• Title/Summary/Keyword: 부등시

Search Result 119, Processing Time 0.032 seconds

Effect of Outrigger Wall Reinforced with Post Tension on Reducing Differential Column Shortening (포스트 텐션으로 보강된 아웃리거 벽체의 부등기둥축소량 저감 효과)

  • Lim, You-Jin;Kim, Han-Soo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.4
    • /
    • pp.237-244
    • /
    • 2020
  • This study investigates the effect of the outrigger wall reinforced with post-tension on reducing differential column shortening. Since the outrigger wall is a concrete structure, the effect of its long-term behavior should be considered. The long-term behavior of the outrigger wall increases differential column shortening and decreases the shear force acting on the outrigger. When the stiffness of the outrigger becomes small, the effect of its long-term behavior increases. Furthermore, a method of reinforcing with post-tension to reduce differential column shortening is proposed. Following the analysis, it was confirmed that the post-tension method shows a significant reduction in the differential column shortening. This study shows that the effect of the outrigger wall reinforced with post-tension on reducing differential column shortening increases with the prestressing force of tendon.

The Comparative Assessment of the KVA and Dynamic Stereoacuity (동적시력(KVA)과 동적 입체시의 비교 평가)

  • Kim, Young-Cheong;Shim, Hyun-Suk;Kim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.519-525
    • /
    • 2014
  • Purpose: On this study, we investigated the relationship between the kinetic visual acuity (KVA) and the dynamic stereoacuity and the effects of anisometropia with measuring KVA and the dynamic stereoacuity. Methods: For 63 adults (male 30, female 33), KVA and the dynamic stereoacuity were measured by using the kinetic visual acuity tester (KOWA AS-4A) and the Howard-Dolman test (H-D test) at distance 2.5 m after conducted full correction of subjects' refractive error respectly. Results: The means of KVA were $0.49{\pm}0.25$ for total subjects, $0.58{\pm}0.26$ for male, $0.40{\pm}0.22$ for female, and LogMAD (Log minimum angle of displacement) dynamic stereoacuities were $1.27{\pm}0.44$($28.44{\pm}25.03sec$ of arc) for total subjects, $1.28{\pm}0.44$($28.23{\pm}23.34sec$ of arc) for male, $1.27{\pm}0.45$($28.63{\pm}26.83sec$ of arc) for female. KVA showed a statistically significant difference between male and female (p=0.00), but dynamic stereoacuity was no significant difference (p=0.97). No significant correlation was present between KVA and dynamic stereoacuity (r=0.03). Also there were no significant differences in the dynamic stereoacuity of the three group which were classified according to the low, middle, high range of KVA (p=0.99). The anisometropia were less than 1 D and over 1 D when divided into two groups, KVA and dynamic stereoacuity showed no significant difference between each (p=0.11, p=0.99). There was no significant correlation between anisometropia and KVA (r=0.33), dynamic stereoacuity (r=0.18) but the correlation between KVA and anisometropia revealed more higer than between dynamic stereoacuity and anisometropia. Conculsions: The KVA for adults showed a significant difference between male and female and male was higher than female for KVA. The dynamic stereoacuity due to the KVA, the KVA and dynamic stereoacuity due to anisometropia were not significant differences between each and also were not great correlations.

A Comparison of Refractive Components in Anisometropia and Isometropia (굴절부등안과 동등안의 양안 굴절요소 차이 비교)

  • Shim, Hyun-Seog;Shim, Jun-Beom;Kim, Eun-Suck
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.187-193
    • /
    • 2011
  • Purpose: This study was to compare differences between both eyes in corneal powers, axial lengths, anterior chamber depths in anisometropia and isometropia, and to investigate the relationship between anisometropia and refractive components. Methods: The subject was a total of 83 patients, anisometropia 45 patients (90 eyes) and isometropia 38 patients (76 eyes) from 2.7 to 15.3 years old, prescribed eyeglasses and contact lenses by refraction from July 2010 to August 2010 in Gwangju City B eye clinic. Axial length, anterior chamber depth, corneal curvature, and corneal refractive power were measured using IOL Master. Refractive error was measured using an Auto-refractometer. Results: Anisometropia was a statistically significant difference in axial length, binocular refractive components, refractive error, and axial length, Axial length/corneal radius (AL/CR) ratio showed a statistically significant difference in anisometropia and isometropia. The major cause of anisometropia all 45 subjects was the axial length. Among the refractive components axial length, AL/CR had a strong correlation, but corneal refractive power had no correlation. Anterior chamber depth had a weak correlation. Conclusions: This study found that refractive error was the most axial ametropia caused by the axial length. The main cause of anisometropia was the axial length, but refractive components had a weak correlation.

