• Title/Summary/Keyword: 보실험

Search Result 15,336, Processing Time 0.045 seconds

Heat Conduction Analysis and Fire Resistance Capacity Evaluation of Reinforced Concrete Beams Strengthened by FRP (FRP로 보강된 철근콘크리트보의 열전도해석 및 내화성능 평가)

  • Lim, Jong-Wook;Park, Jong-Tae;Kim, Jung-Woo;Seo, Soo-Yeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.1-8
    • /
    • 2018
  • The object of this paper is to find the characteristics of fire proof materials through an analytical method and to suggest a proper approach for fire-proof design of reinforced concrete beam strengthened with fiber reinforced polymer (FRP). Heating tests for fire-proof materials were conducted and the thermal conductivities and specific heats of them were simulated through finite element analyses. In addition, a finite element analysis on the beam specimen strengthened with FRP under high temperature, which was conducted by previous researchers, was performed and the analytical result was compared with test result. And then the compatibility of the analytical approach was evaluated. Finally, the heat resistance characteristic of RC beam strengthened with FRP was analyzed by the proposed analytical method and the strength decrease of the beam due to the high temperature was evaluated. From the comparison with analytical and test result, it was found that the heat transfer from outside to inside through the fire-proof materials can be suitably simulated by using the proposed analytical approach.

Effect of Flexural Performance on U-Shaped Precast Concrete Beams with Noncontact Lapped Splice (비접촉 겹침 이음된 프리캐스트 U형 보의 휨성능에 미치는 효과)

  • Ha, Sang-Su;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.6
    • /
    • pp.119-128
    • /
    • 2008
  • In this study, new moment-resisting precast concrete beam-column joint is proposed for moderate seismic regions. It has the connection reinforcing bars, penetrated the joint and lap-spliced with the bottom bars of precast U-shaped PC beam. To evaluate the performance for noncontact lapped splice, experimental and analytical works were conducted. Major variables for tests are the length of lap, the diameter of connection reinforcing bars, and the distance between lapped bars. Analytic research was performed nonlinear finite element method. Analytic research focused on crack pattern, load-deflection curve, comparison of internal force, evaluation of ductility strains of reinforcement bar. Results of experimental and analytical works show that the these variables has much influence on flexural strength and ductility, and joint behavior.

Flexural Behavior of Reinforced Concrete Beams Exposed to Freeze-Thawing Environments (동결융해 환경에 노출된 철근콘크리트 보의 휨 거동특성)

  • Jang, Gwang-Soo;Yun, Hyun-Do;Kim, Sun-Woo;Park, Wan-Shin;Choi, Ki-Bong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.6 s.58
    • /
    • pp.126-134
    • /
    • 2009
  • Generally, reinforced concrete structures exposed to the outside temperature are affected by freezing and thawing process during winter and early spring. These freeze-thawing process can lead to the reduction in durability of concrete as cracking or surface spalling. This paper is to study the flexural behavior of RC beams exposed to freeze-thawing environments. To compare the difference in flexural behavior of RC Beams, limited tests were conducted under different types of Longitudinal steel ratio and freeze-thawing cycles. For this purpose, fourteen small-scale RC beams ($100mm{\times} 100mm {\times}600mm$) were strengthened in monotonic and cyclic loadings, subjected to up to 150, 300 cycles freeze-thawing from $-18{\sim}4^{\circ}C$. It is thought that experimental results will be used as basic data to evaluate flexural behavior of RC beams exposed to freeze-thawing.

Study on the Shear Strengthening of Concrete Beams with Wire Rope Clamped by Bolts (볼트 체결된 와이어 로프를 이용한 RC 보의 전단보강에 대한 연구)

  • Kim, Sun-Young;Song, Jin-Gyu;Lee, Young-Uk;Byun, Hang-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.2 s.92
    • /
    • pp.283-290
    • /
    • 2006
  • The paper describes m experimental study on the shear strengthening of concrete beams with exposed wire rope. The strengthening method is using the mechanical bolting of wire rope tensioned on the exterior of beam section. There are two shear strengthening types. The first is closed type wrapped beam section with wire rope like as closed stirrup. The second is U type tensioned at the anchor located in the side of beam section. The main parameters of specimens are strengthening spacings of wire rope with 150, 200, and 250mm for the closed and U type respectively. The shear span ratio of specimens applied by 3-point loading is 4. The results showed that the ultimate shear strength and ductility of strengthened beams increased significantly compared with non-strengthened beams. Especially, the strengthening effect of closed type was very preferable to U type. Therefore, the shear strengthening method with wire rope is very reasonable in view of repair and rehabilitation of beams.

