• Title/Summary/Keyword: 보상계획

Search Result 154, Processing Time 0.033 seconds

Application of Hemeroby for Environmental Assessment with Environmental Planning - Focused on the Case“LG Village”- (Hemeroby를 이용한 자연환경평가 및 환경계획 - LG 빌리지의 사례를 중심으로 -)

  • 김혜주;조수경
    • Korean Journal of Environment and Ecology
    • /
    • v.12 no.3
    • /
    • pp.253-258
    • /
    • 1998
  • It is common in foreign countries to make a compensative plan for environmental destruction which is caused by development action even in where development is permitted. But, in Korea, environmental plan was regarded as just meeting the legal standard of green area in site development. This study focused on the case of university project, LG village plan, is to evaluate the environment of the site using Hemeroby and suggested restoration plan in compensation for the destructive. The site was a huge development area of apartment located in Suwon. First of all, we evaluated the site using Hemeroby and compared this with LG village plan. Then, we made a compensative plan for the environmental destruction which was not compensated in LG village plan. The results were as follows; $\beta$-/$\alpha$-euhemeroby of the Site was 80.1% before the development and, after the development, $\beta$-/$\alpha$-euhemeroby of the site dropped to 43.7% and meta-hemeroby increased from 56.3% to 17%. Therefore, we could accept the buildings of LG village development plan and suggested a compensative plan with which we could raise $\beta$-/$\alpha$-euhemeroby like restoring the river, greening parking-lots and rooftops, revegetating cut slope.

  • PDF

Algorithm for the design of a Virtual Compensator Using the Multileaf Collimator and 3D RTP System (다엽콜리메터와 삼차원 방사선치료계획장치를 이용한 가상 선량보상체 설계 알고리듬)

  • 송주영;이병용;최태진
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.185-191
    • /
    • 2001
  • The virtual compensator which are realized using a multileaf collimator(MLC) and three-dimensional radiation therapy Planning(3D RTP) system was designed. And the feasibility study of the virtual compensator was done to verify that it can do the function of the conventional compensator properly. As a model for the design of compensator, styrofoam phantom and mini water phantom were prepared to simulate the missing tissue area and the calculated dose distribution was produced through the 3D RTP system. The fluence maps which are basic materials for the design of virtual compensator were produced based on the dose distribution and the MLC leaf sequence file was made for the realization of the produced fluence map. Ma's algorithm were applied to design the MLC leaf sequence and all the design tools were programmed with IDL5.4. To verify the feasibility of the designed virtual compensator, the results of irradiation with or without a virtual compensator were analyzed by comparing the irradiated films inserted into the mini water phantom. The higher dose area produced due to the missing tissue was removed and intended regular dose distribution was achieved when the virtual compensator was applied.

  • PDF

Orthophoto Application for Geo-spatial Information Acquisiton of Construction Area(DAM) (공사지역(댐)의 지형정보구축을 위한 정사영상의 활용)

  • 한승희;이형석;이성순
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.18 no.4
    • /
    • pp.395-403
    • /
    • 2000
  • It is so sensitive that the matter of compensation for private possessions caused in the course of public construction planning is very important. Especially, more logical planning is necessary when the dam be constructed, because it is mainly controlled by the surface of water, and if that planning is made public, artificial change is occurred in land use in that area for the purpose of rising the compensation. In this study, the plan for the application of aerial photo based ortho image was drew up for solving these problems and for the rational, rapid compensation. Ortho image was made by aerial photo, used as reading material for the change in land use. The modeling of drainage basin, came under the planning surface of water, and the 3D simulation were performed for the scene analysis, the change understanding in land use for a lot number in a certain period by overlapping the digital image, the digital land registration map, and the digital topography map as well as the analysis of the admitted land followed by the height of reservoir water.

  • PDF

The Path Plan for Slip Reduction of Mobile Robot and Slip Compansation Method (이동 로봇의 슬립 감소를 위한 이동 경로 계획 및 슬립 보상방식)

  • Eom, Ki-Hwan;Kang, Seong-Ho;Jung, Kyung-Kwon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.4
    • /
    • pp.785-796
    • /
    • 2009
  • In this paper, propose for mobile robot path planning and the reduction in sleep caused by a sleep history suggested a way to compensate for record sensor error. The proposed path plan reduces the robot slip to smooth a potential barrier in the potential field method, and compensates the tachometer error by robot slip using the fuzzy logic system. The efficiency of the proposed method is verified by means of simulations and experiments for path plan and slip revision.

