• Title/Summary/Keyword: 보강 효과

Search Result 1,779, Processing Time 0.027 seconds

Strengthening Effect of Axial Circular Concrete Members Wrapped by CFRP sheet (CFRP sheet로 감싼 원형 콘크리트 압축부재의 보강 효과)

  • Moon, Kyoung-Tae;Park, Sang-Yeol;Kim, Moon-Kwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.5
    • /
    • pp.10-21
    • /
    • 2015
  • Many studies have been carried out on carbon fiber-reinforced plastic sheet(hereafter CFRP sheet)-confined concrete specimens for improve structural performance of concrete structures. To complement the existing studies, a parametric study is conducted to examine the effect of various design parameters such as layers of CFRP sheet, size and aspect ratio of specimens, and overlap length. The behavior of CFRP-confined concrete is compared using stress-strain curves of each specimen. And the strengthening effect of CFRP sheet is examined by maximum compressive strength. As the layers of CFRP sheet increases, structural performance of CFRP-confined concrete is significant increased. If the overlap length is more than 5% of circumstance, strengthening effect is not affected. In addition, a test database assembled from test results and existing studies is presented. Using these test database, accuracy and reliability of the existing strength models for CFRP-confined concrete are verified.

The Effect of Shear Resistance in Rigid Soil-nailed Slope System (강성 쏘일네일 보강 사면의 전단저항 효과)

  • Kwon, Young-Ki;Jeong, Sang-Seom
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.6C
    • /
    • pp.295-301
    • /
    • 2009
  • In general the stability of soil nail-slope system, the shear resistance is neglected because the tensile resistance of nail acts mainly for slope stabilization. This is because that deformed steel is generally used for nail and it does ductile behavior. In other side when the steel pipe with high rigidity is used for nail, the shear resistance at failure surface work more than deformed steel. In order to analyze effects of shear resistance at the soil nail-slope system with high steel piped nail, a series of numerical analyses were performed. Also numerical analyses at 3 conditions - 5 nailed, 7 nailed, 9 nailed at the same slope were perfomed for investigating the trend of shear resistance effect. From these 3D numerical analyses, it was found that the maximum shear resistances at each nails were larger in case of steel piped nail and because of this, the factor of safety at the condition of the steel piped nail appears larger than that of deformed steel nail.

Effect of an Opening on Buckling Strength of Polygonal Section Wind Turbine Tower (다각형 단면 풍력타워 좌굴강도에 대한 개구부의 영향)

  • Choi, Byung Ho;Park, Seong Mi;Hwang, Min Oh
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.163-163
    • /
    • 2011
  • 풍력타워 기둥구조물에는 유지관리 등의 이유로 출입구 역할을 하는 개구부가 존재하게 된다. 다각형 타워구조물에 개구부형상이 존재하게 되면 압축좌굴 강도에 영향이 있을 것으로 예상되지만, 이를 정량적으로 평가하거나 예측하기는 용이하지 않고 간접적으로 판단할 만한 관련 기준이나 지침도 부족한 상태이다. 이에 최병호 등(2011)에서 다룬 다각형 단면 기둥구조물의 하단에 개구부를 형상화한 수치해석 모델을 수립하고 축방향 압축하중을 재하하는 탄성좌굴 해석 및 비선형비탄성해석을 수행하였다. 본 논문에서는 기존 다각형 단면 기둥모델 중에서 6각형 단면모델에 관해 중점적으로 다루고 있다. 다각형 단면 기둥 해석모델은 단순한 다각형 단면 타워구조에 대해서 뿐 만 아니라, 각 subpanel에 종방향 보강재를 둔 모델에 대해서도 추가적으로 검토하였다. 개구부의 형상은 높이 2000mm, 폭 800mm이며 상하부에 만곡부를 둔 형태이다. 수치해석은 3차원 유한요소해석프로그램인 ABAQUS를 이용하여 수행하였으며, 보강방안으로는 일정범위까지의 모듈 subpanel의 판두께를 보강하는 방안과 edge stiffener를 적용하는 방안에 대해서 검토하였다. 각각의 보강방식에 따른 효과를 비교해 보기 위해 개구부가 없는 모델, 단순히 개구부만 설정한 모델, 판두께를 보강한 모델, edge stiffener로 보강한 모델에 대해 비교해석을 수행하였다. 보강재 없는 단순 다각형 타워구조 모델에 대한 해석결과로부터 개구부로 인한 강도저하는 미미한 수준인 것으로 나타났다. 반면, 종방향 보강재가 적용된 6각형 단면 타워구조 모델에서는 개구부로 인한 강도저감이 22.9%로 높게 나타났으며 상당한 영향이 있는 것으로 분석되었다. 또한 개구부 주변의 판두께 보강이나 edge stiffener보강 등으로 상당한 강도향상 효과가 확인되었으나, 개구부로 인해 손실된 강도 수준을 완전히 회복하는 수준에 미치지 못하는 것으로 나타났다. 따라서, 향후 다양한 보강방식에 대한 보다 포괄적인 변수연구를 통해 개구부의 영향 없이 온전한 다각형 단면 타워 구조의 극한강도에 도달되기 위한 보강 조건에 대해 검토될 필요가 있을 것으로 사료된다.

