지는 강-콘크리트 합성보의 처짐에 미치는 전단슬립의 영향을 조사하는 것이다. 현재 각국의 설계규준에서는 합성보의 처짐 계산시 전단연결재의 강도와 관련되어 있지만, 본 연구에서는 하중조건에 상관없는 전단연결재의 강성에 기반을 둔 정확한 해를 유도하였다. 우선, 평형조건, 곡률의 적합조건에 기반을 둔 3가지 하중조건에서의 합성보의 등가강성을 유도하고, 이로부터 하중조건에 상관없이 슬립의 영향을 적용할 수 있는 간편한 제안식을 유도하였다. 이러한 제안식의 타당성을 검증하기 위해서 현재 AISC에서 사용하고 있는 합성보의 유효강성 및 Nie가 제안한 식과 비교하였다. 일반적으로 사용되는 보의 경우, 전단슬립의 영향은 스팬이 짧을 경우, AISC에 비해서 최대 18%까지의 강성의 감소를 나타냄을 알 수 있었다. 완전합성보의 경우, AISC의 제안 값이 본 연구의 결과 보다 크게 나타났는데, 이는 안전측이 되지 못함을 알 수 있었으며, 불완전 합성보의 경우, AISC 제안식이 본 연구보다 강성을 과소 평가하는 결과를 나타내었다.

1Cr-0.5Mo 강의 재질열화가 프레팅 피로거동에 미치는 영향 (The Effect of Degradation on the Fretting fatigue for 1Cr-0.5Mo Steel)

  • 권재도;최성종;김경수;배용탁
    • 대한기계학회논문집A
    • /
    • 제27권11호
    • /
    • pp.1979-1985
    • /
    • 2003
  • Fretting is a kind of surface degradation mechanism observed in mechanical components and structures. The fretting damage decreases in 50-70% of the plain fatigue strength. This may be observed in the fossil power plant and the nuclear power plant used in special environments and various loading conditions. The thermal degradation of material is observed when the heat resisting steel is exposed for long period time at the high temperature. In the present study, the degraded 1Cr-0.5Mo steel used for long period time at high temperature (about 515$^{\circ}C$) and artificially reheat-treated materials are prepared. These materials are used for evaluating an effect of thermal aging on the fretting fatigue behavior. Through the experiment, it is found that the fretting fatigue endurance limit of the reheat-treated 1Cr-0.5Mo steel decreased about 46% from the non-fretting fatigue endurance limit, while the fretting fatigue endurance limit of the degraded 1Cr-0.5Mo steel decreased about 53% from the non-fretting fatigue endurance limit. The maximum value of fatigue endurance limit difference is observed as 57%(244 MPa) between the fretting fatigue of degraded material and non-fretting fatigue of reheat-treated material. These results can be a basic data to a structural integrity evaluation of heat resisting steel considered to thermal degradation effect.

램프를 이용한 폴리실리콘 재결정화 (A Study on Recrystallization of Polysilicon Using Lamps)

  • 최진호;장윤석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계합동학술대회 논문집
    • /
    • pp.206-209
    • /
    • 2002
  • 본 논문에서는 폴리실리콘의 재결정화 공정에서 발생하기 쉬운 폴리실리콘의 엉김현상, 슬립, 부분적인 실리콘 기판의 녹음현상 등을 방지하기 위한 방법을 제시한다. 그리고 재결정화 된 박막의 질을 향상시키기 위한 폴리실리콘과 보호 산화막(capping oxide)의 두께 변화에 따른 실험 결과를 살펴본다. 폴리실리콘의 엉김현상은 매몰 산화막(buried oxide)과 액체 상태의 실리콘 사이의 wetting angle과 관계되는데, 이를-방지하기 위해서는 재결정화할 폴리실리콘과 산화막의 계면에 질소를 주입시켜주면 되는데, 이는 재결정화할 시료를 암모니아 가스 분위기에서 열처리를 통하여 해결할 수 있다. 그러고 실러콘 기판의 국부적 녹음 현상 및 슬립은 실리콘 기판의 윗면을 mechanical damage에 의해서 약 $20{\mu}m$ 정도의 거칠기를 가지도록 하면 이러한 현상을 방지할 수 있다. 그러고 폴리실리콘이 재결정활 될 때 부피의 변화가 발생하며, 이로 인하여 재결정화된 박막의 두께는 위치에 따라 변화한다. 재결정화된 박막 두께의 균일도를 유지하기 위해서는 재결정화할 폴리실리콘 두께의 3배 이상이 되는 보호 산화막을 사용하였을 때 원하는 균일도를 얻을 수 있었다.

  • PDF