• Title/Summary/Keyword: 부모멘트실험

Search Result 281, Processing Time 0.024 seconds

Tests for Moment Redistribution in Flat Plates with Different Reinforcement Details according to End and Midspan Moment Distributions (단부 및 중앙부 플랫플레이트의 철근 분배율에 따른 모멘트 재분배 실험)

  • Choi, Jung-Wook;Song, Jin-Kyu
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.5
    • /
    • pp.603-611
    • /
    • 2007
  • Three interior slab-column connections designed by equal static moments and by different distribution of end and midspan moments were tested. Each test specimen consists of a 4.2 m square slab and a 355 mm square column stub. The slab thickness is 152 mm. Test results showed not only that flat plate systems can undergo considerable redistribution of moments from the uncracked state to final maximum capacity, but also that the distribution of moments is controlled largely by the distribution of reinforcement adopted by the designer. Tests also indicated that the punching shear strength of slabs can be affected by the redistributed moments.

An Experimental Study on the Behavior of Connections of Thin-Walled Cold-Formed Steel Section Frames (박판 냉간성형형강 골조의 접합부 거동에 관한 실험적 연구)

  • Kwon, Young Bong;Cho, Jong Su;Song, Jun Yeup;Kim, Gap Deuk
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.3
    • /
    • pp.281-290
    • /
    • 2003
  • A series of connection tests of portal frames which were composed of cold-formed steel studs and rafters was carried out to study the moment-rotation relation, the rotational rigidity, and the yield and the ultimate moment of the connections. The main factors of the tests were the thickness, the shape of the connecting members which were made of mild steel, and the torsional restraints of the test specimens. The test results were compared with those obtained through the non-linear analysis, for verification. The secant stiffness estimated from the experimental moment-rotation curve was proposed for the rotational rigidity of semi-rigid connections, and its validity was verified in the structural frame analysis.

Performance Evaluation of Inelastic Rotation Capacity of Reinforced Concrete Beam-Column Connections (철근콘크리트 보-기둥 접합부의 비탄성 회전 능력에 대한 성능 평가)

  • Lee, Ki-Hak;Woo, Sung-Woo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.5
    • /
    • pp.1-9
    • /
    • 2007
  • This study summarizes the results of a research project aimed at investigating the inelastic rotation capacity of beam-column connections of reinforced concrete moment frames. A total of 91 test specimens for beam-column joint connections were examined in detail, and 28 specimens were classified as special moment frame connections based on the design and detailing requirements in the ACI 318-02 Provisions. Then the acceptance criteria, originally defined for steel moment frame connections in the AISC-02 Seismic Provisions, were used to evaluate the joint connections of concrete moment frames. Twenty-seven out of 28 test specimens that satisfy the design requirements for special moment frame structures provide sufficient strength and are ductile up to a plastic rotation of 0.03 rad. without any major degradation in strength. Joint shear stress, column-to-beam flexural strength ratio, and transverse reinforcement ratio in a joint all play a key role in good performance of the connections.

Deformation Capacity of Existing Moment Connections retrofitted with Horizontal Stiffeners (수평스티프너로 보강된 모멘트 접합부의 변형능력)

  • Oh, Sang-Hoon;Kim, Young-Ju;Moon, Tae-Sup
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.220-227
    • /
    • 2005
  • 최근에 수행된 철골모멘트 접합부의 실험 및 해석결과에 의하면, 기둥으로 각형강관을 가진 접합부가 H형강을 기둥으로 사용하는 접합부에 실험체에 비해서 조기에 스캘럽 단부에서 취성파단이 발생하는 열등한 변형능력을 나타냈다. 이는 각형강관 기둥의 면외변형에 따른 보 웨브의 모멘트 전달효율의 저하, 스캘럽이 가지는 노치효과 및 합성보의 구속효과가 주요원인으로 밝혀졌다. 실험결과는 또한 개선된 수평스티프너로 하부 플랜지를 보강한 실험체는 우수한 변형능력을 가짐을 보였다. 본 연구에서는 이러한 영향을 고려하여, 다양한 수평스티프너로 보강된 접합부에 관한 유한요소해석을 실시하였다. 해석결과를 바탕으로 파일럿 테스트를 실시한 결과, 수평스티프너로 보강된 RBS 접합부 (SR)와 연장된 수평스티프너를 가진 접합부(LH)는 우수한 변형능력을 보였다.