  • PDF

Shear Capacity of Shear Reinforcement for Punching Shear in Flat Plate Structure (플랫 플레이트 구조에서 뚫림전단에 대한 전단보강체의 보강능력)

  • Kim, Jun-Seo;Choi, Hyun-Ki;Jin, Eon-Sik;Baek, Young-Soo;Choi, Chank-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.17-20
    • /
    • 2008
  • As a part of a research program to study the shear reinforcement of flat plate system, this investigation aimed to determine the effect of shear reinforcement type on punching shear strength of monolithic slab-column connection. A total of 5 specimens were fabrication and tested. The dimension of the slab were $2.63{\ast}2.725{\ast}0.18m$, with a centrally located column $0.6{\ast}0.8m$ in cross section. Experimental results showed that the CFS shear reinforcement was not effective because of lack of proper bond with concrete. 3 shear reinforcement except of CFS showed high effectiveness, which resulted in a considerable increment of the punching shear resistance of the connection.

  • PDF

Evaluation of Failure Mode in Concrete Beam Restrengthened with GFRP with Various Initial Conditions (GFRP로 보강된 다양한 초기 조건의 콘크리트보의 파괴 거동 평가)

  • Jin-Won Nam;Seung-Jun Kwon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.3
    • /
    • pp.177-183
    • /
    • 2023
  • Various failure modes occur in the concrete beams reinforced with GFRP(Glass Fiber Reinforced Plastic) under initial condition and repairing patterns. In this study, the failure behaviors of concrete beams restrengthened with GFRP sheet with slightly higher elastic modulus than concrete were investigated. For the tests, concrete beams with 24 MPa were manufactured, and the effects of initial notch, overlapping, end-strip reinforcement, and fiber anchors were analyzed on failure load. The cases of GFRP overlap around notch and the initial notch showed increasing failure loads similar to those of normal restrengthened case since the epoxy of the saturated GFRP sufficiently repaired the notch area. Compared to the control case without restrengthening of GFRP, the concrete with initial notch showed 0.78 of loading ratio and normal restrengthening showed 4.43~5.61 times of increasing ratio of failure loading, where interface-debonding from flexural crack were mainly observed. The most ideal failure behavior, break of GFRP, was observed when end-strip over 1/3 height from bottom and fiber anchor were installed, which showed increasing failure load over 150 % to normal restrengthening.

Experimental Study on Flexural Behavior of PSC I Girder and the Effect of External Prestressing (PSC I합성 거더의 휨 거동 및 외부 강선 보강효과에 관한 실험 연구)

  • Lee, Byeong-Ju;Park, Jae-Guen;Kim, Moon-Young;Shin, Hyun-Mock;Park, Chang-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.6
    • /
    • pp.755-762
    • /
    • 2007
  • For the evaluation of the load carrying capacity of the deteriorated PSC I girder bridge in service load state and the verification of the grade to the reinforcement effect of actual bridge strengthened by external prestressing tendons, the field test using vehicles is applied widely. Because this teat was executed in elastic range, the investigation of the characteristics of behavior caused by live load is only available. And it is impossible to estimate load carrying capacity in limit state and nonlinear behavior after that a crack is appeared. In this study, the 27-year-old prestressed concrete girder bridge is used and various load tests are performed, so we evaluate the behavior characteristics of the bridge in service load state and ultimate load state, and estimate the load carrying capacity of bridge. In addition, the artificial damages are induced from cutting internal tendons, and external tendons is added to strengthen it as much as vanished internal tendons. Next we compare the damage state with the strengthening state. In case of the application of external prestressing method to PSC I girder bridge, the present experiment result may decide more exactly the load carrying capacity of actual bridge, the amount for reinforcement, and the standard of quality control etc. at reinforcement work.

