• Title/Summary/Keyword: 보조가스

Search Result 184, Processing Time 0.024 seconds

A Study on Electromagnetic Compatibility Performance Evaluation of Power Conditioning System for Residential Fuel Cell (가정용 연료전지 전력변환장치 전자파적합성 성능 평가 연구)

  • Choi, Young-Joo;Nam, Tae-Ho;Lee, Eun-Kyung;Lee, Duk-Gwon;Lee, Jung-Woon;Lee, Seung-Kuk;Moon, Jong-Sam
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.6
    • /
    • pp.23-29
    • /
    • 2017
  • Solar and wind energy among the renewable energy produce irregular power because resource is difficult to control. When connected to grid have unstable. However, when the fuel cell system is connected to grid more stable because regular frequency and output power based on controllable hydrogen energy. To using fuel cell system in the household, it is important that the safety performance of power conditioning system(PCS) and it is important that evaluation method of electromagnetic compatibility(EMC). In this study, we consider that introduce power-frequency magnetic field immunity test before analyzed that compare with the EMC of the international standards and KGS AB 934 PC53. Also, we conduct that actual assessment and study on available the quantitative analysis as using complementary indicator.

Remote Monitoring Panel and Control System for Chemical, Biological and Radiological Facilities (화생방 방호시설을 위한 원격감시 패널 및 제어시스템)

  • Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.464-469
    • /
    • 2019
  • A remote monitoring panel and control system was developed to control various valves and access control chambers, including gas shutoff valves used in CBR(Chemical, Biological and Radiological) facilities. The remote monitoring panel consisted of a main panel installed in the NBC (Nuclear, Biological and Chemical) control room and auxiliary panel installed in the clean room, and the size was divided into pure control and control including CCTV. This system can be monitored and controlled remotely according to the situation where an explosion door and gas barrier door can occur during war and during normal times. This system is divided into normal mode and war mode. In particular, it periodically senses the operation status of various valves, sensors, and filters in the CBR facilities to determine if each apparatus and equipment is in normal operation, and remotely alerts situation workers when repair or replacement is necessary. Damage due to the abnormal operation of each device in the situation can be prevented. This enables control of the blower, supply and exhaust damper, emergency generator, and coolant pump according to the state of shutoff valve and positive pressure valve in the occurrence of NBC, and prevents damage caused by abrupt inflow of conventional weapons and nuclear explosions.

Serum Leakage Control using PP/PDMS Composite Membrane (PP/PDMS 복합막을 이용한 혈청누출 제어)

  • 김기범;이삼철;정순량;정경락
    • Membrane Journal
    • /
    • v.10 no.1
    • /
    • pp.47-53
    • /
    • 2000
  • The artificial lung is a device used to replace the function of the lungs. The major function of the lung is to remove carbon dioxide from the venous blood and replace it with oxygen, or arterialize the blood. And the function of the artificial lung is to provide an adequate amount of oxygenated blood to all the tissues of body during the open heart surgery. Extracorporeal life support(ECLS or ECMO) is standard treatment for severe respiratory failure but poses many contributions to future lung transplantation. Artificial Lung or membrane oxygenators available today, based on microporous polypropylene fibers, are associated with two major problems. They require systemic anticoagulation of the patient and they allow serum leakage across the membrane from the blood side to the gas side during long-term use. We obtained newly fabricated polypropylene(PP)/polydimethylsiloxane(PDMS) membranes which combined PP membrane, a microporous support layer with PDMS, and we had investiaged a technique for minimizing serum lekage of polypropylene(PP) membrane. The gas permeability of each PP/PDMS membrane was almost constant before and after the whole blood test by Lee-White method, while that of PP membrane was significantly reduced. Therefore the PP/PDMS membrane could be prevented serum leakage of PP membrane. In addition, the gas permeability of $CO_2$ in PP/PDMS membrane was 11.5 times higher as compared with that of $O_2$.

  • PDF

Prioritization of National R&D Investment Using Estimation Results by CGE Model (CGE모형 추정결과를 이용한 국가 R&D 투자 우선순위 설정)

  • Lim, Byung-In;Ahn, Seung-Ku
    • Journal of Technology Innovation
    • /
    • v.19 no.3
    • /
    • pp.57-83
    • /
    • 2011
  • We suggested industry-specific priorities of R&D investment with R&D investment elasticity to GDP calculated from the ripple effect of 28 large-sized industry R&D investment, using a Computable General Equilibrium(CGE) Model. Priority orders apply to only 12 industries, because 16 industries with less than 1% of total investment have been excluded. First, R&D investment elasticity to GDP says that priorities are ordered as Basic metal products, Chemicals, drugs and medicines, Food, beverages and tobacco products, Electronic and electrical equipment, Transportation equipment, Precision instruments, Electrictity, gas, steam and water supply, General machinery and equipment, Communications and broadcasting, Construction, Other services, and Real estate and business services. These priorities show the status quo of Korean industry structures well. The GDP growth rate to 2030 year reference equilibrium, which is an auxiliary index, says a similar priority to results from R&D investment elasticity to GDP. In the end, two criteria of priority order can be functioned as a good index for National Science and Technology Commission deciding what industry to invest and what budget to allocate.