  • PDF

Cyclic Seismic Testing of Full-Scale Column-Tree Type Steel Moment Connections (반복재하 실물대 실험에 의한 컬럼-트리(Column-Tree) 형식 철골 모멘트 접합부의 내진거동 연구)

  • Lee, Cheol Ho;Park, Jong Won
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.4 s.37
    • /
    • pp.629-639
    • /
    • 1998
  • This paper summarizes the results of full-scale cyclic seismic performance tests on three column-tree type steel moment connections. Each test specimen consisted of a $H-600{\times}200$ beam and a $H-400{\times}400$ column of SS41 (SS400). Key parameter included was column PZ (panel zone) strength relative to beam strength. The seismic performance of specimen with stronger PZ tended to be inferior. Total plastic rotations available in the specimens ranged from 1.8 to 3.0 (% rad). The limited test results in this study seem to support the speculation that permitting PZ yielding shall be more beneficial to enhancing total plastic rotation capacity of the moment connection. Beam flange fracture across the heat affected zone and divot-type pullout of the column flange were observed in the tests. A conceptual mechanical model consistent with observed test results was also sought.

  • PDF

Experimental Tests and Analytical Study for the Prediction of the Plastic Moment Capacity of an Unstiffened Top and Seat Angle Connection (무보강 상·하부 ㄱ형강 접합부의 소성휨모멘트 저항능력 예측을 위한 실험 및 해석적 연구)

  • Yang, Jae-Guen;Choi, Jung-Hwan;Kim, Hyun-Kwang;Park, Jae-Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.5
    • /
    • pp.547-555
    • /
    • 2011
  • An unstiffened top and seat angle connection is a type of partially restrained connection that is suitable for low- and medium-rise steel buildings. The plastic moment resisting capacity of such connection is needed in practical design, in addition to the accurate prediction of the initial rotational stiffness. Therefore, most of the studies conducted for the mentioned connections were performed to predict the initial stiffness and the plastic moment resisting capacity with varying geometric properties. The main parameters of such experimental tests were the thickness and high-strength bolt gauge distance of AISC LRFD-type A top and seat angle connections. Based on the test results, the analytical model was also proposed in this study. The applicability of the proposed model was verified by comparing the test results from this study with those of other studies.

Cyclic Testing of Bracket and WUF-B Type Weak-Axis Steel Moment Connections (브라켓 및 WUF-B 형식 철골모멘트골조 약축접합부 내진성능평가)

  • Lee, Kang Min;Jeong, Hee Taek;Yoon, Seok Ryong;Lee, Eun Mo;Oh, Kyung Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.4
    • /
    • pp.483-491
    • /
    • 2008
  • There has been much focus on the strong axis steel moment connections after the Northridge earthquake in 1994. However, research studieson the seismic behavior of weak axis moment connections could be hardly found despite the fact that these connection details have been frequently used as seismic details of MRF in Korea. Therefore, the objective of this research is to provide better knowledge on the seismic behavior of weak-axis steel moment connections, which can be widely applicable to many structures with similar characteristics. For this purpose, an experimental program was designed and performed with twotypes of weak-axis steel moment connections, namely the bracket type and WUF-B type, based on the survey of existing field data and literatures. Using the experimental results obtained from the quasi-static cyclic testing of these specimens, structural performances of the joints such as hysteretic curves, maximum strength capacities and the strain of reinforced bars were investigated. From the test results, the bracket-type connection was shown to have more than a 5% story drift capacity, compared with the WUF-B type connection's 4%. These specimens were also shown to have higher strength capacities than the nominal design strength. The bracket-type connection showed a slow strength degradation after maximum strength was researched. However,the WUF-B type connection showed a rapid strength degradation that caused brittle behavior.

