• Title/Summary/Keyword: 볼트체결부

Search Result 104, Processing Time 0.023 seconds

Compressive Stress Distribution of High Tension Bolted Joints (고장력 볼트 이음부의 내부 압축응력 분포)

  • Kim, Sung Hoon;Lee, Seung Yong;Choi, Jun Hyeok;Chang, Dong Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.2 s.31
    • /
    • pp.171-179
    • /
    • 1997
  • The high-tension bolted joints are clamped by the axial force which approaches the yielding strength. The introduced axial force is transmitted to the connection members pass through washer. The transferred load in connections is balanced to the compressive stress of plates, axial force in bolts and the external loads. In this mechanism, the compressive stress and slip load we dominated by the effective stiffness of bolted joints and plates. In general the effective stiffness is specified to product to the effective area and elasticity modulus in connections. In this reason, the conic projection formular which is assumed that the axial force in bolts is distributed to the cone shape and that region is related to the elastic deformation mechanism in connections, was proposed. But it conclude what kind of formula is justified. Therefore in this paper, the fatigue tests are performed to the high tension bolted joints and inspected to the phase on the friction face. And using the FEM and numerical method, it is analyzed and approximated to the compressive stress distribution and its region. Moreover, it is estimated to the effective area and to the relation the friction area to the effective compressive distribution region.

  • PDF

A Study on the Fracture Resistance Characteristics of Post-Installed Anchor (후설치 앵커볼트의 파괴저항 특성에 관한 연구)

  • Kim, Doo Hwan;Hwang, Yun Sung;Cha, Young Min;Song, Kwan Kwon;Choi, Kyung Gyp
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.156-156
    • /
    • 2011
  • 중량물 혹은 철골구조물 등을 고정시키는데, 건축구조물의 철골기둥, 터빈 제네레이터 기기등을 콘크리트 구조물에 부착시키기 위해 널리 쓰인다. 1990년대 들어 국내 건물의 리모델링, 보수 및 유지관리의 증가에 따라 앵커의 사용량도 현저히 증가하고 있으나 대부분 고가의 외국산제품을 수입하고 있다. 현재 국내외에 주로 시행되는 앵커타입은 마찰형 앵커이나 마찰형 앵커와 달리 지압형 앵커의 경우, 외국에서는 이미 그 유효성에 대한 인식이 널리 퍼져있으며 각국의 지반조건에 적합한 설계법이 개발되었다. 그러나 국내의 경우 이러한 연구가 미진한 실정이며 이에 대한 연구가 절실한 상황이다. 본 연구에서는 중량물앵커(Heavy Duty Anchor)의 인장시험을 실시하여 내력을 규명하고 도출한 결과를 기존 시험연구 결과와 비교분석하여 기 제안된 이론식들과 사업경제성에대해 보다 깊이있고 정확한 적용성을 입증하는데 본 연구를 수행하였다. 시험을 통한 저강도 파괴시험의 결과 구조부재의 접합부에서 각 시험체마다 뽑힘파괴가 발생하였으며, 뽑힘파괴가 발생한 시험체는 앵커강재의 파괴력 또는 콘크리트의 콘파괴를 발생시키기에는 앵커슬리브의 확장력이 작게 작용되었다. 그 결과, 콘파괴 대신 구조부재의 접합부에서 뽑힘파괴가 발생되었으며 이를 통해 설계시, 앵커의 안정성을 증가시키기 위해 구조부재의 접합부를 연성적이며, 부가여력을 충분히 지니도록 설계하는 것이 효과적인 것으로 나타났다. 고강도 파괴시험의 결과 콘파괴가 발생되었음을 알 수 있는데, 본 시험에 사용된 앵커의 경우 정착위치가 구조물의 연단 모서리 거리와 너무 근접하여 앵커의 내력이 감소하게 되어 콘크리트의 콘강도가 발생되기 전에 먼저 파괴되었다. 따라서 설계시, 앵커의 파괴강도를 증가시키기 위해 앵커의 정착위치를 고려한 설치를 통해 앵커체결과정에서 적정 연단거리를 확보하는 것이 효과적인 것으로 나타났다. 앵커볼트 최소간격과 연단거리에 따른 파괴시험결과 앵커볼트의 간격이 허용범위 내에서 넓어질수록 불균등 부반력의 차는 감소하였으며, 최대 부반력도 감소하였다. 따라서 앵커의 파괴저항강도를 증가시키기 위해서는 허용범위 내에서 앵커볼트의 설치간격을 증가시키는 것이 효과적인 것으로 나타났다.

