• Title/Summary/Keyword: 복합 내구성능 저하

Search Result 33, Processing Time 0.034 seconds

A Compound Deterioration Assessment of Concrete Subjected In Freezing-Thawing and Chloride Attack (동결융해와 염해의 복합작용을 받는 콘크리트의 내구성능 저하 평가)

  • 고경택;김도겸;김성욱;조명석;송영철
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.4
    • /
    • pp.397-405
    • /
    • 2001
  • In clod weather regions, a strong seasonal wind brings sea salts to the land. In addition to it, recently, the spreading amount of deicing salts has increased numerously for purpose of removing snow and ice. Thus the salts environment around concrete structures becomes so severe that various damages of concrete due to applied salts will be brought up. Much of countries such as America, Europe etc. is carried out study for effects of deicing salts on concrete. However, there are not test methods for deterioration of concrete subjected to both freezing-thawing and chloride in Korea. In this study, we carried out test for the compound deterioration subjected to both freezing-thawing and chloride attack, to investigate the effects of sodium chloride on the deterioration of concrete. The test was performed to investigate the effects of cement type, strength and air content on the scaling deterioration of concrete. As a result, the scaling deterioration was accelerated in the presence of salts. And the resistance to scaling was strongly influenced by the type of cement, the strength and air content of concrete.

A Durability Assessment on Complex Deterioration of Concrete with Ground Granulated Blast-Furnace Slag Replacement (복합열화 환경하에서의 고로슬래그미분말 사용 콘크리트의 내구성능 평가)

  • Lee, Seung-Hoon;Kim, Hyung-Doo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.2
    • /
    • pp.171-175
    • /
    • 2010
  • This paper presents the experimental results of frost durability characteristics including freezing-thawing and de-icing salt scaling of the concrete for gutter of the road and marine structure. Mixtures were proportioned with the three level of water-binder ratio(W/B) and three binder compositions corresponding to Type I cement with 0%, 30% and 50% GGBS(Ground granulated blast furnace slag) replacement. Also, two different solutions of calcium chloride were used to evaluate their effect on the frost durability resistance. Specially, in case of complex of freezing and thawing with salt and carbonation, the deterioration of concrete surface is evaluated. Test results showed that the BFS30 and BFS50 mixture exhibited higher durability and lower mass loss values than those made with OPC mix and the use of GGBS can be used effectively in terms of economy and frost durability of the concrete to be in complex deterioration. Therefore, the resistance to complex deterioration with freezing-thawing was strongly influenced by the strength and the type of cement.

Assessment of Composite Cylinder Flaw for Compressed Natural Gas Vehicles (압축천연가스자동차용 복합재료용기의 외피손상결함 평가)

  • Kim, Young-Seob;Kim, Lae-Hyun;Yang, Dong-Ju
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2010.04a
    • /
    • pp.43-43
    • /
    • 2010
  • 국내에 천연가스버스가 보급된 이래 5차례의 용기파열 사고가 발생하였는데 그중 2005년 8월 전주 덕진충전소에서 발생한 용기파열사고는 CNG용기의 라이너를 감싸고 있는 복합재료가 손상되어 발생한 사고로 보고되었다. 복합재료용기의 외피손상이 원인이 되어 발생한 사고사례는 해외에서 약 13건이 보고되었다. CNG용기 외피손상은 용기룰 고정하는 스트랩과 밀접한 관련이 있다. 용기고정이 불완전하면 슬립이 발생하고 이는 복합재의 손상으로 이어진다. 본 연구에서는 ISO 19078, CGA C6.4 등 국제코드의 규정을 고려하여 국내에서 제조된 Type 2, 3, 4 용기와 외국에서 생산된 Type 3 용기를 대상으로 결함깊이, 길이, 넓이에 따른 복합재료 결함 내구성시험을 수행하여 CNG용기의 내구성능을 평가하였고, 시험과 동일한 조건으로 복합재료 손상결함 조건을 컴퓨터로 전산모사하여 시험결과의 타당성과 유효성을 비교 검증하였다. 실험결과, Type 2 용기의 경우, 11,250회의 최소반복가압 회수를 충족하였으나 외피손상부와 반복가압에 따른 실제누출부위가 일치하지 않아 실험조건을 달리한 추가실험이 요구되었다. Type 3 용기의 경우에는 복합재 결함부위와 누수부위가 일치된 시험용기의 수는 67%정도로, 복합재료 용기의 수명을 저하시키는 원인으로 라이너와 외피손상이 서로 밀접한 관련이 있음을 확인하였다. Type 4 용기는 국제기준에서 요구하는 반복횟수를 만족하였고, 손상깊이 0.75mm와 1.25mm에서 반복가압회수가 60,000회 이상이 되어도 누설이 발생되지 않았다. 이는 라이너의 재질이 폴리머로서 균일한데다 탄소섬유 복합재료층 위에 유리섬유 복합재료 층이 1.5mm 정도 추가로 적층되어 있어서 3등급의 손상결함(결함깊이 1.25mm)에서도 구조 층이 전혀 손상되지 않은 것으로 판단되며, 이는 Type 2 용기의 강재라이너나 Type 3의 알루미늄 라이너와 비교하여 Type 4 용기의 폴리에틸렌 라이너의 물성이 반복성능이 탁월함을 확인할 수 있었다.

