• Title/Summary/Keyword: 보간 필터

Search Result 233, Processing Time 0.017 seconds

Shear-wave elasticity imaging with axial sub-Nyquist sampling (축방향 서브 나이퀴스트 샘플링 기반의 횡탄성 영상 기법)

  • Woojin Oh;Heechul Yoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.403-411
    • /
    • 2023
  • Functional ultrasound imaging, such as elasticity imaging and micro-blood flow Doppler imaging, enhances diagnostic capability by providing useful mechanical and functional information about tissues. However, the implementation of functional ultrasound imaging poses limitations such as the storage of vast amounts of data in Radio Frequency (RF) data acquisition and processing. In this paper, we propose a sub-Nyquist approach that reduces the amount of acquired axial samples for efficient shear-wave elasticity imaging. The proposed method acquires data at a sampling rate one-third lower than the conventional Nyquist sampling rate and tracks shear-wave signals through RF signals reconstructed using band-pass filtering-based interpolation. In this approach, the RF signal is assumed to have a fractional bandwidth of 67 %. To validate the approach, we reconstruct the shear-wave velocity images using shear-wave tracking data obtained by conventional and proposed approaches, and compare the group velocity, contrast-to-noise ratio, and structural similarity index measurement. We qualitatively and quantitatively demonstrate the potential of sub-Nyquist sampling-based shear-wave elasticity imaging, indicating that our approach could be practically useful in three-dimensional shear-wave elasticity imaging, where a massive amount of ultrasound data is required.

Multiple Reference Network Data Processing Algorithms for High Precision of Long-Baseline Kinematic Positioning by GPS/INS Integration (GPS/INS 통합에 의한 고정밀 장기선 동적 측위를 위한 다중 기준국 네트워크 데이터 처리 알고리즘)

  • Lee, Hung-Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1D
    • /
    • pp.135-143
    • /
    • 2009
  • Integrating the Global Positioning System (GPS) and Inertial Navigation System (INS) sensor technologies using the precise GPS Carrier phase measurements is a methodology that has been widely applied in those application fields requiring accurate and reliable positioning and attitude determination; ranging from 'kinematic geodesy', to mobile mapping and imaging, to precise navigation. However, such integrated system may not fulfil the demanding performance requirements when the baseline length between reference and mobil user GPS receiver is grater than a few tens of kilometers. This is because their positioning/attitude determination is still very dependent on the errors of the GPS observations, so-called "baseline dependent errors". This limitation can be remedied by the integration of GPS and INS sensors, using multiple reference stations. Hence, in order to derive the GPS distance dependent errors, this research proposes measurement processing algorithms for multiple reference stations, such as a reference station ambiguity resolution procedure using linear combination techniques, a error estimation based on Kalman filter and a error interpolation. In addition, all the algorithms are evaluated by processing real observations and results are summarized in this paper.

A Study on the Selection of Parameter Values of FUSION Software for Improving Airborne LiDAR DEM Accuracy in Forest Area (산림지역에서의 LiDAR DEM 정확도 향상을 위한 FUSION 패러미터 선정에 관한 연구)

  • Cho, Seungwan;Park, Joowon
    • Journal of Korean Society of Forest Science
    • /
    • v.106 no.3
    • /
    • pp.320-329
    • /
    • 2017
  • This study aims to evaluate whether the accuracy of LiDAR DEM is affected by the changes of the five input levels ('1','3','5','7' and '9') of median parameter ($F_{md}$), mean parameter ($F_{mn}$) of the Filtering Algorithm (FA) in the GroundFilter module and median parameter ($I_{md}$), mean parameter ($I_{mn}$) of the Interpolation Algorithm (IA) in the GridSurfaceCreate module of the FUSION in order to present the combination of parameter levels producing the most accurate LiDAR DEM. The accuracy is measured by the residuals calculated by difference between the field elevation values and their corresponding DEM elevation values. A multi-way ANOVA is used to statistically examine whether there are effects of parameter level changes on the means of the residuals. The Tukey HSD is conducted as a post-hoc test. The results of the multi- way ANOVA test show that the changes in the levels of $F_{md}$, $F_{mn}$, $I_{mn}$ have significant effects on the DEM accuracy with the significant interaction effect between $F_{md}$ and $F_{mn}$. Therefore, the level of $F_{md}$, $F_{mn}$, and the interaction between two variables are considered to be factors affecting the accuracy of LiDAR DEM as well as the level of $I_{mn}$. As the results of the Tukey HSD test on the combination levels of $F_{md}{\ast}F_{mn}$, the mean of residuals of the '$9{\ast}3$' combination provides the highest accuracy while the '$1{\ast}1$' combination provides the lowest one. Regarding $I_{mn}$ levels, the mean of residuals of the both '3' and '1' provides the highest accuracy. This study can contribute to improve the accuracy of the forest attributes as well as the topographic information extracted from the LiDAR data.