  • PDF

Design of the Structural Connection for Lightweight Structure Application (경량구조 적용을 위한 구조 접합부 설계)

  • Nam, Byung Hyun;Choi, Jinnil
    • Journal of the Korea Society for Simulation
    • /
    • v.29 no.2
    • /
    • pp.95-103
    • /
    • 2020
  • The structural connection design for lightweight structure application is presented in this paper. Modeling of the welding zone and the bolted connection are suggested. For reliability verification of the established models, nonlinear analysis is performed and comparisons are made with the experimental data showing good agreement. Through comparison study, suitable welding method for structure materials is investigated. Also, stability analysis is performed by fracture load simulation for different number and position of bolts. Finally, based on the structural connection models, the lightweight structure is modeled and structural analysis was performed. Stability analysis of structural connection for lightweight structure design, through combination of welding and bolting process, showed a 31.4% decrease in the maximum stress compared to the structure without the structural connections. Importance of structural connection design is highlighted for lightweight structure stability analysis.

Experimental Study on the Behavior of Building Hardware with Joint Details (접합 방법에 따른 하지철물 구조물의 거동에 관한 실험적 연구)

  • Hong, Seonguk;Kim, Seunghun;Baek, Kiyoul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.190-198
    • /
    • 2018
  • In recent years, non-welded building hardware has been installed by bolt assembly is used. The non-welded building hardware method can reduce accidents caused by welding, and can be constructed by bolt assembly, which can reduce labor costs and shorten the construction period. However, there is a need for a method to compensate for the occurrence of buckling at the time of construction. The purpose of this study is to evaluate the behavior of joints between steel pipe and fastener and to evaluate the behavior of joints of non-welded and welded hardware frame. As a result, it was found that the foundation steel structure without welded joints was deformed to a rotation angle of member much larger than the allowable interlayer displacement angle 0.01 to 0.02 required according to the seismic load rating in the seismic load resistance system.

Development of Connection Details for a Double Split Tee Connection Without a Shear Tab (전단탭이 없는 상·하부 스플릿 티 접합부의 접합부상세 개발)

  • Yang, Jae Guen;Kim, Yong Boem
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.1
    • /
    • pp.53-64
    • /
    • 2016
  • The double split tee connection, a type of beam-to-column moment connection, exhibits different behavioral characteristics according to changes in the thickness of the T-stub flange, the gauge distance of the high-strength bolt, and the number and diameter of high-strength bolts. In general, the double split tee connection is idealized and designed so that a T-stub fastened to the top and bottom supports a flexural moment, and a shear tab supports a shear force. However, if the double split tee connection is applied to low-and medium-rise steel structures, the size of the beam member becomes small, and thus the shear tab cannot be bolted to the web of a beam. In this regard, this study was conducted to propose connection details to ensure that the double split tee connection with a geometric shape can display sufficient shear resisting capacity. To this end, experiments were conducted using full-scale specimens for the double split tee connection.

Wing-Fuselage Joint Design Improvement Using Nonlinear Analysis Considering Contact (접촉을 갖는 날개-동체 조인트의 비선형 해석을 통한 설계 개선)

  • Kim, Gwang-Su;Yun, Se-Hyeon;Sim, Jae-Yeol;Lee, Yeong-Mu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.2
    • /
    • pp.108-114
    • /
    • 2002
  • In this paper, nonlinear finite element analysis is performed to ensure structural safety and to suggest the design improvement of wing-to-fuselage joint of the KSR-III rocket. In the joint, wings are attached to fuselage by fitting wing attachment part into the groove on the fuselage frame, and load transfer between wing and fuselage frame is accomplished mainly throug the contact of two members as well as fastening bolts. The careful finite element modeling has been proposed for the purpose of analyzing problems with relatively complicated load path. The detailed bolt modeling is conducted and GAP elemets are used to simulate contact problem between joined members and bolts. The suggested design improvement is verified by structural testing and the analysis results are compared with test results.