  • PDF

Dyeing and Finishing on Interior Textile of Shipping (선박 인테리어용 섬유제품 적용 난연/내광 복합기능성 가공 연구)

  • Kim, Mi-Kyung;Jung, Dae-Ho;Kim, Young-Kuk;Ahn, Seung-Kuk
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2012.03a
    • /
    • pp.103-103
    • /
    • 2012
  • 크루즈 페리 선박의 인테리어 섬유 내장부품은 고도의 난연성과 내구성, 그리고 높은 수준의 감성과 심미적 기능을 만족하는 고기능성 소재로 구성된 섬유 복합체이다. 이는 화재, 전복 등 돌발 사고에 대하여 탑승자를 보호하고, 쾌적한 실내 분위기를 제공함으로서 안전운행을 유도하며, 높은 수준의 감성과 심미적 기능을 부여함으로서 품위와 가치를 증가시키는 기능이 있다. 난연기능이 부가된 난연사의 경우 복합가공 즉, 방오, 항균, 소취 기능을 추가 부여하게 되면 난연 기능이 급격히 저하되는 결정적인 단점이 있다. 이로 인해 가혹한 난연 성능이 요구되는 선박용 인테리어 섬유제품의 경우 그 규격을 만족하기란 쉽지 않기 때문에 원사제조에서부터 염색공정, 가공공정에 걸쳐 각 단위 공정별로 복합적으로 난연, 방오, 항균소취 기능들의 추가 보완이 필요한 실정이다. 또한 최근 사용자 입장에서는 용도에 따라 여러 가지 기능이 복합된 원단을 요구하는 사례가 많아지고 있는 실정이며, 많은 후가공 공정시 난연가공과 더불어 복합적으로 추가 가공시 난연성 저하 등의 문제가 있다. 본 연구에서는 선박용 인테리어 섬유제품의 Spec.을 만족시키기 위해 난연 직물의 염색 후가공에 적용되는 염조제 성능을 조사하고 고견뢰 및 균염을 만족하는 난연 내광 등의 복합기능성을 확보하기 위한 기초기술을 검토하였다.

  • PDF

Resistance to Freezing and Thawing of Concrete Subjected to Carbonation (탄산화를 받은 콘크리트의 동결융해 저항성)

  • Lee, Seung-Tae;Park, Kwang-Pil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.623-631
    • /
    • 2018
  • In this study, the degree of deterioration of concrete was investigated in the laboratory under conditions of carbonation and freeze-thaw cycling, which are the major causes of the deterioration of its performance. In this test, the carbonated concrete was subjected to combined freeze-thaw deterioration tests for up to 300 cycles, and its dynamic elastic modulus and compressive strength were measured. The evaluation of the effect of the water-binder ratio on normal concrete subjected to combined carbonization and freezing-thawing showed that its resistibility against such combined deterioration decreased more rapidly in the concrete with a water-binder ratio of 55 % compared with that having a water-binder ratio of 35 %. In the case where the concrete was blended with a mineral admixture consisting of fly ash and blast furnace slag at the same water-binder ratio, it showed an increase of its resistibility against combined deterioration.

