• Title/Summary/Keyword: 복합 센서

Search Result 820, Processing Time 0.033 seconds

Shape Monitoring of Composite Cantilever Beam by Using Fiber Bragg Grating Sensors (광섬유 브래그 격자 센서를 이용한 복합재 외팔보의 형상 모니터링)

  • Lee, Kun-Ho;Kim, Dae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.7
    • /
    • pp.833-839
    • /
    • 2013
  • In this study, an experiment was performed to monitor the two-dimensional shape of a cantilever composite structure using fiber Bragg grating (FBG) sensors. To monitor the shape of a composite structure, a deflection equation developed by NASA was applied and a composite beam attached to three FBG sensors was used. In the experiment, the shape of the composite beam was successfully estimated and an error was evaluated by comparing a real deflection. The error increased with real deflection; therefore, it was compensated by using the linear relationship between the error and the real deflection. After compensating the error, the measured deflection shows good agreement with the real deflection. Finally, the experiment shows that the FBG sensor and the deflection equation are suitable for monitoring the deflection curve of the beam structure with compensation of the error.

A study on the application of optical fiber sensors to smart composite structures (지능형 복합재 구조물에 대한 광섬유센서의 적용에 관한 연구)

  • Jang, Tae-Seong;Kim, Ho;Lee, Jung-Ju
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.6
    • /
    • pp.15-24
    • /
    • 1996
  • In this study, as a part of the basic study for the application of optical fiber sensors to smart composite structures, the integrity of optical fiber sensors embedded within the composite structures was examined and then the laser signal transmitted through optical fiber sensors during the deformation of host structures was investigated. Firstly, it was found that bending test could be substituted for tensile test by comparing cumulative failure distribution based on weakest link theory and introducing the correction factor. Weibull parameters were obtained through the experiments and the correction factor was found to be applied to cumulative failure distribution derived from bending test. The integrity of embedded optical fiber sensors due to the thermal effect was evaluated by the comparison of the mean tensile strengths of cured and uncured optical fibers. Secondly, relationships between stress-strain curve obtained in tensile test of composite laminate and the intensity of laser signal transmitted through embedded optical fibers were examined and the possibility of the effective damage detection using optical fiber sensors was studied.

  • PDF

Analysis on Mapping Accuracy of a Drone Composite Sensor: Focusing on Pre-calibration According to the Circumstances of Data Acquisition Area (드론 탑재 복합센서의 매핑 정확도 분석: 데이터 취득 환경에 따른 사전 캘리브레이션 여부를 중심으로)

  • Jeon, Ilseo;Ham, Sangwoo;Lee, Impyeong
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.3
    • /
    • pp.577-589
    • /
    • 2021
  • Drone mapping systems can be applied to many fields such as disaster damage investigation, environmental monitoring, and construction process monitoring. To integrate individual sensors attached to a drone, it was essential to undergo complicated procedures including time synchronization. Recently, a variety of composite sensors are released which consist of visual sensors and GPS/INS. Composite sensors integrate multi-sensory data internally, and they provide geotagged image files to users. Therefore, to use composite sensors in drone mapping systems, mapping accuracies from composite sensors should be examined. In this study, we analyzed the mapping accuracies of a composite sensor, focusing on the data acquisition area and pre-calibration effect. In the first experiment, we analyzed how mapping accuracy varies with the number of ground control points. When 2 GCPs were used for mapping, the total RMSE has been reduced by 40 cm from more than 1 m to about 60 cm. In the second experiment, we assessed mapping accuracies based on whether pre-calibration is conducted or not. Using a few ground control points showed the pre-calibration does not affect mapping accuracies. The formation of weak geometry of the image sequences has resulted that pre-calibration can be essential to decrease possible mapping errors. In the absence of ground control points, pre-calibration also can improve mapping errors. Based on this study, we expect future drone mapping systems using composite sensors will contribute to streamlining a survey and calibration process depending on the data acquisition circumstances.

A Study on the Step-Up Converter with the New Topology Method (내구성이 개선된 발전용 가스터빈 온도센서 개발에 관한 연구)

  • Lee, Young-Jun;Jung, Hai-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.6
    • /
    • pp.1175-1186
    • /
    • 2020
  • In this study, the problem is analyzed, and methods of improvement are presented. For evaluating the performance of the proposed EGT sensor, a complex environment test equipment has been developed to test both high temperature and vibration conditions at the same time. This equipment evaluates the accuracy and response time of the EGT sensor. In the results of the comparison test of the complex environment test equipment of heat and vibration, the existing sensor showed a carbonization problem, and the proposed sensor showed no problem. Therefore, it is expected that the improved EGT sensor will be able to be applied to various industrial fields, including gas turbines for power generation.