Load-Displacement Characteristics and Interactive Load Capacity Model for Metal Plate Connections in Wood(II) - Interactive Load Capacity Model and Experimental Verification - (목재(木材)-금속(金屬)플레이트 접합부(接合部)의 하중(荷重)-변위(變位) 특성(特性) 및 조합하중성능(組合荷重性能)에 대한 모형 분석 (II) - 조합하중모형(組合荷重模型)과 실험적(實驗的) 입증(立證) -)

  • Park, Moon-Jae;Jung, Hee-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.12-18
    • /
    • 1995
  • 고도(高度)의 엔지니어링 구조물(構造物)로 경제성이 높은 경량(輕量) 목조(木造)트러스에 사용될 수 있는 소나무(Pinus densiflora) 재(材)에 적용한 20게이지 아연도금 강(鋼) 플레이트 접합부(接合部)의 조합하중(組合荷重) 및 모멘트 성능(性能)을 평가하기 위하여 정밀도를 개선(改善)한 편심가력(偏心加力) 장치(裝置)를 창안하여 실험하고 반강절(半剛節) 접합부의 개념(槪念)과 가상(假想)일 법(法)을 적용한 모형을 유도하여 비선형(非線形) 해석(解析)하였다. 반강절(半剛節) 접합부(接合部)의 개념을 도입하여 저자가 유도한 비선형(非線形) 모형으로 조합하중 하에서의 접합부 거동을 해석한 결과, 금속 플레이트 접합부의 모멘트는 Wolfe 모형에 비하여 정확도가 높은 값으로 계산되었는데, 이는 비선형모형에서 접합부의 반강성(半剛性)에 의한 2차적인 모멘트의 영향을 적절히 고려한 때문으로 판단되었다. 본 연구에서 사용한 실험장치는 조합하중에 대한 금속 플레이트 접합부의 성능을 평가하기 위한 표준시험법(標準試驗法)으로 적용될 수 있을 것이며, 비선형(非線形) 해석방법(解析方法)은 조합하중(組合荷重)및 모멘트 성능(性能)을 예측(豫測)하는데 활용될 수 있다.

  • PDF

Strength Model for Eccentric Shear of Flat Plate-Column Connections under Unbalanced Moment (불균형 휨모멘트를 받는 플랫플레이트-기둥 접합부의 편심전단강도)

  • Choi Kyoung-Kyu;Park Hong-Gun
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.2 s.80
    • /
    • pp.229-240
    • /
    • 2004
  • Many experiments have been performed to investigate eccentric shear strength and unbalanced moment-carrying capacity of flat plate-column connections under combined gravity and lateral load. However, each existing experiment used different test setup, and the shear strength of the connection was different depending on the test setup. Current design methods which were based on the experimental results might not accurately explain the shear strength of the flat plate. In a companion study, based on results of nonlinear finite element analyses, an alternative design method for the plate-column connection was developed. However, in this method, eccentric shear strength of the connection which was required for assessing unbalanced moment-carrying capacity was evaluated by an empirical formula. In the present study, a theoratical approach using Rankine's failure criterion was attemped to investigate failure mechanism of the eccentric shear. Based on the results, an improved strength model of the eccentric shear was developed, and it was verified by comparison with the existing experimental results. By means of the strength model, the design method developed in the companion study was re-verified.

Numerical Study on Interior Flat Plate-Column Connections Subjected to Unbalanced Moment (불균등 휨모멘트를 받는 플랫 플레이트-기둥 접합부에 대한 해석연구)

  • 최경규;황영현;박홍근
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.949-960
    • /
    • 2002
  • Flat plate structures under lateral load are susceptible to punching shear failure of the slab-column connection. To prevent such brittle failure, strength and ductility of the connection should be ensured. However, due to complexity in the behavior and difficulty in simulating the actual load and boundary conditions of the flat plate system, it is not easy to obtain reliable data regarding to the strength and ductility from the previous experimental studies. In the present study, a numerical study was performed for interior connections of continuous flat plate. For the purpose, a computer program for nonlinear FE analyses was developed, and the validity was verified by comparisons with the existing experimental results. Through the parametric studies, the variations of bending moment, shear, and torsional moment around the connection were investigated. Based on the findings of the numerical studies, the aspects which need to be improved in current design methods were discussed. The results of the present study will be used for developing a design method for the flat plate-column connection in the companion paper.