Cracking Behavior and Flexural Performance of RC Beam with Strain Hardening Cement Composite and High-Strength Reinforcing Bar (고강도 철근과 변형경화형 시멘트복합체를 사용한 보의 균열거동 및 휨 성능)

  • Jang, Seok-Joon;Kang, Su-Won;Yun, Hyun-Do
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.1
    • /
    • pp.37-44
    • /
    • 2015
  • This paper describes the effect of strain hardening cement composite (SHCC) material on structure performance of reinforced concrete (RC) beams with high-strength reinforcing bar. Also, this paper explores the structure application of SHCC in order to mitigation cracking damage and improve the ductility of flexural RC members. The prediction model for flexural strength of doubly reinforced SHCC beams are investigated in this study. To achieve the these objectives, a total of 6 rectangular beam specimens were tested under four point monotonic loading condition. The main parameters included the types of cement composite and reinforcing bar. Test results indicated that reinforced beam specimens with SHCC material were improved the structure performances and damage characteristics. Specifically, replacement of conventional high-strength concrete with SHCC materials has the potential of high-strength steel bar as flexural reinforcement on RC members. It is remarkable that suggested method of reinforced SHCC beams with high-strength reinforcing bar could be used usefully to the structure design.

An Experimental Study on the Flexural Behavior of RC Beams Strengthened with High-Strength Bars(1) (고장력 인장봉으로 보강된 RC보의 휨거동에 관한 실험적 연구(1))

  • Shin, Kyung-Jae;Kwak, Myong-Keun;Heo, Byung-Wook;Na, Jung-Min;Oh, Young-Suk
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.4 s.94
    • /
    • pp.527-534
    • /
    • 2006
  • This paper outlines a new strengthening technique for concrete beams using externally unbended high-strength bars. The advantages of proposed method lie in speed and simplicity of construction compared to the alternative strengthening method. Externally unbended reinforcement retains many of the advantages over external unbended prestressed tendons. It eliminates time consuming stressing operations. Clearance requirements around anchorages are reduced as access is not required for prestressing jacks. Test results of eight specimens on reinforced concrete beams using different reinforcement materials such as carbon fiber sheet, steel plate and high-tension bar are reported. The beam strengthened by carbon fiber sheet showed a brittle failure mode due to the separation of fiber. As a result of draped profile of external bar, the maximum strength of the beam were increased by up to 212 percent and the deflections were reduced by up to 65 percent. Test results show that the beams reinforced with high-tension bar are superior to reference specimens, especially for the strength and deformation capacity.

The Implementation of Cyber Experiments Improving the Interactions between Experimenters and Experimental Environment (실험자와 실험 환경간의 상호작용을 개선한 사이버 실험 구현)

  • 정춘홍;남영호
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2001.10b
    • /
    • pp.580-582
    • /
    • 2001
  • 웹 기반의 사이버 실험이 탐구적 실험이 되기 위해서는 실제 실험에서 나타나는 상호작용을 반영할 수 있어야 한다. 그 결과 사이버 실험은 탐구적 실험이 될 수 있다. 기존 대부분의 사이버 실험들은 완성되어 있는 실험 장치를 제공하고, 버튼의 클릭으로 실험 진행과 실험 결과를 보여주는 단순한 애니메이션 유형으로, 실제 실험에서 나타나는 실험자와 실험 환경간의 상호작용을 반영하지 못하고 있다. 본 논문에서는 웹 기반 사이버 실험에서 실험 기구의 설치에서부터 실험 과정 및 실험 종료에 이르기까지 학습자와 실험 환경간에 상호작용이 이루어질 수 있는 사이버 실험을 설계 및 구현한다. 또한 구현한 사이버 실험을 교육 현장에 적용하여 학습 효과에 미치는 영향을 평가한다.

