• Title/Summary/Keyword: 보상계획

Search Result 154, Processing Time 0.041 seconds

A study on system improvement to utilization of underground space for the right complementary - Focused on land of exceeding the depth limit - (지하공간 활용의 권리보완을 위한 제도적 개선에 관한 연구 - 한계심도 초과 토지를 중심으로 -)

  • Seo, Yong-Su;Choi, Seung-Young
    • Journal of Cadastre & Land InformatiX
    • /
    • v.44 no.1
    • /
    • pp.97-111
    • /
    • 2014
  • As urbanization and industrialization develops, the necessity of utilizing scarce land in three dimensions is raising. The issue of utilizing underground space is being actively discussed particularly when Geyeonggi-do announced GTX(Great Train Express) construction plan which aims to relieve traffic congestion in metropolitan areas. The current regulation on compensation of underground space is based on "Regulations on compensation standard complied by using underground space for construction of urban railway" but it is difficult for covering the whole rights to protect a three-dimensional right. In this context, the study is to propose the improvement plans of land right's problem and compensation issues to utilization of underground space for the right complementary. To do this, the study reviews the use situation of the classification surface right and using adjudication which defines the effect scope of underground space extending land ownership. As well as it analyzes issues about compensation standard for utilizing of underground space.

The Installation and Site Test of 154kV STATCOM (154kV STATCOM(정지형 무효전력 보상장치) 국산화 최초설치 및 현장시험)

  • Bahng, Seon-Woong;Min, Byeong-Wook;Shin, Myoung-Sik;Yoo, Hyun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.170-171
    • /
    • 2011
  • 현재 제주지역 전력계통은 원형 모양의 다중계통으로 구성되어 있어 송전선로 고장 발생시 단일계통으로 운전됨에 따라 말단 측에 전압문제가 발생할 우려가 있을 뿐만 아니라, 대규모 풍력발전단지 조성 및 #2 HVDC 제주연계로 제주지역내 무효전력 수급 불균형 상황이 발생할 것으로 예상된다. 이에 따라 제주지역 전력계통 전압안정도 개선을 위하여 순동 무효전력 보상장치를 154kV 한라, 신제주변전소에 설치하기로 계획하였으며 154kV급 STATCOM(정지형 무효전력 보상장치)으로 결정되었다. 이번에 제주에 적용된 STATCOM은 미금변전소에 설치된 345kV급 STATCOM에 이어 국내기술로 개발된 설비로 154kV급으로는 처음 국내에 설치되었다. 제주지역 특성을 반영하여 변압기, 인버터 등 STATCOM 구성 주요기기에 대한 정격을 결정, 기술규격을 확정한 후 구매를 추진하였고 2011년 1월부터 설치를 착수하여 2011년 5월말 시운전 목표로 추진하고 있다. 본 논문에서는 국내에 최초로 적용되는 154kV급 STATCOM의 현장설치 주요과정에 대한 소개와 현장시험 주요항목 및 유의사항에 대해 기술하고 있다.

  • PDF

Summary of Static Reactive Power Compensator and Influence analysis of Power System Stability (무효전력보상장치 설비 개요 및 전력계통 안정화 영향분석)

  • Kim, Sung-Arm;Han, Byung-jun;Jang, Young-Hoon;Choi, Jin-San
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.343-344
    • /
    • 2015
  • 전력산업은 친환경 신재생 에너지 자원의 증대, 국가간 에너지 교류 등 고성능 대용량 전력전자 응용분야 기기의 필요성이 지속적으로 확대되고 있다. 신규 AC 송전선로 건설이 민원 등의 사유로 건설에 장시간 소요되고, 건설단가의 지속적 증가 및 전력전자 설비의 가격하락(HVDC, FACTS 등 특수설비의 국산화 추진) 등으로 AC 송전선로 신규건설 보다는 송전선로 조류제어로 전력계통 유연성 향상이 필요하게 되었으며, 향후 융통전력의 한계, 전력수요 포화 및 Smart Grid 시대를 대비하여 기존 송전선로의 이용을 극대화하는 방향으로 계통계획의 방향 전환이 더욱 급속도로 진행될 전망이다. 본 논문에서는 최첨단 무효전력보상장치 소개와 계통안정화를 위한 전력계통 영향분석을 통해 직 병렬 FACTS의 필요성을 소개하고자 한다.

