• Title/Summary/Keyword: 보호앞치마

Search Result 6, Processing Time 0.021 seconds

A Study of Changes in the Primary Dose Penetrating the Protective Apron on SID in X-ray Radiography (X선촬영에서 보호앞치마를 투과한 1차 선량의 SID별 변화)

  • Choi, Seong-Kwan
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.501-507
    • /
    • 2016
  • This study is to figure out the amount of primary X-ray generated in SID 50cm, 1m, and 2m penetrating protective aprons in X-ray radiography for hands, skull, and lumbar spine. Results are as follows: Firstly, the exposure dose of primary X-ray which is low such as that of hand X-ray may be reduced by 270 times if protective aprons are worn, but it still slightly penetrates 0.3mm thick Pb protective aprons at SID 50cm, 1m, and 2m. Secondly, the exposure dose of primary X-ray which is moderate such as that of skull X-ray may be reduced by 22 times if protective aprons are worn, but it still fairly penetrates 0.3mm thick Pb protective aprons at SID 50cm, 1m, and 2m. Thirdly, the exposure dose of primary X-ray which is very high such as that of lumbar spine X-ray may be reduced by 13 times if protective aprons are worn, but it still penetrates a lot 0.3mm thick Pb protective aprons at SID 50cm, 1m, and 2m. Therefore, people in X-ray room should not only wear protective aprons at any spaces that the primary X-ray can reach, but also need to stand behind the thick Pb shield to protect the body if it is inevitable to stay in the room.

A Study on Protection Performance of Radiation Protective Aprons classified by Manufacturers and Lead Equivalent using Over Tube Type Fluoroscopy (Over Tube Type의 투시촬영장치를 이용한 제조사별, 납당량별 엑스선방어 앞치마의 Protection 성능 평가에 관한 연구)

  • Song, Jong-Nam;Seol, Gwang-Wook;Hong, Seong-Il;Choi, Jeong-Gu
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.135-141
    • /
    • 2011
  • If protective performance of apron cannot be good, radiation exposure of an guardian or a patient, a person engaged in radiation related industry cannot rise. Therefore, It will be evaluated protection performance to radiation protection aprons by manufacturers and lead equivalent more than 0.25mm lead equivalent. And, will show in the direction of application to clinic. The new aprons by manufacturers(H, X, I, J company) and lead equivalent(0.50mmPb, 0.35mmPb, 0.25mmPb) measured transmitted dose rate and shielding rate, uniformity under fluoroscopy and general radiography using to fluoroscopy system and digital radiography system, x-ray multifunction meter. The shielding rate measurement results, 0.5mmPb apron was Shielding rate of apron of a I company(fluoroscopy : 97.96%) was the best under six companies, and shielding rate of apron of a J company(fluoroscopy : 96.25%) was worst. 0.35mmPb Apron was Shielding rate of a I company(fluoroscopy : 96.79%) was the best under the three companies, and shielding rate of an H company(fluoroscopy : 95.81%) was the worst. 0.25mmPb Apron was Shielding rate of X company apron(fluoroscopy : 90.908%) was better than H company apron(fluoroscopy : 88.82%) than two companies. The uniformity measurement results, 0.5mmPb Aprons of X company(fluoroscopy : 0.13) and I company(fluoroscopy : 0.19) was the best under the six companies, and J company apron(fluoroscopy : 0.45) was the worst. 0.35mmPb. Along a manufacturer and lead equivalent performance of apron protection is distinguished certainly. Therefore, a patient, guardian or a person engaged in radiation related industry shall enforce experiment of a lot of ways defined or evaluation so that the maximum reduces radiation exposure. Buy the apron that protective performance is good, It will be performed through experiment and evaluation.

Utility of Wearing Protective Apron for X-ray of Thick Subject (두꺼운 피사체 X선 촬영 시 보호앞치마 착용의 유용성)

  • Choi, Seong-Kwan;Dong, Kyung-Rae
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.167-171
    • /
    • 2017
  • This study examined the effectiveness degree of a protective apron that is taken not to be exposed to the first ray or scattered rays, for X-ray of thick subject like lateral lumbar, and the results are as follows; First, spatial dose by scattered rays is shielded by 3 mmPb protective apron, 86.8% at a distance of 50 cm, 92.7% at 100 cm, and 95.6% at 200 cm, when minimizing the field size, while 89% at a distance of 50 cm, 92.3% at 100 cm, and 95.2% at 200 cm, when maximizing the field size. Second, 1st exposure dose is shielded by 3 mmPb protective apron, 93.7% at a distance of 50 cm, 94.4% at 100 cm, and 93.6% at 200 cm, when minimizing the field size, while 93.7% at a distance of 50 cm, 93.6% at 100 cm, and 94.2% at 200 cm, when maximizing the field size.

Analysis of Lead and Bismuth Absorption Rate by Monte Carlo Simulation (몬테카를로 시뮬레이션에 의한 납과 비스무트 흡수율 분석)

  • Kim, Gap-Jung;Kim, Nak-Sang;Yoo, Se-Jong;Lee, Won-Jeong;Kim, Jeong-Ho;Hong, Seong-Il;Jeon, Min-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.419-425
    • /
    • 2022
  • In the medical field, lead aprons are used to protect the human body from radiation. However, lead is a heavy metal that is harmful to the human body and the environment, so various shield are being developed. In this study, bismuth, which has a similar atomic number to lead, was set as a new material and the absorption rate according to thickness in the same energy region was compared and evaluated through Monte Carlo simulation. The same tendency was confirmed when the thickness of the lead shield was 0.25 mm, the thickness of the bismuth was 0.3 mm, when the lead was 0.50 mm, the bismuth was 0.60 mm, and when the lead was 0.75 mm, the bismuth was 0.90 mm. Therefore, it is reasonable to replace lead with bismuth in the shield material.

Development of the paper bagging machine for grapes (휴대용 포도자동결속기 개발연구)

  • Park, K.H.;Lee, Y.C.;Moon, B.W.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.11 no.1
    • /
    • pp.79-94
    • /
    • 2009
  • The research project was conducted to develop a paper bagging machine for grape. This technology was aimed to highly reduce a labor for paper bagging in grape and bakery. In agriculture labor and farm population has rapidly decreased since 1980 in Korea so there was so limit in labor. In particular there is highly population in women and old age at rural area and thus labor cost is so high. Therefore a labor saving technology in agricultural sector might be needed to be replaced these old age with mechanical and labor saving tool in agriculture. The following was summarized of the research results for development of a paper bagging machine for grape. 1. Development of a new paper bagging machine for grape - This machine was designed by CATIA VI2/AUTO CAD2000 programme. - A paper bagging machine was mechanically binded a paper bag of grape which should be light and small size. This machine would be designed for women and old age with convenience during bagging work at the field site. - This machine was manufactured with total weight of less than 350g. - An overage bagging operation was more than 99% at the actual field process. - A paper bagging machine was designed with cartridge type which would be easily operated between rows and grape branches under field condition. - The type of cartridge pin was designed as a C-ring type with the length of 500mm which was good for bagging both grape and bakery. - In particular this machine was developed to easily operated among vines of the grape trees. 2. Field trials of a paper bagging machine in grape - There was high in grape quality as compared to the untreated control at the application of paper bagging machine. - The efficiency of paper bagging machine was 102% which was alternative tool for the conventional. - The roll pin of paper bagging machine was good with 5.3cm in terms of bagging precision. - There was no in grape quality between the paper bagging machine and the conventional method. - Disease infection and grape break was not in difference both treatments.