The effect of brightness contrast on resolving the correspondence problem (상의 대응 문제 해결에 미치는 밝기 대비의 영향)

  • 감기택;정찬섭
    • Korean Journal of Cognitive Science
    • /
    • v.12 no.4
    • /
    • pp.49-56
    • /
    • 2001
  • When multiple features are presented in the image the computational models for stereopsis select the most activated matches through the excitatory and inhibitory interactions among all possible matches. Using the random-dot stereogram with two surfaces. we investigate whether human binocular mechanism selects the most activated matches. The dots consisting a surface lying in a fixation plane were selected randomly while each of the dots consisting the other surface was paired with each of the original dots in the following manner. After finding the position of each dots in the original random pattern we placed an additional dot to the left and to the right of the original position in each of the left and right image of a stereogram respectively. The luminance of additional dots was varied while that of the original random dots was fixed so that the hypothetical matches presumably could be activated differently. Across the luminance condition the depth of each surface was measured to examine whether matches to be selected were changed depending on the activation level of possible matches. When the luminance of two patterns was within 30% of one another observers perceived an opaque surface. Beyond this value two transparent surfaces were seen with the magnitude of perceived depth varying with relative luminance of two patterns. When original pattern was brighter one additional surface was perceived at the depth corresponding to the disparity of original pattern. When original dot was dimmer. however the depth of an additional surface corresponded to the disparity of newly introduced pattern. These results suggest that there are dynamic interactions within the matching process whereby highly activated matches inhibit weaker one.

  • PDF

Assessment of Dynamic Stereoacuity of Adults in their 20s' with Howard-Dolman Test (하워드-돌먼 입체검사를 이용한 20대 성인의 동적 입체시 평가)

  • Shim, Hyun-Suk;Choi, Sun-Mi;Kim, Young-Cheong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.1
    • /
    • pp.61-66
    • /
    • 2015
  • Purpose: In this study, dynamic stereoacuity of 20s' adults were measured by using the Howard-Dolman test(H-D TEST, Bernell, U.S.A), and compared of male and female. And the correlation between dynamic stereoacuity and PD(pupillary distance), and between dynamic stereoacuity and anisometropia caused by difference in the spherical refractive power of the left and right eyes were analyzed. Methods: The mean age of $22.68{\pm}0.50$(20~29)years old, 20s' 63 adults (30 male, 33 female) were conducted for this experiments. After the full correction of subject's refractive error, dynamic stereoacuity was measured 5 times for 1 subject at 2.5 m distance using the H-D test. at 2.5 distance. Results: The mean of dynamic stereoacuity was $28.44{\pm}25.03$ sec of arc for total subjects, $28.23{\pm}23.34$ sec of arc for male, and $28.63{\pm}26.83$ sec of arc for female. In the dynamic stereoacuity classified by the range of inter-pupil distance (IPD), the dynamic stereoacuity was $33.87{\pm}18.53$ sec for the IPD being under 59.80 mm, $26.24{\pm}25.26$ sec of arc for 59.81~66.15 mm, $34.60{\pm}25.65$ sec of arc for over 66.15 mm. However, there were no significant differences between 3 groups (P=0.73, r=0.03). In dynamic stereoacuity classified by the refractive error difference between two eyes, dynamic stereoacuity was $26.81{\pm}24.86$ sec of arc for the under 1 D, $41.45{\pm}24.18$ sec of arc for over 1 D, and there was no significant difference between two groups (P=0.15, r=0.15). Conclusions: Dynamic stereacuity by the H-D test in 20s adults showed that there was no significant differences between male and female, and PD and anisometropia did not have a significant impact upon the dynamic stereoacuity.