ROIC Technology Trends for Sensors (센서 ROIC 기술 동향)

  • Roh, T.M.;Jeon, Y.D.;Lyuh, C.G.;Cho, M.H.;Kim, Y.G.;Kwon, J.K.
    • Electronics and Telecommunications Trends
    • /
    • v.28 no.5
    • /
    • pp.83-92
    • /
    • 2013
  • IT 기술이 발달함에 따라 저전력, 초소형 센서노드를 설치하여 무인으로 정보를 얻을 수 있는 시스템의 도입이 점차 확대되는 추세이며, 이것을 위하여 온도, 습도, 가스 등 환경정보를 획득할 수 있는 센서뿐만 아니라 초소형 저전력 복합환경센서 ROIC(Read-Out Integrated Circuit)의 중요성이 증가하고 있다. 또한 휴대폰, 노트북, 스마트폰, 태블랫 PC 등의 모바일 IT 제품들은 빠르게 소형화, 슬림화, 저전력화 되고 있다. 이런 시스템의 요구에 따라 음향부품도 기본적인 음향감지/출력 성능 이외에 크기 및 소모전력이 중요한 기능요소로 크게 부각되고 있으며, 이것을 위하여 소형화, 저가격화가 가능한 MEMS(Microelectromechanical Systems) 음향센서 및 ROIC 개발이 요구되고 있다. 따라서 본고에서는 복합환경센서 ROIC 및 MEMS 마이크로폰 ROIC의 기술동향 등에 대해서 고찰하고자 한다.

  • PDF

Characteristics analysis and Fabrication of Integrated Piezoresistive Temperature & Humidity Sensors (압저항형 온·습도 복합 센서 제작 및 특성 분석)

  • Ryu, Jeong-Tak
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.2
    • /
    • pp.31-36
    • /
    • 2014
  • In this paper, we developed an intergrated piezoresistive temperature and humidity sensor using nano-technology, and evaluated the properties. In the measuring range from $20^{\circ}C$ to $80^{\circ}C$, output sensitivity of temperature was about 0.75mV/$1^{\circ}C$. Output sensitivity of humidity was about 1.35mV/10%(RH). Therefore, developed sensor suggests that it is possible applicable to the general residential environment.

Impact Damage Detection in a Composite Stiffened Panel Using Built-in Piezoelectric Active Sensor Arrays (배열 압전 능동 센서를 이용한 복합재 보강판의 충격 손상 탐지)

  • Park, Chan-Yik;Cho, Chang-Min
    • Composites Research
    • /
    • v.20 no.6
    • /
    • pp.21-27
    • /
    • 2007
  • Low-velocity impact damage in a composite stiffened panel was detected using built-in piezoelectric active sensor arrays. Using these piezoelectric active sensors, various diagnostic signals were generated to propagate Lamb waves through the structure and the responses were picked up to detect changes in the structure's vibration signature due to the damage. Three algorithms - ADI(Active Damage Interrogation), TD RMS (Time Domain Root Mean Square) and STFT (Short Time Fourier Transform) - were examined to express the features of the signal changes as one damage index. From damage detecting tests, two impact induced delaminations were detected and the location was estimated with the algorithms and diagnostic signals.

Low Velocity Impact Monitoring for a Composite Sandwich Beam Using Piezo Thin Film Sensors (압전필름센서를 이용한 복합재 샌드위치 보의 저속충격 모니터링)

  • Park, Chan Ik;Lee, Gwan Ho;Kim, In Geol;Lee, Yeong Sin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.2
    • /
    • pp.51-56
    • /
    • 2003
  • The piezoelectric thin film(PVDF: polyvinylidene fluoride) sensors having good dynamic sensing charachteristics can be used to monitor low vwlocit impact on composite structures. The impact response function for composite sandwich beam was derved. The impact tests at low energy without inducing damage were performed on the instrumented drop weight impact tester. The measured signals of PVDF sensors attached on the surface of the beam agreed well with the simulated signals. And the inverse technique was applied to reconstruct the impact forces from the PVDF sensor signals. Most of reconstructed impact forces showed good agreement with the measured forces. The comparison results showed that the piezoelectric thin film sensor can be used to monitor the low velocity impact on composite sandwich structures.

Development of Concentration Control System for Ni-W Alloy Plating Solution (니켈-텅스텐 합금 도금 공정액 농도 제어 시스템 개발)

  • Kong, Jung-Shik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.273-279
    • /
    • 2016
  • This paper deals with a control system with a concentration sensor for Ni-W alloy plating solutions. The printed circuit board market has increased with the development of the electronics industry. Gold consumption has also increased dramatically. Various studies of composite plating solutions have been conducted because of the expense of gold. In comparison, the development of sensors capable of measuring a composite plating solution in real-time is still insufficient. Furthermore, there are few systems that can measure and control the concentration of the solution precisely. This study developed a sensor and system to control the concentration of composite plating solution accurately. The sensors were developed based on a spectrophotometric method and a feedback control method was applied in this system.