• Title/Summary/Keyword: 보건의질

Search Result 4, Processing Time 0.017 seconds

The Factors Affecting the Health Preservation of Building Workers (빌딩관리업(FM)종사자 보건의 질에 영향을 미치는 요인)

  • Kim, Jung-Hoon
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2022.10a
    • /
    • pp.233-234
    • /
    • 2022
  • 본 연구에서는 빌딩 시설물 관리를 시행함에 있어 현행 보건환경에 영향을 미치는 보건관리 요인인 보건관리자 고용, 사전보건교육, 개인위생장구 지급, 물질안전보건자료 관리, 석면보건관리, 공조시설 관리 등이 보건의 질에 미치는 영향을 통해 실질적이고 효과적인 빌딩 시설물 관리에서의 쾌적한 보건환경 확보를 목적으로 실시하였다.

  • PDF

A Study of System and Practices of the Old Age Pension in North Korea (북한 년로년금의 제도와 실태에 관한 연구)

  • Min, Ki-Chae;Cho, Sung-Eun;Han, Kyoung-Hun
    • Korean Journal of Family Social Work
    • /
    • no.60
    • /
    • pp.133-173
    • /
    • 2018
  • This paper analyzes the consistency and the discrepancy between system and practices of the old age pension(Nyunronyungeum) in North Korea. The literature review is conducted to analyze the system. Specifically, the North Korean law and North Korean dictionaries were carefully examined. The interviews with 25 North Korean refugees were conducted to grasp the exact state of the old age pension in North Korea. Major findings are as follows: the consistency between system and practices of the old age pension in North Korea is identified only certain portions of that. Beneficiaries(blue-collar workers, white-collar workers, farmers, soldiers, and employees in foreign-invested enterprises), contribution periods, earning-related schemes, the totalization of periods of coverage(workplace transitions), the absence of double benefits and early retirement pension, and the delivery system around Civic Service offices(Dong offices) are confirmed by complete consistency. Preservation age, variations in the implementation of the pension system by region, and premium of the old age pension are confirmed by partial consistency. The length of service, the labor regulation, lump-sum payment, and double dipping are confirmed by discrepancies. It's important that this study brings about a better understanding the old age pension in North Korea through various original texts of North Korea and interviews with refugees. The results of this study are expected to contribute to the policy production for the age income security system after the unification and to the spread of unification perspectives.

Evaluation of Image Quality for Compressed SENSE(CS) Method in Cerebrovascular MRI: Comparison with SENSE Method (뇌혈관자기공영영상에서 Compressed SENSE(CS) 기법에 대한 영상의 질 평가: SENSE 기법과 비교)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.999-1005
    • /
    • 2021
  • The object of this research is CS, which increases resolution while shortening inspection time, is applied to MRA to compare the quality of images for SENSE and CS techniques and to evaluate SNR and CNR to find out the optimal techniques and to provide them as clinical basic data based on this information. Data were analyzed on 32 patients who performed TOF MRA tests at a university hospital in Chung cheong-do (15 males, 17 females), ICA stenosis:10, M1 Aneurysm:10, and average age 53 ± 4.15). In the inspection, the inspection equipment was Ingenia CX 3.0T, Archieva 3.0T, and 32 channel head coil and 3D gradient echo as a method for equipment data. SNR and CNR of each image were measured by quantitative analysis, and the quality of the image was evaluated by dividing the observer's observation into 5 grades for qualitative evaluation. Imaging evaluation is described as being significant when the p-value is 0.05 or less when the paired T-test and Wilcoxon test are performed. Quantitative analysis of SNR and CNR in TOF MRA images Compared to the SENSE method, the CS method is a method measurement method (p <0.05). As an observer's evaluation, the sharpness of blood vessels: CS (4.45 ± 0.41), overall image quality: CS (4.77 ± 0.18), background suppression of images: CS (4.57 ± 0.18) all resulted in high CS technique (p = 0.000). In conclusion, the Compressed SENSE TOF MRA technique shows superior results when comparing and evaluating the SENSE and Compressed SENSE techniques in increased flow rate magnetic resonance angiography. The results are thought to be the clinical basis material in the 3D TOF MRA examination for brain disease.

Evaluation of Image Quality using SE-EPI and SSH-TSE Techniques in MRDWI (자기공명확산강조영상에서 SE-EPI 와 SSH-TSE 기법을 이용한 영상의 질 평가)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.991-998
    • /
    • 2021
  • The purpose of this study is to investigate the image quality of the SE-EPI and SSH-TSE technique for MR DWI. Datum were analyzed for 35 PACS transmission datum(Normal part: 12 males, 13 females, Cerebral Infarction: 10(5males and 5females), and average age 68±7.32), randomly selected patients who underwent MRDWI tests. The equipment used was Ingenia CX 3.0T, SSH_TSE and SE-EPI pulse sequence and 32 Ch. head coil were used for data acquisition. Image evaluation was performed on the paired t-test and Wilcoxon tests, and was considered significant when the p value was 0.05 or less. As a result of quantitative analysis of SNR for DWI images, the mean and standard deviation values of 4 parts (WM, GM, BG, Cerebellum) in ADC (s/mm2), Diffusion b=0, 1000 images were higher in SE-EPI techniques(ADC: 120.50 ± 40, b=0: 54.50 ± 35.91, b=1000: 91.61 ± 36.63) than in SSH-TSE techniques(ADC: 99.69 ± 31.10, b=0: 43.52 ± 25.00 , b=1000: 60.74 ± 24.85)(p<0.05). The CNR values for GM-WM, BG-WM sites were also higher in SE-EPI technique (ADC: 116.08 ± 43.30, b=0:27.23 ± 09.10, b=1000: 78.50 ± 16.56) than in SSH-TSE(ADC: 101.08 ± 36.81, b=0: 23.96 ± 07.79 , b=1000: 74.30 ± 14.22). As a visual evaluation of observers, ghost artifact, magnetic susceptibility artifacts and overall image quality for SE-TSE and SSH-TSE all yielded high results from SSH-TSE techniques(ADC:3.6 ± 0.1, 2.8 ± 0.2, b=0: 4.3 ± 0.3, 3.4 ± 0.1 b=1000: 4.3 ± 0.2, 3.5 ± 0.2, p=0.000). In conclusion, the SE-EPI technique obtained an superiority in SNR and CNR measurements using SSH-TSE, SE-EPI. In the qualitative analysis, the SSH-TSE pulse sequence was obtained a high result according to the pulse sequence characteristics.