  • PDF

Flexural Behavior of Fiber Reinforced Concrete Beams with Hybrid Double-layer Reinforcing Bars (이중 보강근을 가지는 FRC 보의 휨성능)

  • Kim, Seongeun;Kim, Seunghun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.199-207
    • /
    • 2018
  • Experimental programs were performed to evaluate the flexural performance of fiber reinforced concrete(FRC) beams using a hybrid double-layer arrangement of steel bars and fiber reinforced polymer(FRP) bars or using FRP bars only. A total of seven beam specimens were produced with type of tensile reinforcing bar(CFRP bar, GFRP bar, steel bar) and the poly vinyl alcohol(PVA) fiber mixing ratio(0.5%, 0%) as variable. An analysis method for predicting the flexural behaviors of FRC beams with hybrid arrangement of heterogeneous reinforcing bars through finite element analysis was proposed and verified. In case of the specimens with the double-layer reinforcing bars, the test results showed that the first cracking load of specimen with a double-layer arrangement of steel bars was greater by 26-34% than specimens with a hybrid double-layer arrangement of steel and FRP bars. In maximum flexural strengths, the specimen that used CFRP bars as bottom tensile reinforcing bar showed the greatest strength among the specimens with the double-layer reinforcing bars. When the maximum moment value obtained through experiments was compared with that obtained through analysis, the ratio was 1.2 on average, the standard deviation was 0.085, and the maximum error rate was 22% or less. Based on these results, the finite element analysis model proposed in this study can effectively simulate the actual behavior of the beams with hybrid double-layer reinforcing bars.

Analysis of changes in air consumption according to water depth in underwater search (수중수색 시 수심에 따른 공기소모량의 변화 분석)

  • Jeon, Jai-In;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.1
    • /
    • pp.433-439
    • /
    • 2020
  • This study compared and analyzed the change of air consumption according to water depth with human characteristics and theoretical values. The experimental results are as follows. First, subjects A and B showed similar rise rates depending on the water depth. Second, subject C had a significantly higher rate of increase in air consumption at 25m underwater because the body responded sensitively to deep water pressure, which increased air consumption because breathing was faster than other participants. Third, the subjects D and E showed significantly lower overall air consumption. D and E were 37 and 35 years of age, respectively, the youngest, strongest and most experienced in deep sea diving at the time of military service. Fourth, the average air consumption per minute of the test subjects increased from 5m in water to 1.45 times, 10m in water to 1.85 times, and 20m in water to 2.8 times. This seems to be a result of different experiences, physical fitness, the degree of adaptation of the body to underwater, and different breathing techniques. Lastly, the difference between the experimental average value and the theoretical value appears to be the result of using more or less air than the theoretical value depending on the experiences and physical strength of each of the 5 rescuers, the degree of adaptation of the body underwater, and the method of underwater breathing.

지반하중조건에 따른 숏크리트 거동의 수치해석적 검증

  • Yu, Gwang-Ho;Jeong, Ji-Seong;Park, Yeon-Jun
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2007.10a
    • /
    • pp.365-374
    • /
    • 2007
  • 본 논문은 터널의 지반-지보재 상호 거동을 규명하기 위한 연구로서 주지보재인 숫크리트의 균열, 파괴하중 및 변형거동을 실물크기의 갱도모형실험을 통해 확인하고 3차원 수치 해석을 실시하여 각각의 결과를 비교 검증하였다. 갱도모형 실험은 실제 터널과 유사한 크기의 터널을 제작하여 11개 실린더에서 측압조건에 따라 하중을 가하여 실험을 수행하였다. 3차원 수치해석 모델링은 갱도모형실험과 가능하면 같은 조건으로 해석하기 위하여 모형실험으로부터 로드셀 및 LVDT를 통해 얻은 하중-변위곡선이 수치해석 시에도 재현되도록 하여 수행되었다.

  • PDF