"농업손실보상"에 관한 농업인 법률구조사례

  • Korea Duck Association
    • Monthly Duck's Village
    • /
    • v.62 no.8
    • /
    • pp.58-63
    • /
    • 2008
  • 농업의 손실에 대한 보상은 공익사업시행지구 안에서 사업안정고시일등 당시 영농을 하는 농민에게 당해 공공사업용지에 편입되는 농지에 대하여 도별 연간 농가평균 농작물 수입을 기준으로 2년분의 소득을 영농손실액으로 지급하는 것을 말한다. 원칙적으로 보상계획공고 또는 사업안정고시일 당시의 실제 경작자가 농업손실보상의 대상자이다. 구체적으로 살펴보면 '전, 답 또는 과수원이나 기타 그 법적 지목 여하를 따지지 않고 실제 토지현황이 농작물 경작 또는 다년생 식물 재배지로 이용되는 토지'가 보상 대상이 된다.

  • PDF

The Analysis of a Cerrobend Compensator and a Electronic Compensator Designed by a Radiation Treatment Planning System (방사선치료계획장치로 설계된 Cerrobend 선량보상체와 전자 선량보상체의 제작 및 특성 분석)

  • Nah Byung-Sik;Chung Woong-Ki;Ahn Sung-Ja;Nam Taek-keun;Yoon Mi-Sun;Song Ju-Young
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.82-88
    • /
    • 2005
  • In this study, the physical compensator made with the high density material, Cerrobend, and the electronic compensator realized by the movement of a dynamic multileaf collimator were analyzed in order to verify the properness of a design function in the commercial RTP (radiation treatment planning) system, Eclipse. The CT images of a phantom composed of the regions of five different thickness were acquired and the proper compensator which can make homogeneous dose distribution at the reference depth was designed in the RTP. The frame for the casting of Cerrobend compensator was made with a computerized automatic styrofoam cutting device and the Millennium MLC-120 was used for the electronic compensator. All the dose values and isodose distributions were measured with a radiographic EDR2 film. The deviation of a dose distribution was $\pm0.99 cGy\;and\;\pm1.82cGy$ in each case of a Cerrobend compensator and a electronic compensator compared with a $\pm13.93 cGy$ deviation in an open beam condition. Which showed the proper function of the designed compensators in the view point of a homogeneous dose distribution. When the absolute dose value was analyzed, the Cerrobend compensator showed a $+3.83\%$ error and the electronic compensator showed a $-4.37\%$ error in comparison with a dose value which was calculated in the RTP. These errors can be admtted as an reasonable results that approve the accuracy of the compensator design in the RTP considering the error in the process of the manufacturing of the Cerrobend compensator and the limitation of a film in the absolute dosimetry.

  • PDF

System planning effect of Power Quality compensation in nodal cost electric market (모선 가격을 적용하고 있는 전력시스템에 전력품질보상제도가 계통계획에 주는 영향)

  • Lee, Geun-Joon;Jung, Sung-Won;Kang, Ku-Tag;Gim, Jae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.323-324
    • /
    • 2006
  • 본 논문은 모선가격을 적용하는 계통에서 전력품질기준을 초과한 수용가에 대한 보상을 하는 것이 계통계획상의 의사결정에 어떠한 영향을 주는가에 대한 시험 연구 결과이다. 우리나라는 산업의 고도화에 따라 전력에 대한 산업의 의존 비율이 대폭 증가하였을 뿐만 아니라, 전력품질에 대한 산업체의 요구조건도 과거에 비해 매우 높아졌다. 그러나 현행 계통계획과 전력요금제도에는 이러한 사회적 변화를 반영할 품질에 대한 요소가 포함되어 있지 않으며, 이에 대한 적절한 대비가 되지 않음으로 인한 사회적 비용은 제대로 평가되지 못하고 있다. 본 논문에서는 수용가에 대한 전력요금이 모선별로 할당되는 경우에 각 모선의 전력품질이 측정가능하고 이를 보상비용화 할 수 있다고 가정하는 경우, 이를 계통계획에 반영하였을 때 예상되는 효과를 모의계통을 통하여 시산해보고 그 결과를 토의한 것이다. 그 결과, 전력품질의 비용을 반영한 경우, 전력요금은 상승하지만 전체 비용을 최소화하는 요소설비에 투자하는 방법을 선택함으로써 총괄비용을 감소시키는 효과를 거둘 수 있다.