  • PDF

A Study on the River Zone Determination Method by River Type Based on 3D DSM Data (3차원 DSM 자료 기반 하천유형별 정밀 하천구역 결정기법 개발)

  • Lim, Dong Hwa;Lee, Choon Ho;Lee, Tae Geun;Sim, Gyoo Seong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.472-472
    • /
    • 2021
  • 우리나라는 하천법 제10조, 소하천정비법 제3조에 하천기본계획 수립 또는 하천의 지정 및 변경고시 시 하천구역을 결정하도록 정의되어 있다. 하천구역 설정 시 일반적으로 하천의 제방이 위치하는 부지 및 제방하심측 토지경계를 하천구역으로 지정하고 있으나, 제방계획이 없거나 무제부 구간으로 활용되고 있는 구간의 경우 하천법 제10조 3항에서 5항까지 3가지 항목을 기준으로 계획하폭에 해당하는 토지, 댐·하구둑·홍수조절지·저류지의 계획홍수위 아래에 해당하는 토지경계, 철도·도로 등 제방의 역할을 하는 선형공작물 하심측 토지경계로 구분하고 있다. 하천구역의 경계설정의 경우 불연속적인 특징을 갖는 하천의 횡단측점 자료의 특성상 정확한 평면상의 경계를 파악하기 어렵고, 철도·도로 등 선형공작물 경계를 하천구역으로 설정 시 편입용지의 보상이 상이하고 모호한 기준으로 인해 다량의 민원이 발생하는 실정이다. 본 연구에서는 부산시에 위치한 지방하천 대천천을 대상지로 설정하였으며, 계획홍수위를 기반으로 홍수범람예상도를 작성하여 정밀계획홍수위선을 산출하고 이를 지형자료와 중첩하여 계획홍수위 경계를 추출하였다. 또한 무제부 구간 내 드론촬영을 실시하여 대상지 드론영상 기반 3차원 정밀 지형자료를 구축하고 이를 앞서 산정한 계획홍수위 경계자료와 중첩하여 정밀 하천구역을 설정하였다. 대상지 정밀 하천구역 산정 결과를 기반으로 도심지내 하천과 도시외곽 하천으로 구분하고 다시 도심지내하천은 암거(복개)구간과 개거구간, 도시외곽하천은 유제부와 무제부 구간으로 구분하여 정밀 하천구역 결정기준을 수립하였다. 본 연구를 통해 대천천유역을 대상으로 실시한 무제부 구간 하천구역 결정과정을 기반으로 하천유형별 3차원 하천구역 산정기법을 정립하였다. 향후 해당기법을 실무에 적용하여 하천구역 산정 시 모호한 하천경계부분 또는 토지소유주와 담당부처 간 하천구역 논의 시 기반자료로 활용될 수 있을 것으로 사료되며, 기본계획 수립 시 해당 기법 적용을 통해 보다 정확한 하천구역 경계 수립이 될 수 있을 것으로 기대된다.

  • PDF

통신시설투자 적정규모 산정에 관한 연구

  • 남규택;이보상;홍경권
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1992.04b
    • /
    • pp.63-72
    • /
    • 1992
  • 본 연구의 목적은 교환기 및 가입자 선로에 대한 투자계획의 수립 즉 적정수준의 공급주기와 공급량을 산정하는 방안을 모색해 보는 것이다. 이와 같은 연구를 수행하기 위하여 우선 한국통신의 공급계획수립업무에 대한 현황파악과 함께 한국통신의 공급계획수립에 적용할 수 있는 이론적 모형을 다각도로 검토해 보았다. 그 결과 재고모형이 가장 적합하다고 판단되어 재고모형의 여러 대안을 현행 공급계획수립방법과 비교하여 공급주기와 총비용을 비교분석하였다. 본 연구에서는 Economic Order Quantity(EOQ)모형, Dynamic Lot Size(DLS)모형, 그리고 Simulation이 분석의 도구로 사용되었으며, Simulation은 두가지 방법을 적용하였다. 첫번째 방법은 개별 전화국을 대상으로 simulation을 실시하여 최소의 비용을 보이는 공급주기를 각 전화국별로 산정하는 것이며, 두번째 방법은 모든 전화국에 동일한 공급주기를 적용하여 개별 전화국에서 발생하는 비용의 총합계가 최소화되는 공급주기를 산정하는 것이다. 각 대안별로 공급주기와 총비용을 산정해 본 결과 교환기의 경우는 총비용면에서 현행방법과 본 연구에서 제안한 대안들간에 커다란 차이는 없었으나, 모든 전화국에 동일한 공급주기를 일률적으로 적용시키는 것보다 각 전화국의 수요증가형태에 맞는 공급주기를 별도로 산정하여 적용시키는 것이 보다 경제적이었다. 한편, 가입자선로의 경우는 본 연구에서 제시한 대안들이 현행방법에 비해 연간 수백억원에 이르는 투자지출을 절감 할 수 있음을 보였다.