Experimental Study on the Load Transfer Behavior of Steel Grid Composite Deck Joint (격자형 강합성 바닥판 이음부의 하중전달 거동에 관한 실험적 연구)

  • Shin, Hyun-Seop
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.10-21
    • /
    • 2014
  • The joint of prefabricated steel grid composite deck is composed of concrete shear key and high-tension bolts. The flexural and shear strength of the joint were experimentally evaluated only by the bending and push-out test of the joint element. In this study the lateral load transfer behavior of the joint in deck structure system is experimentally evaluated. Several decks connected by the joint are prefabricated and loaded centrically and eccentrically. In the case of centrically loaded specimens, the analysis results show that for the same loading step the rotation angle of the joint with 4 high-tension bolts is larger than the case of the joint with 9 high-tension bolts. Consequently, flexural stiffness of deck and lateral load transfer decrease in the case of specimen with 4 high-tension bolts. But, in the case of eccentrically loaded specimens, it is found that there are no significant differences in the load transfer behavior. The further analysis results about the structural behavior of the joint show that lateral load transfer can be restricted by the load bearing capacity of the joint as well as punching shear strength of the slab. Furthermore, considering that high-tension bolts in the joint didn't reach to the yielding condition until the punching shear failure, increase in the number of high-tension bolts from 4 to 9 has a greater effect on the flexural stiffness of the joint and deck system than the strength of them.

A Study on the strength of the Bolted Joint & Pin Joint with Hole Clearance (원공공차를 가진 볼트 조인트와 핀 조인트의 강도평가에 관한 연구)

  • Jeong, Kang-Woo;Choi, Jin-Ho;Kweon, Jin-Hwe
    • Composites Research
    • /
    • v.25 no.6
    • /
    • pp.186-190
    • /
    • 2012
  • With the wide application of fiber-reinforced composite material in aero-structures and mechanical parts, composite joint have become a very important research area because they are often the weakest sites in composite structures. In this paper, the failure strengths of the bolted joint and pin joint which have variable hole clearance were evaluated and compared. From the tests, the first failure loads of the bolted joint and pin joint with $880{\mu}m$ hole clearance have decreased by 24.2 % and 51.3 % compared to those of joints with $0{\mu}m$ hole clearance, respectively. Also, the failure index of the joints were calculated by the finite element method and compared with experimental results.

Effect of Clearance on Clamping Characteristics of Segmented Nuts in Pyrotechnic Separation Nut (파이로테크닉 분리 너트 내부 분할 너트 체결 특성에 대한 틈새의 영향)

  • Woo, Jeongmin;Kang, Dahoon;Choi, Jaeyoung;Kim, Jeong Ho;Cho, Jin Yeon;Jang, Seung-gyo;Yang, Hee Won
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.12
    • /
    • pp.994-1003
    • /
    • 2018
  • The clamping characteristics of segmented nuts in pyrotechnic separation nut are investigated using finite element analysis. When the segmented nuts are used to clamp objects, a constraint cylinder is necessary to prevent the segmented nuts from spreading out to the radial direction. During the manufacturing process, a clearance is usually introduced between the outer diameter of the segmented nuts and the inner diameter of the constraint cylinder. Therefore to find out the effect of the clearance, proper finite element modeling method is suggested to describe the clamping procedure appropriately. In addition, finite element analysis with the clearance of 0.00, 0.03, 0.06, and 0.10 mm are performed. From the analysis results, the clamping characteristics of segmented nuts are investigated according to the clearance, and several factors which should be considered to design a reliable pyrotechnic separation nut are figured out.

A case study on the bolt failure of the moving parts of a marine diesel engine (선박용 디젤기관의 운동부 볼트 손상사례에 대한 연구)

  • Kim, Jong-Ho;Lee, Jae-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.118-124
    • /
    • 2017
  • To investigate and analyze the cause of the failure of the connecting rod bolt and the crank pin bearing bolt of the diesel engine of this study, the following results were obtained through site surveying, the investigation of literature referring to similar failures, testing and inspection of the fracture surface, and the experience of the researchers. The fractured crank pin bearing bolt of the diesel engine is estimated to be damaged later than the connecting rod bolt. From the shape of fracture surface, it is evident that the failed connecting rod bolt is fractured by fatigue failure due to abnormally repeated loads (e.g. loosening of the connecting bolt, etc.), and is not failed by brittle fractures due to the impact load. The surface of the U-nut on the fractured connecting rod bolt has been worsening due to the improper use of lubricant (agent for prevention of thread fixing) and no usage of separating the each connecting rod on each cylinder. Moreover, there is the possibility that those poor surface conditions of the fractured connecting rod bolt have affected the failure of the connecting rod bolt of the main engine. And it could be assumed that the mechanical characteristic and manufacturing process of the failed connecting rod bolt and crank pin bearing bolt, which were made by a domestic company, conform to the design requirements for those bolts.