Average Correction for Compensation of Differential Column Shortening in High-rise Buildings (이동 평균법을 이용한 고층 건물의 부등축소량 보정 기법)

  • Park, Sung-Woo;Choi, Se-Woon;Park, Hyo-Seon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.4
    • /
    • pp.395-401
    • /
    • 2010
  • The vertical members of structures are shortened as time goes on. Because structures have been high-rising and atypical there should be different axial loads among vertical members and it causes differential column shortenings. The differential column shortening add stresses to connections, make slab tilt, and damage to non-structural components. To reduce these influences compensation is need. The rational compensation means the exact expectation of amounts of column shortenings and the reasonable corrections. The expectation of column shortenings are more exact as researched, however, there is little research about the compensation. This paper presents the average correction method and the constraints for differential column shortenings considering errors due to the construction precision. The relations between constraints and the number of correction groups give an objective criterion for decision of constraints.

Stereoscopic 3-D shape constancy (입체시에 근거한 3차원 모양 항상성의 검증)

  • 이형철
    • Korean Journal of Cognitive Science
    • /
    • v.10 no.3
    • /
    • pp.17-28
    • /
    • 1999
  • Systematic distortions in perceived 3-D shape were obtained for elliptical and parabolic stereoscopic surfaces viewed at different distances under full and reduced cue conditions. In both conditions of Experiments 1 and 3, elliptical hemi-cylinders a appeared near veridical at the 45 cm viewing distances and flattened up to 74% of veridical at 135 cm. In Experiment 2, under full cue conditions, parabolic hemi-cylinders a appeared stretched to 118% of veridical at 45 cm, near veridical at 90 cm, and flattened to 85% of veridical at 135 cm. Under reduced cue conditions parabolas appeared flatter overall: veridical curvature was obtained at 45 cm viewing distance with flatness increasing to 68% of veridical at 135 cm. Results support a scaling explanation of perceived 3-D shape from disparity and rule out the alternative hypothesis that disparity curvature, an optical invariant, provides information for the direct perception of 3-D s shape.

  • PDF

Analysis on Vegetation Effect through Numerical Simulation of Non-Uniform Flow at Downstream of Hapcheon Dam (합천댐 직하류에서 부등류 수치모의를 통한 식생의 영향 분석)

  • Park, Su Hwan;Kang, Tae Un;Jang, Chang-Lae;Kim, Zoo Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.238-238
    • /
    • 2022
  • 합천댐의 건설 이후, 댐직하류 구간에서는 10년 동안의 방류량 감소와 기후변화로 인한 강우패턴의 변화로 하도식생의 활착이 발생하여 식생이 증식하고 밀도가 점차 증가하고 있다. 식생밀도의 증가는 흐름에 대한 항력을 증가시켜 유속을 감소시키고 수심을 증가시킨다. 이는 통수능 저하를 초래하며, 홍수 시 수위증가에 따른 홍수범람의 위험성 증가시킨다. 따라서 식생영향에 대한 심화적인 이해를 제고하여 적절한 식생관리대책을 구축할 필요가 있다. 본 연구에서는 이러한 필요성에 맞추어 식생대 영향에 따른 흐름의 변화를 예측모의하여 흐름과 식생대의 상호작용에 대한 분석을 수행하였다. 이를 위해 2차원 흐름모형인 Nays2D를 이용하여 합천댐 직하류 구간을 대상으로 식생밀도의 변화에 따른 흐름의 변화를 부등류를 기반으로 모의하였다. 상류단의 경계조건은 162.99 m3/s(실운영 방류량), 995 m3/s(2년빈도 댐 조절 방류량), 2670 m3/s(100년빈도 댐 조절 방류량)로 3개의 유량으로 구분하여 모의하였다. 식생의 특성은 현장조사를 통해 밀도를 산정하여 수치모의에 적용하였다. 식생밀도는 4가지로 구분하여 모의시나리오를 구축하였으며 현장조사를 통해 산정된 2021년도 식생밀도를 기준으로 식생밀도를 증감하여 수치모의를 수행하였다. 수치모의 조건은 2021년 식생현황, 식생개선, 식생존치, 전벌채로서 식생개선의 경우, 2021년 식생밀도의 0.5배로, 식생존치의 경우, 식생밀도를 2배로 적용하였다. 전벌채는 식생이 없는 것으로 가정하였다. 수치모의 결과, 식생개선이 2021년 식생현황과 식생존치보다 상대적으로 수심이 낮게 나타났다. 식생을 전벌채한 경우, 식생이 존재하는 조건보다 수심이 낮고 유속이 빠르게 나타났으며 특히, 만곡부의 외측에서는 2차류의 발달로 흐름이 집중되었다. 이를 통해 식생개선의 경우, 식생현황과 식생존치보다 홍수범람의 가능성이 적을 것으로 판단되며 전벌채의 경우, 만곡부 외측에서 2차류 발달에 의한 세굴을 야기하여 제방의 안정성에 영향을 줄 것으로 예측된다. 본 연구는 댐 직하류에 식생대 밀도변화가 흐름변화에 미치는 영향을 분석한 수치모의 사례로서 이는 추후 식생을 고려하는 하천관리방안을 수립 시, 식생관리방법에 대한 근거자료로 활용될 수 있을 것으로 기대된다.