  • PDF

Methodological Issues in Socio-Economic Assessment of the Hydrogen Economy Development (수소경제로 이행을 위한 사회경제적 영향평가 방법론)

  • Kim, Ho-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.586-591
    • /
    • 2005
  • 우리나라는 에너지의 안정적 공급과 에너지이용 과정에서 발생하는 환경적, 안보적 외부성을 최소화하는 에너지수급 구조를 마련하기 위해 2003년 12월 '제2차 신재생에너지 기술개발 및 이용보급 기본계획(2003-2012)'을 발표하였다. 이 계획에서는 2011년까지 전체 TPES의 $5\%$를 신재생에너지로 공급하는 것을 정책목표로 수립하고 수소, 태양광 그리고 풍력기술을 중점적으로 추진하기로 하였다. 특히 수소부문에서는 주택 및 건물용, 발전용, 수송용 연료전지의 개발을 중심으로 개발하여 세계 기술시장의 $20\%$를 확보한다는 계획을 발표하였다. 이러한 기술 잠재력을 기반으로 우리 정부도 미국이나 일본과 같이 수소경제로의 전환을 준비하고 있으며 2020년대 이후 우리나라의 에너지부문은 새로운 국면에 접어들 것으로 전망된다. 에너지나 환경기술의 효과적 인 개발을 위해서는 이들 기술의 직접적인 비용측면에 대한 분석 즉 경제성 평가와 새로운 기술변화로 인한 중장기적인 사회경제적 영향평가가 선행되어야 한다. 이러한 평가는 대상 기술의 사회경제적 파급효과가 광범위할수록 더욱 복잡한 분석이 요구된다. 본 연구의 주제인 수소에너지기술은 지금까지 이용되던 것과는 전혀 새로운 에너지캐리어(carrier)를 개발하는 것으로 에너지부문 및 여타 다른 산업부문이 공유하고 있는 에너지 관련 인프라의 전면적인 조정이 요구되며 에너지 이용과 관련된 사회경제적 측면의 급속한 변화를 수반한다. 본 연구는 수소경제로의 이행에 대한 사회경제적 영향평가의 방법론적 요소들과 기법을 제시한다."중등도 독성"으로 나타났다 이상의 결과는 전기도금을 이용하여 교정용 선재의 직경을 증가시키는 방법이 임상에 적용되기 위해서는 세포독성을 줄이기 위한 추가의 연구가 필요함을 시사하였다.의하게 가장 낮은 정지. 운동 마찰력을 보였고 브라켓-호선 각도가 증가함에 따라 유의하게 정지, 운동 마찰력도 증가하였다 (P<0.001)%$ 낮추지만(p value=0.260) 평균 $D_{max}$는 거의동일 하여($0.3\%$ 감소, p value=0.867), 전통적인 방법보다 우수성이 크게는 없는 것으로 평가되었다. 그러나 환자의 체곡선이 보상체와 잘 일치하는 경우에는 DII가 $18\%$까지 감소하였다. 결론 : Multistatic field 방법은 모든 환자에 대하여 선량분포의 균일성을 전반적으로 향상시키는 효과적인 방법으로 평가되는 반면 공용보상체의 사용은 보상체의 크기가 환자의 체 윤곽과 잘 일치하는 경우만 효과적으로, 적용의 범위에는 한계가 있는 방법으로 평가되었다.비교하여 계통에 따르는 차이가 있음을 알 수 있었다. 그러므로 가임기 여성의 방사선 진단 및 치료시 Rugh의 10일 법칙을 적용하여 착상전기 방사선 조사로 인한 부작용들을 적극적으로 예방하는 것이 매우 중요하다고 생각한다.equirements of the prematured infants during the early weeks of life. 모든 치근단 수준에서 비표준화 medium 크기 master cone 사용군이 ISO 표준화 규격의 master cone 사용군에 비해

  • PDF

Study on Determination of Proper Pillar Width in Road Tunnel Design Stage (도로터널에서 적정한 필라폭 산정에 관한 연구)

  • Yang, Tae-Seon;Kim, Jae-Kyoung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.5
    • /
    • pp.187-194
    • /
    • 2010
  • As the design of the pillar width (PW) of the parallel tunnels in downtown area, in which are located in plains zone with deep alluvium compared with mountain tunnels, is directly related with pre-compensation payment and costs of the underground area, it has to be planned as to keep minimum distance while securing the stability of the parallel tunnels. Although PW of downtown road tunnel in Korea is standardized as 1.5D(D: diameter of the tunnels), PW sometimes has to be reduced within 1.5D to adjust the tunnel lines to the city plan in the cases of the inlet and outlet of the tunnels. In this paper, the design and the analyses of optimum PW of the NATM type road tunnel in the downtown area are introduced. The relationship among the tunnel line planning and underground compensation fee, and ground characteristics are evaluated. In the determination of PW distance, the numerical analyses of underground road tunnels were performed, including the use of the strength decrease method and strength/stress ratio method. In the cases of inlet and outlet part of the tunnels where the stability of the pillars is poor due to contiguous construction of the parallel tunnels, the reinforcement methods are recommended for securing the stability. Numerical verification was performed for the reinforcement proposed.