  • PDF

Disposal and Waste-to-Fuel of Infected Poultry with Avian Influenza(AI) Using Thermal Hydrolysis Reaction (열가수분해 반응을 이용한 조류인플루엔자(AI) 감염 가금류의 사체처리 및 연료화)

  • Song, Chul-Woo;Kim, Nam-Chan;Jeong, Guk;Ryu, Jae-Keun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.4
    • /
    • pp.49-57
    • /
    • 2016
  • In this study, a thermal hydrolysis technology was used to treat the poultry carcasses that were killed due to Avian Influenza (AI) occurrence, as well as to determine the possibility of fueling for the resultant products. Experimental results showed that the poultry carcasses were liquefied except for sand, and showed the optimum efficiency at $190^{\circ}C$ and operating time of 60 minutes. It has been shown that liquid products obtained after thermal hydrolysis has good conditions for fuel conversion since it had high carbon contents and calorific value, as well as low ash content. In addition, it was possible to operate the thermal hydrolysis facility by using only the waste heat generated in the combustion without injecting the auxiliary fuel, and the exhaust gas generated in the combustion has a small influence on the atmosphere.

Improving Fuel Efficiency of a Hybrid Excavator (하이브리드 굴삭기 연비 개선 연구)

  • Cho, Sungwoo;Yoo, Seungjin;Park, Cheol-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.2
    • /
    • pp.211-217
    • /
    • 2015
  • Emission gas regulations and constantly increasing fuel costs call for the worldwide use of environmentally friendly and energy-efficient machines in industry. To meet these requirements, a hybrid excavator prototype has been developed that incorporates an electric swing motor, engine assist motor, and ultra-capacitor module into a conventional hydraulic excavator of the 22-ton class. This paper mainly describes a few techniques to optimize its energy efficiency. These include 1) controlling the engine speed in proportion to the load torque, 2) controlling the pump displacement when driving the electric swing system, 3) managing the ultra-capacitor voltage to minimize the electrical energy loss, and 4) reducing the cooling fan speed to improve the energy efficiency of the system.

Partial premixed combustion modeling of diffusion flame burner for SiO2 deposition as optical fiber cladding (광섬유 클래딩용 SiO2 증착을 위한 확산 화염 버너의 부분 예혼합 연소 모델링)

  • Park, Hyung-Bin;Han, Yoonsoo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.29 no.6
    • /
    • pp.365-371
    • /
    • 2019
  • In this study, the flame temperature distribution of the diffusion flame burner for SiO2 deposition was analyzed by the computational fluid analysis. This corresponds to the previous step for simulating the SiO2 preform deposition process for manufacturing optical fibers using environmentally friendly raw materials. In order to model premixed combustion, heat flow, convection, and chemical reactions were considered, and Reynolds-averaged Navier-Stokes equations and k-ω models were used. As a result, the temperature distribution of the flame showed a tendency to increase the distance from the nozzle surface to the maximum temperature when the flow rate of the auxiliary oxygen increased. In addition, it was confirmed that the temperature distribution due to incomplete combustion was large in the combustion reaction with a large equivalence ratio of the mixed gas.

Lean Combustion Characteristics with Hydrogen Addition in a LPG Fuelled Spark Ignition Engine (LPG엔진에서 수소연료 보조분사에 의한 희박연소특성 연구)

  • Oh, Seung-Mook;Kim, Chang-Up;Kang, Kern-Yong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.2
    • /
    • pp.114-120
    • /
    • 2006
  • The basic effects of hydrogen addition for engine performance and emission were investigated in single cylinder research engine. Seven commercial injectors were tested to choose a suitable injector for hydrogen injection prior to its engine implementation. The hydrogen fuel leakage and flow rate were evaluated for each injector and KN3-1(Keihin, CO.) showed the best performance for hydrogen fuel. At the higher excess air ratio(${\lambda}=1.7$, 2.0), the better combustion stability was found with hydrogen addition even though its effect was small at lower excess air ratio (${\lambda}=1.0$, 1.3). Stable operation of the engine was even guaranteed at ${\lambda}=2.0$, if the amount of hydrogen gas was near 15% of total energy. In the lean region, ${\lambda}>1.3$, thermal efficiency was improved slightly while it was not clearly observed at ${\lambda}=1.0$, 1.3. It is considered that, in some cases, high temperature environment due to hydrogen combustion caused further heat loss to surroundings. Except for ${\lambda}=1.0$, with larger amount of hydrogen addition, CO was reduced drastically but it was emitted more at the leaner region. Nitric oxides(NOx) was increased a little more with hydrogen addition at ${\lambda}=1.0$, 1.3. However, at ${\lambda}>1.3$ its relative amount of emission was low. In addition, the amount of NOx was continuously decreased with hydrogen addition, but, at ${\lambda}=2.0$ the amount of NOx was lowered to 1/100 of that of ${\lambda}=1.0$. THC emission was significantly increased as air/fuel ratio was raised to leaner region due to misfire and partial burn.

