• 제목/요약/키워드: 보정 기구

검색결과 122건 처리시간 0.027초

마이크로 병렬기구 플랫폼의 기구학적 보정 (Kinematic calibration for parallel micro machine platform)

  • 강득수;김종원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.969-972
    • /
    • 2004
  • This paper describes the mechanism of parallel micro machine platform and its feedback control system for acquiring high accuracy. The parallel micro machine platform that has developed has 5x5x5 work-space and sub-micron accuracy. For the high accuracy, the feedback control system is important but errors in machining and assembling are inevitable. Kinematic calibration is important for this reason. In this paper, various error components are introduced and the effects of error component are analyzed.

  • PDF

불균일 휘도 장원의 UGR 보정에 관한 연구 (The study of a revision UGR for non-uniform luminance source)

  • 정승균;조용익;오석식;김훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.137-140
    • /
    • 2008
  • 실내조명으로서의 LED는 휘도의 분포특성이 기존의 조명기구와는 판이하게 다르며, 이에 따라 불쾌감을 느끼는 정도에서도 변화가 일어날 수 있다. 본 연구에서는 현재 가장 일반적으로 사용되어지는 글레어 평가지수인 UGR을 간단히 보정하여 LED 조명기구에 대한 값으로 사용할 수 있도록 주관평가 실험을 통해 보정식을 산출해내고 LED 조명기구별 증가계수 k를 구하였다.

  • PDF

선형 반복법에 의한 이동로봇의 동시 보정 (Simultaneous Mobile Robot Calibration using Iterative Linear Method)

  • 김영용;정문호
    • 한국전자통신학회논문지
    • /
    • 제10권7호
    • /
    • pp.793-800
    • /
    • 2015
  • 이동 로봇 Pan-Tilt 기구부에 장착된 스테레오 카메라의 Head-Eye 보정 및 Wheel 보정을 동시에 수행하는 방법을 제안한다. 카메라가 이동로봇의 고정형 기구부에 장착되어있는 경우를 고려한 기존의 방법들은 최근 일반적인 이러한 시스템에 적용될 수 없다. 이러한 문제점을 해결하기 위하여 본 논문에서는 기존 방법을 바탕으로 한 선형 반복적인 방법을 고안하였다. 이것은 동시보정을 통한 효율성뿐만 아니라 정확도 면에서도 만족할만한 결과를 얻었다. 그리고 비선형 최적화 기법을 통해 보다 높은 정확도의 보정을 구현했다.

퍼지논리 제어에 의한 CNC 서보기구의 마찰보정에 관한 연구 (A Study on the Friction Compensation in CNC Servomechanisms by Fuzzy Logic Control)

  • 지성철
    • 한국정밀공학회지
    • /
    • 제15권9호
    • /
    • pp.56-67
    • /
    • 1998
  • This paper introduces a friction compensation fuzzy logic controller, which utilizes a rule-based approach. The paper explains the algorithm of the proposed controller and compares it with a conventional PID controller in simulations and experiments. For the experiments, the two control algorithms were implemented on a 3-axis milling machine in contour milling. These simulation and experimental analyses show that the proposed fuzzy logic controller has superior performance over conventional PID controllers In terms of part contour accuracy.

  • PDF

컴퓨터모델의 확률적 보정 및 탄소성 압착문제의 신뢰도분석 응용 (Probabilistic Calibration of Computer Model and Application to Reliability Analysis of Elasto-Plastic Insertion Problem)

  • 유민영;최주호
    • 대한기계학회논문집A
    • /
    • 제37권9호
    • /
    • pp.1133-1140
    • /
    • 2013
  • 컴퓨터 해석모델은 물리현상을 바탕으로 단순화된 모델을 구축하고 해를 구하는 유용한 도구이나, 많은 경우 단순화 가정 또는 입력변수 정보의 미비나 불확실성으로 인해 실제와 차이가 발생한다. 본 연구에서는 이러한 문제에 대해 베이지안 확률이론을 이용하여 실측데이터를 통해 해석모델을 보정하는 방법을 소개하고 이를 파이로 작동기구의 탄소성 압착 문제에 적용한다. 파이로 작동기구는 고에너지의 재료를 원격으로 폭발시켜 작동하는 장치로 그 작동의 신속한 계산을 위해서 단순한 수학모델을 구축하고 실험데이터를 토대로 미지의 입력변수를 확률적으로 보정하였다. 이 때, 확률적 추정을 위해서는 현대적 계산통계기법의 하나인 Markov Chain Monte Carlo 기법을 이용하였으며, 최종적으로 그 결과를 압착거동해석에 활용하여 작동기구의 신뢰도를 평가하였다.

병렬기구형 공작기졔의 기구학적 보정에 관한 연구 (Study on Kinematic Calibration of a Parallel-typed Machining Center Tool)

  • 이민기;김태성;박근우
    • 대한기계학회논문집A
    • /
    • 제26권11호
    • /
    • pp.2237-2244
    • /
    • 2002
  • This research develops a low-cost and high accuracy kinematic calibration method based on the following principles: 1) the platform locations are accurately measured by a constrained movement to inspect a calibration target; 2) the constrained movement is chosen to guarantee the parameter observability; 3) the mechanical fixture to constrain the movement and the sensor to check the constrained movement are implemented by low-cost and high-accuracy devices; 4) the calibration is easily done at an industrial environment. The kinematic parameters calibrated with respect to a single plane aren't influenced due to the misalignment of the plane. A parameter observability is successfully obtained even through one planar constraint, which guarantees that all kinematic parameters are estimated by minimizing the cost function.

공간오차 측정을 통한 6자유도 병렬기구의 보정 (Calibration of 6-DOF Parallel Mechanism Through the Measurement of Volumetric Error)

  • 오용택;아궁 샴수딘 사라기;김정현;고태조
    • 한국기계가공학회지
    • /
    • 제11권3호
    • /
    • pp.48-54
    • /
    • 2012
  • This paper introduces the kinematic calibration method to improve the positioning accuracy of a parallel mechanism. Since all the actuators in the parallel mechanism are controlled simultaneously toward the target position, the volumetric errors originated from each motion element are too complicated. Therefore, the exact evaluation of the error sources of each motion element and its calibration is very important in terms of volumetric errors. In the calibration processes, the measurement of the errors between commands and trajectories is necessary in advance. To do this, a digitizer was used for the data acquisition in 3 dimensional space rather than arbitrary planar error data. After that, the optimization process that was used for reducing the motion errors were followed. Consequently, Levenberg-Marquart algorithm as well as the error data acquisition method turned out effective for the purpose of the calibration of the parallel mechanism.

병렬기구형 틸팅 테이블의 보정에 관한 연구 (Study on Calibration for Parallel-Typed Tilting Table)

  • 김태성;정진욱;김용희;박근우;이민기
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1512-1517
    • /
    • 2003
  • This paper presents the calibration for the parallel typed tilting table. The calibration system needs only simple sensing device which is a digital indicator to measure the orientation of a table. The calibration algorithm is developed by a measurement operator. It eliminates the concern about the poor parameter observability due to a large number of parameters of parallel-mechanism. This paper uses the QR-decomposition to find the optimal calibration configurations maximizing the linear independence of rows of a observation matrix. The number of identifiable parameters is examined by the rank of the observation matrix, which represents the parameter observability. The method is applied to a Parallel-typed Tilting Table and all the necessary kinematic parameters are identifiable.

  • PDF