Designing a Library Collaborative Instruction Using the Archives of the National Debt Redemption Movement: Focusing on the Korean History Subject in High School (국채보상운동 기록물을 활용한 도서관협력수업 설계: 고등학교 한국사 교과를 중심으로)

  • Miae Song;Ji-won Lee
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.23 no.4
    • /
    • pp.47-71
    • /
    • 2023
  • Korea is a record powerhouse nation with the largest number of Memory of the World in the Asia-Pacific; however, active utilization of archives for future generations has been lacking. Therefore, this study sought to enhance interest in archives and utilize them directly in school lessons. The Korean National Debt Redemption Movement's archives, which were selected as a Memory of the World, were used in the school lessons, and based on them, a library collaborative instruction design was developed. A library collaborative instruction is a collaboration between the high school Korean history subject and the library information literacy instruction, designed in three sessions. Through the literature research-based design, a library collaborative instruction plan, teaching and learning plan, and activity sheets were derived. Implementing this designed library collaborative instruction is expected to stimulate interest in the Memory of the World, linking curriculum and archives at schools and significantly expanding the users of the archives into teachers and students.

The Diagnosis and Treatment of Anterior Openbite Malocclusion (전치부 개방교합의 진단과 치료)

  • Chang, Young-Il;Moon, Seong-Cheol
    • The korean journal of orthodontics
    • /
    • v.28 no.6 s.71
    • /
    • pp.893-904
    • /
    • 1998
  • There are varieties of severe malocclusions, which can be treated orthodontically, but with a great deal of effort. Anterior openbite, in particular, is one malocclusion thought to be more difficult to treat, and therefore, most of them have to be corrected by means of surgical intervention. To solve these problems, numerous studies pertinent to treatment modalities have been introduced with controversies on the effectiveness of treatment. Suggested treatment modalities for anterior openbite are based directly or indirectly on the neuromuscular and morphological features and on the etiologic and/or the environmental factors. Even though the vertical relationship of the face is increased due to the growth variation, the normal occlusal relationship can be achieved by the adequate dentoalveolar compensatory mechanism, but in the case of inadequate or negative dentoalveolar compensation, openbite is likely to be present. If the skeletal dysplasia is too severe to be solved by orthodontic treatment alone, combined treatment with surgery should be done to restore the function and the esthetics of the orofacial complex. In many cases, however, orthodontic alteration of the dentition pertinent to the given skeletal pattern with the proper diagnosis and treatment planning can bring satisfactory results. The treatment changes with the Multiloop Edgewise Archwire(MEAW) therapy occurred mainly in the dentoalveolar region and showed a considerable similarity to the natural dentoalveolar compensatory mechanism. In other words, the MEAW technique allows orthodontists to produce the natural dentoalveolar compensation orthodontically. Even if an openbite is corrected by the orthodontic dentoalveolar compensation suitable for the skeletal pattern, relapse may still occur by the persisting etiologic factors which originally prohibited the natural dentoalveolar compensation. The etiologic factors should be determined at the time of initial diagnosis and should be controlled during treatment and retention.

  • PDF

Study on Assessment Institution of Urban Ecosystem in Korea (우리 나라의 도시생태계 평가제도 고찰)

  • 오충현
    • Korean Journal of Environment and Ecology
    • /
    • v.16 no.2
    • /
    • pp.188-194
    • /
    • 2002
  • Assessment institution of urban ecosystem is divided into ‘Urban Planning Act’and ‘Environmental Management Act’in Korea. The assessment institution of urban planning is divided into ‘Standard of land development approval’and ‘Environmental assessment of urban planning’. The institution of environmental management is divided into ‘Environmental impact assessment’and ‘Advance environmental assessment’. Assessment institution of urban ecosystem is progressed very slowly, because of development oriented policy. And so there are many problems that objective assessment method is not invented except ‘Degree of growing tree number per unit area’and ‘Degree of human disturbance of vegetation’, and insufficiency of conservation measures or post evaluation, etc. Activation of assessment institution of urban ecosystem is necessary followed countermeasures in Korea. (1) Development of objective assessment method for urban ecosystem as biotope map, (2) Appointment of censer-vation zone or consideration of damage for high value in conservation, (3) Parallel establishment of development and ecosystem conservation plan, and enforcing post evaluation