An Experimental Study on Behavior Characteristics of Geosynthetics Reinforced Retaining Earth Wall (보강압성토 옹벽의 거동 특성에 관한 실험적 연구)

  • Noh, Taekil;Lee, Song
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.3
    • /
    • pp.29-37
    • /
    • 2012
  • This study is to find out the characteristics of the behavior of Geosyntehtic Reinforced Retaining Earth Wall(GRREW) through the laboratory experiment with the reduced-scale model, and to verify the effect of reinforcement by materials of GRREW. The loading tests after combining nonwoven geosynthetic, re-bar mesh nets and drainage blocks respectively among the components of the GRREW were performed in three cases of their slopes. In the cases of the behavior analysis including all of the components of the GRREW, the maximum horizontal displacement was generated 8.4mm at the location of 0.57H in the slope of 1:0.3; 3.8mm at the location of 0.57H in the slope of 1:0.6; 3.6mm at the location of 0.86H in the slope of 1:1.0. On average, the horizontal displacements of the GRREW were reduced by 83.8% against those of the original slopes. Lastly, seepage analysis and slope stability analysis were performed by modelling section of field, to confirm the effect of installation of drainage block in GRREW. We can confirm to compare increasing the slope safe factor and decreasing ground water in accordance with drainage blocks.

Numerical Model Study on a Scheme to Restrain Deformation of a Conduit with Flexible Joints(II) : Effectiveness of Concrete Bedding Reinforcement (연성이음관의 변형억제방안에 관한 수치모델연구(II): 콘크리트베딩 보강효과)

  • 손준익;정하익
    • Geotechnical Engineering
    • /
    • v.7 no.4
    • /
    • pp.15-24
    • /
    • 1991
  • This paper reports the application study of the concrete bedding reinforcement under a buried conduit with flexible joints subjected to differential settlement via a finite elemen modeling. The reinforcement of concrete bedding helps to minimize the differential settlement between the adjoining conduit segments. Three different field conditions have been considered. The settlement pattern and deformation slope have been evaluated for each boundary condition. The analysis results are compared for both non-reinforced and reinforced cases to measure the effectiveness of concrete bedding reinforcement for restraining deformation of a conduit with flexible joints.

  • PDF

A Case Study on Ground improvement of a Retaining Wall Foundation by Using High Pressure Grouting (고압분사공법을 이용한 옹벽기초지반 보강 사례)

  • Park, Jong-Ho;Jang, Sun-Cheul;Park, Chang-Hun;Yoon, Hee-Kyung
    • 기술발표회
    • /
    • s.2006
    • /
    • pp.199-209
    • /
    • 2006
  • 현재 연약지반의 개량 및 구조물기초 지반의 보강을 위하여 약액주입공법 및 고압분사주입공법 등의 주입공법이 널리 행해지고 있는 실정이다. 이에 본 연구에서는 00교 교대 전면 옹벽기초 하부지반을 고압분사주입공법을 이용해 보강한 사례로서 설계 및 시공, 시험 자료를 분석하고, 보강작업에 따른 지반의 개량효과를 분석하였다. 개량효과학인을 위한 시추조사와 시추공영상 촬영 이미지 관찰결과에서는 고압분사에 의해 양호한 상태의 고결체(토사 + 시멘트 페이스트)가 형성되었음을 확인 할 수 있었으며, 고결체와 원지반의 복합지반상에서 실시한 평판재하시험 결과 및 시추조사시 채취된 고결체 Core에 대해 실시한 일축압축강도시험 결과에서도 설계시 가정한 값을 모두 만족하는 것으로 나타나 연약지반의 강도가 개량되어 안정성을 확보한 것으로 확인되었다.

  • PDF

A Study on the Settlement Restraint of the Granular Compaction Pile (조립토 다짐말뚝의 침하저감방안에 관한 연구)

  • Kim, Seung-Wook;Lee, Duck-Won;Kim, Seo-Ryong;Ann, Jai-Gyoo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.336-342
    • /
    • 2005
  • Stone column or granular compaction pile have been used in widely during the several decades as a technique to reinforce soft cohesive soils and increase bearing capacity, accelerate consolidation settlement of the foundation soil. The bearing capacity of the granular compaction pile is governed mainly by the lateral confining pressure mobilized in the native soft soil to restrain bulging collapse of the granular pile. Therefore, the technique becomes unfeasible in soft, compressible clayey soils that do not provide sufficient lateral confinement. This paper presents the main results of numerical study of granular compaction pile which is partly mixed with lean concrete. 3D finite element analyses are performed with composite reinforced foundations by both granular compaction pile and partly mixed granular compaction pile with lean-mixed concrete.

  • PDF