Study of the Flow Characteristics of Supersonic Coaxial Jets (초음속 동축제트의 유동특성에 관한 연구)

  • Lee, Gwon-Hui;Gu, Byeong-Su;Kim, Hui-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1702-1710
    • /
    • 2001
  • Supersonic coaxial jets are investigated numerically by using the axisymmetric, Wavier-Stokes equations which are solved using a fully implicit finite volume method. Three different kinds of coaxial nozzles are employed to understand the flow physics involved in the supersonic coaxial jets. Two convergent-divergent supersonic nozzles are designed to have the same Mach number 2.0, and used to compare the coaxial jet flows with those discharging from one constant-area nozzle. The impingement angle of the annular jets are varied. The primary pressure ratio is changed in the range from 2.0 to 10.0 and the assistant jet ratio from 1.0 to 3.0. The results obtained show that the fluctuations of the total pressure and Mach number along the jet axis are much higher in the constant-area nozzle than those in the convergent-divergent nozzles, and the constant-area nozzle lead to higher total pressure losses, compared with the convergent-divergent nozzles. The assistant jets from the annular nozzle affect the coaxial jet flows within the distance less than about ten times the nozzle throat diameter, but beyond it the coaxial jet is conical with self-similar velocity profiles. Increasing both the primary jet pressure ratio and the assistant jet pressure ratio produces a longer coaxial jet core.

Exposure to Styrene in the Lamination Processes with Fiberglass-Reinforced Plastics: Health Diagnosis Case Report (유리섬유강화 플라스틱을 이용한 적층공정 근로자들의 스티렌 노출 평가: 보건진단 사례)

  • Choi, Sangjun;Jeong, Yeonhee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.2
    • /
    • pp.126-133
    • /
    • 2015
  • 연구목적: 이 연구는 노동부의 보건진단 명령에 의해 유리섬유 강화플라스틱(FRP)을 이용한 이중벽 탱크 제조 사업장의 적층 공정 근로자들을 대상으로 스티렌 노출 특성을 평가하기 위해 수행되었다. 연구방법: 스티렌의 주요발생원 파악을 위해 불포화 폴리에스테르 수지(UPR), 경화제, 조색제, 세척액 등의 원료 내 스티렌 함유량을 가스크로마토그래피 질량분석기(GC-MS)를 이용하여 분석하였다. FRP 적층 공정에 근무하는 작업자들을 대상으로 NIOSH 1501 공정시험법에 의해 공기 중 스티렌 노출 농도에 대한 개인노출 평가를 실시하였고, 생물학적 노출 지표로 뇨 중 만델릭산을 채취한 후 고성능액체크로마토그래피(HPLC)로 분석하였다. 또한 각 직무 특성과 단위작업 중심으로 스티렌에 대한 단시간 노출평가를 수행하였다. 연구결과: 스티렌의 함유량이 가장 많은 주요 원료는 중량비율로37%의 스티렌이 함유된 UPR이었다. 적층 공정의 FRP분무 작업자와 보조 작업자들 모두 스티렌의 8시간 가중평균 노출기준(20 ppm)을 초과하였다. 단시간 노출평가 결과 FRP분무 작업자의 경우 45.9 ppm에서 86.1 ppm 수준으로 FRP를 사용하지 않는 작업보다 통계적으로 유의하게 높은 수준이었다(P<0.01). 가장 높은 수준의 스티렌에 노출되는 단위작업은 FRP를 이용하여 1차 코팅 하는 작업으로 특별한 관리가 필요하였다. 결론: 보건진단을 위해 실시한 이중벽 탱크 제조 사업장의FRP 적층 공정 작업자의 스티렌 노출수준은 노출기준을 초과할 정도로 높은 수준이었다. 그러나 탱크를 천장에 매달고 돌리면서 적층작업을 수행하기 때문에 적절한 국소환기 시스템을 구축하는데 어려움이 있다. 따라서 적절한 방독마스크 착용으로 스티렌 노출 예방이 필요하였다.