  • PDF

The Comparative study of Land Compensation Act between korea & japan (한·일 토지보상법 비교연구)

  • Jeon, Chang-Jin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.1
    • /
    • pp.163-170
    • /
    • 2012
  • Most of the cities and countries have distressed themselves about the urban social problem caused by the concentration of industry and population. Especially, disorderly expansion of cities and infrastructure improvement in rapid urbanization have also come into question. For this reason, proven urban planning facilities and tightened regulation on city planning are indispensible to solve these serious problems that we face. There are lots of similar studies to verify how to cope with a rapid urbanization.

Automation of Public Land Acquisition Results For Reliable Statistics (보상자료 통계 신뢰성 제고를 위한 공공용지 취득실적집계 자동화방안)

  • Seo, Myoung-Bae;Kim, Nam-Gon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.04a
    • /
    • pp.1430-1431
    • /
    • 2012
  • 토지보상관련 법을 관장하고 있는 국토해양부는 "국토기본법" 제24조의 규정에 따라 용지보상 등을 포함한 국토의 계획 및 이용의 주요시책에 관한 보고서를 매년 정기국회의 개회전까지 국회에 제출하여야 한다. 이 보고서에는 국가보상에 관한 주요통계자료가 포함되는데 이러한 공공용지의 취득 및 손실보상 실적은 보상관련 정책의 수립과 제도개선 및 부동산정책 등에 중요한 기초 자료로 활용되고 있다. 하지만 90여개 기관을 대상으로 9개 양식을 수작업으로 취합하다 보니 시간소요 및 통계오류 등이 발생할 소지가 있어 국가통계의 신뢰도가 저하될 소지가 있다. 이에 정확한 보상통계자료 제공 및 업무의 효율성 제고를 위해 공공용지 취득실적 집계 자동화방안을 제시하고자 한다.

The Benefit of Individualized Custom Bolus in the Postmastectomy Radiation Therapy : Numerical Analysis with 3-D Treatment Planning (유방전절제술 후 방사선치료를 위한 조직보상체 개발 및 3차원 치료계획을 통한 유용성 분석)

  • Cho Jae Ho;Cho Kwang Hwan;Keum Kichang;Han Yongyih;Kim Yong Bae;Chu Sung Sil;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.82-93
    • /
    • 2003
  • Purpose : To reduce the Irradiation dose to the lungs and heart in the case of chest wail irradiation using an oppositional electron beam, we used an Individualized custom bolus, which was precisely designed to compensate for the differences In chest wall thickness. The benefits were evaluated by comparing the normal tissue complication probablilties (NTCPS) and dose statistics both with and without boluses. Materials and Methods : Boluses were made, and their effects evaluated in ten patients treated using the reverse hockey-stick technique. The electron beam energy was determined so as to administer 80% of the irradiation prescription dose to the deepest lung-chest wall border, which was usually located at the internal mammary lymph node chain. An individualized custom bolus was prepared to compensate for a chest wall thinner than the prescription depth by meticulously measuring the chest wall thickness at 1 emf intervals on the planning CT Images. A second planning CT was obtained overlying the individuailzed custom bolus for each patient's chest wall. 3-D treatment planning was peformed using ADAC-Pinnacle$^{3}$ for all patients with and without bolus. NTCPS based on 'the Lyman-Kutcher' model were analyzed and the mean, maximum, minimum doses, V$_{50}$ and V$_{95}$ for 4he heari and lungs were computed. Results .The average NTCPS in the ipsliateral lung showed a statistically significant reduction (p<0.01), from 80.2${\pm}$3.43% to 47.7${\pm}$4.61%, with the use of the individualized custom boluses. The mean lung irradiation dose to the ipsilateral iung was also significantly reduced by about 430 cGy, Trom 2757 cGy to 2,327 cGy (p<0.01). The V$_{50}$ and V$_{95}$ in the ipsilateral lung markedly decreased from the averages of 54.5 and 17.4% to 45.3 and 11.0%, respectively. The V$_{50}$ and V$_{95}$ In the heart also decreased from the averages of 16.8 and 6.1% to 9.8% and 2.2%, respectively. The NTCP In the contralateral lung and the heart were 0%, even for the cases with no bolus because of the small effective mean radiation volume values of 4.4 and 7.1%, respectively Conclusion : The use of an Individualized custom bolus in the radiotherapy of postrnastectorny chest wall reduced the NTCP of the ipsilateral lung by about 24.5 to 40.5%, which can improve the complication free cure probability of breast cancer patients.