  • PDF

Design of Road Surface Drainage Facilities Based on Varied Flow Analysis (부등류 해석을 기반으로 한 노면배수시설 설계)

  • Ku, Hye-Jin;Kim, Jin-Soo;Park, Hyung-Seop;Jun, Kyung-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.12
    • /
    • pp.1173-1185
    • /
    • 2008
  • The design methods of the road surface drainage facilities were compared for the improvement of design method. We have developed four computational design models classified by the methods to determine the duration of design rainfall and to analyze the flow of a linear drainage channel. The critical duration was determined by assuming the critical duration to be 10 minutes or by finding the duration of design storm being similar to the travel time of flow by trial and error. The flow of a linear drainage channel was analyzed as the uniform flow or the varied flow. The design models were applied to the artificial road surface drainage facilities with various channel slopes and road shoulder slopes. If the rainfall intensity of the 10 minutes duration was applied, the outlet spacing obtained from the design based on the varied flow analysis was larger than the uniform flow analysis only when the channel slope and the road shoulder slope was small. On the other hands, if the duration of design rainfall was determined by calculating the travel time, the varied flow analysis brought about larger outlet spacing than the uniform analysis for all conditions. However, the model of the critical duration concept and the varied flow analysis resulted in smaller outlet spacing than the current design method employing the rainfall of 10 minutes duration and the uniform flow analysis.

Cracking Behavior of Concrete Bridge Deck Due to Differential Drying Shrinkage (교량 바닥판 콘크리트의 부등건조수축 균열특성에 관한 연구)

  • Yang, Joo Kyoung;Lee, Yun;Yang, Eun Ik;Park, Hae Geun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4A
    • /
    • pp.329-335
    • /
    • 2009
  • The purpose of this study is to provide the efficient method and guideline of controlling the cracking in bridge deck concrete due to differential drying shrinkage. Drying shrinkage cracking is mainly influenced by the moisture diffusion coefficient that determines moisture diffusion rate inside concrete structures. In addition to the diffusion coefficient, surface coefficient of concrete surface and relative humidity of ambient air simultaneously affect the moisture evaporation from concrete inside to external air outside. Within the framework of cracking shrinkage cracking mechanism, it is necessary to conceive the numerical analysis, which involves these three influencing factors to predict and control the shrinkage cracking of concrete. In this study, moisture diffusion and stress analysis corresponding to drying shrinkage on bridge deck are performed with consideration of diffusion coefficient, surface coefficient, and relative humidity of ambient air. From the numerical results, it is found that cracking behavior due to differential drying shrinkage of bridge deck concrete shows different feature according to three influencing factors and the methodology of controlling of drying shrinkage cracks can be suggested from this study.