An Experimental Study on the Durability Evaluation of Polymer Cement Restoration Materials for Deteriorated Reinforced Concrete Structures (성능저하된 철근콘크리트구조물 폴리머시멘트계 보수용 단면복구재의 내구성 평가에 관한 실험적 연구)

  • Kim, Moo-Han;Kim, Jae-Hwan;Cho, Bong-Suk;Park, Jong-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.1
    • /
    • pp.123-130
    • /
    • 2006
  • The duties of the restorative materials are to bear up against stress and to protect reinforcement corrosion. So the restorative materials are estimated by various kinds of strength, permeability and etc, But, in case of existing performance evaluation of restorative materials, because various deterioration factors are separately acted, the system of performance evaluation is different from that of combined deterioration of real structure and it is difficult to evaluate the exact performance of restorative materials. In this study, to evaluate Performance of restorative materials, we compare their korea standard properties in terms of compressive and bending strength and permeability of water and air with real durability for carbonation, salt damage and actual reinforcement corrosion like ratio of corrosion area. weight reduction and corrosion velocity of steel bar under environment of combined deterioration. The results showed that strength and permeability of restorative materials are similar but their resistance to carbonation, salt damage and actual reinforcement corrosion are very different.

Comparative Study on Freeze-Thaw Durability of General Concrete and Pavement Concrete (일반콘크리트와 포장콘크리트의 동결융해 내구성에 대한 비교 연구)

  • Kim, Hyun-Joong;Lee, Beung-Duk;Lee, Ju-Gang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.561-564
    • /
    • 2008
  • Concrete scaling is the progressive surface deterioration of susceptible subjected to freeze-thaw cycling in the presence of moisture. Particularly, it has been recognized that chlorides present in deicing agents can significantly increase concrete surface scaling. Domestic area of most be happened chloride deicer damage. Because daily mean temperature is below 0$^{\circ}C$ from the area of domestic most. Use of deicing chemicals has been and will continue to be a major part of highway snow and ice control methods. Chloride-containing chemicals such as calcium chloride or rock salt are main deicers for the road. Extensive use of chloride deicers is, however, not only the source of substantial cost penalties due to their corrosive action and ability to deterioration roadway surface materials but also the source of environmental damages. In this study, Use of (40, 27, 21MPa) pavement concrete analyze freeze-thaw test and scaling on the chlorides present.

  • PDF

Properties on the Freeze-Thaw of Concrete Subjected to Seawater Attack (해수의 영향을 받은 콘크리트의 동결융해 특성)

  • Park, Kwang-Pil;Kim, Seong-Soo;Lee, Seung-Tae;Kim, Jong-Pil;Jung, Ho-Seop
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.1
    • /
    • pp.23-30
    • /
    • 2011
  • In this study, deterioration degrees of concrete were investigated at laboratory under seawater attack and cycling freeze-thaw, which are major durability performance deterioration factors of concrete. Deteriorations of mixed concrete using Portland & blended cement were examined by instrumental analysis of changes in relative dynamic modulus of elasticity and compressive strength. After 520 cycles of freeze-thaw, relative dynamic modulus of elasticity and compressive strength of concrete mixed with normal Portland and LHC over 75% showed relatively low resistance of approximately 44% of those values of SRC. Concrete replaced with 50% fine powder of blast furnace slag showed the most excellent freeze-thaw resistance among the tested blended cement concrete.

The Combined Effect of Concrete Environment and High Temperature on Interlaminar Shear Strength of FRP Reinforcement (콘크리트 환경과 고온의 복합환경이 FRP 보강근의 계면전단성능에 미치는 영향)

  • Moon, Do-Young;Oh, Hong-Seob
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.6
    • /
    • pp.749-756
    • /
    • 2011
  • Most experimental studies on durability of FRP reinforcements subjected to high temperature have focused on the effect of high temperature only on tensile properties. But FRP reinforcement used in newly constructed concrete structure is first degraded by moisture and alkaline environment of concrete. When the structure is subjected to fire, the degraded FRP reinforcement is exposed to high temperature. Therefore, the effects of concrete environment and high temperature should be simultaneously considered for evaluation of FRP reinforcement damaged by fire. In this study, FRP reinforcements submerged in simulated solutions of pH 12.3 and 7 for extended period of time were subjected to temperatures of $60^{\circ}C$, $100^{\circ}C$, $150^{\circ}C$, and $300^{\circ}C$ to be examined. In order to investigate the effect of the high temperature, interlaminar shear strengths were measured and compared to those of control ones. The experimental results demonstrated that the combined effect of concrete environment and high temperature on properties of FRP reinforcement was more significant than the effect of high temperature or concrete environment solely.